• 제목/요약/키워드: pulse generator

검색결과 445건 처리시간 0.026초

공관전압벡터 전류제어기법을 이용한 영구자석형 풍력발전기의 출력제어 (Output Power Control of Permanent Magnet Wind Power Generator with Space Voltage Vector Current Control Strategy)

  • 최종석;김시경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.361-364
    • /
    • 2000
  • In this study, the system which can make the generator's output voltage more stable by using the inverter in terms of PWM method, is designed It is one of the method reducing velocity of the wind in the process of the wind power generation. Thus, in this system, it is necessary to use a excellent current control inverter. So pulse with modulation method with a high-speed switching element is introduced to control the output current. And also, in order to get a fast response when the standard current generated by the vector control algorithm is supplied with the generator, the output control system with the fast response character and the best current control character is suggested. In this way, the result from the introduction of the control system is that a response character to the changable velocity of the wind is excellent, causing the remarkable reduction of the percentage of the harmonic and the outstanding stability of the variation of the output voltage.

  • PDF

Capacitive Switching Antenna의 최적 에너지 전달에 관한 연구 (A Study on Optimizing Energy Transfer of Capacitive Switching Antenna)

  • 김진만;방정주;허창수
    • 전기학회논문지
    • /
    • 제62권2호
    • /
    • pp.232-238
    • /
    • 2013
  • In this paper we describe the maximum energy transfer of CSA(Capacitive Switching Antenna). CSA which is radiated antenna system contain energy storage and switch, antenna needs to high voltage source for electrical field radiation experiment. In this experiment we employed Marx generator as a charging source. CSA can radiate electrical field more efficiently by varying antenna capacitance. The electromagnetic generation system which was using CSA has some advantages which are more simple and more effective compared to exist system. We evaluated the performance of electromagnetic wave generating system using CSA. As a result UWB gain of system is 0.47, It is higher level than exist system is 0.3. Radiated electrical field strength at 1m is 70kV/m. It is measured by D-dot sensor and gap distance is 20mm. Center frequency of CSA is approximately 25MHz. When vary the antenna gap distance from 50mm to 20mm, we can find the radiation field strength is decrease and antenna center frequency is increased. We also simulated the energy transfer efficiency to compare with experiment result. Consequentially, CSA needs to appropriate capacitance which is similar value from marx generator for maximum energy transfer, and gap is less than 1mm to increase the CSA capacitance.

MEASUREMENT OF THE D-D NEUTRON GENERATION RATE BY PROTON COUNTING

  • Kim, In-Jung;Jung, Nam-Suk;Choi, Hee-Dong
    • Nuclear Engineering and Technology
    • /
    • 제40권4호
    • /
    • pp.299-304
    • /
    • 2008
  • A detection system was set up to measure the neutron generation rate of a recently developed D-D neutron generator. The system is composed of a Si detector, He-3 detector, and electronics for pulse height analysis. The neutron generation rate was measured by counting protons using the Si detector, and the data was crosschecked by counting neutrons with the He-3 detector. The efficiencies of the Si and He-3 detectors were calibrated independently by using a standard alpha particle source $^{241}Am$ and a bare isotopic neutron source $^{252}Cf$, respectively. The effect of the cross-sectional difference between the D(d,p)T and $D(d,n)^3He$ reactions was evaluated for the case of a thick target. The neutron generation rate was theoretically corrected for the anisotropic emission of protons and neutrons in the D-D reactions. The attenuations of neutron on the path to the He-3 detector by the target assembly and vacuum flange of the neutron generator were considered by the Monte Carlo method using the MCNP 4C2 code. As a result, the neutron generation rate based on the Si detector measurement was determined with a relative uncertainty of ${\pm}5%$, and the two rates measured by both detectors corroborated within 20%.

소형 밀리미터파 추적 레이다용 모의신호 발생장치 개발 (Development of Simulated signal generator for Small Millimeter-wave Tracking Radar)

  • 김홍락;박승욱;우선걸;김윤진
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권3호
    • /
    • pp.157-163
    • /
    • 2019
  • 대함용 소형 밀리미터파 추적 레이다는 저속으로 기동 중인 큰 RCS를 갖는 바다위의 함정 표적에 대하여 TWS(Track While Scan) 방식을 통하여 실시간으로 표적을 탐색, 탐지 하여 추적하는 펄스 방식의 레이더이다. 본 논문에서는 소형 밀리미터파 추적 레이다의 성능을 실험실 무반향 챔버 환경에서 확인하기 위한 모의신호 발생장치 개발에 대하여 서술한다. 추적 레이다용 모의신호를 생성하기 위한 요구사항과 요구사항을 충족하기 위한 모의신호 발생장치의 하드웨어 구성과 추적 레이다와 연동하여 시험을 하고 성능을 분석하기 위한 GUI 프로그램을 기술하고 성능시험을 통해 구현한 모의신호 발생장치를 검증하였다.

순시 자속과 펄스전압 인가를 이용한 위치센서 없는 SRG의 구동 (The Position Sensorless Control SRG using the Instantaneous Flux and the Pulse Voltage)

  • 최양광;김영석;오승보;김영조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1161-1164
    • /
    • 2002
  • The position information of the rotor are required while the SRG(Switched Reluctance Generator) is drived. The position information is generally provided by shaft encoder or resolver. But it is weak in the dusty, high temperator and EMI environment. Therefore, It is required for the sensor to be eliminated from SRG. In this paper, a estimation algorithm for the rotor position of the SRG is introducted and a constant DC-link voltage is controled by PID controller. The estimation algorithm is imple--mened by using the instantaneous flux profile, and the initial position is estimated by injecting high frequency pulse voltage. It is proved that the rotor position is esti--mated very well by the exeriments.

  • PDF

A Switched VCO-based CMOS UWB Transmitter for 3-5 GHz Radar and Communication Systems

  • Choi, Woon-Sung;Park, Myung-Chul;Oh, Hyuk-Jun;Eo, Yun-Seong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권3호
    • /
    • pp.326-332
    • /
    • 2017
  • A switched VCO-based UWB transmitter for 3-5 GHz is implemented using $0.18{\mu}m$ CMOS technology. Using RF switch and timing control of DPGs, the uniform RF power and low power consumption are possible regardless of carrier frequency. And gate control of RF switch enables the undesired side lobe rejection sufficiently. The measured pulse width is tunable from 0.5 to 2 ns. The measured energy efficiency per pulse is 4.08% and the power consumption is 0.6 mW at 10 Mbps without the buffer amplifier.

응집입자와 비응집 입자의 CNC 내에서 응축성장에 관한 실험적 연구 (The growth effect of agglomerated and nonagglomerated particles in Condensation Nuclei Counter (CNC))

  • 김영원;문형우;윤진욱;안강호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.579-584
    • /
    • 2001
  • Agglomerated and nonagglomerated SiO2 particles are synthesized in furnace by the electrohydrodynamic spraying method and the vapor feeding method for the test particle generator this study. These polydispersed particles are classified with DMA to extract equal mobility particles. Then these particles are introduced into CNC (Condensation Nuclei Counter) to see the pulse height using Multi-channel Analyzer. The response characteristics of these two kinds of particles in CNCs (TSI CNC 3022 and 3025A) have been studied as a function of particle size using mono disperse particles classified by DMA. The results show that the higher drag resistance particles, so called agglomerated particles have generated a lower CNC pulse height than the spherical particles for these two different CNCs, which means the nonagglomerated particles may start to grow larger than the agglomerated particles.

  • PDF

플라즈마 발생장치용 공진형 인버터 전력변환장치 (A Resonant Type Inverter Power Conversion Equipment for Plasma Generator)

  • 김주용;서기영;문상필;정장근;김영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.162-165
    • /
    • 2003
  • A resonant type voltage source and power device and a control method using Pulse Density Modulation(PDM) power control and Pulse Width Modulation(PWM)voltage control for plasma sterilization are described. For the stability of discharge in the generating tube, it is desirable that the peak apply voltage is constant. The PDM power control is employed for sustaining the voltage constant at any generating tube input power. Moreover, to avoid the influence of input AC voltage fluctuation etc., PWM voltage control with generating tube peak voltage feedback is used. Both functions were confirmed by the experiment with inverter and generating tube. The effect of input synchronous PDM method for input current stabilizing is confirmed also.

  • PDF

압전트랜스듀서를 이용한 비파괴검사장치에 관한 연구 (A Study on the NDT System U sing Piezoelectric Transducers)

  • 황현석;송준태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1594-1596
    • /
    • 1996
  • The NDT(nondestructive test) using pulse echo method with piezoelectric transducers and the system for NDT including image processing were studoed. The system consisted of pulse generator and receiver, two step motors for X-Y scanner, PC-Scope for data aquisition and PC-Lab for trigger and motor driving. We tested and estimated at one point under the following conditions : 1) just water, 2) Aluminum without any crack and 3) Aluminum with hole. The estimated NDT result of whole area (point : $35{\times}20$) is compared with real samples.

  • PDF

변압기의 권선변형 검증을 위한 LVI 시험기 개발 (The Development of LVI Tester for WInding Deformation Measurement in Power Transformers)

  • 조국희;김광화;곽희로
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.251-256
    • /
    • 2000
  • The assessment of the condition of a transformer winding which is suspected of having suffered short circuit damage can be difficult. Conventional test such as winding resistance, magnetisation current or insulation resistance will only detect damage if a permanent electrical fault exists. Visual inspection of windings necessitates the removal of oil and in many cases only a very small proportion of the winding can be seen. We describe the characteristics. As the front rise time of recurrent-surge generator pulse less than 1000ns and the peak value of pulse is about 500V, we have the good results of detecting winding deformation in the LVI test of transformers.

  • PDF