• 제목/요약/키워드: quality control chart

검색결과 260건 처리시간 0.026초

Clinical image quality evaluation for panoramic radiography in Korean dental clinics

  • Choi, Bo-Ram;Choi, Da-Hye;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Bae, Kwang-Hak;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • 제42권3호
    • /
    • pp.183-190
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the level of clinical image quality of panoramic radiographs and to analyze the parameters that influence the overall image quality. Materials and Methods: Korean dental clinics were asked to provide three randomly selected panoramic radiographs. An oral and maxillofacial radiology specialist evaluated those images using our self-developed Clinical Image Quality Evaluation Chart. Three evaluators classified the overall image quality of the panoramic radiographs and evaluated the causes of imaging errors. Results: A total of 297 panoramic radiographs were collected from 99 dental hospitals and clinics. The mean of the scores according to the Clinical Image Quality Evaluation Chart was 79.9. In the classification of the overall image quality, 17 images were deemed 'optimal for obtaining diagnostic information,' 153 were 'adequate for diagnosis,' 109 were 'poor but diagnosable,' and nine were 'unrecognizable and too poor for diagnosis'. The results of the analysis of the causes of the errors in all the images are as follows: 139 errors in the positioning, 135 in the processing, 50 from the radiographic unit, and 13 due to anatomic abnormality. Conclusion: Panoramic radiographs taken at local dental clinics generally have a normal or higher-level image quality. Principal factors affecting image quality were positioning of the patient and image density, sharpness, and contrast. Therefore, when images are taken, the patient position should be adjusted with great care. Also, standardizing objective criteria of image density, sharpness, and contrast is required to evaluate image quality effectively.

핵의학 검체검사 정도관리의 개선을 위한 Westgard Multi-Rules의 적용 (Application of Westgard Multi-Rules for Improving Nuclear Medicine Blood Test Quality Control)

  • 정흥수;배진수;신용환;김지영;석재동
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.115-118
    • /
    • 2012
  • Levey-Jennings 정도관리는 측정치가 관리 허용치(평균 ${\pm}2SD$ 또는 ${\pm}3SD$)를 벗어나는 우연오차만 관리를 했었다면, Westgard Multi-Rules 정도관리는 우연오차와 계통오차의 분리분석을 할 수 있고 복합적용이 가능해 병원 인증 내부정도관리에서도 적극 권장하고 있다. 하지만 검체검사 정도관리에서는 kit 내 같은 기질의 정도관리 물질을 사용해 계통오차의 인지가 쉽지 않고 잦은 농도 변경으로 목표치 설정이 어려워 Westgard Multi-Rules의 적용이 힘들었다. 따라서 본 연구는 정도관리 물질을 상용화된 제 3의 물질을 사용해 신뢰성 있는 목표치를 산출하고 Westgard Multi-Rules을 적용함으로써 정도관리를 개선하고자 한다. 갑상선 검사인 Total T3를 대상으로 정도관리 물질을 B사의 Immunoassay Plus Control Level 1, 2, 3를 사용하여 ${\pm}2SD$를 벗어난 값을 제외한 1개월 동안 295회 데이터의 평균값으로 목표치를 설정하였다. 그리고 20일간 총 194회 실험의 정도관리 물질 측정치를 표준편차 지수를 이용하여 하나의 관리도상에 놓고 Westgard Multi-Rules 중 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T의 규칙들을 적용하여 우연오차와 계통오차를 분리하여 분석하였다. Total T3의 목표치는 정도관리 물질 1, 2, 3번이 각각 84.2 ng/dl, 156.7 ng/dl, 242.4 ng/dl로 설정되었고 표준편차는 각각 11.22 ng/dl, 14.52 ng/dl, 14.52 ng/dl로 설정되었다. 설정된 목표치를 기준으로 Westgard Multi-Rules을 적용한 뒤 유형을 분석한 결과 우연오차인 12s가 48회, 13s가 13회, R4s가 6회로 분석되었고 계통오차인 22s는 10회, 41s가 11회, 2 of 32s가 17회, $10\bar{x}$가 10회로 분석되었으며 7T는 적용되어지지 않았다. 통제 불가능한 우연오차의 유형들은 전체실험과정을 재확인하고 재검사 비중을 높이는 등의 조치를 취하였으며 통제 가능한 계통오차의 유형들은 원인을 찾아 조치사항 양식에 기록하고 필요 시 내부정도관리 위원회에 보고하였다. 상용화된 제 3의 물질을 정도관리 물질로 사용하고 목표치를 설정함에 따라 하나의 관리도 상에서 3가지 정도관리 물질에 대한 Westgard Multi-Rules의 적용이 가능하게 되었고, 그 결과 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T 규칙들의 분석으로 우연오차와 계통오차의 정밀분석이 가능해 졌다. 또한 ${\pm}3SD$ 내의 모든 데이터를 분석 할 수 있어 Error 검출을 최대화 할 수 있게 되었다. 이와 같이 체계적으로 Westgard Multi-Rules을 적용한 정도관리는 검체검사의 정도관리에 질적 향상을 가져다 줄 것이다.

  • PDF

어패럴 CAD System의 활용화 방안 연구(II) - 테일러드 쟈켓 설계 과정을 중심으로 - (A Study on the Application of the Apparel CAD System(II))

  • 남윤자;이형숙;조영아
    • 한국의류학회지
    • /
    • 제18권1호
    • /
    • pp.43-56
    • /
    • 1994
  • The Purpose of this study was to utilize of CAD System in pattern making process for women's apparel. The automation by the use of CAD System provides the higher accuracy and efficiency in pattern making process. AccuMark 300 System was used. for .this study. The results from this study were as follows . 1. New size spec chart and grading pitch chart were developed based on the data analysis and fitting tests for female college students. 2. New jacket block was developed based on the torso length sloper 3. Automatic grading of jacket block have been developed by creation and modification of grading rules of block pattern. 4. Pattern Design Systyem(P/D/S) were enabled to be constructed directly form a block pattern by modifications to existing styled pattern. 5. Original master pattern was generated by P/D/S menu option. 6. Production pattem added seam allowance, notchs was generated by P/D/S menu option. 7 Interative maker making process have enabled to save a wide range of time and space. 8. Measurement of garment by P/D/S measuring tools is to utilize in garment costing, quality control.

  • PDF

다변량 공정 모니터링에서 이상신호 발생시 원인 식별에 관한 연구 (Notes on identifying source of out-of-control signals in phase II multivariate process monitoring)

  • 이성임
    • 응용통계연구
    • /
    • 제31권1호
    • /
    • pp.1-11
    • /
    • 2018
  • 최근 다변량 공정관리는 다양한 응용 분야에서 중요해지고 있는 추세이다. 예를 들어, 제조 산업 분야에서는 다변량 품질특성치를 동시에 모니터링할 필요가 있다. 그러나, 다변량 관리도는 이상신호가 발생한 경우 그 원인이 되는 개별적인 변수를 식별하기가 어렵기 때문에, 실제로는 기대만큼 유용하게 쓰이고 있지 않은 형편이다. 이에 본 논문에서는 새로운 관측치에 대한 개별적인 신뢰구간을 사용하여 이상신호의 원인을 탐지하는 세 가지 방법을 소개하고, 시뮬레이션 연구를 통해 이상신호의 원인이 되는 개별적인 변수를 식별하고 해석하는 데 있어 주의할 점이 무엇인지 살펴보기로 한다.

발화력지수(醱化力指數)가 유리색조(色調)에 미치는 영향(影響) (The Effects of Glass Color Tone by Oxidation Power Index)

  • 박은성;박병기
    • 품질경영학회지
    • /
    • 제16권1호
    • /
    • pp.1-7
    • /
    • 1988
  • The most important element upon the quality of family glass products is the color of glass, which is the first object of consumers concern in purchasing. Therefore, colorless and transparent color tone can level up the additional value of the products. But we have produced the glass products in a large quantity by using the automatic tank brazier, chronic problem has been left over the color tone. By compounding and analizing the management techniques applied by peculiar technique and design of experiments pertinently, and by adjusting the decoloring composition ratio, we can contribute to improvement of color tone as well as to the cost reduction by diminishing the unnecessary decoloring agent. Intangible effect was the securing the superiority of quality home and abroad with the improvement of color tone and was taking a triangular position the factors influencing the glass decoloring which had been an unexhausted field. Tangible effect was the reduction of decoloring cost by diminishing the unnecessary oxidant. We registered the optimal composition ratio condition which was searched by applicating the design of experiments. To maintain good color tone, we manage the degree of purity, the most important thing among the items of color tone, continuously by control chart and it has maintained steady state now.

  • PDF

휴대용 카메라 모듈(CCM) 제조 라인에 대한 데이터마이닝 기반 품질관리시스템 구축 (Building the Quality Management System for Compact Camera Module(CCM) Assembly Line)

  • 유성진;강부식;홍한국
    • 지능정보연구
    • /
    • 제14권4호
    • /
    • pp.89-101
    • /
    • 2008
  • 제조 분야에서 품질관리를 위해 가장 많이 사용되는 도구는 관리도이다. 하지만 휴대용 카메라 모듈과 같은 소형 전자부품의 제조 라인은 자동화되어 여러 개의 공정이 유기적으로 연결되어 있는 경우 관리도의 적용이 쉽지 않다. 이러한 문제점을 해결하기 위해 공정의 흐름을 파악할 수 있는 모니터링체계와 수율 예측 및 주요공정 변수 파악 등의 주요 공정 파라메터 추출 체계로 구성된 데이터마이닝 기반 품질관리시스템을 구축하고자 한다. 데이터마이닝을 위해 품질관리시스템은 의사결정나무, 신경망, 패턴분석 등의 모듈을 사용한다. 제안된 시스템을 통해 제조 공정은 안정적인 품질의 유지 및 공정 이상 유무의 신속한 파악, 수율 예측 등 품질관리를 위한 유용한 정보를 제공하고 공정의 신뢰성을 높이는데 기여할 수 있을 것이다.

  • PDF

통계적 품질관리와 ISO 9000 시리즈와의 연결시스템 개발 (Developing the Linkage System Between Statistical Quality Control and ISO 9000 Series)

  • 김형준;오성균
    • 한국컴퓨터정보학회논문지
    • /
    • 제3권4호
    • /
    • pp.174-192
    • /
    • 1998
  • 오늘날의 품질보증체제 하에서는 SQC와 동시에 ISO 9000 시리즈를 활용할 수 있는 컴퓨터 시스템이 절실히 요구되고 있다. 이는 SQC가 전문적인 통계적 지식을 필요로 하고 있기 때문에 사용상 매우 불편하여 실무단계에서 적용하기에는 한계점이 있다. 따라서 본 연구에서는 SQC와 ISO 9000 시리즈를 동시에 관리할 수 있으면서 또한 전문적인 통계적 지식이 없는 경우에도 이용할 수 있는 소프트웨어를 개발하고자 한다. 이를 위해 연구내용을 크게 ISO 9000 시스템과 SQC 시스템으로 나누되, ISO 시스템의 내용은 기본 시스템의 설계, 검사 및 시험, 부적합품 추적, 불량분석 등이며, SQC 시스템의 경우 품질관리에서 공통으로 많이 사용되는 관리도, 추.검정, 실험계획법으로 제한하였다. 본 연구의 기대효과는품질경영체제의 확립, 품질의식의 변화, 대 고객만족과 신뢰도 향상 등이며, 특히 제조업 중심의 중소기업에 유용하게 사용될 것이라고 기대된다.

  • PDF

An Economic Design of the Integrated Process Control Procedure with Repeated Adjustments and EWMA Monitoring

  • Park Changsoon;Jeong Yoonjoon
    • 한국통계학회:학술대회논문집
    • /
    • 한국통계학회 2004년도 학술발표논문집
    • /
    • pp.179-184
    • /
    • 2004
  • Statistical process control (SPC) and engineering process control (EPC) are based on different strategies for process quality improvement. SPC reduces process variability by detecting and eliminating special causes of process variation, while EPC reduces process variability by adjusting compensatory variables to keep the quality variable close to target. Recently there has been need for an integrated process control (IPC) procedure which combines the two strategies. This article considers a scheme that simultaneously applies SPC and EPC techniques to reduce the variation of a process. The process disturbance model under consideration is an IMA(1,1) model with a location shift. The EPC part of the scheme adjusts the process, while the SPC part of the scheme detects the occurrence of a special cause. For adjusting the process repeated adjustment is applied by compensating the predicted deviation from target. For detecting special causes the two kinds of exponentially weighted moving average (EWMA) control chart are applied to the observed deviations: One for detecting location shift and the other for detecting increment of variability. It was assumed that the adjustment of the process under the presence of a special cause may change any of the process parameters as well as the system gain. The effectiveness of the IPC scheme is evaluated in the context of the average cost per unit time (ACU) during the operation of the scheme. One major objective of this article is to investigate the effects of the process parameters to the ACU. Another major objective is to give a practical guide for the efficient selection of the parameters of the two EWMA control charts.

  • PDF

Embedded RF Test Circuits: RF Power Detectors, RF Power Control Circuits, Directional Couplers, and 77-GHz Six-Port Reflectometer

  • Eisenstadt, William R.;Hur, Byul
    • Journal of information and communication convergence engineering
    • /
    • 제11권1호
    • /
    • pp.56-61
    • /
    • 2013
  • Modern integrated circuits (ICs) are becoming an integrated parts of analog, digital, and radio frequency (RF) circuits. Testing these RF circuits on a chip is an important task, not only for fabrication quality control but also for tuning RF circuit elements to fit multi-standard wireless systems. In this paper, RF test circuits suitable for embedded testing are introduced: RF power detectors, power control circuits, directional couplers, and six-port reflectometers. Various types of embedded RF power detectors are reviewed. The conventional approach and our approach for the RF power control circuits are compared. Also, embedded tunable active directional couplers are presented. Then, six-port reflectometers for embedded RF testing are introduced including a 77-GHz six-port reflectometer circuit in a 130 nm process. This circuit demonstrates successful calibrated reflection coefficient simulation results for 37 well distributed samples in a Smith chart. The details including the theory, calibration, circuit design techniques, and simulations of the 77-GHz six-port reflectometer are presented in this paper.

백내장 환자에서 비구면 다초점 인공수정체 삽입 후 시기능 평가 (Evaluation of Visual Performance for Implanted Aspheric Multifocal Intraocular Lens in the Cataract Patients)

  • 김재윤;이군자
    • 한국안광학회지
    • /
    • 제18권3호
    • /
    • pp.347-356
    • /
    • 2013
  • 목적: 비구면 다초점 인공수정체인 ReSTOR$^{(R)}$ SN6AD3 삽입안의 시력과 시기능 변화를 분석하였다. 방법: 양안 또는 단안에 비구면 다초점 인공수정체(ReSTOR$^{(R)}$ SN6AD3)를 삽입한 백내장 환자 19명의 30안을 대상으로 하였다. 수술 전, 수술 후 1주일, 1개월 및 3개월 후에 시력과 객관적인 시기능을 측정하였고 수술 3개월 후 인공수정체 삽입안의 시기능 측정값을 동일 연령대의 정상안 20명(38안)과 비교하였다. 원거리 시력은 2 m 거리에서 LCD chart ETDRS 시력표를 이용하여 측정하였고, 중간거리(50 cm)과 근거리(30 cm) 시력은 Jaeger chart를 이용하였다. 객관적인 시기능은 OQAS 장비를 이용하여 OSI (objective scatter index, 객관적 산란지수), MTF (modulation transfer function, 변조전달함수) cut off, Strehl ratio를 4 mm 동공크기에서 측정하여 수술 후 경과기간에 따른 측정값을 비교 평가하였다. 수술 3개월 째 시력 및 시기능은 객관적 평가와 주관적인 평가를 통해 동일 연령대의 정상안과 비교하였다. 결과: 나안 원거리 시력과 OSI, MTF와 Strehl ratio는 다초점 인공수정체 삽입 1개월까지 유의하게 향상되었다(p<0.05). 수술 3개월 후 다초점 인공수정체 삽입안의 MTF와 Strehl ratio는 정상 대조군의 수준으로 회복되었지만, OSI는 대조군보다 높은 값으로 측정되었다(p<0.001). 자각적인 원거리 및 근거리 시력에 대한 만족도는 높았지만, 중간거리 시력에 대한 만족도가 낮으며 눈부심과 빛 번짐 증상이 나타났다. 결론: 비구면 다초점 인공수정체 삽입안의 시기능은 수술 1개월 후부터 안정화되며 동일 연령대의 정상안의 수준으로 개선되지만 만족스러운 중간거리 시력을 제공하지 못하며 눈부심과 빛 번짐의 시각적 불편감이 나타나는 것으로 사료된다.