• 제목/요약/키워드: quantitative-correlation

검색결과 1,462건 처리시간 0.021초

Correlation Coefficient Studies on Certain Quantitative Traits in the Silkworm, Bombyx mori L.

  • Begum, A.Naseema;Yamamoto, T.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제5권1호
    • /
    • pp.44-52
    • /
    • 2002
  • To understand the relationship among different quantitative traits, correlation studies were performed by utilizing eighty-eight inbred strains of silkworm, Bombyx mori L. on twelve economic characters. Analysis resulted in correlation of 5th instar period with total larval period (r = 0.7882), cocoon weight with shell weight (r = 0.8326), shell weight with shell ratio (r = 0.5067), shell ratio with raw silk % (r = 0.7570), raw silk % with filament length (r = 0.3490), filament size (denier) with reelability (r = 0.3193) and boil-off loss % (r = 0.2792). Negative correlation was observed among filament length with filament size (r = 0.7582) and reelability with boil-off loss % (r = -0.3236). Correlation of different quantitative characters for quality silk production is discussed.

정량적, 정성적 회귀분석의 오적용과 이해 (Understanding of the Misuse Cases of Quantitative and Qualitative Regression Analysis)

  • 최성운
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2011년도 추계학술대회
    • /
    • pp.213-217
    • /
    • 2011
  • The research shows misuse cases of quantitative regression analysis used in QC circle activity and six sigma movement which presents guidelines of correct use for quality practitioners. Additionally, the qualitative regression analysis that responses nonconforming ratio of variable y, is reviewed based on misuse cases for proper use by practitioners in the field. In most cases, there are frequent errors that involve the correlation analysis or ANOVA, regardless of using quantitative regression analysis. In addition, qualitative regression analysis for the nonconforming ratio that has dependent variable of discrete and categorical data, is often applied with quantitative regression and result in ineffective quality improvement.

  • PDF

Iodine Quantification on Spectral Detector-Based Dual-Energy CT Enterography: Correlation with Crohn's Disease Activity Index and External Validation

  • Kim, Yeon Soo;Kim, Se Hyung;Ryu, Hwa Sung;Han, Joon Koo
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1077-1088
    • /
    • 2018
  • Objective: To correlate CT parameters on detector-based dual-energy CT enterography (DECTE) with Crohn's disease activity index (CDAI) and externally validate quantitative CT parameters. Materials and Methods: Thirty-nine patients with CD were retrospectively enrolled. Two radiologists reviewed DECTE images by consensus for qualitative and quantitative CT features. CT attenuation and iodine concentration for the diseased bowel were also measured. Univariate statistical tests were used to evaluate whether there was a significant difference in CTE features between remission and active groups, on the basis of the CDAI score. Pearson's correlation test and multiple linear regression analyses were used to assess the correlation between quantitative CT parameters and CDAI. For external validation, an additional 33 consecutive patients were recruited. The correlation and concordance rate were calculated between real and estimated CDAI. Results: There were significant differences between remission and active groups in the bowel enhancement pattern, subjective degree of enhancement, mesenteric fat infiltration, comb sign, and obstruction (p < 0.05). Significant correlations were found between CDAI and quantitative CT parameters, including number of lesions (correlation coefficient, r = 0.573), bowel wall thickness (r = 0.477), iodine concentration (r = 0.744), and relative degree of enhancement (r = 0.541; p < 0.05). Iodine concentration remained the sole independent variable associated with CDAI in multivariate analysis (p = 0.001). The linear regression equation for CDAI (y) and iodine concentration (x) was y = 53.549x + 55.111. For validation patients, a significant correlation (r = 0.925; p < 0.001) and high concordance rate (87.9%, 29/33) were observed between real and estimated CDAIs. Conclusion: Iodine concentration, measured on detector-based DECTE, represents a convenient and reproducible biomarker to monitor disease activity in CD.

Assessment of the Severity of Coronavirus Disease: Quantitative Computed Tomography Parameters versus Semiquantitative Visual Score

  • Xi Yin;Xiangde Min;Yan Nan;Zhaoyan Feng;Basen Li;Wei Cai;Xiaoqing Xi;Liang Wang
    • Korean Journal of Radiology
    • /
    • 제21권8호
    • /
    • pp.998-1006
    • /
    • 2020
  • Objective: To compare the accuracies of quantitative computed tomography (CT) parameters and semiquantitative visual score in evaluating clinical classification of severity of coronavirus disease (COVID-19). Materials and Methods: We retrospectively enrolled 187 patients with COVID-19 treated at Tongji Hospital of Tongji Medical College from February 15, 2020, to February 29, 2020. Demographic data, imaging characteristics, and clinical data were collected, and based on the clinical classification of severity, patients were divided into groups 1 (mild) and 2 (severe/critical). A semiquantitative visual score was used to estimate the lesion extent. A three-dimensional slicer was used to precisely quantify the volume and CT value of the lung and lesions. Correlation coefficients of the quantitative CT parameters, semiquantitative visual score, and clinical classification were calculated using Spearman's correlation. A receiver operating characteristic curve was used to compare the accuracies of quantitative and semi-quantitative methods. Results: There were 59 patients in group 1 and 128 patients in group 2. The mean age and sex distribution of the two groups were not significantly different. The lesions were primarily located in the subpleural area. Compared to group 1, group 2 had larger values for all volume-dependent parameters (p < 0.001). The percentage of lesions had the strongest correlation with disease severity with a correlation coefficient of 0.495. In comparison, the correlation coefficient of semiquantitative score was 0.349. To classify the severity of COVID-19, area under the curve of the percentage of lesions was the highest (0.807; 95% confidence interval, 0.744-0.861: p < 0.001) and that of the quantitative CT parameters was significantly higher than that of the semiquantitative visual score (p = 0.001). Conclusion: The classification accuracy of quantitative CT parameters was significantly superior to that of semiquantitative visual score in terms of evaluating the severity of COVID-19.

Quantitative Definitions of Collaborative Research Fields in Science and Engineering

  • Schwartz, Mathew;Park, Kwisun;Lee, Sung-Jong
    • Asian Journal of Innovation and Policy
    • /
    • 제5권3호
    • /
    • pp.251-274
    • /
    • 2016
  • Practical methodology for categorizing collaborative disciplines or research in a quantitative manner is presented by developing a Correlation Matrix of Major Disciplines (CMMD) using bibliometric data collected between 2009 and 2014. First, 21 major disciplines in science and engineering are defined based on journal publication frequency. Second, major disciplines using a comparing discipline correlation matrix is created and correlation score using CMMD is calculated based on an analyzer function that is given to the matrix elements. Third, a correlation between the major disciplines and 14 research fields using CMMD is calculated for validation. Collaborative researches are classified into three groups by partially accepting the definition of pluri-discipline from peer review manual, European Science Foundation, inner-discipline, inter-discipline and cross-discipline. Applying simple categorization criteria identifies three groups of collaborative research and also those results can be visualized. Overall, the proposed methodology supports the categorization for each research field.

성인의 식이섭취 조사를 위한 반정량 식품섭취빈도조사지의 타당도 연구 -건강증진센터 내원 성인을 대상으로 - (A Study on Validity of a Semi-Quantitative Food Frequency Questionnaire for Korean Adults)

  • 심지선;오경원;서일;김미양;손춘영;이은주;남정모
    • 대한지역사회영양학회지
    • /
    • 제7권4호
    • /
    • pp.484-494
    • /
    • 2002
  • This study was conducted to validate the semi-quantitative food frequency questionnaire that was developed to assess the intakes of fatty acids, as well as energy, carbohydrates, fat, protein, minerals and vitamins in Korean adults. The validity of the semi-quantitative food frequency questionnaire was tested on 78 subjects (31 men,47 women) aged 34 to 66 years. The semi-quantitative food frequency questionnaire included 93 food items and was validated on two 3-day dietary records. The mean intakes and the Spearman Correlation Coefficients between the semi-quantitative food frequency questionnaire and the two 3-day dietary records were analyzed for each nutrient and food group level. The mean nutrient intakes obtained from the semi-quantitative food frequency questionnaire were estimated to be greater than those of the two 3-day dietary records. The Spearman Correlation Coefficients between the energy-adjusted nutrient intakes from the semi-quantitative food frequency questionnaire and the two 3-day dietary records ranged from 0.24 for polyunsaturated fatty acids to 0.55 for fat in men and from 0.29 for polyunsaturated fatty acids to 0.55 for saturated fatty acids in women, respectively. The Spearman Correlation Coefficients for food intake ranged from 0.11 for teas and beverages to 0.58 for grains and their products in men,-0.04 for potatoes and starches to 0.73 for milk and dairy products in women. Foods consumed regularly had lower intra-person variation and tended to have higher observed correlation coefficients. These results indicate that the semi-quantitative food frequency questionnaire is a useful tool for estimating nutrient intakes, particularly of total fat and saturated fatty acid intakes.

Quantitative Assessment of Infrared Analysis of Concrete Admixtures

  • Casale, Anthony J. III;Doukakis, Johanna;Najm, Husam;Davis, Kimberly
    • International Journal of Concrete Structures and Materials
    • /
    • 제7권3호
    • /
    • pp.203-214
    • /
    • 2013
  • This study investigates quantitative methods for assessment of infrared analysis of concrete admixtures using correlation coefficients by performing IR scans following the ASTM C494/C494M-11 specifications. In order to achieve this goal, numerous IR scans were performed on specimens supplied by the manufacturer from different batches to ensure uniformity and equivalency. These scans were then analyzed to create correlation coefficients for each admixture. The correlation coefficients were used to quantitatively evaluate and interpret IR Scans of job samples. The study focused on 23 most commonly used concrete admixtures by the New Jersey Department of Transportation (NJDOT). They include air-entrainers, accelerators, retarders, water reducers, and other combinations of these admixtures. Their correlation coefficients were established by analyzing a total of 12 scans of each admixture from three different batches supplied by the manufacturer at different time intervals. In order to validate the obtained correlation coefficients and establish a target correlation, job samples were tested and compared to the obtained correlations. The study also evaluated the effects of drying time and using different types of KBr on correlation coefficients.

In Vivo Quantitative Analysis of PKA Subunit Interaction and cAMP Level by Dual Color Fluorescence Cross Correlation Spectroscopy

  • Park, Hyungju;Pack, Changi;Kinjo, Masataka;Kaang, Bong-Kiun
    • Molecules and Cells
    • /
    • 제26권1호
    • /
    • pp.87-92
    • /
    • 2008
  • We employed dual color Fluorescence Cross Correlation Spectroscopy (FCCS) to measure the interaction between PKA regulatory (RII) and catalytic subunits (CAT) in living cells. Elevation of intracellular cAMP with forskolin decreased the cross-correlation amplitude between RFP-fused RII (RII -mRFP) and GFP-fused CAT (CAT-EGFP) by 50%, indicating that cAMP elevation leads to dissociation of RII-CAT complexes. Moreover, diffusion coefficient analysis showed that the diffusion rate of CAT-EGFP was significantly increased, suggesting that the decreased RII-CAT association caused by cAMP generated free CAT subunits. Our study demonstrates that in vivo FCCS measurements and their quantitative analysis permit one not only to directly quantify protein-protein interactions but also to estimate changes in the intracellular cAMP concentration.

Detection of proximal caries using quantitative light-induced fluorescence-digital and laser fluorescence: a comparative study

  • Yoon, Hyung-In;Yoo, Min-Jeong;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.432-438
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the in vitro validity of quantitative light-induced fluorescence-digital (QLF-D) and laser fluorescence (DIAGNOdent) for assessing proximal caries in extracted premolars, using digital radiography as reference method. MATERIALS AND METHODS. A total of 102 extracted premolars with similar lengths and shapes were used. A single operator conducted all the examinations using three different detection methods (bitewing radiography, QLF-D, and DIAGNOdent). The bitewing x-ray scale, QLF-D fluorescence loss (${\Delta}F$), and DIAGNOdent peak readings were compared and statistically analyzed. RESULTS. Each method showed an excellent reliability. The correlation coefficient between bitewing radiography and QLF-D, DIAGNOdent were -0.644 and 0.448, respectively, while the value between QLF-D and DIAGNOdent was -0.382. The kappa statistics for bitewing radiography and QLF-D had a higher diagnosis consensus than those for bitewing radiography and DIAGNOdent. The QLF-D was moderately to highly accurate (AUC = 0.753 - 0.908), while DIAGNOdent was moderately to less accurate (AUC = 0.622 - 0.784). All detection methods showed statistically significant correlation and high correlation between the bitewing radiography and QLF-D. CONCLUSION. QLF-D was found to be a valid and reliable alternative diagnostic method to digital bitewing radiography for in vitro detection of proximal caries.

갑상샘 스캔 정량분석을 통한 갑상샘 섭취율 동시계측법 연구 (Study of Simultaneous Counting of Thyroid Uptake with Quantitative Analysis of Thyroid Scans)

  • 김정수;김근우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권5호
    • /
    • pp.401-408
    • /
    • 2023
  • Thyroid uptake measurements can be subject to measurement errors due to the scoping and positioning of the thyroid gland. To compensate for these limitations, the clinical utility of the thyroid simultaneous counting method as an alternative to thyroid uptake measurement was analyzed and evaluated experimentally through quantitative analysis of images acquired after thyroid scanning. Experimental data were obtained using a Gamma camera (GE infinia), a thyroid uptake system (KOROID 1), and a thyroid neck phantom. Based on the thyroid uptake rate of 1-5% according to the protocol of thyroid scan test (99mTcO4 - , 370 MBq) in normal results, 99mTcO4 - was set in the range of 3.7-18.5 MBq (Matrix: 256×256, Scan time: 1 min, collimator: pin hole, phantom-collimator distances: 7 cm). The acquired images were corrected for the attenuation of isotopes due to the set-up time and half-life by applying the Auto Region of interest (ROI) drawing system, and the significance of the experimental results was evaluated by Multiple linear regression analysis (SPSS, ver. 22, IBM). The thyroid uptake rate showed a significant correlation between the dose and the measured counts when using the thyroid uptake system equipment. Meanwhile, the quantitative analysis counts of phantom images using Gamma camera also showed a significant correlation. Thus confirmed that the correlation between these two experiments was statistically significant (P<0.05). The simultaneous counting protocol, which indirectly measures thyroid uptake from thyroid scans, is likely to be clinically relevant if complemented by additional studies with different variables in patients with thyroid disease.