• 제목/요약/키워드: push-over 해석

검색결과 37건 처리시간 0.032초

전단강도 감소효과를 고려한 Pushover 해석 (Pushover Analysis Considering Effects of Degradation of Shear Strength)

  • 이영욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.514-517
    • /
    • 2006
  • Nonseismic designed RC frame have a possibility of shear failure because of deficiencies of reinforcing details. To model the shear failure in numerical analysis, shear strength degradation models which include Moehle's and ATC 40 are compared and applied to push-over analysis. For numerical analysis, three storied building frame is selected and designed according to Korean Concrete Design Code(2003). From the numerical analysis, it is pointed out that there may be great difference in lateral drift capacity if a different shear strength model is used. And the capacity can be severely underestimated if the restraining model of plastic rotation of ATC 40 is used, compared to the use of shear spring for shear degradation.

  • PDF

저층 철근콘크리트 건물의 간이 내진성능 평가법 제안 - Part 3. 내진성능 평가법의 타당성 검증 - (A Proposal of Rapid-Screening Method for Seismic Capacity Evaluation of Low-Rise R/C Buildings - Part 3. Verification of Applicability of Rapid-Screening Method -)

  • 이강석;김용인;위정두
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.467-468
    • /
    • 2009
  • 철근콘크리트 학교건물(Part 2의 대상건물)을 대상으로 일본내진진단법(2차 및 3차) 및 비선형 정적 및 동적해석을 실시하여 상세하게 대상건물의 내진성능을 평가한 결과와 본 연구에서 제안한 내진성능평가표를 이용하여 평가한 내진성능(Part-2)을 각각 비교 검토하여 본 연구의 간이 내진성능 평가법의 타당성을 검증하였다.

  • PDF

비선형 해석으로 평가한 전단벽의 이력거동 특성에 관한 연구 (Hysteretic Behavior Characteristics of R/C Shear Walls Evaluated by Nonlinear Analysis)

  • 김덕주;한상환;이리형
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 봄 학술발표회 논문집
    • /
    • pp.85-92
    • /
    • 1998
  • Most of tall apartment buildings constructed in our county are wall-type R/C structures composed of hear walls and slabs. It is necessary to evaluate of hysteretic properties of shear walls in wall-type R/C structures which resist lateral loads as well as axial loads. In this study, first to evaluate the wall's hysteretic behavior nonlinear analyses with IDARC 4.0 are performed for eight specimens subjected to horizontal load reversals. As a result of nonlinear analyses of specimens we can obtain three parameters which determined the hysteretic parameters such as stiffness degrading, strength deterioration and inching behavior respectively. With this three parameters, strength and deformation capacity of 5, 10, 20-story shear wall of apartment building is estimated from the results of push-over analysis.

  • PDF

비정형 Diagrid System의 내진성능 평가 (Seismic Performance Evaluation of Freeform Diagrid System)

  • 고창균;주영규;김상대
    • 한국강구조학회 논문집
    • /
    • 제23권2호
    • /
    • pp.189-198
    • /
    • 2011
  • 최근 건축물들이 미적인 아름다움을 추구하며 점차 비정형화 되어감에 따라 이를 실현시켜 주기 위한 새로운 구조시스템들이 개발되고 있다. Diagrid system은 외각에 배치 된 경사진 기둥을 통해 구조물의 중력하중과 횡력을 모두 저항하는 시스템으로 건물 내부에 기둥이 없어 비교적 평면 변화에 유리한 시스템이다. 하지만 현행의 내진설계 기준에는 이와 같은 새로운 구조시스템에 대한 내진성능계수가 명시되어 있지 않다. 이에 새로운 내진성능 평가 방법인 ATC-63이 제안되었다. 본 논문에서는 구조물의 비정형성을 고려해주기 위해 3D 비선형 해석 모델에 각각 작용하는 하중의 방향을 달리하며 ATC-63에서 제시하고 있는 절차에 따라 비정형 Diagrid system의 내진성능을 평가하였다.

강주탑의 비선형거동 특성을 고려한 케이블교량의 지진해석 (Evaluation of Seimic Capacity of Cable-Stayed Bridges Considering Inelastic Behavior of Steel Pylons)

  • 배성한;이경찬;장승필;김익현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.277-283
    • /
    • 2005
  • Inelastic model of Second Jindo Bridge is investigated to perform nonlinear dynamic analyses with various earthquake ground motions. The modal analysis is performed to obtain dynamic characteristics of the bridge and verify the model. It proves that the model has an appropriate dynamic characteristic and its natural frequency is relatively low. Four ground motions are chosen for time history dynamic analyses; El Centro, Kobe, Taft, and Mexico earthquake. Each ground motion multiplied by specified factors to investigate damages of the structure. The analyses prove that responses of the bridge depend on the duration time and the frequency characteristics of ground motion, not only peak acceleration. Static push-over analysis of steel pylon shows that the dynamic analysis over-estimates the seismic behavior of steel pylon definitely. Nonlinear spring hinge model is suggest to improve the shortage of the inelastic model could not deliberate local buckling damage. According to the time history analysis of nonlinear spring hinge model, it is proved that the inelastic beam element analysis overestimate the seismic capacity of steel pylon unquestionably with a large amount of errors.

  • PDF

동력분산형 고속철도의 주행성능 해석기술 연구 (Dynamic behavior analysis of the high speed EMC(Electric Multiple Unit))

  • 윤지원;박태원;이문구;전갑진;박성문;김정범
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1160-1165
    • /
    • 2008
  • The development of a new railway vehicle is under progress through the Next Generation High-Speed Rail Development Project in Korea. Its aim is to develope fundamental technology of the vehicle that can run over 400km/h. The new distributed traction bogie system, 'HEMU'(High-speed Electric Multiple Unit), will be used and is different from previously developed high speed railway vehicles. Previous vehicles adopted push-pull type system, which means one traction-car drives rest of the vehicle. Due to the difference, investigation on dynamic behavior and its safety evaluation are necessary, as a part of verification of the design specification. In this paper, current progresses of researches are presented. And the High-Speed Railway vehicle system is evaluated for a dynamic characteristic simulation. Proper models including air-suspension system, wheel-rail, bogie and car-body will be developed according to the vehicle simulation scenario. International safety standard will be applied for final verification of the system. This research can propose a better solution when test running shows a problem in the parts and elements. Finally, the vehicle that has excellent performance will be developed, promoting academic achievement and technical development.

  • PDF

휨강도와 전단강도의 확률분포를 고려한 연결보의 성능기반설계 (Performance Based Design of Coupling Beam Considering Probability Distribution of Flexural and Shear Strength)

  • 김윤곤;조석희
    • 콘크리트학회논문집
    • /
    • 제25권5호
    • /
    • pp.509-516
    • /
    • 2013
  • 이 연구에서는 휨힌지를 유도하기 위해 휨강도와 전단강도의 확률분포를 고려한 연결보의 성능기반설계법을 제안하였다. 이 방법은 연결보의 항복 이후 거동과 시스템의 재분배를 반영하므로 현행 선형해석 기반의 연결보 설계에서 임의로 저감된 유효강성의 적합성을 검증할 수 있으며, 사용하중에서의 연결보의 실제 강성을 반영하여 횡변위를 평가하는데 적정하다. 또한 부재간 내력 재분배를 고려할 수 있어 병렬전단벽의 최적설계가 가능할 것으로 판단된다. 이 설계법의 적합성을 검증하기 위해 단순화된 30층 오피스 건물을 대상으로 비선형정적해석을 수행하고 성능점 및 각 스텝의 구조성능을 검토하였다. 또한 사용하중의 부재강성을 평가하고 극한하중의 부재 강성을 사용한 시스템의 거동과 비교하였다. 또한 연결보의 다양한 배근 및 보 춤에 따른 시스템의 거동특성을 비교, 분석하였다.

학교 건축물의 내진 보강을 위한 가새 - 높이비에 관한 연구 (A Study on Brace-height Ratio for Seismic Retrofit of School Building)

  • 이화정;변대근;윤성기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권4호
    • /
    • pp.10-17
    • /
    • 2020
  • 최근 국내에 발생한 지진으로 인해 많은 학교 건물들에 크고 작은 피해가 발생하였다. 학교 건축물은 재난 발생시 대피소로 사용되는 중요 건물로서 비내진 건축물일 경우 여러 방법으로 내진 보강이 진행 중이다. 내진보강 공법 중 내부 철골가새골조형 공법은 비교적 시공이 용이하고 성능이 우수하여 많이 사용되고 있다. 본 연구에서는 기존 철근콘크리트 학교 건물에 철골 가새 골조를 적용하여 수평반복가력해석을 수행하여 최대전단력 및 변위를 비교검토 하였다. 그 결과로 해석 모델의 적정성을 확인하였고, 기존 학교 건축물의 1경간에 대한 가새- 높이비에 따른 효과를 비교 검토하였다. 가새- 높이비 0.3의 모델에서 최대 전단내력과 변위관계에서의 적정성을 확인할 수 있었다. 또한, 실제 비 내진 철근콘크리트 학교 건축물에 철골가새를 적용시켜 가새- 높이비에 따른 비선형정적해석을 수행하여 내진 성능을 검토하였다. 그 결과, 가새- 높이비 0.3에서 부재의 붕괴가 없는 적절한 내진효과를 보이고 있다. 가새 높이의 증가는 최대전단력과 인명안전 수준의 성능점에서 최대 하중을 증가시키는 효과를 나타내고 있으나, 횡강성의 증가로 인한 가새 골조 주변 부재의 붕괴가 발생하므로, 적정한 가새 높이에 따른 내진 보강이 필요하다는 것을 알 수 있었다. 따라서, 기존 학교건축물의 가새 골조의 내진보강 설계에 있어서 가새 높이에 따른 보강해석을 고려한 후 가새 높이를 선정하고 적절한 보강 개수와 보강위치를 정하는 것이 필요한 것으로 사료된다.

반응수정계수와 주기의 영향에 대한 철골모멘트저항골조 건물의 내진성능평가 (Seismic Evaluation of Steel Moment Frame Buildings based on Different Response Modification Factors and Fundamental Periods)

  • 신지욱;이기학;이도형
    • 한국지진공학회논문집
    • /
    • 제12권5호
    • /
    • pp.47-56
    • /
    • 2008
  • 본 연구는 높은 지진의 위험이 내재된 지역에 위치한 3층, 9층 그리고 20층 철골 모멘트저항골조에 대한 반응수정계수와 주기의 영향을 평가하기 위한 것이다. 각 구조물들은 IBC 2000과 KBC 2005에서 제시하고 있는 8의 반응수정계수로 설계되었고 건물에 기대되는 최소의 성능과 최대의 성능을 평가하기 위해서 상한범위와 하한범위의 설계가 고려되었다. 또한 반응수정계수에 대한 영향을 조사하기 위하여 4개의 다른 반응수정계수들이(9, 10, 11, 12) 각 구조물에 대하여 적용되었고 각 구조물의 고유주기 값 외의 4개의 다른 주기를 추가로 적용하여 구조물의 동적거동시 주기에 대한 영향을 조사하였다. 총 150개의 해석모델들은 50년 동안 2%의 초과확률(재현 주기 2500년)을 가진 20개의 지반운동에 대하여 평가되었다. 구조물의 성능평가를 위하여 정적 Pushover와 비선형 시간이력해석이 수행되었으며 구조물의 연성능력을 평가하기 위해서 변위연성요구가 고려되었다. 3층과 9층 구조물은 변위연성요구 값이 비교적 안정적인 거동을 보인 반면 20층 구조물은 동적 불안정성을 야기하는 요소에 의해 민감하게 나타나는 것으로 조사되었다.

재분배 기법 적용에 따른 철근 콘크리트 전단벽-골조 시스템의 비선형 특성 평가 (Evaluation of Inelastic Performance of a Reinforced Concrete Shear Wall-Frame System Designed by Resizing Algorithms)

  • 안진우;최세운;박효선
    • 한국전산구조공학회논문집
    • /
    • 제24권5호
    • /
    • pp.473-480
    • /
    • 2011
  • 반복적인 구조해석의 실행없이 부재 변위 기여도를 이용하여 부재 사이즈를 조절함으로써 건물의 변위를 만족시키는 재분배 기법은 실용적인 변위 설계법으로 인식되고 있다. 기존 연구에서 재분배 기법은 풍하중, 지진하중과 같은 횡하중을 받는 건물의 횡변위를 탄성범위 내에서는 효과적으로 제어할 수 있었으나, 재분배 기법에 따른 비탄성 성능 변화에 대한 연구는 미흡하였다. 본 연구에서는 재분배 기법에 의해 재설계된 구조물의 비탄성 성능변화를 확인하기 위해 7층 철근 콘크리트 전단벽-골조 시스템 예제에 재분배 기법을 적용하였다. 재분배 적용결과, 전단벽-골조 시스템의 상호작용 특성때문에 하층부에서는 전단벽의 물량이 증가하고 상층부에서는 골조의 물량이 증가하였다. 이러한 물량 재분배를 통해 초기 강성은 증가하였으며 연성 성능은 비슷한 수준으로 나타났다.