• 제목/요약/키워드: pumping quantity

검색결과 35건 처리시간 0.022초

Transition Analysis of Friction Factor According to Pumping Pressure in Pumping Test Using High Strength Concrete for High-rise Buildings

  • Kwon, Hae-Won;Kim, Young-Su
    • 한국건축시공학회지
    • /
    • 제13권4호
    • /
    • pp.400-406
    • /
    • 2013
  • In high-rise buildings, high-strength concrete is widely used to reduce the section of structure members under axial load. Also, the price increase of materials is very important item in the high-rise buildings. Especially, concrete used high-pressure pump due to consecutive structural assembly. Unlike slump type of ordinary concrete, high strength concrete has different properties of concrete pumping due to viscosity. However, there have been no Korean studies on the pumping properties of high strength concrete. Therefore, this paper measures the friction factor of high strength concrete with changes in the pressure of concrete pumping. We analyzed the trends of the friction factor based on changes in the pressure of concrete pumping, and then calculated the quantity of concrete deposited for each specified concrete strength and location of placement. After comparing these results with the quantity of concrete deposited measured in field, we evaluated the pumping properties of high strength concrete. Through the tests and the review, we attempt to suggest some basic information for the In-Situ application of high strength concrete.

강변여과수 취수에 따른 지하수위의 계절적인 변동 특성

  • 정재열;함세영;이정환;김형수;류상훈;김태원;김문수
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2006년도 총회 및 춘계학술발표회
    • /
    • pp.68-71
    • /
    • 2006
  • Seasonal fluctuation of groundwater level by pumping amount and stream discharge at the riverbank filtrate site adjacent to the Nakdong River in Daesan-Myeon was characterized. Groundwater level fluctuation shows increase in wet season (June, July, August and September) and decrease in dry season (the other months). Seasonal variation of pumping amount shows similar trend to the groundwater fluctuation due to higher consumption of potable water in summer. The relation of specific capacity, Nakdong River and pumping quantity was analyzed. The logarithmic relationship between specific capacity and the stream discharge gives high correlation coefficient, 0.96. This fact indicates that the increase of stream discharge rate reduces the rate of drawdown in the pumping area in wet season.

  • PDF

온양온천지구에서의 온천수 수량평가 (Quantity Evaluation of Hot Spring at Onyang Spa Area)

  • 이철우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.438-441
    • /
    • 2006
  • The groundwater level was originally above the surface at the Onyang spa area. However, it is now 98-138m depth below the surface deu to the artificial pumping from boreholes. The fluctuations of the piezometric head were observed in 4 boreholes. Transmissivity estimated from the pumping rate and the drawdown is about $577.51 m^2/day$ The transmissivity of Onyang spa area is much larger than common values of fractured aqui for the drawdown of the piezometric head by artificial pumping is widely spreaded out in that area. The drawdown related to each pumping rate was analyzed and the formula between drawdown and pumping rate was made by a regression analysis. The formula can be applied for the condition of enough groundwater flowing into the Onyang spa area

  • PDF

경량골재를 사용한 경량콘크리트의 펌프압송 성능향상에 관한 실험적 연구 (The Experimental Study on improvement the pump sending of the light weight concrete using the light weight aggregate)

  • 박대오;서치호;지석원;이진우;신상태;지석원
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 춘계학술논문 발표대회 제6권1호
    • /
    • pp.23-26
    • /
    • 2006
  • The study about the concrete to use recently a light weight aggregate, processed actively. And concrete pumping with a high pressure pump has been popularized, the mechanical development, such as high pressure pumps or pipes, is progressing rapidly. Concrete placing by pumping has the advantage of the reduction of the construction period with workability, easiness of work and the increase of placing, but the quality variation of concrete is caused by pumping is seldom considered, including the increase of the pipe length by high-rising and large-sizing, there by the loss of the unit quantity of water, with pumpability or workability deteriorated. In this research, we will compare and analyze before pumping and after pumping samples of ready-mixed light weight concrete. The result of study as follow. The case of a light weight concrete which the low slump is more decrement compared with high slump light weight concrete in after pumping samples. After pumping the water by pressure of a pump was absorbed to the aggregate inside, and it showed an increase of compression strength about $5{\sim}20%$.

  • PDF

Ion Pump Design for Improved Pumping Speed at Low Pressure

  • Paolini, Chiara;Audi, Mauro;Denning, Mark
    • Applied Science and Convergence Technology
    • /
    • 제25권6호
    • /
    • pp.108-115
    • /
    • 2016
  • Even if ion pumps are widely and mostly used in ultra-high vacuum (UHV) conditions, virtually every existing ion pump has its maximum pumping speed around 1E-6 mbar (1E-4 Pa). Discharge intensity in the ion pump Penning cell is defined as the current divided by pressure (I/P). This quantity reflects the rate of cathode bombardment by ions, which underlies all of the various pumping mechanisms that occur in ion pumps (chemisorption on sputtered material, ion burial, etc.), and therefore is an indication of pumping speed. A study has been performed to evaluate the influence of magnetic fields and cell dimensions on the ion pump discharge intensity and consequently on the pumping speed at different pressures. As a result, a combination of parameters has been developed in order to design and build an ion pump with the pumping speed peak shifted towards lower pressures. Experimental results with several different test set-ups are presented and a prototype of a new 200 l/s ion pump with the maximum pumping speed in the 1E-8 mbar (1E-6 Pa) is described. A model of the system has also been developed to provide a framework for understanding the experimental observations.

태양광발전을 이용한 독립형 지하수 양수 시스템 개발 (Development of Stand-Alone Underground Water Pumping System using Photovoltaics System)

  • 이승훈;황정훈;조운식;김만일;이준기;박문희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2009
  • In this paper, the Stand-alone underground water pumping system was developed that is consist of Submersible Pump (AC type), Photovoltaic Array and Power converter by the application of solar energy. And also wish to introduce system that is possible to supply of drinking water or water for agriculture using solar energy at desertification area or a Off-grid area, interior etc. and operation test results. This system can use in deep tube well of 200m range with common Submersible Pump and maximized to the quantity of pumping through M.P.P.T control. Also system availability raised through apply various driving mode.

  • PDF

Estimating Groundwater Level Change Associated with River Stage and Pumping using Time Series Analyses at a Riverbank Filtration Site in Korea

  • Cheong, Jae-Yeol;Hamm, Se-Yeong;Kim, Hyoung-Soo;Lee, Soo-Hyoung;Park, Heung-Jai
    • 한국환경과학회지
    • /
    • 제26권10호
    • /
    • pp.1135-1146
    • /
    • 2017
  • At riverbank filtration sites, groundwater levels of alluvial aquifers near rivers are sensitive to variation in river discharge and pumping quantities. In this study, the groundwater level fluctuation, pumping quantity, and streamflow rate at the site of a riverbank filtration plant, which produces drinking water, in the lower Nakdong River basin, South Korea were interrelated. The relationship between drawdown ratio and river discharge was very strong with a correlation coefficient of 0.96, showing a greater drawdown ratio in the wet season than in the dry season. Autocorrelation and cross-correlation were carried out to characterize groundwater level fluctuation. Autoregressive model analysis of groundwater water level fluctuation led to efficient estimation and prediction of pumping for riverbank filtration in relation to river discharge rates, using simple inputs of river discharge and pumping data, without the need for numerical models that require data regarding several aquifer properties and hydrologic parameters.

제왕절개술 초산모의 자가 착유 행위 효과 (Effects of Self-breast Pumping in Primiparous Women after Cesarean Delivery)

  • 여정희;문길남;이선옥
    • 여성건강간호학회지
    • /
    • 제18권2호
    • /
    • pp.98-107
    • /
    • 2012
  • Purpose: This study was done to identify the effects of self-breast pumping on breastfeeding rates and, the degree of breast milk fullness among primiparous women giving birth by cesarean section. Methods: The study design was a non-synchronized posttest control group experiment with repeated measures. The participants were 60 women, 31 in the experimental group who used a manual pump 5 times a day after exclusive breastfeeding and 29 in the control group who breastfed exclusively with no other interventions. Results: While self-breast pumping did not improve breastfeeding rates or the degree of breast milk fullness at any of the time points studied, breastfeeding rates continued to remain high till 12 weeks postpartum in both groups. Conclusion: Although some modifications in research methods will be required to identify the effects of breast pumping and exclusive breastfeeding, both these approaches can be used as interventions to improve breastfeeding rates and breast milk quantity.

반도체 생산공정을 위한 고점도 감광성 폴리이미드 탈포 및 공급시스템에 관한 연구 (A Study on the High Viscosity Photosensitive Polyimide Degassing and Pumping System)

  • 박형근
    • 한국산학기술학회논문지
    • /
    • 제16권2호
    • /
    • pp.1364-1369
    • /
    • 2015
  • 반도체 칩의 고집적화로 과거 와이어 본딩 공정에서 BUMP 공정으로 전환되면서 반도체칩과 외부 기기로 이어지는 통신선도 더욱 미세해짐으로 인해 보다 정밀한 작업이 필요한 실정이지만 PSPI의 고점도 특성상 정량제어가 어렵고 버블유입에 따른 수율의 저하가 계속되고 있는 실정이다. 따라서 본 논문에서는 반도체 BUMP 공정에서 고점도 감광성 폴리이미드(PSPI : Photosensitive Polyimide)의 도포(coating)시 발생하는 기포(gas)를 제거하여 공급하는 D&P(Degassing and Pumping) 시스템을 개발하였다.

태양열을 동력원으로 한 물펌프 연구개발 - 에너지변환실험과 성능해석 - (Development of Solar Powered Water Pump - Energy conversion test and performance analysis -)

  • 김영복;이양근;이승규;김성태;나우정;정병섭
    • Journal of Biosystems Engineering
    • /
    • 제27권4호
    • /
    • pp.327-334
    • /
    • 2002
  • In this study, energy conversion from thermal energy to mechanical power by using n-pentane was tested and exergy variation, cycle number, water quantity pumped and thermal efficiency were analyzed. The energy conversion was done and the water head could be ten meters on the experimental conditions. The operating temperature range of cycle was recommended to be around the liquid-vapour saturation temperature of the working fluid on the viewpoint of the maximum work. The cycle diagram was analyzed by the exergy analysis. For the constant water head, the cycle number was decreased and the water quantity per day was increased and thermal efficiency become higher when the water quantity per cycle become increasing. For the constant pumping water quantity per cycle, cycle number and the water quantity per day was decreased and the thermal efficiency become higher because the saturation temperature become higher when the water head become higher.