• Title/Summary/Keyword: quantitative test

Search Result 2,292, Processing Time 0.035 seconds

HABIT : Cancer Diagnosis System (HABIT : 질병 진단 시스템)

  • Kim, Gi-Seong;On, Seung-Yeop;Gang, Gyeong-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.898-902
    • /
    • 2003
  • In this paper we proposes a new technique for identification of breast cancer by classification of proteome pattern generated from 2-D polyacrylamide gel electrophoresis (2-D PAGE) and development of cancer diagnosis system : HABIT. Proteome patterns reflect the underlying pathological state of a human organ and it is believed that the anomalies or diseases of human organs are identified by the analysis or classification of the patterns. Proteome patterns consist of quantitative information of the spots such as their size, position, and density in the proteome image produced from 2-D PAGE, for the Image mining of proteome pattern, SVM(support vector machine) and GA(genetic algorithm) are used to generate a decision model for the identification of breast cancer The decision model was then used to classify an independent set of test proteome patterns into the affecter and unaffecter classes. The proposed technique was tested by actual clinical test samples and showed a good performance of a hit ratio of 90%.

  • PDF

Experimental Study of the Role of Gas-Liquid Scheme Injector as an Acoustic Resonator in a Combustion Chamber

  • Kim Hak-Soon;Sohn Chae-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.896-904
    • /
    • 2006
  • In a liquid rocket engine, the role of gas-liquid scheme injector as an acoustic resonator or absorber is studied experimentally for combustion stability by adopting linear acoustic test. The acoustic-pressure signals or responses from the chamber are monitored by acoustic amplitude. Acoustic behavior in a rocket combustor with a single injector is investigated and the acoustic-damping effect of the injector is evaluated for cold condition by the quantitative parameter of damping factor as a function of injector length. From the experimental data, it is found that the injector can play a significant role in acoustic damping when it is tuned finely. The optimum tuning-length of the injector to maximize the damping capacity is near half of a full wavelength of the first longitudinal overtone mode traveling in the injector with the acoustic frequency intended for damping in the chamber. When the injector has large diameter, the phenomenon of the mode split is observed near the optimum injector length and thereby, the acoustic-damping effect of the tuned injectors can be degraded.

Seismic Test of a Full Scale Model of Five-Story Stone Pagoda of Sang-Gye-Sa (쌍계사 오층석탐 실물 크기 모델의 지진시험)

  • 김재관
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.388-395
    • /
    • 1999
  • There occurred a moderate size earthquake of M=5 at Whagae-Myun Hadong-Gun Kyongsangnam-Do of Korea, It caused severe damage to the buildings and other structures is Sang-Gye-Sa a famous and beautiful Buddhist Temple, The 5-story stone pagoda was standing in front of Keumdang. The top component tipped over and fell to the ground during the earthquake. In order to have accurate and quantitative estimate of the intensity of earthquake a full-scale replica is made through rigorous verification process, The completed model was mounted on the shaking table and subjected to th seismic tests. It was observed that the top component overturned at 0.16 G of EPGA when the NS component of the 1940 el Centro earthquake records was used as the input motion. A brief history of this project is presented and important test results are report6ed and their implication is discussed.

  • PDF

Benzotriazol-1-yl Diethyl Phosphate and Benzotriazol-1-yl Diphenyl Phosphate. New Convenient Reagents for the Peptide Synthesis

  • Kim, Sung-Gak;Chang, He-Ung;Ko, Young-Kwan
    • Bulletin of the Korean Chemical Society
    • /
    • v.8 no.6
    • /
    • pp.471-475
    • /
    • 1987
  • Benzotriazol-1-yl Diethyl phosphate and benzotriazol-1-yl diphenyl phosphate were conveniently prepared in essentially quantitative yields by the reaction of diethyl chlorophosphate and diphenyl chlorophosphate with equal amounts of 1-hydroxybenzotriazole and triethylamine in tetrahydrofuran at room temperature, respectively. Benzotriazol-1-yl diethylphosphate was effective for the preparation of amides from carboxylic acids amines. Young test and Anderson test for racemization studies using benzotriazol-1-yl diethyl phosphate were investigated and practically no racemization occurred. However, racemization occurred to some extent during coupling of Z-Phe-Val-OH with Pro-OBu. Several dipeptides and tripeptides were prepared without little racemization using benzotriazol-1-yl diethyl phosphate. Benzotriazol-1-yl diphenyl phosphate was less effective than benzotriazol-1-yl diethyl phosphate in terms of the degree of racemization.

Neurological aspects of anhidrosis: differential diagnoses and diagnostic tools

  • Park, Kee Hong;Park, Ki-Jong
    • Annals of Clinical Neurophysiology
    • /
    • v.21 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • Anhidrosis refers to the condition in which the body does not respond appropriately to thermal stimuli by sweating. Sweating plays an important role in maintaining the body temperature, and its absence should not be overlooked since an elevated body temperature can cause various symptoms, even leading to death when uncontrolled. The various neurological disorders that can induce anhidrosis make a detailed neurological evaluation essential. The medication history of the patient should also be checked because anhidrosis can be caused by various drugs. The tests available for evaluating sweating include the quantitative sudomotor axon reflex sweat test, thermoregulatory sweat test, sympathetic skin response, and electrochemical skin conductance. Pathological findings can also be checked directly in a skin biopsy. This review discusses the differential diagnosis and evaluation of anhidrosis.

Small Fiber Neuropathy and Postural Orthostatic Tachycardia Syndrome after Human Papillomavirus Vaccination (사람유두종바이러스 백신접종 후 발생한 소섬유신경병과 기립빈맥증후군)

  • Lee, Chaewon;Lim, Young-Min;Ko, Myung-A;Kim, Hyunjin;Kim, Kwang-Kuk
    • Journal of the Korean neurological association
    • /
    • v.36 no.4
    • /
    • pp.318-321
    • /
    • 2018
  • We describe a 44-year-old woman with paresthesia, fatigue, and palpitation, 10 days after human papillomavirus (HPV) vaccination. The quantitative sensory test showed abnormal detection threshold in her foot. Tilt test result indicated postural orthostatic tachycardia syndrome. Symptoms were improved after immunomodulating therapy, pain control drug, and oral beta blocker medication. This is first case report for small fiber neuropathy and autonomic dysfunction after HPV vaccination in Korea.

Effects of Fit Factor and Visual Acuity of Eyeglasses Wearers when Wearing Particulate Filtering Facepiece Respirators (안경착용자 방진마스크 착용 시 밀착계수와 착용시력에 미치는 영향)

  • Eoh, Won Souk;Shin, Chang Sup
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.105-115
    • /
    • 2020
  • This study compares the difference of fit factors (FF) and visual acuity according to masks and eyeglasses preferences for 54 participants. We the precautions and behaviors of discomfort when wearing masks of eyewear wearers. Contact lens discomfort and priority action of complaints was investigated Glasses fitting factors is Optical Center Height(OH), Vertex Distance(VD) and Pantoscopic Angle(PA). We measured those factors and expressed by the ratio of standard point and change point. Quantitative fit factor was measured by Portacount Pro+ 8038. Also, we selected to 6 exercises among 8 exercises OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The pass/ fail criterion of FF was set at 100. Visual acuity(VA) test chart is developed by Chunsuk Han was used, Descriptive statistics was performed. Descriptive statistics(SAS ver 9.2), it is used geometric means, Wilcoxon analysis(P=0.05) When wearing the mask preferentially, fit factor(FF) was high according to the step of glasses fitting parameter. on the other hand, when the glasses first choice, the visual acuity(VA) was high. there was no significant difference. In the case of fit factor (FF), mask first choice/ glasses first choice is OH (p=0.671/ p=0.332), VD (p=0.602/ p=0.571) and PA (p=0.549/ p=0.607). Visual acuity (VA), mask first choice/ glasses first choice is OH (p=0.753/ p=0.386), VD (p=0.815/ p=0.557) and PA (p=0.856/ p=0.562). The workers of workplace and office chose glasses but occupational health workers and students chose mask. In case of discomforts, it was suggested to remove the mask and tolerate discomforts. The main discomforts and usual action of lens were dryness, hyperemia, foreign body sensation, ophthalmodynia, decreased vision and glasses wearing. Therefore, it is necessary to develop a mask wearing method education program considering glasses fitting and develop a hybrid model that minimizes inconvenience when wearing glasses and a mask at the same time.

Cytomegalovirus Infection under a Hybrid Strategy in Pediatric Liver Transplantation: A Single-Center Experience

  • Kim, Ryung;Joung, Dai;Lee, Sunghee;Jeong, Insook;Oh, Seak Hee;Namgoong, Jung-Man;Kim, Dae Yeon;Kim, Kyung Mo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.20 no.3
    • /
    • pp.178-185
    • /
    • 2017
  • Purpose: To evaluate the outcomes of a hybrid prophylactic strategy to prevent cytomegalovirus (CMV) disease in pediatric liver transplantation (LT) patients. Methods: CMV DNAemia was regularly monitored by quantitative nucleic acid amplification test (QNAT) and was quantified in all children. CMV infection and disease were defined according to the International Consensus Guidelines. The hybrid strategy against CMV infection consisted of universal 3-week prophylaxis and preemptive treatment of intravenous ganciclovir regardless of the recipient's serostatus. Results: A total of 143 children who underwent living donor LT were managed using the hybrid strategy. The overall incidence of CMV infection by QNAT was 48.3% (n=69/143). The highest CMV DNAemia positivity was observed in 49.2% (n=60/122) of children in the D+/R+ group, followed by 46.7% (n=7/15) in the D+/R- group. CMV disease was noted in 26.1% (n=18/69) patients. Forty-three (62.3%) children had undergone preemptive therapy consisting of intravenous ganciclovir. No symptomatic patients developed tissue-invasive disease, resulting in no CMV-associated mortality. Conclusion: The incidence of CMV infection was high in pediatric LT patients despite the hybrid strategy. However, tissue-invasive disease in pediatric LT did not occur.

Effect of Bonding Process Conditions on the Interfacial Adhesion Energy of Al-Al Direct Bonds (접합 공정 조건이 Al-Al 접합의 계면접착에너지에 미치는 영향)

  • Kim, Jae-Won;Jeong, Myeong-Hyeok;Jang, Eun-Jung;Park, Sung-Cheol;Cakmak, Erkan;Kim, Bi-Oh;Matthias, Thorsten;Kim, Sung-Dong;Park, Young-Bae
    • Korean Journal of Materials Research
    • /
    • v.20 no.6
    • /
    • pp.319-325
    • /
    • 2010
  • 3-D IC integration enables the smallest form factor and highest performance due to the shortest and most plentiful interconnects between chips. Direct metal bonding has several advantages over the solder-based bonding, including lower electrical resistivity, better electromigration resistance and more reduced interconnect RC delay, while high process temperature is one of the major bottlenecks of metal direct bonding because it can negatively influence device reliability and manufacturing yield. We performed quantitative analyses of the interfacial properties of Al-Al bonds with varying process parameters, bonding temperature, bonding time, and bonding environment. A 4-point bending method was used to measure the interfacial adhesion energy. The quantitative interfacial adhesion energy measured by a 4-point bending test shows 1.33, 2.25, and $6.44\;J/m^2$ for 400, 450, and $500^{\circ}C$, respectively, in a $N_2$ atmosphere. Increasing the bonding time from 1 to 4 hrs enhanced the interfacial fracture toughness while the effects of forming gas were negligible, which were correlated to the bonding interface analysis results. XPS depth analysis results on the delaminated interfaces showed that the relative area fraction of aluminum oxide to the pure aluminum phase near the bonding surfaces match well the variations of interfacial adhesion energies with bonding process conditions.

Change of Pain Threshold and Nociceptive Flexion Reflex of Hyperalgesia Rat by High Voltage Pulsed Current (고전압맥동전류가 통각과민 백서의 통각역치 및 유해성 굴곡반사에 미치는 영향)

  • Kim, Su-Hyon;Moon, Dal-Ju;Choi, Sug-Ju;Jung, Dae-In;Lee, Jung-Woo;Jeong, Jin-Gyu;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.2
    • /
    • pp.25-34
    • /
    • 2006
  • Purpose: This study conducted quantitative sensory test and nociceptive flexion reflex(NFR) measurement to examine degree of pain depending on polarity of high voltage pulsed current(HVPC) of hyperalgesia site in hyperalgesia rat by local thermal injury. mechanical pain threshold, thermal pain threshold and root mean square of NFR were measured. Methods: This study was conducted with control group I of hyperalgesia rat at hind paw by thermal injury and experimental groups divided into cathodal HVPC group II, anodal HVPC group III and alternate HVPC group IV. It measured pain threshold and root mean square(RMS) of NFR and obtained the following results. Results: Mechanical pain threshold of hyperalgeisa site was significantly increased at groups II, III and IV applying HVPC group compared to control group, but there was no difference among HVPC groups. Thermal pain threshold of hyperalgesia site showed a significant increase in group II. Group III showed significant difference after 4 days of hyperalgesia. RMS of NFR at hyperalgeisa site was significantly reduced in group II after 2 days of hyperalgesia. Group III showed significant decrease after 5 and 6 days of hyperalgesia. Conclusion: Consequently it was found that application of HVPC of hyperalgesia site increased pain threshold at hyperalgesia site by mechanical stimuli and thermal stimuli. NFR by electrical stimuli was similar to pain threshold by mechanical stimuli. Effects by polarity of HVPC showed the greatest reduction of hyperalgesia when cathodal electrode was used.

  • PDF