Browse > Article
http://dx.doi.org/10.4283/JKMS.2010.20.3.106

Estimated Blood Pressure Algorithm of Wrist Wearable Pulsimeter Using by Hall Device  

Ahn, Myung-Cheon (Dtron Co., Ltd, Room #203, Oriental Medical Industry Development)
Cho, Jong-Gu (Dept. of Oriental-Western Biomedical Engineering, Sangji University)
Son, Il-Ho (Dept. of Oriental Biomedical Engineering, Sangji University)
Lee, Sang-Suk (Dept. of Oriental-Western Biomedical Engineering, Sangji University)
Kim, Kuen-Ho (Dept. of Computer and Information Communication, The Cyber University of Korea)
Abstract
In order to get the precise blood pressure and pulse number in the cuffless status, the wrist wearable pulsimeter with a portable and small size apparatus using by Hall device is developed. The regression analysis of the pulse wave measured by the testing product of pulsimeter is conducted two equations of the blood pressure algorithm. The estimated values of blood pressure obtained by the cuffless pulsimeter during 5 s are compared with the practical values measured by electronic or mercury liquid blood pressure meters. The standard deviation of the estimated value and the practical value for the high blood pressure and the low blood pressure were 12.1 and 5.9, respectively, which have the neighborhood values of BP International Standard. The detail analysis of a pulse wave measured by cuffless wrist wearable detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of blood pressure applying for oriental medical apparatus like as the wrist wearable pulsimeter.
Keywords
Hall device; cuffless pressure; wrist wearable pulsimeter; a pulse wave; estimated algorithm of blood pressure;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 M. C. P. Carrasquero, L. M. H. Bernard, H. Kobori, Y. Ozawa,K. S. H. Smith, L. L. Hamm, and L. G. Navar, Hypertension,44, 223 (2004).   DOI   ScienceOn
2 S. W. Kim, Y. G. Choi, H. S. Lee, D. H. Park, D. G. Hwang,S. S. Lee, G. W. Kim, S. G. Lee, and S. J. Lee, J. Appl. Phys.,99, R908 (2006).
3 S. D. Choi, S. W. Kim, G. W. Kim. M. C. Ahn, M. S. Kim,D. G. Hwang, and S. S. Lee, J. Magn. Magn. Mater., 310, e983(2007).   DOI   ScienceOn
4 S. S. Lee, D. G. Hwang, G. W. Kim, S. W. Kim, and H. H. Kim, The Korean Patent Registration Number; 0730385, 2007.
5 S. D. Choi, M. S. Kim, M. C. Ahn, Y. G. Choi, G. W. Kim, D. H. Park, D. G. Hwang, and S. S. Lee, J. Kor. Mag. Soc., 16, 216 (2006).   DOI   ScienceOn
6 S. A. Hope, P. Antonis, D. Adam, J. D. Cameron, and I. Meredith, J. Hypertension, 25, 2105 (2007)   DOI   ScienceOn
7 S. A. Hope, P. Antonis, D. Adam, J. D. Cameron, and I. Meredith, The Korean Patent Publication Number; 10-2001-28668, 10-2002-96224.
8 S. A. Hope, P. Antonis, D. Adam, J. D. Cameron, and I. Meredith, The Korean Patent Utility Registration Number; 20-0358195.
9 X. Niu, X. Z. Yang, C. Y. Fu, Zhongguo Zhong, Xi Yi Jie, andHe Za Zhi., 14, 435 (1994).
10 M. F. O'Rourke, R. P. Kelly, and A. P. Avolio, The Arterial Pulse, 1st Ed., Lea & Febiger, Philadelphia (1992).
11 E. M. Ka and D.-R. Son, J. Magnetics, 13, 34 (2008).   DOI   ScienceOn
12 N. T. Thanh, D. Y. Kim, and C. G. Kim, J. Magnetics, 12, 40(2007).   DOI   ScienceOn
13 M. S. Kim, S. W. Kim, G. W. Kim, S. J. Lee, S. G. Lee, H. S.Lee, D. H. Park, D. G. Hwang, and S. S. Lee, J. Kor. Mag. Soc., 15, 307 (2005).   DOI   ScienceOn
14 S. S. Lee, G. W. Kim, M. C. Ahn, Y. S. Park, J. G. Choi, S. D.Choi, D. H. Park, D. G. Hwang, and H. R. Yoon, J. Biomed. Eng. Res., 28, 721 (2007).
15 S. S. Lee, M. C. Ahn, and S. H. Ahn, J. Magnetics, 14, 132(2009).   DOI   ScienceOn
16 S. M. Sze, Physics of Semiconductor Devices, 2nd Ed., John Wiley & Sons, pp. 30-35 (1981).
17 Y. Z. Yoon, H. M. Johng, K. S. Shin, C. G. Jung, and K. S. Soh, SaeMulli, 40, 494 (2000).
18 Q. Yu, J. Zhou, and Y. C. Fung, Am. J. Physiol. Heart Circ. Physiol., 265, 52 (1993).
19 A. Lu, C. H. Cheng, Y. Y. Lin Wang, and W. K. Wang, Am. J. Chin. Med., 24, 315 (1996).   DOI   ScienceOn