Browse > Article
http://dx.doi.org/10.11112/jksmi.2020.24.4.10

A Study on Brace-height Ratio for Seismic Retrofit of School Building  

Lee, Hwa-Jung (동인구조진단(주))
Byon, Dae-Kun (동인구조진단(주))
Yoon, Sung-Kee (부산대학교 건축공학과)
Publication Information
Journal of the Korea institute for structural maintenance and inspection / v.24, no.4, 2020 , pp. 10-17 More about this Journal
Abstract
The recent earthquake in Korea caused large and small damages to many school building. School building is an important building that is used as a shelter in the event of disaster. Among the seismic retrofit methods, the internal steel braced frame type method is used for its relatively easy construction and excellent performance. In this study, the maximum shear force and displacement were compared and examined by applying the brace frame to existing concrete school buildings. As a result, we verified the adequacy of the analytical model and compared and examined the effect of brace-height ratio on the span of the existing school buildings. The adequacy of the maximum shear force and displacement relationship can be confirmed in the model with a length of 0.3. In addition, seismic frame was applied to the actual non-seismic reinforced concrete school building, and the seismic performance was evaluated by nonlinear static analysis(Push-over analysis) according to the ratio of brace-height. As a result, the increase of the brace-height according to the brace-height ratio has the effect of increasing the maximum shear force and maximum load at the performance point. But the collapse of the braced frame due to the increase in the lateral stiffness occurred, indicating that seismic retrofit according to the proper brace-height is necessary. Therefore, in the seismic retrofit design of brace frame of existing school building, it is necessary to select the proper brace-height after retrofit analysis according to the brace-height ratio.
Keywords
school building; seismic performance; steel brace frame; brace-height ratio; nonlinear static analysis; seismic retrofit;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 A rchitectural Institute df Korea(AIK,2018) Site Inspection and Damage Investigation of Buildings by Earthquakes in Gyoungju and Pohang, 1-347.
2 C ANNY(2012), Three-Dimensional Nonlinear Static and Dynamic Structural Analysis Computer Program, Canada.
3 Japan Building Disaster Prevention Association(JBDPA, 2017)
4 Jung,H.C., Jung.J.S., Lee, K. S.,(2019), Seismic Performance Evaluation of Internal Steel Frame Connection Method for Seismic Strengthening by Cycling Load Test Nonlinear Analysis, Journal of the Korea Concrete Institute, 31(1), 79-88   DOI
5 Jung.J.S., Lee, K. S.,(2018), Seismic Performance Evaluation of Internal Steel Frame Connection Method for Seismic Strengthening by Cycling Load Test Nonlinear Analysis, Journal of the Korea Institute for Structural Maintenance and Inspection, 22(1), 137-146   DOI
6 Lee, K.S., Wi, J.D.,Kim, Y.I., Lee, H.H.,(2009), Seismic Safety Evaluation of Korean R/C School Building Built in the 1980s, Journal of the Korea Institute for Structural Maintenance and Inspection, 19(1), 013-022
7 MIDAS-2020 Program, MIDAS Information Technology Co., LTD.
8 A. S. Elnashai, R. Pinho, "Repair and Retrofitting of RC Walls using Selective Techniques", Journal of Earthquake Engineering, vol. 2, No. 4, 1998.
9 Choi, Kwang yong, "Seismic Retrofit Design Process of RC Structures using Dual Frame-type Vibration Control System", 10. The Ministry of Education (MOE and EDUFA, 2016), Quick Report of School Buildings damaged by 2016 Gyoungju District, 1-50.
10 Seismic Capacity Evaluation and Retrofit (Ministry of Education 2019)
11 Kim,M.S., Choi, H.S., Song, S.E., Lee, Y. H.,(2013), Seismic Capacity of Reinforced Concrete Frame Retrofitted with H-beam Frame, Journal of the Earthquake Engineering Society of Korea, 17(3), 127-132   DOI