• Title/Summary/Keyword: pulse number

Search Result 723, Processing Time 0.029 seconds

An Improved SPWM Strategy to Reduce Switching in Cascaded Multilevel Inverters

  • Dong, Xiucheng;Yu, Xiaomei;Yuan, Zhiwen;Xia, Yankun;Li, Yu
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.490-497
    • /
    • 2016
  • The analysis of the switch status of each unit module of a cascaded multi-level inverter reveals that the working condition of the switch of a chopper arm causes unnecessary switching under the conventional unipolar sinusoidal pulse width modulation (SPWM). With an increase in the number of cascaded multilevel inverters, the superposition of unnecessary switching gradually occurs. In this work, we propose an improved SPWM strategy to reduce switching in cascaded multilevel inverters. Specifically, we analyze the switch state of the switch tube of a chopper arm of an H-bridge unit. The redundant switch is then removed, thereby reducing the switching frequency. Unlike the conventional unipolar SPWM technique, the improved SPWM method greatly reduces switching without altering the output quality of inverters. The conventional unipolar SPWM technique and the proposed method are applied to a five-level inverter. Simulation results show the superiority of the proposed strategy. Finally, a prototype is built in the laboratory. Experimental results verify the correctness of the proposed modulation strategy.

Partial Discharge Detection for the Power Cables using AC and Oscillating wave Voltage (전력케이블에서 교류전압과 진동파 전압을 이용한 부분방전 측정)

  • Kim, Jeong-Tae;Kim, Nam-Jun;Lee, Jeon-Seon;Gu, Ja-Yun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.4
    • /
    • pp.247-252
    • /
    • 1999
  • In this paper, in order to investigate availability of the OW-PD measurement method which has been proposed as an alternative of AC-PD measurement method to an after laying test and/or diagnosis for the power cable system, partial discharges owing to the needle-type defect integrated into the cable have been measured using AC and OW(Oscillating Wave) voltages. In the AC-PD measurement, the magnitude, phase and pulse number of partial discharges have been changed with the duration of voltage application, which can be analyzed through the relation with the process of the electrical tree initiation and propagation. In addition, the characteristics of partial discharges using OW voltage are appeared to be similar to those in case of AC-PD measurement and to be different with the shapes of electrical tree. From these results, it is concluded that the OW-PD measurement method is available to the tests for the cable system.

  • PDF

Laser Micro-drilling of Sapphire/silicon Wafer using Nano-second Pulsed Laser (나노초 펄스 레이저 응용 사파이어/실리콘 웨이퍼 미세 드릴링)

  • Kim, Nam-Sung;Chung, Young-Dae;Seong, Chun-Yah
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.2
    • /
    • pp.13-19
    • /
    • 2010
  • Due to the rapid spread of mobile handheld devices, industrial demands for micro-scale holes with a diameter of even smaller than $10{\mu}m$ in sapphire/silicon wafers have been increasing. Holes in sapphire wafers are for heat dissipation from LEDs; and those in silicon wafers for interlayer communication in three-dimensional integrated circuit (IC). We have developed a sapphire wafer driller equipped with a 532nm laser in which a cooling chuck is employed to minimize local heat accumulation in wafer. Through the optimization of process parameters (pulse energy, repetition rate, number of pulses), quality holes with a diameter of $30{\mu}m$ and a depth of $100{\mu}m$ can be drilled at a rate of 30holes/sec. We also have developed a silicon wafer driller equipped with a 355nm laser. It is able to drill quality through-holes of $15{\mu}m$ in diameter and $150{\mu}m$ in depth at a rate of 100holes/sec.

Scanning Stereoscopic PIV for 3D Vorticity Measurement

  • SAKAKIBARA Jun;HORI Toshio
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.1-13
    • /
    • 2004
  • A scanning stereo-PIV system was developed to measure the three-dimensional distribution of three-component velocity in a turbulent round jet. A laser light beam produced by a high repetition rate YLF pulse laser was expanded vertically by a cylindrical lens to form a laser light sheet. The light sheet is scanned in a direction normal to the sheet by a flat mirror mounted on an optical scanner, which is controlled by a programmable scanner controller. Two high-speed mega-pixel resolution C-MOS cameras captured the particle images illuminated by the light sheet, and stereoscopic PIV method was adopted to acquire the 3D-3C-velocity distribution of turbulent round jet in an octagonal tank filled with water. The jet Reynolds number was set at Re=1000 and the streamwise location of the measurement was fixed at approximately x = 40D. Time evolution of three-dimensional vortical structure, which is identified by vorticity, is visualized. It revealed that the existence of a group of hairpin-like vortex structures was quite evident around the rim of the shear layer of the jet. Turbulence statistics shows good agreement with the previous data, and divergence of a filtered (unfiltered) velocity vector field was $7\%\;(22\%)$ of root-me an-squared vorticity value.

  • PDF

Ablation rate study using short pulsed laser subjected to Alumina medium (알루미나 세라믹 소재의 초단파 레이저 어블레이션량 연구)

  • Kim, Kyunghan;Park, Jinho
    • Laser Solutions
    • /
    • v.18 no.4
    • /
    • pp.17-22
    • /
    • 2015
  • In this paper, ablation rate of $Al_2O_3$ ceramics by femtosecond laser fluence is derived with experimental method. The automatic three axis linear stage makes laser optics to move with high spatial resolution. With 10 times objective lens, minimal pattern width of $Al_2O_3$ is measured in the focal plane. Ablated surface area is shown as linear tendency increasing number of machining times with various laser power conditions. Machining times is most sensitive condition to control $Al_2O_3$ pattern width. Also, the linear increment of pattern width with laser power change is investigated. In high machining speed, the ablation volume rate is more linear with fluence because pulse overlap is minimized in this condition. Thermal effect to surrounding medium can be minimized and clean laser process without melting zone is possible in high machining speed. Ablation volume rate decelerates as increasing machining times and multiple machining times should be considered to achieve proper ablation width and depth.

A Data Acquisition System based upon a Single-board Microcomputer (단일보드 마이크로 컴퓨터를 이용한 자료(資料) 수집장치(蒐集裝置))

  • Choi, C.H.
    • Journal of Biosystems Engineering
    • /
    • v.14 no.4
    • /
    • pp.221-228
    • /
    • 1989
  • A data acquisition system was designed to measure the forces on a rolling coulter in three coordinated directions, angular velocity of the coulter and travel speed of a soil bin. The data acquisition system consisted of a dynamometer, speed transducers, a signal conditioner, an inter-face board, an Aim-65 microcomputer and a digital data recorder. Strain gages were attached on the surface of the dynamometer and connected to form three Wheatstone bridges, which measure the draft force, the vertical force and the side force on the coulter. An interaction among three dimensional forces was found during the calibration. A matrix procedure was used to correct the forces for this interaction. Rotary shaft encoders were mounted on the coulter and on the soil bin drive to measure the angular velocity of the coulter and the travel speed of the soil bin. The angular velocity and the travel speed were computed by counting the number of pulse signals from the rotary shaft encoders every 0.2 second. The digital signals from the rotary shaft encoders were connected to counters and the analog signals from the dynamometer, after passing through the signal conditioner, were connected to the A/D converter. The microcomputer programs, written in assembly language, were developed to read signals from the transducers, convert them to actual unit, display them upon request and record them on a sigital tape every 0.2 second.

  • PDF

Optimization of panel parameters and drive signals for high-speed matrix addressing of a bistable twisted-nematic LCD (쌍안정 TN LCD의 고속 매트릭스 어드레싱을 위한 패널 파라미터와 구동 파형의 최적화)

  • 이기동;박구현;장기철;윤태훈;김재창;이응상
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.6
    • /
    • pp.417-422
    • /
    • 1998
  • In this paper we introduce a method to optimize panel parameters and drive signals in a matrix-adressed bistable twsited-nematic (BTN) liquid crystal display (LCD) panel. We measured the effect of data pulses on optical switching characteristics in a BTN LC cell to model the effect theoretically. We introduce a weighting function to model the effect of data pulses on the switching energy as a function of time. Once the weighting function is known, we can estimate the maximum number of lines for multiplexing operation at a given frame rate by calculating the minimum data pulse width. By characterizing a unit cell as we change panel parameters (for example, d/p ratio), we can optimize parameters for high-speed operation. We found that our theoretical predictions agree very well with experimental results.

  • PDF

Suppression of Stimulated Brillouin Scattering in Optical Fiber using Sampled-Fiber Brags Grating (샘플링 광섬유 Bragg 격자를 이용한 광섬유 내의 유도 Brillouin 산란 억제)

  • Lee, Ho-Joon
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.485-489
    • /
    • 2005
  • I have investigated a scheme for suppressing stimulated Brillouin scattering in optical fibers. The scheme makes use of a sampled Bragg grating fabricated within the fiber used for transmitting intense Q-switched pulses. The grating is designed such that the spectrum of the Stokes pulse generated through stimulated Brillouin scattering falls entirely within its stop band. I show numerically that the number of sampled fiber Bragg gratings in 1 m is applied directly to suppressing stimulated Brillouin scattering rather than the coupling coefficient. This prevents the build up of the backward-propagating Stokes wave and mitigates the deleterious effects of stimulated Brillouin scattering. The simulation shows that 15 ns pulses with 1 kW peak power can be transmitted though a 1 m-long fiber with little energy loss using this scheme.

Discharge characteristics of Flat Fluorescent Lamp (FFL(Flat Fluorescent Lamp)의 방전 특정)

  • Kwon, Soon-Seok;Ryu, Jang-Ryeol
    • 전자공학회논문지 IE
    • /
    • v.44 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • This experiment was analysed the discharge characteristics of FFL(flat fluorescent lamp). FFL is operated by sine and pulse wave source. We use FFL which has the electrodes covered with dielectric, observed the discharge characteristics of FFL by V-Q Lissajous' figure. When FFL is operated with pulsed, the discharge current flows after the applied voltage is risen. When the duty ratio increases, the number of metastable xenon atoms seem to increase. Consequently, the 172nm radiation becomes strong as the duty ratio increases.

The Effect of Meridian Massage on the Reduction of Pain and Subjective Symptoms of Myofascial Pain Syndrome (경락마사지가 근막동통 증후군의 동통과 자각증상 감소에 미치는 효과)

  • Sung, Kyung-Suk;Jung, Hyang-Mi
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.6 no.2
    • /
    • pp.248-256
    • /
    • 2003
  • Purpose: This research was for checking the effect of meridian massage on the reduction of pain and subjective symptoms of myofascial pain syndrome. Method: The method of the research was interruptive time series design. The research objects are 25 hospital workers with myofascial pain syndrome at B hospital in Busan from July 22, 2002 to August 18, 2002. SPSS Win 10.0 was used for data analysis, paired t-test and repeated measures ANOVA for hypothesis test. Result: The recipients of meridian massage felt less pain than before(F=12.587, p=.000). The recipients of meridian massage felt less often than before (F=6.705, p=.001). The recipients of meridian massage got lower score on subjective symptoms of myofascial pain than before(F=12.857, p=.000). The recipients of meridian massage had lower blood pressure than before(systolic blood pressure; t=4.697, p=.000, diastolic blood pressure; t=3.426, p=.002). The recipients of meridian massage did not get the lower number of pulse than before(t=0.33, p=.744). Conclusion: The above results show that meridian massage is effective on the reduction of pain and subjective symptoms of myofascial pain syndrome and makes stable the blood pressure. Therefore meridian massage can be apply as the effective intervention for the reduction of pain and subjective symptoms of myofascial pain syndrome.

  • PDF