• Title/Summary/Keyword: pulse generation

Search Result 498, Processing Time 0.03 seconds

A study on High Voltage Squarewave Pulse Generator (고전압 구형파 펄스 발생기에 관한 연구)

  • Kim, Young-Bae;Ryu, Hong-Je;Kim, Jong-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1022-1025
    • /
    • 2008
  • This paper presents the generation of the high voltage squarewave pulse using distributed RLC circuit. The demonstrated test was performed with the distributed RLC circuit which consists of the resistance, the inductance and the capacitance. Pspice simulation was also conducted about the experiment circuit. The result of the experiment was in good agreement with the result of the simulation. Theoretical analysis of the initial peak value at the squraewave pulse was derived from the results of the experiment and simulation. Additionally, the characteristics of the time delay was analyzed about the spherical gap switch and the surface discharge gap switch, respectively. It is concluded that the surface discharge gap switch is better than the spherical gap switch to reduce the time delay.

Characterization of behaviors using electric pulse for phase switching operation of Ge2Sb2Te5 material

  • Lee, Hyeon-Cheol;Choe, Du-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.322-322
    • /
    • 2016
  • Phase change memory (PCM) has attracted much attention as one of the most promising candidates for next-generation nonvolatile memory. In that regard, the purposes of the study are to propose reference of effective pulse parameter to control phase switching operation and to invest the effect of nitrogen doped in PCM materials for improved cycling stability and economic energy consumption. Switching operation of PCM is affected by electric pulse parameter and as shown in figure.1 are composed to RT(rising time), ST(setting time), FT(falling time) and the effect of these parameter was precisely investigated. Transmission electron microscope (TEM) was used to confirm fine structure and retention cycle test was conducted to confirm reliability. Finally improvement reliability and economic power consumption in quantitatively are obtainable by optimum pulse parameter and nitrogen doping in GST material. these study is related to the engineering background of other semiconductor industries and it have confirmed to possibility further applications.

  • PDF

Current Control Type Pulse Width Modulation by Using Pair Transistor Circuit (쌍트란지스터 회로에 의한 전류제어형 펄스변조)

  • 오현위
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.4
    • /
    • pp.7-16
    • /
    • 1971
  • A negative resistance element in the form of current control can be obtained by using a pair transistor circuit. This negative resistance element can be used in the generation of square pulse, and also in the realization of pulse width modulation circuit by superposing signal current on its bias current. The each bias current of pair circuit increases alternatively according to the polarity of the input signal. In order to satisfy this condition, a modified full wave rectification circuit has been adopted for supplying the input signal. Theoritical analysis of pulse times and design guidances for practical modulation circuit parameters are presented.

  • PDF

Higher-order soilton puliton pulse generation and compression in dispersion decreasing fiber for optical time division multiplexing system source applications (분산감소광섬유에서의 고차 솔리통 펄스 생성 및 압축을 통한 광시간분할다중시스템 광원의 제작에 대한 연구)

  • 이덕기;김나영;박남규
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.2
    • /
    • pp.102-107
    • /
    • 2000
  • We propose a new scheme for generating a pedestal-free, femtosecond soliton pulse train by utilizing quasI-adiabatic high order soliton pulse evolution in dispersion decreasing fiber in conjunction with the intermediate pedestal suppression stage. Compression factor over 280 was achieved from lOGHz sinusoidal input, to 176 is soliton pulse train. train.

  • PDF

High voltage Pulse Transformer for Pulsed Power Supply (펄스파워전원용 고전압 펄스변압기)

  • Kim, Jong-Hae;Ku, Chi-Wuk;Choi, Y.W.;Lee, H.S.;Rim, K.H.;Ko, Kwang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1755-1757
    • /
    • 1998
  • Pulse transformers have been developed to apply for pulsed power technology as an alternative of a Marx generator. To obtain repetitive pulsed power generation, it is necessary to observe the rising time of output of pulse transformer. In this paper, using the equivalent circuit, The rising wave of output of pulse transformer is simulated for various input wave by using the Electromagnetic transient program(EMTP).

  • PDF

A Study on the Very Fast Rising High Voltage Pulse Using Distributed Circuit (분포정수회로를 이용한 고전압 급준 펄스 연구)

  • Kwak, Hee-Ro;Kweon, Dong-Jin;Song, Ill-Gun
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.274-277
    • /
    • 1994
  • This paper describes a very fast rising high voltage pulse generation for studying surge phinomenon and prebreakdown of liquid dielectric by appling the traveling wave theory of the distributed circuit. This very fast rising high voltage pulse generator consists of a charging coaxial cable, a discharging switch, and a terminating resistance. As results, the rising time of pulses are about 31(nsec), which is very fast, and its duration is 950[nsec] when using 200[m] coaxial cable. The length of the coaxial cable and changing voltage can regulate the duration and the amplitude or the polarity of the pulse. When terminated the resistance, capacitor and inductor, the measured waveform corresponds with simulated waveform.

  • PDF

A Novel Pulse Density Modulated High Frequency Inverter for Streamer Reactor (스트리머 발생을 위한 새로운 PDM 고주파 인버터)

  • Kim, J.Y.;Mun, S.P.;Suh, K.Y.;Lee, H.W.;Jung, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.223-225
    • /
    • 2005
  • This paper presents a novel prototype of a current source resonant inverter using insulated gate bipolar transistors for driving a streamer reactor, streamer generation technology has been recognized as one of the best methods for water treatment, disinfection, industrial wastes utilization, and so on. However, some technological difficulties related to efficient streamer production have been significant problems restricting streamer usage in the industrial plants. Introduced in this paper is a pulse density modulated high frequency inverter for a plasma generate, which is developed with the aim to improve power conversion and control characteristics of the streamer reactor by using advances in power electronic technology. The developed system implements the feedforward control-based pulse density modulation control scheme with pulse width modulation feedback control strategy to compensate temperature and other environmental influences on streamer discharge.

  • PDF

Suggestion on an Innovative Pulse Diagnosis System based on Technical Trend Analysis (맥진기술동향 조사를 통한 맥진기 개발방안 제안)

  • Lee, Yu-Jung;Lee, Jean;Kim, Jang-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.174-179
    • /
    • 2009
  • Arterial pulse palpation is an important diagnostic method in Oriental Medicine, particularly for obtaining information about a patient's health conditions or illness, or for confirming a diagnostic conclusion based on the patient's pulsation. The pulse analyzer is both a leading Oriental Medical equipment and a promising tool with such a strong industrial ripple effect that it was selected as one of the four strategic tools for world Oriental Medical instrument market domination at a recent survey. Although various pulse analyzers had been developed, however, most of these were not widely used for clinical diagnosis, due perhaps to lack of the appliance's reliability caused by its inability to reflect the requirements of the clinicians. Thus, in this thesis, the clinical requirements for the pulse analyzer were identified and analyzed by conducting a questionnaire survey among Oriental Medicine clinicians. By looking into the basic functions of a pulse analyzer, the required measurement time, and the medical insurance fee required were determined and among others, the appliance's specific requirements were determined. Moreover, by investigating on the latest patent trend, the technical elements that are needed for the development of a next-generation pulse analyzer were identified. Through these processes, the flow of the technology that must be developed for the pulse analyzer was determined, and the direction for the development of the specific pulse analyzer hardware, sensor, and diagnostic algorithm was identified and proposed.

Study on Timing Characteristics of High-Voltage Pulse Generation with Different Charging Voltages

  • Lee, Ki Wook;Kim, Jung Ho;Oh, Sungsup;Lee, Wangyong;Kim, Woo-Joong;Yoon, Young Joong
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.1
    • /
    • pp.20-28
    • /
    • 2018
  • The time synchronization of each sub-unit of a pulsed generator is important to generate an output high-power radio frequency (RF) signal. To obtain the time synchronization between an input RF signal fed by an external source and an electron beam produced by an electric pulse generator, the influence of different charging voltages on a delay and a rise time of the output pulse waveform in the electric pulse generator should be carefully considered. This paper aims to study the timing characteristics of the delay and the rise time as a function of different charging voltages with a peak value of less than -35 kV in the high-voltage pulse generator, including a trigger generator (TG) and a pulse-forming line (PFL). The simulation has been carried out to estimate characteristics in the time domain, in addition to their output high-voltage amplitude. Experimental results compared with those obtained by simulation indicate that the delay of the output pulses of the TG and PFL, which are made by controlling the external triggering signal with respect to different charging voltages, is getting longer as the charging voltage is increasing, and their rise times are inversely proportional to the amplitude of the charging voltage.

Square Pulse-Power Generation Using Capacitor Energy Source (캐패시터를 이용한 구형파 펄스전압발생 전원장치)

  • Rim, Geun-Hie;Choi, Young-Wook;Lee, Hong-Sik;Cho, Chu-Hyun;E.P., Pavlov
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.1936-1938
    • /
    • 1997
  • Depending on the energy storage-element they are categorized into two types. One is called voltage-fed type when capacitors are used as energy storage elements. The other goes by the name of current-fed which s utilizes inductors as energy storage elements. This paper deals with the basic concept of pulse-power generation in the view points of load matching for the voltage-fed type.

  • PDF