• Title/Summary/Keyword: pulse-like

Search Result 295, Processing Time 0.028 seconds

Design of Small-sized Earthquake Simulator using Servo-Motor (서보 모터를 이용한 지진 모사용 소형 진동대 설계)

  • 민경원
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.04a
    • /
    • pp.186-195
    • /
    • 1999
  • This study is focused on the design and performance test of an earthquake simulator using stepping motor. Stepping motor which controls the motion accurately with generated pulses is applied to the earthquake simulator. Earthquakes like El Centro and Taft are used as inputs to the earthquake simulator. First the number of pulses are calculated and sent to pulse generator, . Then the generator controls the simulator according to the pulse sings, It is shown that the measured signals from the simulator are in very good agreement with input signals of scale-downed earthquakes of El Centro and Taft. This simulator will be used for the experimental study of small-scaled building structures with tuned mass dampers under earthquakes.

  • PDF

Study on the high precision output of 50kV high-voltage inverter (50kV 고전압 인버터 고정밀 출력설계에 관한 연구)

  • Son, Y.G.;Suh, J.H.;Oh, J.S.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2199-2201
    • /
    • 2005
  • High voltage power supply with pulse load($4.5{\mu}s$ and PRF 60Hz) condition is investigated which is of interest for applications like Klystron modulator power supplies with output voltage of 50kV. The performance specifications with this type of power supplies are very stringent demanding tight regulation(<0.01%) and high efficiency(> 85%). The solution to this problem as a single stage converter is very difficult. The final output voltage is obtained as sum of the output of SCPS & PCPS. The combination of the two stages can satisfy the pulse load specifications. The analysis of the voltage and power division between SCPS & PCPS has been done for the proposed topology. It has studied under various operating conditions of line and load. Simulation results are validated by experimental results.

  • PDF

On the Analysis of Dynamic Characteristics of Pipe Supporting Hydraulic Snubber in Electric Power Plant with State-space Model and Impulse Testing (상태공간 모델과 임펄스 시험에 의한 발전소 배관지지용 유압완충기의 동특성 해석)

  • Lee, Jae-Cheon;Hwang, Tae-Yeong
    • 연구논문집
    • /
    • s.31
    • /
    • pp.89-99
    • /
    • 2001
  • This paper presents the modeling and analysis of dynamic characteristics of hydraulic snubber in electric power plant. The nonlinear state-space model of 14th order to describe the dynamics of the snubber was established by Simulink. The simulation results show that the hydraulic snubber reacts as like the conventional shock absolvers against the high pulse shock load. The snubber also shows the peculiar characteristics to the small step load, which temporarily lock the control valves up, however maintain same steady-state pressures of all internal chambers in the long run. Two case studies for the analysis of the snubber are addressed. Practical pulse testing method was also proposed to identify the frequency response of the snubber.

  • PDF

Nano Wear Behavior of a-C Films with Variation of Surface Roughness (표면거칠기의 변화에 따른 a-C 박막의 나노마멸 거동)

  • 채영훈;장영준;나종주;김석삼
    • Tribology and Lubricants
    • /
    • v.20 no.3
    • /
    • pp.125-131
    • /
    • 2004
  • Nano-wear behavior of amorphous carbon films was studied by Atomic Force Microscopy. The a-C films are deposited on Si(100) substrate by DC magnetron sputtering method. The influences of different surface roughness on the nano-wear are investigated. Nano-wear tests were carried out using a very sharp diamond coated tip. Its spring constant was 1.6 N/m and radius of curvature was 110 nm. Normal force used in the wear tests ranged 0 to 400 nN. It was found that surface depression occurred during scratching because of plastic deformation and abrasive wear (cutting St ploughing). Wear depth increased linearly with normal force. Changing the surface roughness variables according to the bias pulse control, the less surface roughness decreased the wear depth. The thickness did not affect the wear resistance.

Laser Induced Microjet Drug Delivery System: Drug Permeation Depending on Laser Wavelength and Pulse Duration (레이저 유도 마이크로젯을 활용한 약물 전달 방식: 레이저 파장 및 펄스길이에 따른 약물 침투 분석)

  • Jang, Hun jae;Ham, Hwi chan;Yoh, Jai ick
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.7
    • /
    • pp.463-468
    • /
    • 2017
  • For transdermal drug delivery, needless injection system is composed of laser and microjet injector. Main mechanism of microjet injector is the laser-induced bubble. Nd:YAG and Er:YAG laser are used as a power source. Laser parameters such as pulse duration and wavelength are considered, which are core parameters to control the bubble motion. The Nd:YAG laser, pulse duration is short than bubble life time making cavitation like bubble while in Er:YAG laser, long pulse duration and high absorption in water drive bubble as a boiling bubble. Detailed motion of bubble and microjet is captured by the high speed camera. So it is observed that microjet characteristics are determined by the bubble behavior. The performance of drug delivery system is evaluated by fluorescent staining of guinea pig skin.

Estimated Blood Pressure Algorithm of Wrist Wearable Pulsimeter Using by Hall Device (홀소자를 이용한 손목착용 맥진기의 혈압추정 알고리즘)

  • Ahn, Myung-Cheon;Cho, Jong-Gu;Son, Il-Ho;Lee, Sang-Suk;Kim, Kuen-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.3
    • /
    • pp.106-113
    • /
    • 2010
  • In order to get the precise blood pressure and pulse number in the cuffless status, the wrist wearable pulsimeter with a portable and small size apparatus using by Hall device is developed. The regression analysis of the pulse wave measured by the testing product of pulsimeter is conducted two equations of the blood pressure algorithm. The estimated values of blood pressure obtained by the cuffless pulsimeter during 5 s are compared with the practical values measured by electronic or mercury liquid blood pressure meters. The standard deviation of the estimated value and the practical value for the high blood pressure and the low blood pressure were 12.1 and 5.9, respectively, which have the neighborhood values of BP International Standard. The detail analysis of a pulse wave measured by cuffless wrist wearable detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of blood pressure applying for oriental medical apparatus like as the wrist wearable pulsimeter.

The Literatual study on 《GeumGueyoryak·Hakbyeongmaekjeungbyeongchi》 (《금궤요략·학병맥증병치제사》 편(篇)에 대한 문헌적(文獻的) 고찰(考察))

  • Kim, Un-gil;Park, Yang-chun
    • Journal of Haehwa Medicine
    • /
    • v.10 no.1
    • /
    • pp.133-148
    • /
    • 2001
  • From this book, $\ll$GeumGueyoryak Hakbyeongmaekjeungbyeongchi$\gg$, I finally got these conclusions of symptoms and pathology of Hakbyeong. 1. Hakbyeong has main symptoms of repetition of chillness and fever and its main pulse is pulse of Hyeon(弦) and position is in the middle of inside and outside. 2. Change in shape of pulse caused by Hakbyeong can have shape of pulse of Sak(數), Jee(遲), Kin(緊), Dae(大) and more kinds depending on patients constitution, the cause of disease, or whether he/she has been poisoned by other kinds. 3. After 15 days of symptoms, As Cheonki(天氣) and Inki(人氣) get stronger and Saki(邪氣) gets weaker, Jeongki(正氣) can be more recovered and the diseases can be disappeared. But if the disease dose not get away after another 15 days of showing symptom, that disease can be treated as cutting the Jingha under side of him/her. 4. The type of Hakbyeong which is diseased by the keeping the Haksa for long time, can be classified as Hagmo which has symptoms of chillness and fever outside, and of Jinggha inside, Danhag which has symptoms of difficulty with breathing, chest discomfort - caused by fever in the lung at ordinary times -, fever of extremities and nausea and that would make people worn out and thin after all, Onhag which has main symptoms of fever and Mohag which has symptoms of less fever and more chillness. 5. In this thesis it has been described, the Byulgabjunhwan(鼈甲煎丸), Baekhogagaejitang(白虎加桂枝湯), and Chokchilsan(蜀漆散) is the respective prescription for treatment of Hagmo, Onhag, and Mohag. From this conclusion, if the more research about the cause of disease, pathology and prescription of the each symptom from GeumGueyoryak hereafter, I could say more effective prophylaxis and treatment of epidemic disease like todays Hakbyeong can be found.

  • PDF

The oriental medical study about the arrythmia detected on the radial pulses and the result of ECG (촌관척(寸關尺)부의 검측한 부정맥과 electrocardiographic 결과와의 한의학적 검토)

  • Lyu, Heui-Yeong;Heo, Eun-Jung;Kim, Ji-Hyon;Yun, Jung-Mi;Jeon, Seong-Ha
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.14 no.1
    • /
    • pp.81-106
    • /
    • 2008
  • The ECG which used for this paper, is analysis result from alogrisms of arrythmia, and we have studied that how we could certain Cold(寒 )type or Heat(熱) type and that Deficiency(虛) type or Excess(實)type of organs from various special diseases, and we obtained like these results. 1. we depend on our examination about Pulse(脈) because we can't discriminate arrythmia using EKG analysis instruments. 2. We obtained that Cold(寒) type diseases had wave that prolonged above normal baseline and ST wave which had downward aptitude. 3. We obtained that Heat(熱) type diseases had the fibrillation which had shortend wave that compare to normal and had downward aptitude or negative aptitude. 4. We obtained that Respiratory system (肺) diseases had wave that is within normal or is short of normal range and had much fluctuation in potential difference or trans on P wave. 5. The character of EKG which presented about diseases of gastric systems is prolonged above narmal range of wave, and the EKG had represented mixed wave with Heat(熱) type when accompany inflammatory in gastric system. 6. The wave of Blood Stasis(瘀血) type had upward aptitude of QRS wave, and the wave of anemia or blood loss type(少血 ) had downward aptitude of QRS wave, the wave which had both Cold(寒) and Heat (熱) represented mixed waves. 7. The Knotted Pulse(結脈) and Intermittent Pulse(代脈) is corresponded with sinus brady cardia, and the Swift Pulsle(疾脈) is corresponded with fibrillation. 8. We pay attention to the relations of formations about pressures pulse from formations of EMD( electromechanical dissociation ). From these results, we will have to study about EKG which using in tests of change of Parkinsons disease.

  • PDF

Study on Breathing and Pulsation, Chongu and Inyeong of Healthy Man (평인(平人)의 호흡맥동(呼吸脈動)과 촌구인영(寸口人迎)에 대한 연구)

  • Lee, Hye-Yeon;Kang, Jung-Soo
    • Journal of Korean Medical classics
    • /
    • v.22 no.4
    • /
    • pp.1-13
    • /
    • 2009
  • When feeling the pulse, healthy man' pulse is the criterion for diagnosis whether you are a sick person. Healthy man is defined as one who is harmonious and not sick in sympathy with natural order. Among the factors for being Healthy man, breathing and pulsation, Chon-gu(寸口) and Inyeong(人迎) are most closely connected with the representative methods of feeling the pulse which are used currently. According to "Hwangjenaegyeong(黃帝內經)" on breathing and pulsation, the pulse beats twice per a breathing-in and a breathing-out each. And for a specific breathing, it beats 5 times including the remnant with a big breath. That the pulse beats twice means that it beats not only twice, but also regularly and repeatedly. The remnant is related to the meaning on a leap month, 5-time beating during a breath is connected with the contents of Osipyeong(五十營). A human is not always in stable and sticks to balance continuously with changes under the circumstances. So when it comes to a criterion how to measure the pulsation frequency, breathing is much more reasonable than pulsation and breathing calculated for a minute. According to "Hwangjenaegyeong(黃帝內經)", Healthy man is the person of whose Chon-gu and Inyeong are in order and much the same in response to each other. Although there is a minor difference in the meaning of term between Chon-gu and Gigu(氣口), Maekgu(脈口) in originally, it is used as almost same meaning when Chon-gu is used in opposition to Inyeong. Afterwards, depending on medical men, around neck or Chon-gu of the left hand are measured for Inyeong. However, Inyeong described in "Naegyeong(內經)" is Jokyangmyeong(足陽明) and it means the Hyeol(穴) around neck where the pulse beats, it looks like about the carotid area. Chon-gu is fall under Eum(陰) and Inyeong(人迎) is fall under Yang(陽). Therefore Chon-gu is continuous with eumgyeong(陰經) and Inyeong is continuous with yanggyeong(陽經). In addition, the pulse and the four seasons meet each other and Inyeong is a little stronger in spring summer and Chongu is a little stronger in fall winter.

  • PDF

Induction motor Modeling and Converter circuit Simulation using Pspice (Pspice를 이용한 유도전동기 모델링과 전력변환회로 시뮬레이션)

  • 서영수;백동현;조문택;이상봉
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.148-151
    • /
    • 1997
  • Pspice is not offered a library of mechanical factor like DC Motor, Induction Motor which is needed in Power Electronics field. Therefore, Induction Motor was made library by Equibalent circuit in this study. This model is applied in Voltage-Type inverter and is investigated its characteristics. IGBT is tested by two methods of Macro and Micro Modeling as semiconductor. PWM signal is used of pulse signal. Voltage and current, speed was simulated for assurance of model.

  • PDF