폴리머 시멘트 몰탈의 철근 부착특성 평가 (Bond Properties of Polymer Cement Mortar to Reinforced Steel Bar)

  • 박동천;조규환
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.106-107
    • /
    • 2013
  • The purpose of this study is to characterize the bonding properties between reinforced bar and re-emulsion polymer cement mortar through the pull off test. The properties of polymer cement mortar before and after hardening were measured. Spiral reinforced steel bar was used to control the brittleness fracture of test specimens. In addition polymer content as experimental factors, the types of reinforced bar and corrosion were considered as well. Non linear FEM analysis was carried out to expect the behavior of bonding interface under the certain load.

  • PDF

접착 테이프 박리거동에 미치는 외부효과에 관한 연구 (A Study on External Effects on Peeling-off Behavior of Adhesive Tape)

  • 한원흠;정형식;이문호
    • 접착 및 계면
    • /
    • 제13권1호
    • /
    • pp.9-16
    • /
    • 2012
  • 접착용 테이프 박리거동에 미치는 외부효과를 알아보고, 이를 설명하는 준강체 실린더 체인(semi-rigid body cylinder chain) 모델을 제안하였다. 먼저 평면으로부터 테이프를 떼어낼 때, 테이프의 거동을 정성적으로 파악하고, 이를 토대로 준강체 실린더 체인 모형을 도식화하였다. 그 다음 테이프를 떼어내는 힘에 미치는 여러 요소들(온도, 표면거칠기, 떼어내는 속도, 각도 의존성, 테이프 폭 등)의 효과와 이들의 민감도를 분석하여 동일한 실험 기준조건을 설정하고, 이 조건에서 평면으로부터 테이프를 떼어내는 힘(벡터)의 각도 의존성을 $10^{\circ}$ 간격으로 측정하였다. 실험결과는 본 연구에서 확립한 모형이론과 실험오차범위 내에서 잘 일치하였고, 다른 요소들의 효과는 현상론적 입장에서 정성적으로 잘 설명되었다. 이러한 이유로, 본 결과는 PSA 테이프의 접착력을 시험 평가하는 모델로 활용될 수 있을 것으로 기대된다.

구조보강용 FRP 복합체의 동결용해 저항성 평가 연구 (Freezing-Thawing Resistance of Fiber Reinforced Polymers in Strengthening RC Members)

  • 유영찬;최기선;김긍환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권1호
    • /
    • pp.182-189
    • /
    • 2010
  • 본 논문에서는 FRP 복합체로 보강된 콘크리트 구조물의 동결융해 저항성을 평가하기 위하여 동결융해 진행에 따른 FRP 복합체의 인장강도 및 콘크리트에 대한 인발접착강도의 변화를 측정하였다. 주 실험변수는 동결융해 조건, FRP 복합체의 종류, 동결융해 싸이클로 설정하였다. KS F 2456의 동결융해 시험규격에 따라 실시된 탄소섬유복합체의 인장강도는 최종 싸이클까지 변화가 없었으며, 또한 접착성능의 저하도 관측되지 않아 CFRP의 동결융해 저항성은 매우 우수한 것으로 나타났다. 이에 대하여 유리섬유복합체의 경우는 최종 싸이클에서의 인장강도 및 인발접착강도가 각각 10%, 15% 저하된 것으로 나타나 부분적으로 성능이 저하되는 것으로 나타났다. 그러나 접착강도 평가시 지속적인 동결수가 공급되는 상황에서는 상이한 결과가 나타날 수 있으므로 이에 대한 주의가 필요할 것으로 판단된다.

수중코팅제와 콘크리트 모재 간의 인장 부착 특성 (Tensile Bond Characteristics between Underwater Coating Materials and Concrete Substrate)

  • 김민욱;정연웅;강성훈;문주혁;이진학
    • 한국해안·해양공학회논문집
    • /
    • 제30권6호
    • /
    • pp.298-305
    • /
    • 2018
  • 본 연구에서는 해양 항만 콘크리트 구조물의 보수작업을 위한 수중코팅제의 부착 특성을 조사하기 위하여 실험적 연구를 수행하였다. 고려된 실험변수는 코팅제의 종류, 코팅대상 모재의 표면 거칠기, 도포 작업환경(육상 혹은 수중)으로 부착 강도는 Pull-off 방식으로 측정하였다. 코팅제의 부착 강도는 각 수중코팅제의 도포 작업 완료 24시간 후에 ASTM C1583 규정에 따라 측정하였다. 또한, 콘크리트 모재와 코팅제 간의 부착파괴 거동(코팅제, 계면, 콘크리트 모재)을 육안으로 관찰하였으며 측정된 부착 강도 수치에 근거하여 각 실험요인의 비교분석을 수행하였다. 실험결과, 수중에서 도포한 코팅제의 부착 강도가 육상의 경우에 비해 감소하는 경향을 보였으며 수중환경에서는 부착 강도에 미치는 모재 표면 거칠기의 영향이 육상의 경우에 비하여 미비하였다. 마지막으로 수중코팅제의 선정, 사용 시에 유의할 점에 대하여 설명하였다.

이형 GFRP 보강근의 기본정착길이에 대한 연구 (A Study on the Basic Development Length of GFRP Rebar With Ribs)

  • 문도영
    • 대한토목학회논문집
    • /
    • 제30권5A호
    • /
    • pp.485-493
    • /
    • 2010
  • 국내에서 개발된 이형 GFRP 보강근은 표면에 구축된 이형의 전단강도가 콘크리트의 전단강도 보다 상대적으로 작아 이형철근과 달리 이형 자체가 전단파괴되는 파괴모드를 보이는 것으로 확인된바 있다. 본 논문에서는 이형을 갖는 GFRP 보강근의 기본정착길이를 인발실험과 설계모델식과 해석적 엄밀식을 통해 고찰하였다. 실험결과, 동일조건하에서 파괴모드가 변화되는 임계정착길이가 이형철근은 직경의 15배, 이형 GFRP 보강근은 20배인 것으로 나타났다. 또한 실험결과를 ACI440.1R-03 설계모델식에 적용하여 분석한 결과, 충분한 횡구속이 수반된 경우 직경 9 mm의 이형 GFRP 보강근의 기본정착길이는 직경의 21배인 것으로 나타났다. 반면, ACI440.1R-06에 제시된 기본정착길이 모델은 실험결과에 비하여 너무 과대한 기본정착길이를 요구하는 것으로 나타났다. Cosenza 등(2002)의 모델은 실험결과에 비하여 더 적은 기본 정착길이를 요구하므로, 설계목적의 사용은 제한적인 것으로 판단되었다.

AC / PCC 복합포장 경계면 재료의 부착 성능 평가 (Evaluation of Bond Performance for AC overlay on PCC Pavement)

  • 김동규;황현식;;류성우;조윤호
    • 한국도로학회논문집
    • /
    • 제18권5호
    • /
    • pp.1-9
    • /
    • 2016
  • PURPOSES : This study focuses on the evaluation of interface performance with varying surface texture and tack coat application in an asphalt overlay. METHODS : The evaluation is carried out in two phases: tracking test and interface bond strength test. Using an image processing tool, tracking test is conducted to evaluate the susceptibility of the tack coat material to produce excessive tracking during application. Using the pull-off test method, the bond strength test is performed to determine the ability of the interface layer to resist failure. RESULTS : Results show that the underseal application yields less tracking compared to other applications. However, the bond strength is barely within the minimum acceptable value. On the other hand, RSC-4 produces higher bond strength for all surface types, but the drying time is long, which produces excessive tracking. CONCLUSIONS : While underseal application may be suitable for a trackless condition, the bond strength is less appealing compared to the rest of the tack applications available. RSC-4 demonstrated a high and consistent bond strength performance, but more time is required for drying to avoid excessive tracking. Tack coat application and surface type combination produce varying results. Therefore, these should be considered when selecting suitable future tack coat application options.

압입 시험에 의한 플라즈마 세라믹 용사코팅의 특성 평가 (Evaluation of the characteristics of plasma sprayed ceramic coatings by Indentation test)

  • 최세영;채영훈;김석삼
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.248-254
    • /
    • 2002
  • The most controversial topics in plasma sprayed ceramic coating system are recently mechanical properties such as bond strength, cohesive strength, toughness and so on. Determination of bond strength of coatings is one of the most important problems. In the industry, the bond strength of coating system has been estimated by Pull-off test(ASTM standard C633-79). But, without a fixed jig and specimen, it is impossible to obtain the bond strength. Therefore, it is necessary to study the critical fracture load on interface of the coating by indentation test. Because the critical fracture load plays an important role in evaluating the bond strength for plasma sprayed ceramic coating system. So, we have estimated critical fracture load in plasma sprayed ceramic coating system, and it was shown that inverse relationship between the cross-section hardness of coating and the critical fracture load(Pc). In case of the high load(1kgf, 2kgf) in $Al_{2}O_{3}+13%TiO_{2}$, it was found that the critical point(Pco), which the coating was broken on.

  • PDF

A Trade-Off between the Efficiency, Ripple and Volume of a DC-DC Converter

  • Taherbaneh, Mohsen;Rezaie, Amir H.;Ghafoorifard, Hasan;Mirsamadi, Maddad;Menh, Mohammad B.
    • Journal of Power Electronics
    • /
    • 제11권5호
    • /
    • pp.621-631
    • /
    • 2011
  • In space qualified DC-DC converters, optimization of the following electrical characteristics is of greater interest in comparison with other specifications; power loss/efficiency, output voltage ripple and volume/weight. The main goal of this paper is to present an appropriate solution for optimizing the above mentioned characteristics. For this purpose, a comprehensive power loss model of a DC-DC converter is fully developed. Proper models are also demonstrated for assessment of the output voltage ripple and the utilized transformer volume as the bulkiest component in a DC-DC converter. In order to provide a test bed for evaluation of the proposed models, a 50W push-pull DC-DC converter is designed and implemented. Finally, a novel cost function with three assigned weight functions is proposed in order to have a trade-off among the power loss, the output voltage ripple and the utilized transformer volume of the converter. The cost function is optimized for applications in which volume has the highest priority in comparison with power loss and ripple. The optimization results show that the transformer volume can be decreased by up to 51% and this result is verified by experimental results. The developed models and algorithms in this paper can be used for other DC-DC converter topologies with some minor modifications.

절삭방법에 따른 VES-LMC의 부착강도 특성 (Properties of VES-LMC Adhesive Strength for Surface Removal Methods)

  • 김기헌;정원경;이진범;이봉학;윤경구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.543-546
    • /
    • 2005
  • The development and maintenance of a sound bond are an essential requirements of concrete repair and replacement. The bond property of a bonded overlay to its substrate concrete during the lifetime is one of the most important performance requirements which should be quantified This study was performed to investigate the characteristics of adhesive strength for overlay concrete. Three different removal methods of deteriorated concrete such as chip-patch, mill-patch and water-jet were varied in this study. According to the adhesive strength of pull- off test, case III using water-jet was measured $2\~3$ times higher than that of chip-patch or mill-patch.

  • PDF

Effect of Surface Pretreatment on the Corrosion Resistance of Epoxy-Coated Carbon Steel

  • Lee, DongHo;Park, JinHwan;Shon, MinYoung
    • Corrosion Science and Technology
    • /
    • 제11권5호
    • /
    • pp.165-172
    • /
    • 2012
  • The corrosion resistance of epoxy-coated carbon steel was evaluated. The carbon steel surface was subjected to different treatment methods such as steel grit blasting with different size, steel shot ball blasting and power tool treatment. To study the effect of the treatments, the topology of the treated surface was observed by optical 3D microscopy and a pull-off adhesion test was conducted. The corrosion resistance of the epoxy-coated carbon steel was further examined by electrochemical impedance spectroscopy (EIS) combined with hygrothermal cyclic testing. The results of EIS indicated that the epoxy-coated carbon steel treated with steel grit blasting showed an improved corrosion resistance compared to untreated epoxy-coated surfaces or surfaces subjected to shot ball blasting and power tool treatments.