• 제목/요약/키워드: pullout

검색결과 396건 처리시간 0.024초

지오그리드 보강재의 인발거동특성 예측기법 (Prediction of Pullout Behavior Characteristics on the Geogrid)

  • 김홍택;박사원;김경모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 토목섬유 학술발표회 논문집
    • /
    • pp.1-10
    • /
    • 1999
  • In the present study, laboratory pull-out tests with various geogrid shapes are carried out to investigate behavior characteristics of the geogrid. Also, an interface pullout formula is proposed for predicting and interpreting pullout test result. The analytical model is based on the assumption that the reinforcement is linear elastic during the pullout test. And then, maximum pullout force, frictional resistance and active length for each of the grid density ratio are predicted based on the interface pullout formula. The predicted results were compared with those of pullout tests, and showed in general good agreements.

  • PDF

Test of Headed Reinforcement in Pullout

  • Park, Dong-Uk;Hong, Sung-Gul;Lee, Chin-Yong
    • KCI Concrete Journal
    • /
    • 제14권3호
    • /
    • pp.102-110
    • /
    • 2002
  • Results of an experimental study on the pullout behavior of the headed reinforcement are presented. A total of 48 pullout tests was performed to evaluate pullout strengths and load-displacement behaviors in pullout of the headed bars. The square steel heads had gross area of 4 $A_{b}$ and thickness of $d_{b}$ The test program consisted of three pullout test groups: Simple and Edge pullout tests using plain concrete slabs, comparison of pullout performances between the standard hooks and the headed reinforcement, and pullout tests of headed reinforcement using reinforced concrete columns. Test variables included concrete strengths ( $f_{c}$' = 27.1MPa, 39.1MPa), reinforcing bar diameters (D16~D29), embedment depths (6 $d_{b}$~12 $d_{b}$), edge conditions, column reinforcement, and single-vs.-multiple bar pullout. Test results revealed that the heads effectively provided the pullout resistances of the deformed bars in tension. The load-displacement behaviors were similar between the 90-degree hooks and the headed reinforcement. When a multiple number of headed bars installed with small head-to-head spacings was pulled out, reinforcement designed to run across the concrete failure surface in a direction parallel to the headed bars helped improve the pullout performances of the headed reinforcement.t.ement.t.

  • PDF

Pullout Test of Retrofit Anchors using Deformed Reinforcement and Adhesive

  • Choi, Dong-Uk;Kim, Yon-Gon
    • KCI Concrete Journal
    • /
    • 제11권3호
    • /
    • pp.201-210
    • /
    • 1999
  • An experimental study was carried out to determine pullout behavior of a new type of anchor bolt that used deformed reinforcement and a commercial adhesive. Concrete slabs and columns with about 20-MPa compressive strength were used for 136 pullout tests performed. Test variables included anchor diameter (10 mm ~ 32 mm). embedment depth (10$\Phi$ or 15$\Phi$), edge effect. and Presence of transverse reinforcement in existing concrete. In Tyre-S test. where the edge or reinforcing steel effect was not included, the anchor Pullout strengths increased with increasing anchor diameters. Anchors with 15$\Phi$ embedment depth had higher Pullout strengths than those with 100 embedment depth The largest average Pullout load of 208 kN was determined for anchors made with D25 reinforcement and with 15$\Phi$ embedment depth. In Type-E tests, where the anchors were installed close to the edge of existing concrete, there were reductions in pullout strengths when compared to those determined in Type-S tests. In Type-ER tests, influence of the reinforcement in existing concrete on the anchor pullout strengths was examined using reinforced concrete and plain concrete columns Test results indicated that existing transverse reinforcement (column ties) did not help increase the pullout strength. The overall pullout test results revealed that the new anchor bolt can develop large pullout strengths while the anchors can be made of materials that are readily available in the market.

  • PDF

말뚝의 인발저항에 대한 지중 구속압 영향 분석을 위한 실내모형실험 (Effect of Ground Confine Pressure on Pullout Resistance of Piles Using Model Experiment)

  • 유승경;홍기권
    • 한국지반신소재학회논문집
    • /
    • 제22권4호
    • /
    • pp.27-34
    • /
    • 2023
  • 본 연구에서는 말뚝에 작용하는 구속압과 지반의 세립분 함유율을 고려한 말뚝 인발실험을 실시하였다. 그리고 실험 결과를 이용하여 말뚝의 인발저항에 미치는 지중 구속압의 영향을 분석하여 인발저항정수를 고찰하였다. 인발실험 결과, 모형지반의 세립분 함유율과 구속압의 크기에 관계없이 약 7mm~9mm의 인발변위에서 최대인발저항력이 발생되었다. 말뚝의 최대인발저항력은 모형지반의 세립분 함유율이 증가할수록 감소하였고, 이러한 경향은 구속압이 클수록 현격하게 나타났다. 말뚝인발실험 결과의 신뢰성을 검토하기 위해 인발저항력을 이론식으로 산정해 실험결과와 비교한 결과, 모든 구속압 조건에서 세립분 함유율 증가에 따라 실험값과 이론값 모두 동일하게 인발저항력이 감소하는 경향을 보였다. 인발저항정수에 대한 분석 결과, 말뚝과 지반의 경계에서 발생하는 인발저항력에 있어서 주변 지반의 세립분 함유율이 증가할수록 경계면 마찰각보다 부착력의 영향이 커지는 것을 확인하였다.

Pullout resistance of treadmats for reinforced soil structures

  • Kim, Keun-Soo;Yoon, Yeo-Won;Song, Ki-Il
    • Geomechanics and Engineering
    • /
    • 제14권1호
    • /
    • pp.83-90
    • /
    • 2018
  • A series of pullout tests were carried out on waste tire treadmats of various weave arrangements, with confining stresses ranging from 9 to 59 kPa approximately, in order to investigate the pullout behavior and to apply the results to the design of treadmat reinforced soil structures. A treadmat reinforcement can be considered as belonging to the extensible type thus progressive failure would develop in every tread. The pullout capacity of a treadmat was found to be generally equal to the sum of capacities of the longitudinal treads, with minor enhancement realized due to the presence of transverse treads. Pullout failures occurred in treadmats under light surcharge and with treadmats with higher material presence per unit area, while breakage failures occurred in treadmats under heavier surcharge and with treadmats with higher ratio of opening. The pullout capacity of a treadmat increased with increasing surcharge height and treadmat stiffness. A pullout test on a commercially available geogrid was also carried out for comparison and the pullout capacity of a treadmat was found higher than that of the comparable geogrid under identical loading conditions, indicating the merit of using the treadmat as an alternative to the chosen geogrid.

흙의 다짐도에 따른 인발저항특성 연구 (Pullout Resistance of Geogrid Reinforced Soil according to Compaction Degree)

  • 주재우;김병욱;박종범
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 토목섬유 학술발표회 논문집
    • /
    • pp.11-20
    • /
    • 1999
  • The method which makes the soft ground reinforced by using the geogrid, a kind of geosynthetics has been getting popular and its usefulness also has been increased due to reduction in costs, ease of construction and great exterior view, But the study on the frictional characteristics, which is the important factor in design, between reinforcement and soil is insufficient. In this study, compaction degrees were considered through large-scale pullout tests. As a part of studying on estimation of pullout frictional characteristics between soil and geosynthetics, pullout tests were peformed and from the result of pullout tests, pullout frictional parameters between soil and geosynthetics were obtained and pullout behaviors were learned.

  • PDF

Headed Reinforcement 인발실험 (Pullout Test of Headed Reinforcement)

  • 박명기;신인용;최동욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.203-208
    • /
    • 2001
  • Objectives of this study included design of head and evaluation of the pullout performance of the headed reinforcement that can be used to replace standard hooks in the building exterior beam-column joints. Results of 36 pullout tests are presented. Test variables included reinforcing bar diameters (16-25mm), embedment depth (6-7db), transverse reinforcement, and single-vs.-group pullout behavior. The square head designed had gross area of 4Ab and thickness of db. The headed reinforcement made of Dl6 bars developed pullout strengths close to the bar yield strength, but larger bars developed strengths smaller than the yield strengths. The pullout resistance increased with decreasing spacing of the transverse reinforcement. Use of column ties with 6.0-db spacing improved the pullout performance of the headed bars without causing difficulties in fabricating the specimens. The comparison of the pullout performances between the headed bars and the standard hooks revealed that strengths, stiffnesses, and ductile behaviors are about the same.

  • PDF

인발시험에 의한 저회에 보강된 폐어망의 인발특성 연구 (Pullout Characteristics of Waste Fishing Net Reinforced Bottom Ash using Pullout Test)

  • 권순장;김윤태
    • 한국지반신소재학회논문집
    • /
    • 제12권4호
    • /
    • pp.57-66
    • /
    • 2013
  • 본 연구에서는 산업폐기물인 저회와 폐어망을 각각 뒤채움 재료와 보강재로 재활용하기 위하여 저회와 폐어망 사이의 인발특성을 분석하였다. 이를 위해 저회로 구성된 지반에 망목크기가 다른 3종류의 폐어망(WFN20 : $20mm{\times}20mm$, WFN30 : $30mm{\times}30mm$, WFN40 : $40mm{\times}40mm$)과 지오그리드를 보강재로 사용하여 인발시험을 수행하였다. 인발시험 수행 결과, 지오그리드와 동일한 망목크기를 갖는 WFN20의 인발마찰각은 지오그리드와 유사하게 나타났다. 이것은 WFN20의 인장강도와 강성은 지오그리드 보다 작으나, WFN20의 두께가 지오그리드 보다 커서 횡리브에 의한 지지력이 발현되었기 때문이다. 보강재의 잔류변형률 분포는 연직응력에 의존한다. 연직응력이 증가함에 따라 보강재 선단에 인발력이 크게 집중되어 변형이 크게 나타난다.

신장성 지오그리드 보강재의 포설길이에 따른 인발정수 (Pullout Parameter According to the Length of Spreading of Extensible Geogrid Reinforcement)

  • 박종범;주재우;나현호
    • 한국지반신소재학회논문집
    • /
    • 제16권4호
    • /
    • pp.241-249
    • /
    • 2017
  • 보강토 구조물에서 흙과 보강재 상호작용은 접촉면 마찰저항 또는 보강재 인발저항에 의해 발생되며, 신장성 지오그리드 보강재의 인발정수를 측정하기 위하여 일반적으로 인발시험을 실시한다. 인발시험시 인발정수에 영향을 미치는 요소는 뒷채움재의 밀도, 보강재의 형상, 토피하중, 보강재의 포설길이 등이 있다. 본 연구에서는 인발시험시 합리적인 인발정수 산정을 위한 신장성 보강재의 포설길이를 제안하고자 인발시험을 실시하였으며, 보강재 포설길이는 각각 32cm, 52cm, 72cm, 100cm로 선정하였다. 인발시험결과 보강재 포설길이에 따른 인발정수의 영향을 분석하였으며, 인발시험에서 흙과 보강재사이의 마찰저항은 보강재 포설길이가 증가할수록 증가함을 확인하였다.

강보강재로 보강된 실트질 모래의 배수 및 비배수 인발력 (Drained and Undrained Pullout Capacity in Steel Strip Reinforced Silty Sands)

  • 이홍성
    • 한국지반공학회논문집
    • /
    • 제22권6호
    • /
    • pp.5-13
    • /
    • 2006
  • 지하수 급속저하와 같은 비배수 상태에서는 흙과 보강재 사이의 경계면(interface)에서 발생하는 과잉간극수압으로 인하여 유효응력이 감소할 수도 있으며, 이는 보강재의 인발력 감소로 이어지기도 한다. 본 연구에서는 각기 다른 종류의 흙(순수모래, 5, 10, 15, 35% 실트질 모래)과 상재하중(30, 100, 200kPa)을 대상으로 배수 및 비배수 실내인발시험을 실시하여 최대 배수인발력과 최대 비배수인발력을 서로 비교하였다. 시험결과 배수인발력과 비배수인발력 모두 실트 함유량에 의해 영향을 받고, 흙의 내부마찰각이 증가함에 따라 인발력 또한 증가하는 것으로 나타났다. 또한, 상재하중이 증가함에 따라 인발력도 증가하였으며, 최대인발력에 도달하는데 소요되는 인발거리도 증가하였다. 비배수 시험에서는 과잉간극수압이 발생함에 따라 보강재에 작용하는 유효응력이 감소하였으며, 그 결과 배수 조건과 비교하여 인발력과 인발거리가 감소하였다.