• 제목/요약/키워드: pumping process

검색결과 201건 처리시간 0.03초

Determination of the Optimal Strategy for Pump-And-Treat Method

  • Ko, Nak-Youl;Lee, Kang-Kun
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 추계학술발표회
    • /
    • pp.204-207
    • /
    • 2001
  • An optimization process for the design of groundwater remediation is developed by simultaneously considering the well location and the pumping rate. This process uses two independent models: simulation and optimization model. Groundwater flow and contaminant transport are simulated with MODFLOW and MT3D in simulation model. In optimization model, the location and pumping rate of each well are determined and evaluated by the genetic algorithm. In a homogeneous and symmetric domain, the developed model is tested using sequential pairs for pumping rate of each well, and the model gives more improved result than the model using sequential pairs. In application cases, the suggested optimal design shows that the main location of wells is on the centerline of contaminate distribution. The resulting optimal design also shows that the well with maximum pumping rate is replaced with the further one from the contaminant source along flow direction and that the optimal pumping rate declines when more cleanup time is given. But the optimal pumping rate is not linearly proportional to the cleanup time and the minimum total pumping volume does not coincide with the optimal pumping rate.

  • PDF

유전자 알고리즘을 이용한 타이어 공력소음의 저감 (Reduction of Air-pumping Noise based on a Genetic Algorithm)

  • 김의열;황성욱;김병현;이상권
    • 한국소음진동공학회논문집
    • /
    • 제22권1호
    • /
    • pp.61-73
    • /
    • 2012
  • The paper presents the novel approach to solve some problems occurred in application of the genetic algorithm to the determination of the optimal tire pattern sequence in order to reduce the tire air-pumping noise which is generated by the repeated compression and expansion of the air cavity between tire pattern and road surface. The genetic algorithm has been used to find the optimal tire pattern sequence having a low level of tire air-pumping noise using the image based air-pumping model. In the genetic algorithm used in the previous researches, there are some problems in the encoding structure and the selection of objective function. The paper proposed single encoding element with five integers, divergent objective function based on evolutionary process and the optimal evolutionary rate based on Shannon entropy to solve the problems. The results of the proposed genetic algorithm with evolutionary process are compared with those of the randomized algorithm without evolutionary process on the two-dimensional normal distribution. It is confirmed that the genetic algorithm is more effective to reduce the peak value of the predicted tire air-pumping noise and the consistency and cohesion of the obtained simulation results are also improved in terms of probability.

Charge Pumping Measurements Optimized in Nonvolatile Polysilicon Thin-film Transistor Memory

  • 이동명;안호명;서유정;김희동;송민영;조원주;김태근
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.331-331
    • /
    • 2012
  • With the NAND Flash scaling down, it becomes more and more difficult to follow Moore's law to continue the scaling due to physical limitations. Recently, three-dimensional (3D) flash memories have introduced as an ideal solution for ultra-high-density data storage. In 3D flash memory, as the process reason, we need to use poly-Si TFTs instead of conventional transistors. So, after combining charge trap flash (CTF) structure and poly-Si TFTs, the emerging device SONOS-TFTs has also suffered from some reliability problem such as hot carrier degradation, charge-trapping-induced parasitic capacitance and resistance which both create interface traps. Charge pumping method is a useful tool to investigate the degradation phenomenon related to interface trap creation. However, the curves for charge pumping current in SONOS TFTs were far from ideal, which previously due to the fabrication process or some unknown traps. It needs an optimization and the important geometrical effect should be eliminated. In spite of its importance, it is still not deeply studied. In our work, base-level sweep model was applied in SONOS TFTs, and the nonideal charge pumping current was optimized by adjusting the gate pulse transition time. As a result, after the optimizing, an improved charge pumping current curve is obtained.

  • PDF

내부 승압 전원 발생기와 기판 인가 전원 발생기의 펌핑 수단을 공유한 전원 전압 발생기 (A Unified Voltage Generator Which Merges the Pumping Capacitor of Boosted Voltage Generator and Substrate Voltage Generator)

  • 신동학;장성진;전영현;이칠기
    • 대한전자공학회논문지SD
    • /
    • 제40권11호
    • /
    • pp.45-53
    • /
    • 2003
  • DRAM에서 사용되는 내부 승압 전원 전압과 기판인가 전원 전압 발생기를 공유함으로써 단일 Charge Pump에서 승압 전원과 기판 전원을 동시에 발생시키는 회로를 설계하였다. 이 회로는 0.14um의 DRAM 공정을 사용하여 기존 보다 전력 소모를 30%, 전체 면적을 40% 그리고 Pumping capacitor 면적을 29.6% 각각 감소하였으며 또한 전류 공급 효율을 13.2% 향상 시켰다. Charge Recycling 기법을 적용하여 Pumping capacitor의 Precharge 구간 동안 소모되는 전류를 75% 감소하였다.

물, 진공의 지배자 (Water - Commander of Vacuum)

  • 인상렬
    • 진공이야기
    • /
    • 제1권1호
    • /
    • pp.6-10
    • /
    • 2014
  • It is a common sense that water is an old offender crashing our dream of achieving a good vacuum in an early time. Various techniques for accelerating the removal of water have been developed and utilized. However, we generally are not skilled in treating the water pumping in a physically proper manner. We are rather used to handle the situation of the water pumping just like considering a conventional air pumping. Under such an erroneous approach, we cannot help making an overestimation on the pumping capability of our vacuum system, and it leads to a big mismatch between the real operation timing and the planned process schedule. In this article, some main points concerning with the subject that a vacuum pumping is really a water pumping will be discussed.

Experimental study on variation in rheological properties of concrete subjected to pressure and shearing by pumping

  • Jung Soo Lee ;Kyong Pil Jang ;Chan Kyu Park ;Seung Hee Kwon
    • Advances in concrete construction
    • /
    • 제16권1호
    • /
    • pp.59-68
    • /
    • 2023
  • In the pumping process, concrete moves along the pipe and experiences both pressure and shear. This changes the workability and flow characteristics of the concrete. However, the effect of pressure and shear on the change in properties of concrete during the pumping process has not yet been accurately identified. This study analyzed the effects of pressure and shear on the properties of concrete during pumping. For quantitative tests, lab-scale test equipment capable of simulating the pressure and shear applied to concrete during pumping was used. For one coarse aggregate type, two paste types, three mortar types, and five concrete types, the effects of pressure, shear, and shear under pressure conditions were examined by varying the maximum pressure (0 to 200 bar) and the rotational speed of the vane for shear (0 to 180 rpm). Under the maximum pressure condition of 200 bar, the water absorption of coarse aggregate increased by 0.62% and that of fine aggregate also increased. When the concrete was under pressure, significant changes (a reduction in a slump and an increase in viscosity and yield stress) compared with the effect of the elapsed time occurred owing to an increase in the water absorption of the aggregates. When both pressure and shear were applied to concrete, both the slump and viscosity decreased. As the rotational speed of the vane increased, changes in properties became significant. Shearing in the absence of pressure maintained the properties of concrete. However, shearing under pressure conditions caused a reduction in slump and viscosity.

소프트웨어 개발 방법론에 따른 양배수장 디지털 트윈 시스템 개발과정 고찰 (Exploration of Water Pumping Station Digital Twin System Development Process According to Software Development Methodologies)

  • 이병준;김난영;윤성수
    • 한국농공학회논문집
    • /
    • 제66권3호
    • /
    • pp.53-62
    • /
    • 2024
  • The purpose of this study is to examine the methodology for applying digital twin technology to pumping station, identify the factors to be determined at each stage, and present its applicability. When analyzing the requirements for developing a digital twin for pumping station, they were categorized into service requirements, IoT device requirements, and gateway requirements, with a total of 39 requirements established. In system design, it was structured according to the principles of modularity, abstraction, stepwise decomposition, and information hiding, allowing the implementation of planned items for diagnosis and operational management. There are difficulties in setting communication-related protocols and applying them in the field due to the complexity of overseeing the entire system with data. Therefore, it is necessary to clarify the purpose of the system, and there are challenges in identifying the characteristics of individual facilities, such as pumps in pumping station, and fully incorporating them into the system process. Thus, the framework of the initial design is crucial for implementing a digital twin.

반도체 생산공정을 위한 고점도 감광성 폴리이미드 탈포 및 공급시스템에 관한 연구 (A Study on the High Viscosity Photosensitive Polyimide Degassing and Pumping System)

  • 박형근
    • 한국산학기술학회논문지
    • /
    • 제16권2호
    • /
    • pp.1364-1369
    • /
    • 2015
  • 반도체 칩의 고집적화로 과거 와이어 본딩 공정에서 BUMP 공정으로 전환되면서 반도체칩과 외부 기기로 이어지는 통신선도 더욱 미세해짐으로 인해 보다 정밀한 작업이 필요한 실정이지만 PSPI의 고점도 특성상 정량제어가 어렵고 버블유입에 따른 수율의 저하가 계속되고 있는 실정이다. 따라서 본 논문에서는 반도체 BUMP 공정에서 고점도 감광성 폴리이미드(PSPI : Photosensitive Polyimide)의 도포(coating)시 발생하는 기포(gas)를 제거하여 공급하는 D&P(Degassing and Pumping) 시스템을 개발하였다.

온수 보일러용 열구동 펌프에 관한 연구 (A Study on the Thermal Pump of the Hot Water Boiler)

  • 염한길;김욱중;김창주
    • 연구논문집
    • /
    • 통권30호
    • /
    • pp.15-23
    • /
    • 2000
  • In this study, develop the thermal pump using water evaporation and condensation. Vapor from heating room moves up to pumping room and press the water of pumping room. Consequently water is pumped out to water tank. Then hot vapor direct contact with cold water in condensing room after pumping process. At this time, pressure of condensing room is down to-5kPa and suck in water of tank. This pump executes self ping and good durability because of no mechanical moving parts. Thermal pump is pumped cyclic so that, this pump is not used single. Therefore thermal pump of hot water boiler used to multi-stage for stable pumping rate. As the result of performance test, the developed thermal pump proves pumping action of water evaporation/condensation. And total volume flow rate is 500liter during one hour. If three thermal pump is installed parallel, this pump can use to the hot water boiler in the 300,000kcal/h class.

  • PDF

균일조도 동력경사관의 양해법 설계 (Explicit Design of Uniformly-Rough Pipe on a Slope with Pumping Power)

  • 유동훈;강찬수
    • 물과 미래
    • /
    • 제29권3호
    • /
    • pp.163-176
    • /
    • 1996
  • 균일조도관이 경사지어 설치되어 있을 때, 적정량의 유체를 유송하기 위하여 요구되는 펌프의 동력은 양해법으로 바로 산정할 수 있다. 그러나 펌프의 동력이 기지값으로 주어져 있고 관내 유출률이나 관경을 구하고자 할 때 기존 방법은 상당한 반복과정을 거쳐야 된다. 이러한 경우 유동훈(1995b)은 펌프가 작동치 않는 자연경사관이나 수평관에 펌프만 작동할 때의 균일조도관에 대하여 양해법 산정식을 개발한 바 있다. 본 연구는 그의 연구결과에 기초하여 균일조도 경사관에 펌프가 동시에 작동할 때 반복 시산과정을 거치지 않고 관내 유출률이나 관경을 양해법으로 바로 산정하는 수식을 개발하여 제시하였다. 양해법 산정식의 선택에 있어 관로흐름의 수리특성을 다섯가지로 구분하여 각 수리 특성구간의 경계조건식도 양해법으로 도출하였다. 또한 개발된 양해법 근사식을 간단한 설계예에 적용하여 계산의 효율성과 정확성을 확인하였다.

  • PDF