• Title/Summary/Keyword: pulse number

Search Result 720, Processing Time 0.027 seconds

Growth inhibition of Saccharomyces cerevisiae by alternation current pulse (교류 펄스에 의한 Saccharomyces cerevisiae의 생장억제 효과)

  • 정지환;박현근;한홍의
    • Korean Journal of Microbiology
    • /
    • v.25 no.3
    • /
    • pp.249-253
    • /
    • 1987
  • Effects of Ac pulse at low voltage on Saccharomyces cerevisiae were studied. The treatment of yeast suspensions contained 0.2m NaCl with 500mA for 350 sec at $40^{\circ}C$ was shown about 50% of lethality, whereas in the treatment of the same suspensions with 250mA for 250 sec at the temperature ($10^{\circ}C$) corresponding to about 10% of lethality, growth was completely inhibited instead of lethality. The effect of growth inhibition was due to occurrence of auxotrophic strains under experimental conditions. Detection of auxotrophic yeasts was done tentatively with the difference of the number of viable yeast cells between direct counting by methylene blue staining and plate-count on yeast morphology agar.

  • PDF

Performance Analysis of Pulse Position Modulation-Time Hopping Ultra Wide Band Systems with Antenna Diversity in Indoor Wireless Channel (실내 무선채널에서 안테나 다이버시티를 적용한 펄스위치변조-시간도약 초광대역 무선통신 시스템의 성능 분석)

  • Kim, Eun-Cheol;Kim, Sung-Ill;Park, Jae-Sung;Kim, Jin-Young
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.30-34
    • /
    • 2008
  • In this paper, we analyze the performance of pulse position modulation-time hopping ultra wide band (PPM-TH UWB) systems with antenna diversity technique in indoor wireless channel. A modified Saleh and Valenzuela (SV) model is adopted as a UWB indoor channel model. Perfect synchronization between a transmitter and a receiver is assumed. Therefore, coherent equal gain combining (EGC) scheme to collect the energy available in the multipath components is investigated. It is shown that the performance is improved by increasing the number of antennas at the receiver. The results of this paper can be applied to the applications of UWB.

  • PDF

Time-dependent Analysis of Optical Receivers Using Receiver Eigenmodes

  • Seo, Kyung Hee;Lee, Jae Seung;Willner, Alan E.
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.305-311
    • /
    • 2013
  • Using receiver eigenmodes, we perform a time-dependent analysis of optical receivers whose optical inputs are corrupted by the amplified spontaneous emission. We use Gaussian receivers for the analysis with Gaussian input pulses. We find the number of contributing eigenmodes increases as the measurement time moves from the pulse center towards the pulse edges at the output of the optical receiver's electrical filter. This behavior is dependent on the bandwidth ratio between the optical and the electrical filters as well as the input pulse's time width.

Comparative study of the pulse shape discrimination (PSD) performance of pixelated stilbene and plastic scintillator (EJ-276) arrays for a coded-aperture-based hand-held dual-particle imager

  • Jihwan Boo ;Manhee Jeong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1677-1686
    • /
    • 2023
  • As the demand for the detection of special nuclear materials (SNMs) increases, the use of imaging instruments that can sensitively image both gamma-ray and neutron signatures has become necessary. This study compared the pulse shape discrimination (PSD) performance of gamma/neutron events when employing either a pixelated stilbene or a plastic (EJ-276) scintillator array coupled to a silicon photomultiplier (SiPM) array in a dual-particle imager. The stilbene array allowed a lower energy threshold above which neutron and gamma-ray events can be clearly distinguished. A greater number of events can, therefore, be used when forming both gamma-ray and neutron images, which shortens the time required to acquire the images by nearly seven times.

Deterioration Diagnosis of Epoxy Mold-type Transformer Using Ultrasonic Waves (초음파를 이용한 에폭시 몰드변압기의 열화 진단)

  • 이상우;김인식;이동인;이광식;이동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.73-81
    • /
    • 1999
  • Measurements of ultrasonic signals caused by partial discharges were perlonnrl by using an ultrasonic measurement technique to diagnose the electrical treeing deterioration in an epoxy mold-type power transformer. We also examined the characteristics of tree growth, partial discharge magnitude and ultrasonic pulse number with the increase of the deterioration time. From these results, it was found that the shape of the tree was a branch-type, and the rates of the tree growth were examined when ac voltages of 16[kV] and 20[kV] were applied Ultrasonic pulse number and discharge magnitude were rapidly increased as the length of the tree grows after the middle stage of the deterioration time, and it appeared that ultrasonic pulse number was proportional to discharge magnitude. Attenuation, time-delaying and directivity characteristics of ultrasonic signals propagated into epoxy resin by using ultrasonic oscillation and receiving systems are also re[prted as a basic data of ultrasonic mesasurements in mold-type power transformer.former.

  • PDF

Study about a density (ph) change of an alkaline ion by PWM voltage control necessary for a living body (PWM 전압제어로 생체에 필요한 알칼리 이온수의 농도(ph)변화에 관한 연구)

  • 권윤중;이성창
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.6
    • /
    • pp.37-42
    • /
    • 2004
  • It is necessary for what just keep a living body balance be devoted to it being varied with acidity serious trouble, and constitution of a study person about the density (ph) change that an alkaline ion necessary for a living body is numerical to supply a human body with number alkali by PWM voltage control. Works in the water which included the calcium (Ca), kalium (K), magnesium (Mg), natrium (Na) back who is helpful for a human body, and there is Alkaline. It is done this alkaline electrolysis to ask in order to create a number, and minerals are gathered through isolated layer (isolated special layer) to a - electrode direction, and is created. of course, prominent derelicts gather, and the acidity capital is happened, and -ion of a chlorine (Cl), phosphorus(P), sulfur (S) back is usable unfavorably in water of different use to a + electrode direction. Microprocessor was used with a - pole and a + pole with a PWM(pulse width modulation) voltage in this electrolysis process, and four kinds of PWM voltages were implemented, and a voltage every ph density change tried to be considered. It is expected by getting exactly if number alkaline ion of ph density value necessary is done with setting value if PWM control is used thus.

The Characteristics of Dye Jet and Dye Laser Output Depending on the Reynold's Number (레이놀드 수에 따른 색소 젯트의 특성 및 색소레이저의 출력변화)

  • Kim, Sung Ho;Ko, Do-Kyeong;Lee, Jong-Min;Lim, Gwon;Jo, Jae-Heung;Chang, Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.461-465
    • /
    • 1994
  • The spatial flatness of dye jet depending on the Reynold's number has analyzed by using a Michelson interferometer. When the Reynold's number of dye jet was 600, the flatness of the flow was the best. Under this condition, the dye laser with Littman-type configuration has been operated in a single longitudinal mode at the pumping energy of 0.5~1.0 mJ/pulse. The conversion efficiency and beam divergence were 4.7% and 3 mrad, respectively. ively.

  • PDF

Study on Implant Cleaning Effect of Lasers of Different Wavelengths (파장이 다른 레이저의 임플란트 세정 효과에 관한 연구)

  • Park, Eun Kyeong;Yang, Yun Seok;Lee, Ka Ram;Yoo, Young Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.4
    • /
    • pp.643-651
    • /
    • 2013
  • This study applied a laser cleaning method (dry cleaning) that is used for cleaning semiconductor elements to dental implant cleaning. The lasers used in this study were pulsed fiber lasers with wavelengths of 1,064 and 532 nm. The peak output, energy per pulse, energy density per pulse, time of pulse experiment, and number of pulse experiments served as process variables for this study, and the variables were changed for each experiment. As a result, a laser with a wavelength of 532 nm showed much higher cleaning efficiency than its 1,064 nm counterpart. As the wavelength range decreased, the quantized energy increased and the reflection rate of the titanium used for the implant decreased; consequently, the energy absorption rate increased. Therefore, it is proposed that the energy density by wavelength has a greater influence on cleaning than does the output size.

Performance Analysis of OFDM/QPSK-DMR System Using Band-limited Pulse Shaping Filter over the Microwave Channel (Microwave 채널 환경에서 대역 제한 필터를 적용하는 OFDM/QPSK-DMR 시스템의 성능 분석)

  • Ahn, Jun-Bae;Yang, Hee-Jin;Oh, Chang-Heon;Cho, Sung-Joon
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.384-388
    • /
    • 2003
  • In this paper, we have proposed a OFDM/QPSK-DMR(Orthogonal frequency Division Multiplexing/Quadrature Phase Shift Keying Modulation-Digital Microwave Radio)system using BL-PSF(Band-limited pulse shaping filter) over the Microwave channel. In the proposed DMR system, STS-1(51.84 Mbps) of SONET(Synchronous Optical NETwork) is first modulated by OFDM/QPSK symbol and used Band-limited pulse shaping filter. The advantage of the proposed DMR system is to simplify system complexity and increase IFFT/FFT block use-efficiency. The system performance of single carrier and OFDM systems is already proved that those of DMR systems have the same performance over AWGN(Additive White Gaussian Noise) channel environment. Therefore, the system is analyzed between proposed OFDM/QPSK-DMR and single carrier DMR systems and simulated by BER performance and Signature curve over Microwave channel environment. Simulation result is that the proposed system performances are approaching to the performance of single carrier DMR system as the number of Sub-carriers increasing.

  • PDF

Heat Transfer Coefficient and Shear Factor Subjected to Both Oscillating Flow and Oscillating Pressure in Pulse Tubes (주기적인 유동과 압력의 변화를 수반하는 맥동관의 열전달계수와 전단계수)

  • Jeong, Eun-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.3
    • /
    • pp.220-227
    • /
    • 2007
  • Heat transfer and momentum transfer under conditions of both oscillating flow and oscillating pressure within pulse tubes show very different behavior from those for steady state conditions. The analytic solutions of axial velocity and temperature of the gas within pulse tubes were obtained by assuming that the variations in pressure and temperature were purely sinusoidal and small. The shear stress and the heat flux at the tube wall obtained from the solutions are expressed in terms of the cross-sectional averaged velocity, the difference between mean temperature and instantaneous cross-sectional averaged temperature and the difference between mean pressure and instantaneous pressure. It is shown that the complex shear factor, which has been applied to momentum transfer of incompressible oscillating flow, and the complex Nusselt number, which has been applied to either heat transfer with oscillating pressure only or heat transfer of incompressible oscillating flow, could also be used for momentum transfer and heat transfer subjected to both oscillating flow and oscillating pressure, respectively.