• Title/Summary/Keyword: pulse generation

Search Result 498, Processing Time 0.024 seconds

A study on appropriate ship power system for pulse load combine with secondary battery (펄스부하에 적합한 이차전지 연동형 선박 전력시스템에 관한 연구)

  • Oh, Jin-Seok;Lee, Hun-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.962-968
    • /
    • 2013
  • Problem of greenhouse gases associated with global warming and the world rise in fuel oil prices due to the depletion of fossil fuel has attracted attention. For this reason, maritime transport business, has shown interest in green-ship technology to reduce the consumption of fuel and reduce greenhouse gas for environmental protection. Power system of the ship is one of the most important factors for safe operation. Therefore, at design of ship power system, most of existing vessel used comparative large capacity generator in order to respond peak load such as bow thruster, crane and etc. In the navigation of ship, marine generators most would be operated at low load operation. In the low load operation of the generation rate of 50% or less, the operation efficiency of the generator it deteriorated, to consume more fuel oil. It also, it means that adversely effect the life of the generator. In this paper, studied how to apply for a secondary battery in container ship that relatively frequent arrival and departure in port. As a result, in order to apply the secondary battery to increase the operating efficiency of the generator during the voyage, it was confirmed that it is possible to reduce fuel consumption.

Neuroendocrine Control of Gonadotropin Secretion during the Menstrual Cycle

  • Ryu, Kyung-Za
    • The Korean Journal of Pharmacology
    • /
    • v.23 no.2
    • /
    • pp.57-75
    • /
    • 1987
  • Two modalities of gonadotropin secretion, pulsatile gonadotropin and preovulatory gonadotropin surge, have been identified in the mammals. Pulsatile gonadotropin secretion is modulated by the pulsatile pattern of GnRH release and complex ovarian steroid feedback actions. The neural mechansim that regulates the pulsatile release of GnRH in the hypothalamus is called "GnRH pulse generator". Ovarian steroids, estradiol and progesterone, appear to exert thier feedback effects both directly on the pituitary to modulate gonadotropin release and on a hypothalamic site to modulate GnRH release; estradiol primarily affects the amplitude while progesterone decreases the frequency of the pulsatile GnRH. Steroid hormones are known to affect catecholamine transmission in brain. MBH-POA is richly innervated by NE systems and close apposition of NE terminals and GnRH cell bodies occurs in the MBH as well as in the POA. NE normally facilitates pulsatile LH release by acting through ${\alpha}-receptor$ mechanism. However, precise nature of facilitative role of NE transmission in maintaining pulsatile LH has not been clearly understood. Close apposition of DA and GnRH terminals in ME might permit DA to influence GnRH release. Action of DA transmission probably is mediated by axo-axonic contacts between GnRH and DA fibers in the ME. Dopamine transmission does not normally regulate pulsatile LH release, but under certain conditions, increased DA transmission inhibit LH pulse. Endogenous opioid acts to suppress the secretion of GnRH into hypophysial portal circulation, thereby inhibiting gonadotropin secretion. However, an interaction between endogenenous opioid peptides and gonadotropin release is a complex one which involves ovarian hormones as well. LH secretion appears to be most suppressed by endogenenous opioids during the luteal phase, at a time of elevated progesterone secretion. The arcuate nucleus contains not only cell bodies for GnRH and ${\beta}-endorphin$ but also a dense aborization of fibers suggesting that GnRH release is changed by the interactions between GnRH and ${\beta}-endorphin$ cell bodies within the arcuate nucleus. The frequency and amplitude of pulsatile LH release seem to be increased during the preovulatory gonadotropin surge. Estradiol exerts positive feedback action on the hypothalamo-pituitary axis to trigger preovulatory LH surge. GnRH is also crucial hormonal stimulus for preovulatory LH surge. It is unlikely, however, that increased secretion of GnRH during the preovulatory gonadotropin surge represents an obligatory neural signal for generation of the LH discharge in primates including human. Modulation of preovulatory LH surge by catecholamines has been studied almost exclusively in rats. NE and E may be involved in distinct way to accumulate GnRH in the MBH and its release into the hypophysial portal system during the critical period for LH surge on proestrus in rats. However, the mechanisms whereby augmented adrenergic transmission may facilitate the formation and accumulation of GnRH in the ME-ARC nerve terminals before the LH surge have not been clearly understood.

  • PDF

Precise Estimation of Nonlinear Parameter in Pulse-Like Ultrasonic Signal (펄스형 초음파 신호에서 비선형 파라미터의 정밀 추정)

  • Ha, Job;Jhang, Kyung-Young;Sasaki, Kimio;Tanaka, Hiroaki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.2
    • /
    • pp.77-83
    • /
    • 2006
  • Ultrasonic nonlinearity has been considered as a solution for the detection of microcracks or interfacial delamination in a layered structure. The distinguished phenomenon in nonlinear ultrasonics is the generation of higher-order harmonic waves during the propagation. Therefore, in order to quantify the nonlinearity, the conventional method measures a parameter defined as the amplitude ratio of a second-order harmonic component and a fundamental frequency component included in the propagated ultrasonic wave signal. However, its application In field inspection is not easy at the present stage because no standard methodology has yet been made to accurately estimate this parameter. Thus, the aim of this paper is to propose an advanced signal processing technique for the precise estimation of a nonlinear ultrasonic parameter, which is based on power spectral and bispectral analysis. The method of estimating power spectrum and bispectrum of the pulse-like ultrasonic wave signal used in the commercial SAM (scanning acoustic microscopy) equipment is especially considered in this study The usefulness of the proposed method Is confirmed by experiments for a Newton ring with a continuous air gap between two glasses and a real semiconductor sample with local delaminations. The results show that the nonlinear parameter obtained tv the proposed method had a good correlation with the delamination.

Fabrication and characterization of $WSi_2$ nanocrystals memory device with $SiO_2$ / $HfO_2$ / $Al_2O_3$ tunnel layer

  • Lee, Hyo-Jun;Lee, Dong-Uk;Kim, Eun-Kyu;Son, Jung-Woo;Cho, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.134-134
    • /
    • 2011
  • High-k dielectric materials such as $HfO_2$, $ZrO_2$ and $Al_2O_3$ increase gate capacitance and reduce gate leakage current in MOSFET structures. This behavior suggests that high-k materials will be promise candidates to substitute as a tunnel barrier. Furthermore, stack structure of low-k and high-k tunnel barrier named variable oxide thickness (VARIOT) is more efficient.[1] In this study, we fabricated the $WSi_2$ nanocrystals nonvolatile memory device with $SiO_2/HfO_2/Al_2O_3$ tunnel layer. The $WSi_2$ nano-floating gate capacitors were fabricated on p-type Si (100) wafers. After wafer cleaning, the phosphorus in-situ doped poly-Si layer with a thickness of 100 nm was deposited on isolated active region to confine source and drain. Then, on the gate region defined by using reactive ion etching, the barrier engineered multi-stack tunnel layers of $SiO_2/HfO_2/Al_2O_3$ (2 nm/1 nm/3 nm) were deposited the gate region on Si substrate by using atomic layer deposition. To fabricate $WSi_2$ nanocrystals, the ultrathin $WSi_2$ film with a thickness of 3-4 nm was deposited on the multi-stack tunnel layer by using direct current magnetron sputtering system [2]. Subsequently, the first post annealing process was carried out at $900^{\circ}C$ for 1 min by using rapid thermal annealing system in nitrogen gas ambient. The 15-nm-thick $SiO_2$ control layer was deposited by using ultra-high vacuum magnetron sputtering. For $SiO_2$ layer density, the second post annealing process was carried out at $900^{\circ}C$ for 30 seconds by using rapid thermal annealing system in nitrogen gas ambient. The aluminum gate electrodes of 200-nm thickness were formed by thermal evaporation. The electrical properties of devices were measured by using a HP 4156A precision semiconductor parameter analyzer with HP 41501A pulse generator, an Agillent 81104A 80MHz pulse/pattern generator and an Agillent E5250A low leakage switch mainframe. We will discuss the electrical properties for application next generation non-volatile memory device.

  • PDF

Optimal Method of Radon Analysis in Groundwater using Ultra Low-Level Liquid Scintillation Counter (극 저준위 액체섬광계수기를 이용한 지하수 중 라돈($^{222}Rn$) 측정법 연구)

  • Kim Yong-Je;Cho Soo-Young;Yoon Yoon-Yeol;Lee Kil-Yong
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.5
    • /
    • pp.59-66
    • /
    • 2006
  • Optimal method of radon analysis in groundwater was studied using ultra low-level liquid scintillation counter (ULLLSC) which is well known as an analytical instrument for analyzing the alpha and beta radionuclides in environmental materials. Optimization of pulse shape analyzer (PSA) in operating the LSC was performed with $^{241}Am\;and\;^{90}Sr/^{90}Y$ as well as $^{226}Ra$ Also, the chemical quenching of scintillation generation and the color quenching of the generated photon to photomultiplier tubes (PMT) were determined their effects not only to decrease the analytical efficiency but also to change the optimal PSA level and background due to high ion contents of groundwaters. The optimal PSA level was shown in the range of 90 to 110 with less than 5% error. The effects of high ion contents in groundwater for the analytical efficiency show within 10% error from the different ion contents. The chloroform as a quenching agent was used to determine the analytical efficiency with the different amount, showing that the efficiency decreases 20% using the 2% of chloroform.

Terahertz Generation and Detection Using InGaAs/InAlAs Multi Quantum Well

  • Park, Dong-U;Han, Im-Sik;No, Sam-Gyu;Ji, Yeong-Bin;O, Seung-Jae;Seo, Jin-Seok;Jeon, Tae-In;Kim, Jin-Su;Kim, Jong-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.205-205
    • /
    • 2013
  • 테라헤르쯔(terahertz: THz)파는 0.1~10 THz 의 범위로 적외선과 방송파 사이에 광대역 주파수 스펙트럼을 차지하고 있으며 직진성, 투과성, 그리고 낮은 에너지 (meV)를 가지고 있어 비 파괴적이고 무해한 장점을 지니고 있다. Ti:sapphire laser와 같은 femto-pulse source 등이 많은 발전이 되어 현재 많은 연구와 발전이 이루어지고 있다. femto-pulse source를 이용한 THz 응용에서는 높은 저항, 큰 전자 이동도, 그리고 아주 짧은 전하수명의 기판을 요구하는데 저온에서 성장한 (low-temperature grown : LT) GaAs는 격자 내에 Gallium 자리에 Arsenic이 치환 하면서 AsGa antisite가 발생하여 전하수명을 짧아지는 것을 응용하여 가장 많이 이용되고 있다. 현재 THz 응용분야에서 보다 작고 가격경쟁력이 있는 광통신을 이용한 THz photomixer등이 활발히 연구 하고 있다. 광섬유 내에서 손실과 분산이 최소값을 가지는 부분이 1.55 ${\mu}m$ 부근이고 In0.53Ga0.47As 기판을 이용하였을 때 여기에 완벽하게 만족하게 된다. 하지만 LT-InGaAs 의 경우 AsGa antisite로 인하여 carrier lifetime은 짧아지지만 높은 n-type 전하밀도를 가지게 된다. 이때 Be을 doping하여 전하밀도를 보상하여 높은 저항을 유지해야 하는데 Be의 활성화를 위해서는 열처리를 필요로 한다. 하지만 열처리를 하면 carrier lifetime이 길어지기 때문에 carrier lifetime과 저항을 적절히 조율해야 한다. 이는 물질자체의 특성이기 때문에 InGaAs는 GaAs보다 낮은 amplitude와 짧은 cut-off frequency를 가진다. 본 연구에서는 보다 높은 저항을 얻기 위하여 molecular beam epitaxy를 이용하여 semi-insulating InP:Fe 기판위에 격자 정합된 InGaAs:Be/InAlAs multi quantum well (MQW)를 온도별 ($250{\sim}400^{\circ}C$), 주기별 (50~150)로 성장을 하였고 이때 InGaAs layer의 Be doping level은 $2{\times}1018\;cm^{-3}$, Ex-situ annealing은 $550^{\circ}C$에서 10분으로 고정 하였다. THz 발생 실험에서는 InGaAs/InAlAs MQW은 4000 pA로 1,000 pA를 가지는 InGaAs epilayer보다 4배 높은 전류 신호를 얻을 수 있었고 모든 샘플이 2 THz에서 cut-off frequency를 가지고 있었다. THz 검출 실험에서는 LT-InGaAs:Be epilayer LT-InGaAs:Be/InAlAs, HT-InGaAs/InAlAs 샘플이 각각 180, 9000, 12000 pA의 전류신호를 가지고 있었고 모든 샘플이 2 THz에서 cut-off frequency를 가지고 있었다. HT-InGaAs/InAlAs MQW를 이용한 검출실험에서는 InGaAs layer가 defect free이지만 LT-InGaAs:Be/ InAlAs MQW 보다 높은 전류 신호를 얻을 수 있었다. 이는 InAlAs layer가 저항만 높이는 것뿐만 아니라 carrier trapping layer로써의 역할도 하는 것으로 사료된다.

  • PDF

Waveform characteristics of ultrasonic wave generated from CNT/PDMS composite (CNT/PDMS 복합체로부터 방사된 초음파의 파형 특성)

  • Kim, Gisuk;Kim, Moojoon;Ha, Kanglyeol;Lee, Jooho;Paeng, Dong-Guk;Choi, Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.459-466
    • /
    • 2019
  • When a laser pulse is irradiated on a CNT (Carbon Nanotube) and PDMS (Poly dimethylsiloxane) composite coated on a transparent PMMA (Poly methyl methacrylate) substrate, a strong ultrasonic wave is generated due to the thermoelastic effect. In this paper, the thermoacoustic theory related to the wave generation by the CNT/PDMS composite was established. The waveforms of ultrasonic waves when a laser pulse having a Gaussian waveform is irradiated on the composite with a thickness of $20{\mu}m$ were numerically simulated. From the results, it was confirmed that ultrasonic shock waves can be generated from the CNT/PDMS composite and the waveforms are changed little even if the physical properties of the composite are changed by ${\pm}20%$. It was found that the peak positive and negative pressures increase as the thermal expansion coefficient increases, or as density, heat capacity and sound speed decreased. However, those changes were not so sensitive with thermal conductivity. In addition, the physical properties of the CNT/PDMS composite fabricated in this study were estimated from the comparison of the measurement and simulation results.

The Characteristics Analysis and Design of High-Frequency Isolated Type ZVZCS PS-PWM DC-DC Converter with Fuel Cell Generation System (연료전지 발전시스템에 적용된 고주파 절연형 ZVZCS PS-PWM DC-DC 컨버터의 설계 및 특성 해석)

  • Suh, Ki-Young;Mun, Sang-Pil;Kim, Dong-Hun;Lee, Hyun-Woo;Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.4
    • /
    • pp.21-28
    • /
    • 2006
  • In this paper, the proposed full-bridge high frequency isolated zoo voltage and zero current switching phase shifted pulse width modulation(ZVZCS PS-PWM)DC-DC converter among fuel cell generation system consist of 1.2[kW] fuel cell of Nexa Power Module, full-bridge DC-DC converter to boost the fuel cell low voltage($28{\sim}43[%]$) to 380[VDC] and a single phase full-bridge inverter is implemented to produce AC output(220[VAC], 60[Hz]). A tapped inductor filter with freewheeling diode is newly implemented in the output filter of the proposed full-bridge high frequency isolated ZVZCS PS-PWM DC-DC converter to suppress circulating current under the wide output voltage regulation range, thus to eliminate the switching and transformer turn-on/off over-short voltage or transient phenomena. Besides the efficiency of $93{\sim}97[%]$ is obtained over the wide output voltage regulation ranges and load variations.

Production of Second Generational Cloning Embryos with Activated Oocytes in Rabbits (토끼에서 수핵란의 세포질 활성화에 의한 제 2세대 복제수정란의 생산)

  • 이효정;윤희준;최창용;공일근;박충생;최상용
    • Journal of Embryo Transfer
    • /
    • v.12 no.2
    • /
    • pp.133-139
    • /
    • 1997
  • Large scale production of cloned embryos requires the technology of multiple generational nuclear transfer(NT) by using NT embryos itself as the subsequent donor nuclei. In this work we investigated comparatively the effects of enucleated oocytes treated with ionomycin and 6-DMAP on the electrofusion rate and in vitro developmental potential in the first and second NT embryos. The embryos of 16-cell stage were collected from the mated does by flushing oviducts with Dulbecco's phosphate buffered saline(D-PBS) containing 10% fetal calf serum(FCS) at 47 hours after hCG injection. The recipient cytoplasms were obtained by removing the nucleus and the first polar body from the oocytes collected at 15 hours after hCG injection. The enucleated oocytes were pre-activated by 5 min incubation in 5$\mu$M ionomycin and 2 hours incubation in 2 mM 6-DMAP at 19~20 hours post-hCG before microinjection. In the first and second generation NT, the unsynchronized 16-cell stage embryos were used as nuclear donor. The separated donor blastomeres were injected into the enucleated activated recipient oocytes by micromanipulation and were electrofused by electrical stimulation of single pulse for 60 $\mu$sec at 1.25kV/cm in $Ca^2$+, $Mg^2$+ - free 0.28 M mannitol solution. In the non-preactivation group, the electrofusion and electrical stimulation was given 3 pulses for 60 $\mu$sec at 1.25 kV/cm in 100$\mu$M $Ca^2$+, $Mg^2$+ 0.28 M mannitol solution. The fused oocytes were co-cultured with a monolayer of rabbit oviductal epithelial cells in TCM-199 solution containing 10% FCS for 120 hours at 39$^{\circ}C$ in a 5% $CO_2$ incubator. The results obtained were summarized as follows: 1. In the first generational NT embryos, the electrofusion rate of preactivated and non-activated oocytes(80.4 and 87.8%) was not significantly different, but in the second generational NT embryos, the electrofusion rate was significantly(P<0.05) higher in the non-activated oocytes(85.7%) than in the preactivated oocytes(70.1%). 2) In the first and second generational NT embryos, the developmental potential to biastocyst stage was significantly(P<0.05) higher in the preactivated oocytes(39.3 and35.7%) than in the non-preactivated oocytes(16.0 and 13.3%). No significant difference in the developmental potential was shown between the first and second generational NT embryos derived from the preactivated oocytes. In conclusion, it may be efficient to use the oocytes preactivated with ionomycin and 6-DMAP for the multiple production of cloned embryos by recycling nuclear transfer.

  • PDF

A Design of Key Generation and Communication for Device Access Control based on Smart Health Care (스마트 헬스케어 기반의 디바이스 접근제어를 위한 키 생성 및 통신기법 설계)

  • Min, So-Yeon;Lee, Kwang-Hyong;Jin, Byung-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.746-754
    • /
    • 2016
  • Smart healthcare systems, a convergent industry based on information and communications technologies (ICT), has emerged from personal health management to remote medical treatment as a distinguished industry. The smart healthcare environment provides technology to deliver vital information, such as pulse rate, body temperature, health status, and so on, from wearable devices to the hospital network where the physician is located. However, since it deals with the patient's personal medical information, there is a security issue for personal information management, and the system may be vulnerable to cyber-attacks in wireless networks. Therefore, this study focuses on a key-development and device-management system to generate keys in the smart environment to safely manage devices. The protocol is designed to provide safe communications with the generated key and to manage the devices, as well as the generated key. The security level is analyzed against attack methods that may occur in a healthcare environment, and it was compared with existing key methods and coding capabilities. In the performance evaluation, we analyze the security against attacks occurring in a smart healthcare environment, and the security and efficiency of the existing key encryption method, and we confirmed an improvement of about 15%, compared to the existing cipher systems.