• Title/Summary/Keyword: radial

Search Result 5,360, Processing Time 0.045 seconds

Mid-Term Results of 292 cases of Coronary Artery Bypass Grafting (관상동맥 우회술 292례의 중기 성적)

  • 김태윤;김응중;이원용;지현근;신윤철;김건일
    • Journal of Chest Surgery
    • /
    • v.35 no.9
    • /
    • pp.643-652
    • /
    • 2002
  • As the prevalence of coronay artery disease is increasing, the surgical treatment has been universalized and operative outcome has been improved. We analyzed the short and mid-term results of 292 CABGs performed in Kangdong Sacred Heart Hospital. Material and Method: From June 1994 to December 2001, 292 patients underwent coronary artery bypass grafting. There were 173 men and 119 women and their ages ranged from 39 to 84 years with a mean of $61.8{\pm}9.1$ years. We analyzed the preoperative risk factors, operative procedures and operative outcome. In addition, we analyzed the recurrence of symptoms, long-term mortality and complications via out-patient follow-up for discharged patients. Result: Preoperative clinical diagnoses were unstable angina in 137(46.9%), stable angina in 34(11.6%), acute myocardial infarction in 40(13.7%), non-Q myocardial infarction in 25(8.6%), postinfarction angina in 22(7.5%), cardiogenic shock in 30(10.3%) and PTCA failure in 4(1.4%) patients. Preoperative angiographic diagnoses were three-vessel disease in 157(53.8%), two-vessel disease in 35 (12.0%), one-vessel disease in 11(3.8%) and left main disease in 89(30.5%) patients. We used saphenous veins in 630, internal thoracic arteries in 257, radial arteries in 50, and right gastoepiploic arteries in 2 distal anastomoses. The mean number of distal anastomoses per patient was $3.2{\pm}1.0$ There were 18 concomitant procedures ; valve replacement in 8(2.7%), left main coronary artery angioplasty in 6(2.1%), patch closure of postinfarction ventricular septal defect(PMI-VSD) in 2(0.7%), replacement of ascending aorta in 1(0.3%) and coronary endarterectomy in 1(0.3%) patient. The mean ACC time was $96.6{\pm}35.3 $ minutes and the mean CPB time was $179.2{\pm}94.6$ minutes. Total early mortality was 8.6%, but it was 3.1% in elective operations. The most common cause of early mortality was low cardiac output syndrome in 6(2.1%) patients. The stastistically significant risk factors for early mortality were hypertension, old age($\geq$ 70 years), poor LV function(EF<40%), congestive heart failure, preoperative intraaortic balloon pump, emergency operation and chronic renal failure. The most common complication was arrhythmia in 52(17.8%) patients. The mean follow-up period was $39.0{\pm}27.0$ months. Most patients were free of symptoms during follow-up. Fourteen patients(5.8 %) had recurrent symptoms and 7 patients(2.9%) died during follow-up period. Follow-up coronary angiography was performed in 13 patients with recurrent symptoms and they were managed by surgical and medical treatment according to the coronary angiographic result. Conclusion: The operative and late results of CABG in our hospital, was acceptable. However, There should be more refinement in operative technique and postoperative management to improve the results.

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Off Pump Total Arterial Myocardial Revascularization (동맥 도관만을 이용하여 체외심폐순환 없이 시행한 관상동맥우회술)

  • Youn Young Nam;Lee Kyo Joon;Lee Gy Jong;Joo Hyun Chul;Lim Sang Hyun;Kim Seung Ho;Kwak Young Lan;Yoo Kyung Jong
    • Journal of Chest Surgery
    • /
    • v.38 no.5 s.250
    • /
    • pp.349-356
    • /
    • 2005
  • Background: Arterial conduits using in coronary artery bypass grafting (CABG) have been known a great long term patency rates, and improved short and long term clinical outcomes. It has been reported that Off pump CABG has better clinical results than CABG using cardiopulmonary bypass. To evaluate the advantage of arterial conduits over venous conduits and to avoid the adverse effects of cardiopulmonary bypass, we performed total arterial Off pump CABG. Material and Method: From January 2001 to October 2004, Off pump CABG using only arterial conduits was performed on 325 patients with a mean age of $59.3\pm11.9$ years ($36\~83$). Mean ejection fraction was $55.4\pm14.0\%\;(15\~86).$ Angiography showed left main disease or triple-vessel disease in $81.9\%$ of the patients. Indications of using arterial conduits was stenosis $\ge50\%$ of left anterior descending artery, stenosis $\ge80\%$ of branches of left circumflex artery, and stenosis $\ge90\%$ of right coronary artery and its branches. Multi-slice computed tomography was performed on 194 patients to evaluate the short term patency rates. Result: A total of 928 distal anastomoses were performed and the average anastomoses per a patient were $2.86\pm0.78$. There was 1 operative mortality. Postoperative complications were mediastinitis in 6 patients ($1.8\%$), renal failure in 4 patients ($1.2\%$), perioperative myocardial infarction in 3 patients ($0.9\%$), reoperation for bleeding in 3 patients ($0.9\%$). There was no postoperative stroke. Patency rate of arterial conduits was $99.3\%$ (581/585). There were 4 stenoses or competitive flows in 2 radial arteries and 2 right internal mammary arteries. Conclusion: Total arterial Off pump CABG appears to be safe, showing a low surgical mortality and morbidity and excellent short term patency rates of arterial conduits.

The Influences of Perfusion Temperature on Inflammatory and Hematologic Responses during Cardiopulmonary Bypass (체외순환시 염증과 혈액학적 반응에 대한 관류온도의 영향)

  • 김상필;최석철;박동욱;한일용;이양행;조광현;황윤호
    • Journal of Chest Surgery
    • /
    • v.37 no.10
    • /
    • pp.817-826
    • /
    • 2004
  • Background: Several studies have demonstrated that conventional hypothermic cardiopulmonary bypass (CPB) causes cellular injury, abnormal responses in peripheral vascular beds and increased postoperative bleeding, whereas normothermic CPB provides protection of the hypothermic-induced effects and better cardiac recovery. The present study was prospectively performed to compare the effects of normothermic CPB to those of hypothermic CPB on the inflammatory and hematologic responses during cardiac surgery. Material and Method: Thirty-four adult patients scheduled for elective cardiac surgery were randomly assigned to hypothermic CPB (nasopharyngeal temperature $26~28^{\circ}C,$ n=17) or normothermic CPB (nasopharyngeal $temperature>35.5^{\circ}C,$ n=17) group. In both groups, cold $(4^{\circ}C)$ crystalloid cardioplegia was applied for myocardial protection. Blood samples were drawn from radial artery before (Pre-CPB), 10 minutes after starting (CPB-10) and immediately after ending (CPB-OFF) CPB. Total leukocyte and platelet counts, interleukin-6 (IL-6) level(expressed as percent to the baseline of Pre-CPB), D-dimer level, protein C and protein S activity were measured with the blood samples. The amount of bleeding for postoperative 24 hours and blood transfusion after operation were also assessed. All parameters were compared between the two groups. Result: The total leukocyte counts $(10,032\pm65/mm^3)$ and the increased ratio of IL-6 $(353\pm7.0%)$ at CPB-OFF in the normothermic group were higher than that $(7,254\pm48/mm^3$ and $298\pm7.3%)$ of the hypothermic group(p=0.02 and p=0.03). In the normothermic group, protein C activity $(32\pm3.8%)$ and protein S activity $(35\pm4.1%)$ at CPB-OFF were significantly lower than that $(45\pm4.3%$ and $51\pm3.8%)$ of the hypothermic group (p=0.04 and p=0.009). However, there were no differences in platelet counts and D-dimer concentration. In the normothermic group, the amount of bleeding for postoperative 24 hours $(850\pm23.2$ mL) and requirements for blood transfusion after operation such as packed cell $(1,402\pm20.5$ mL), fresh frozen plasma $(970\pm20.8$ mL) and platelet $(252\pm6.4$ mL) were higher than that $(530\pm21.5$ mL, $696\pm15.7$ mL, $603\pm18.2$ mL and $50\pm0.0$ mL) of the hypothermic group. Conclusion: These results indicate that normothermic CPB with cold crystalloid cardioplegia was associated with higher increase in inflammatory response, hemostatic abnormalities and postoperative bleeding problem than moderate hypothermic CPB.

Minimally Invasive Coronary Artery Bypass Grafting (소침습적 관상동맥우회술)

  • Na, Chan-Young;Lee, Young-Tak;Park. Joong-Won;Chung, Do-Hyun;Jung, Ill-Sang;Jung, Yoon-Seup;Kim, Ok-Sung;Bang, Jung-Hyun;Lee, Sub;Chung, Chul-Hyun;KIM, Woong-Han;Park, Young-Kwan;Kim, Chong-Whan;Hong, Sung-Nok;Han, Jae-Jin;Lee, Gun
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.118-124
    • /
    • 1998
  • Minimally invasive coronary artery bypass grafting without using cardiopulmonary bypass (CPB) is a recently accepted modality of myocardial revascularization prcedures which is particularly suitable to the patients with lesions in the left anterior descending(LAD) and the right coronary arteries. Of the consecutive 35 patients of coronary artery bypass grafting performed at Sejong General Hospital from March to August 1996, six patients underwent minimally invasive coronary artery bypass grafting without CPB. All had stenotic lesions of the LAD more than 90%. Bypass grafting of the LAD was approached through midline sternotomy in one, through ministernotomy in two, and through limited left anterior thoracotomy in three patients, respectively. The internal mammary arteries were prepared without the use of thoracoscope. The mobilized mammary arteries were connected directly to the LAD in 5 patients, and the anastomosis required interposition of a segment of the radial artery in the remaining one. The diagonal branch was revascularized with the saphenous vein graft at the same time in one patient. No blood transfusion was necessary in 2 patients, and average blood required during surgery was 800ml in 4 patients. All patients were extubated from 4 to 14 hours(mean 9 hours) after operation. Early postoperative coronary angiography in 5 patients between 7 and 10 days after surgery has proved full patency of the grafts. With these limited clinical experiences, the clinical results demonstrated that minimally invasive coronary artery bypass grafting without CPB is an useful procedure especially in patients with isolated lesion in the proximal LAD.

  • PDF

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

A Study on the Fabrication of the Laminated Wood Composed of Poplar and Larch (포푸라와 일본잎갈나무의 집성재 제조에 관한 연구)

  • Jo, Jae-Myeong;Kang, Sun-Goo;Kim, Ki-Hyeon;Chung, Byeong-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.25-31
    • /
    • 1974
  • 1. Various gluing qualities applying Resorcinol Plyophen #6000 were studied on aiming the strength relationships of laminated woods resulted by single species [poplar (Populus deltoides), larch(Larix leptolepis)], mixed species of (poplar and larch), preservatives, treated poplar the scarf joint with mixed species of poplar and larch and the scarf joint treated with preservatives. 1. 1 On the block shear and on the DVL tension test, the mean wood failure ratio showed an excellent value i.e., above 65% and the tangential strength for larch was higher than that of radial, but it was reversed for poplar as shown in Tables 1 and 2. 1. 2 The lamina treated with Na-PCP reduced slightly the strength but the limited strength allowed for manufacturing laminated wood was not influenced by treating Na-PCP as shown in Tables 3 and 4. 1. 3 The safe scarf ratio in the plane scarf joint was above 1/12 for larch and 1/6 for poplar regard less of the chemical treatment or untreatment as shown in Tables. 5, 6, 7 and 8. 2. In the normal and boiled state, the gluing quality of the laminated wood composed of single[poplar (Populus deltoides), larch (Larix leptolepis)] and double species (poplar and larch) glued with Resorcinol Plyophen #6000 were measured as follow, and also represented the delamination of the same laminated wood. 2.1 The normal block shear strength of the straight and curved laminated wood (in life size) were more than three times of the standards adhesion strength. And, the value of the boiled stock was decreased to one half of the standard shear adhesion strength, but it was more than twice the standard strength for the boiled stock. Thus, it was recognized that the water resistance of the Resorcinol Plyophen #6000 was very high as shown in Tables 9 and 10. 2. 2 The delamination ratio of the straight and curved laminated woods in respect of their composition were decraesed, in turn, in the following order i. e., larch, mixed stock (larch+poplar) and poplar. The maximum value represented by the larch was 3.5% but it was below the limited value as shown in Table 11. 3. The various strengthes i.e., compressive, bending and adhesion obtainted by the straight laminaced wood which were constructed by five plies of single and double species of lamina i. e., larch (Larix leptolepis) and poplar (Populus euramericana), glued with urea resin were shown as follows: 3. 1 If desired a higher strength of architectural laminated wood composed of poplar (P) and larch (L), the combination of the laminas should be arranged as follows, L+P+L+P+L as shown in Table 12. 3.2 The strength of laminated wood composed of laminas which included pith and knots was conside rably decreased than that of clear lamina as shown Table 13. 3.3 The shear strength of the FPL block of the straight laminated wood constructed by the same species which were glued with urea adhesives was more than twice the limited adhesion strength, thus it makes possible to use it for interior constructional stock.

  • PDF

Robo-Advisor Algorithm with Intelligent View Model (지능형 전망모형을 결합한 로보어드바이저 알고리즘)

  • Kim, Sunwoong
    • Journal of Intelligence and Information Systems
    • /
    • v.25 no.2
    • /
    • pp.39-55
    • /
    • 2019
  • Recently banks and large financial institutions have introduced lots of Robo-Advisor products. Robo-Advisor is a Robot to produce the optimal asset allocation portfolio for investors by using the financial engineering algorithms without any human intervention. Since the first introduction in Wall Street in 2008, the market size has grown to 60 billion dollars and is expected to expand to 2,000 billion dollars by 2020. Since Robo-Advisor algorithms suggest asset allocation output to investors, mathematical or statistical asset allocation strategies are applied. Mean variance optimization model developed by Markowitz is the typical asset allocation model. The model is a simple but quite intuitive portfolio strategy. For example, assets are allocated in order to minimize the risk on the portfolio while maximizing the expected return on the portfolio using optimization techniques. Despite its theoretical background, both academics and practitioners find that the standard mean variance optimization portfolio is very sensitive to the expected returns calculated by past price data. Corner solutions are often found to be allocated only to a few assets. The Black-Litterman Optimization model overcomes these problems by choosing a neutral Capital Asset Pricing Model equilibrium point. Implied equilibrium returns of each asset are derived from equilibrium market portfolio through reverse optimization. The Black-Litterman model uses a Bayesian approach to combine the subjective views on the price forecast of one or more assets with implied equilibrium returns, resulting a new estimates of risk and expected returns. These new estimates can produce optimal portfolio by the well-known Markowitz mean-variance optimization algorithm. If the investor does not have any views on his asset classes, the Black-Litterman optimization model produce the same portfolio as the market portfolio. What if the subjective views are incorrect? A survey on reports of stocks performance recommended by securities analysts show very poor results. Therefore the incorrect views combined with implied equilibrium returns may produce very poor portfolio output to the Black-Litterman model users. This paper suggests an objective investor views model based on Support Vector Machines(SVM), which have showed good performance results in stock price forecasting. SVM is a discriminative classifier defined by a separating hyper plane. The linear, radial basis and polynomial kernel functions are used to learn the hyper planes. Input variables for the SVM are returns, standard deviations, Stochastics %K and price parity degree for each asset class. SVM output returns expected stock price movements and their probabilities, which are used as input variables in the intelligent views model. The stock price movements are categorized by three phases; down, neutral and up. The expected stock returns make P matrix and their probability results are used in Q matrix. Implied equilibrium returns vector is combined with the intelligent views matrix, resulting the Black-Litterman optimal portfolio. For comparisons, Markowitz mean-variance optimization model and risk parity model are used. The value weighted market portfolio and equal weighted market portfolio are used as benchmark indexes. We collect the 8 KOSPI 200 sector indexes from January 2008 to December 2018 including 132 monthly index values. Training period is from 2008 to 2015 and testing period is from 2016 to 2018. Our suggested intelligent view model combined with implied equilibrium returns produced the optimal Black-Litterman portfolio. The out of sample period portfolio showed better performance compared with the well-known Markowitz mean-variance optimization portfolio, risk parity portfolio and market portfolio. The total return from 3 year-period Black-Litterman portfolio records 6.4%, which is the highest value. The maximum draw down is -20.8%, which is also the lowest value. Sharpe Ratio shows the highest value, 0.17. It measures the return to risk ratio. Overall, our suggested view model shows the possibility of replacing subjective analysts's views with objective view model for practitioners to apply the Robo-Advisor asset allocation algorithms in the real trading fields.

A Study of Mac(脈)-Theory and Change of Mac(脈)-Diagnosis in Whang Di Nei Qing(黃帝內經) (황제내경(黃帝內經)의 맥(脈) 이론(理論)과 진맥법(診脈法)의 변화(變化)에 관(關)한 연구(硏究))

  • Ra, Kyoung-Chan;Park, Hyun Kook
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.2 no.1
    • /
    • pp.73-105
    • /
    • 1993
  • To say nothing of the orient and the west, the human beings discover the method of Jin Mac(診脈) by the way that observe disease. But oriental medicine devise special method of Jin Mac(診脈) in the study of Kyoung Mac(經脈). Although sip-ei Kyoung Mac Jin(十二經脈診), Sam Bu Gu Who Jin(三部九候診), In Young Mac Gu Jin(人迎脈口診), Chon Kwan Chuck Jin(寸關尺診) namely Yuk Bu Jung Wee Jin Mac (六部定位診脈) that is used today are devised, it has changed naturally by the changing treatment and the introduction of Yuin Yang(陰陽) and five element(五行). Many methods dg Jin Mac(診脈), it had not developped successing alternative, it had developped of declined by it's own way. 1. Results for the birth of Mac(脈) 1) Mac(脈), it means Kyoung Mac(經脈), at first entirelly Mac(脈), is seized a blood vessel that flows in the body. As presumed today, after finding many acupunture point, a general idea of Mac(脈) is not maked by the line that connect point and point, it connect between acupunture point and acupunture point. 2) Like blood flows in Hyul Mac(血脈), Gie(氣) flows in Kyoung Mac(經脈). The two things relate deeply each other. In a general idea or actrally Kyoung Rak(經洛), the two things sometimes accord, sometimes seperate, sometimes mix alternative. 3) Hyul Mac(血脈) and Kyoung Mac(經脈), we call it Mac(脈) entirely Kyoung Mac(經脈), is a way that manifest disease through Kyoung Mac(經脈) or a boundary that disease belongs to it method of Mac Jin(脈診) individual that disease of Kyoung Mac(經脈) is diagnosed by the jumping situation of Hyul Mac(血脈). 4) In method of Moxa, athough the pathology and the diagnostic of Mac(脈) are created by finding Mac(脈). Finding acupunture have opportunitty fot Mac Jin(脈診) and treatment. 2. Results of Kyoung Mac Mac Jin(經脈脈診) 1) In theory of kyoung Rak(經洛), disease are resumed for malfunction of Young Wee(榮衛) that flows in Kyung Rak(經洛). So to speak, in treatment of Kyoung Rak area, the purpose of diagnosis observe the situation of disease and cause. For fitting the purpose of diagnosis, the dead had esatablised four-diagnosis method mangMunMnnJeul(望聞問切), in four-diagnosis(四診法), the core is Mac Jin(脈診). 2) sip-ei Kyoung Mac Mac Jin(十二經脈診) had existed as Kyoung Mac Mac Jin(經脈脈診), it precedes Sam Bu Gu Who Jin(三部九候診). In Young Ki Gu Mac(人迎脈口診). 3) Although Bu Yang Mac(趺陽脈), So Um Mac(少陰脈) is a part of Sip-ei Kyoung Mac(十二經脈診), they developped especially because they located in the point of Won Hyul(原穴) and they are convenient for diagnose. 4) Sip-ei Kyoung Mac Mac Jin(十二經脈診), which belongs to Bu Yang Mac(趺陽脈) and So Urn Mac(少陰脈), is not important for the comming age medical books compared with Mac Kyoung(脈經). 3. Results gor Sam Bu Gu Who Jin(三部九候診) 1) Mac Jin(脈診) of Sam Bu Gu Who(三部九候), which is noted in the theory of Sam Bu Gu Who(三部九候診) of So Mun(素問), belongs to Kyoung Mac Mac Jin's(經脈脈診) geneology, Sip-ei Kyoung Mac Mac Jin(十二經脈診) is arranged, simplicated by the idealogy three talents(三才思想) in the heaven and the earth. 2) What Sam Bu Gu Jin(三部九候診) is regardded as very important in So Mun(素問), the editor of So Mun(素問) recognize the meaning that one discover disease early in this method of diagnosis. 3) After Young chu(靈樞), Nan Kyoung(難經) it is lacked the method of Sam Bu Gu Who Jin(三部九候診) in the books that treatment has changed. Sam Bu Gu Who Jin(三部九候診) based on actually clinic appropriate. 4. results for In Young Mac Gu Jin(人迎脈口診) 1) In Young Mac Gu Jin(人迎脈口診) is the method of comparative Mac Jin(脈診) according to the theory of Yin Yang(陰陽), it is presumed after Sam Bu Gu Who Jin(三部九候診), it had perished in parallel with the development of the theory of five elelment(五行). The development of the acupunture, the perishment of the treatment of negative(刺絡). 2) In Young Mac Gu Jin(人迎脈口診), Wang Suk Wha(王叔和) recreated that the left is In Young(人迎), the right is Kie Gu(氣口). In future generations by Jin Mu Taek(陳無擇) who is the writer of Sam In Bang(三因方). In Young Mac Gu Jin(人迎脈口診) is a measure for disease which classify it's inside and outside cause. 5. Results for Chon Gu Mac Jin(寸口脈診) 1) What we say Mac Jin(脈診) of Chon Gu(寸口) two means are used in commn. First case, we simply say the area of Chon Gu(寸口), second case, we say Chon Kwan Chuk Jin(寸口尺診) reducingly. Chon Gu(寸口) is the area which is the radial artery of wrist joint. What we attemp diagnose by only Chon Gu Mac(寸口脈), it is clearly shoued in the method of Nan Kyoung, five Nan(難經五難). 2) Because Jin Mac(診脈) is made in only Chon Gu(寸口), that is the area in which is concentated Kyoung Kee(經氣). That is the birth of Jin Kee(眞氣) and Jin Kee(眞氣) is related with disease. We can diagnose disease by taking Chon Gu(寸口). 3) Chuk Jin(尺診) in Nae Kyoung(難經) have two things. One is Il Chuk(一尺), the other is Chon Kwan Chu(寸關尺). 4) Chuk Chon Jin(尺寸診) is the method which diagnose the difference of point and the condition of Mac(脈) by dividing a part of Chuk(尺) in the area of Chon Gu(寸口). In Chon Gu Jin(寸口診), by introducing the theory of Yin Yang(陰陽), the method of Chon Gu Jin(寸口診) is developed by chon Gu Jin(寸口診). 5) What Chuk Kwan Chon Jin(寸關尺診) is that area of the Chon Gu(寸口) are divided fot three point, we can diagnose. By consulting Sam Bu Gu Who Jin(三部九候診), developping of the method of acupunture, utilzing the theory of five element(五行) it is devised by concentrating way of thinking of the method mac Jin(脈診) exiting. 6) Chon Kwan Chuk Jin MaC(寸關尺診脈) begin from Nae Kyoung(內徑) exiting. After Nan Kyoung(內徑), spread out widely from Mac Kyoung(脈診) of Wang Suk wha(王叔和), the future medicins followed it. Yang Hyun Jo(楊玄操) and established Chon Kwan Chuk Jin(寸關尺診) which is used widely today. This right and left Chon Kwan Chuk Jin(寸關尺診), we call it method of Yuk Bu Jung Wee Jin Mac(六部定位診脈). 7) We can think the base which presume the arrangement of the viscera for Chon Kwan Chuk(寸關尺) of the right and the left. 8) The origin, which seperate the right and the left of Mac(脈), is showed at the treory of Ji Jin Yo Dae(至眞要大論) in So Mun(素問) which Chon Chuk(寸尺) seperate the right and the left. But the method of diagnosis in Nan Kyoung(難經) have no seperation the fight and the left. Otherwise this. there is clearly writtened the seperation for the right origin of the method of Yuk Bu Jung Wee Jin Mac(六部定位診脈) seek for Cang Gong(倉公). 9) Yang Hyun Jo(楊玄操) notice that the Chuk(尺) is mentioned for Sam Cho(三焦) in the method of Mac Kyuong(脈經), Sim Po Kyung(心包經) which put together with Sam Cho(三焦) allot on this, he had established the method of Yuk Bu Jung Wee Jin Mac(六部定位診脈). 10) On the method of Paen Jak Yin Yang Mac(扁鵲陰陽脈) in Mac Kyoung(脈經), equal article exist with the theory of Pyung In Kee Sang(平人氣象論) in So Mun(素問). When Wang Suk Wha(王叔和) write Mac Kyung(脈經), we can presume that the book of Mac(脈) which Paen Jak(扁鵲) had experienced the origin have exited besides So Mun(素問), Young Chu(靈樞). If so he must be make Chon Kwan Chuk Jin(寸關尺診) very fairly standard. So Nae Kyoung(內經), which must be fllowed the method of Paen Jak Mac(扁鵲脈), do the method diagnosis of Chon Kwan Chuk(寸關尺), diagnise of disease and treat.

  • PDF

Anatomical and Physical Properties of Pitch Pine (Pinus rigida Miller) - The Characteristics of Stem, Branch, Root and Topwood - (리기다소나무(Pinus rigida Miller)의 목재해부학적(木材解剖學的) 및 물리학적성질(物理學的性質)에 관(關)한 연구(硏究) - 간(幹), 지(枝), 근(根), 초두목(梢頭木)의 특성(特性)을 중심(中心)으로 -)

  • Lee, Phil Woo
    • Journal of Korean Society of Forest Science
    • /
    • v.16 no.1
    • /
    • pp.33-62
    • /
    • 1972
  • Pitch pine (Pinus rigida Miller) in Korea has become one of the major silvicultural species for many years since it was introduced from the United States of America in 1907. To attain the more rational wood utilization basical researches on wood properties are primarily needed, since large scale of timber production from Pitch Pine trees has now been accomplishing in the forested areast hroughout the country. Under the circumustances, this experiment was carried out to study the wood anatomical, physical and mechanical properties of Pitch Pine grown in the country. Materials used in this study had been prepared by cutting the selected pitch pine trees from the Seoul National University Forests located in Suwon. To obtain and compare the anatomical and physical properties of the different parts of tree such as stem, branch, top and rootwood, this study had been divided into two categories (anatomical and physical). For the anatomical study macroscopical and microscopical features such as annual ring, intercellular cannal, ray, tracheid, ray trachid, ray parenchyma cell and pit etc. were observed and measured by the different parts (stem, branch, root and topwood) of tree. For the physical and mechanical properties the moisture content of geen wood, wood specific gravity, shrinkage, compression parallel to the grain, tension parallel and perpendicular to the grain, radial and tangential shear, bending, cleavage and hardness wree tested. According to the results this study may be concluded as follows: 1. The most important comparable features in general properties of wood among the different parts of tree were distinctness and width of annual ring, transition from spring to summerwood, wood color, odor and grain etc. In microscopical features the sizes of structural elements of wood were comparable features among the parts of tree. Among their features, length, width and thickness of tracheids, resin ducts and ray structures were most important. 2. In microscopical features among the different parts of tree stem and topwood were shown simillar reults in tissues. However in rootwood compared with other parts on the tangential surface distinctly larger ray structures were observed and measured. The maximum size of unseriate ray was attained to 27 cell ($550{\mu}$) height in length and 35 microns in width. Fusiform rays were formed occasionally the connected ray which contain one or several horizontal cannals. Branchwood was shown the same features like stemwood but the measured values were very low in comparing with other parts of tree. 3. Trachid length measured among the different parts of tree were shown largest in stem and shortest in branchwood. In comparing the tracheid length among the parts the differences were not shown only between stem and rootwood, but shown between all other parts of tree. Trachid diameters were shown widest in rootwood and narrowest in branchwood, and the differences among the different parts were not realized. Wall thickness were shown largest value in rootwood and smallest in branchwood, and the differences were shown between root and top or branchwood, and between stem and branch or top wood, but not shown between other parts of tree. 4. Moisture contents of green wood were shown highest in topwood and lowest in heartwood of stem. The differences among the different parts were recognized between top or heartwood and other parts of tree, but not between root and branchwood or root and sapwood. 5. Wood specific gravities were shown highest in stem and next order root and branchwood, but lowest in topwood. The differences were shown clearly between stemwood and other parts of tree, but not root and branchwood. However the significant difference is realized as most lowest value in topwood. 6. In compression strength parallel to the grain compared among the different parts of tree at the 14 percent of moisture content, highest strength was appeared in stem, next order branch and rootwood, but lowest in topwood. 7. In bending strength compared among the different parts of tree at the 14 percent of moisture content clearly highest strength was shown in branchwood, next order stem and root, but lowest in topwood. Though the branchwood has lower specific gravity than stemwood it was shown clearly high bending strength.

  • PDF