• 제목/요약/키워드: pull-in state

검색결과 96건 처리시간 0.025초

열가소성 폴리머 필름의 마이크로 점착 거동에 대한 온도의 영향 (Effect of Temperature on the Micro-scale Adhesion Behavior of Thermoplastic Polymer Film)

  • 김광섭;허정철;김경웅
    • Tribology and Lubricants
    • /
    • 제25권2호
    • /
    • pp.86-95
    • /
    • 2009
  • Adhesion tests were carried out in order to investigate the effect of temperature on the adhesion behavior between a PMMA film and a fused silica lens in the micro scale. For the tests, a microtribometer system was specially designed and constructed. The pull-off forces on the PMMA film were measured under atmospheric condition as the temperature of the PMMA film was increased from 300 K to 443 K and decreased to 300 K. The contact area between the PMMA film and the lens was observed during the test. The adhesion behavior was changed with the change of the PMMA surface state as the temperature increased. In glassy state below 363 K, the pull-off force did not change with the increase of temperature. In rubbery state from 383 K to 413 K, the pull-off force increased greatly as the temperature increased. In addition, the area of contact was enlarged. In viscous state above 423 K, the fingering instability was observed in the area of contact when the PMMA film contacted with the lens. It was also found that the adhesion behavior can be varied with the thermal history of the PMMA film. The residual solvent in the PMMA film could emerge to the PMMA surface due to the heating and reduced the pull-off force.

신뢰성이 개선된 새로운 푸쉬풀 컨버터 (A New Push-Pull Converter with Improved Reliability)

  • 정규범
    • 한국위성정보통신학회논문지
    • /
    • 제12권2호
    • /
    • pp.33-37
    • /
    • 2017
  • 본 논문에서는 새로운 신뢰성 있는 푸쉬풀 컨버터를 제안하였다. 제안된 컨버터는 기존의 푸쉬풀 컨버터에 비해 두 개의 다이오드가 추가된 구조를 갖는다. 이 추가된 다이오드로 인해서 푸쉬풀 컨버터의 두 개의 MOSFET 스위치 중에 한 개가 켜진 상태이면 다른 MOSFET는 자동으로 오프 상태를 유지한다. 그러므로 컨버터가 매우 큰 전기적인 노이즈 환경에 있더라도 두 개의 스위치가 켜지면서 회로가 단락되는 것을 막을 수 있다. 본 논문에서는 100 kHz의 스위칭 주파수를 갖는 컨버터를 노이즈 환경에서 PLECS 소프트웨어로 시뮬레이션하였다. 시뮬레이션 결과 컨버터 스위치의 전류는 $20{\mu}sec$의 전기적인 노이즈 환경에서 10 % 정도 증가한다. 그러나, 컨버터는 단락현상이 없이 신뢰성 있게 동작한다.

Pull-in과 release 전압차 감소용 돌기구조를 갖는 비틀림형 초소형 기계적 스위칭 소자 (Torsional Micromechanical Switching Element Including Bumps for Reducing the Voltage Difference Between Pull-in and Release)

  • 하종민;한승오;박정호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권9호
    • /
    • pp.471-475
    • /
    • 2001
  • ln this paper, a micromachined micromechanical switch is presented. The presented switch is operated in the vertical direction to the substrate by an electrostatic force between two parallel plates. The moving plate is pulled down to connect the bumps of the bias node$(V_{DD}/ or GND)$ to the bumps of the output node when a oltage difference exists between the moving plate and the input plate. The switch was designed to operate at a low switching voltage$(\risingdotseq5V)$ by including a large-area, narrow-gap, parallel plate capacitor A theoretical analysis of the designed switch was performed in order to determine its geometry fitting the desired pull-in voltage and release voltage. The designed switch was fabricated by surface micromachining combined with Ni electroplating. From the experimental results of the fabricated switch, its pull-in voltage came Out to be less than 5V and the measured maximum allowable current was 150mA. The measured average ON-state resistance was about 8$\Omega$, and the OFF-state resistance was too high to be measured with digital multimeter.

  • PDF

Experimental bond behavior of hybrid rods for concrete reinforcement

  • Nanni, Antonio;Nenninger, Jeremy S.;Ash, Kenneth D.;Liu, Judy
    • Structural Engineering and Mechanics
    • /
    • 제5권4호
    • /
    • pp.339-353
    • /
    • 1997
  • Fiber reinforced plastic (FRP) rods provide certain benefits over steel as concrete reinforcement, such as corrosion resistance, magnetic and electrical insulation, light weight, and high strength. FRP composites can be combined with a steel core to form hybrid reinforcing rods that take advantage of properties of both materials. The objective of this study was to characterize the bond behavior of hybrid FRP rods made with braided epoxy-impregnated aramid or poly-vinyl alcohol FRP skins. Eleven rod types were tested using two concrete strengths. Specific topics examined were bond strength, slip, and type of failure in concentric pull-out tests from concrete cubes. From analysis of identical pull-out tests on both hybrid and steel rods, information on relative bond strength and behavior were obtained. It is concluded that strength is similar but slip in hybrid rods is much higher. Hybrid rods failed either by pull-out or splitting the concrete block (with or without yielding of the steel core). Experimental data showed consistency with similar test results presented in the literature.

Pull-in 봉합술을 이용한 수지건 원위 부착부 파열의 치료 (Pull-in Suture Technique for the Disinsertion of the Phalangeal Tendon Distal Insertion)

  • 김재원;정성모
    • Archives of Plastic Surgery
    • /
    • 제35권6호
    • /
    • pp.723-728
    • /
    • 2008
  • Purpose: The disinsertion of the phalangeal tendon distal insertion has difficulties in ordinary tenorrhaphy operation for the anatomical features, and still has controversy between non-surgical and surgical management. The purpose of this study is to select treatment for the injury of the phalangeal tendon distal insertion, as we've had a good results from operation treatment with Pull-in suture technique. Methods: We reviewed the hospital records of 12 patients treated with Pull-in suture technique with disinsertion of the phalangeal extensor or flexor tendon distal insertion from June 2006 to June 2007. Eight patients were involved with the tendon disinsertion without bone fracture, and 4 patients were involved with the fracture of the phalangeal tendon distal insertion site. After removal of the K-wire in week 6, active physical exercises were commenced immediately. The mean follow-up period was 12.4 months. Results: All the patients who had tendon disinsertion with bone fracture had IIB, by Wehbe and Schneider's classification 2, and we evaluated the results comparing the same finger of the other hand according to Crawford's evaluation criteria 5. The nine excellent and three good results were obtained and there were no limitation of motor for the patient who had operation for the rupture of flexor tendon as well. There were no particular complications during the follow-up period. Conclusion: The most important thing for the disinsertion of the phalangeal tendon distal insertion is to maintain an accurate and durable reduction state keeping the tension of tendon. At this point, after removal of the K-wire, the Pull-in suture technique allows accurate realignment of the tendon-bone unit without any specific instrumentation under the more stable state. The Pull-in suture technique seems to be a strong alternative for the treatment of disinsertion of the phalangeal tendon distal insertion, with successful treatment outcome(rapid functional recovery and high patient satisfaction).

센서 네트워크 기반의 Pull 및 Push 서비스 연구 (A Study of Pull and Push Service Based on Sensor Networks)

  • 김규리;김도현;변영철
    • 한국산학기술학회논문지
    • /
    • 제9권5호
    • /
    • pp.1289-1295
    • /
    • 2008
  • 최근에 다양한 유비쿼터스 서비스는 Push와 Pull 서비스 형태로 제공되고 있으며, 이와 같은 Pull/push 서비스를 제공하기 위한 OpenAPI(Application Program Interface)에 대한 연구가 진행되고 있다. 하지만 아직 Push와 Pull 서비스와 이를 지원하기 위한 OpenAPI에 대한 연구가 아직 미비하다. 이에 본 논문에서는 Pull 서비스와 Push 서비스를 이용하여 센서 네트워크 기반의 응용 인터페이스를 제공하는 Push 서비스와 Pull 서비스 모델을 제시하고, Push 서비스와 Pull 서비스를 제공하는 OpenAPI를 설계하고 구현한다. 이를 위하여 웹 서비스 기반의 Pull 서비스 구조를 제시하고, .Net 프레임워크 기반의 원격 서비스(Remote Service)를 이용하여 센서 네트워크에 수집된 온도, 습도 등의 상황 데이터를 Pull 서비스 형태로 제공하는 OpenAPI를 설계하고 구현한다. 더불어 TCP/IP 소켓 인터페이스를 이용한 Push 서비스 구조를 제안하고, 이 서비스를 제공하는 OpenAPI를 설계하고 구현한다. 이를 통해서 기존의 특정 데이터베이스 중심의 센서 네트워크의 폐쇄적인 응용 인터페이스를 개방적인 표준 인터페이스로 전환하여 사용자가 여러 곳에 널려 있는 많은 상황 데이터를 쉽게 접근하여 확인할 것으로 기대한다.

정상 상태 롤링 해석 기법 적용을 통한 타이어 패턴 형상에 따른 PRAT 특성 연구 (The Study on PRAT Performance due to Tire Pattern Shapes using Steady State Rolling Analysis Method)

  • 성기득;박현만;구병국;조춘택
    • 한국자동차공학회논문집
    • /
    • 제16권5호
    • /
    • pp.15-21
    • /
    • 2008
  • It is generally known that the PRAT(Plysteer Residual Aligning Torque) is one of indicating a performance factors of a tire for assessing the vehicle pull, also tire pattern shape, which means lateral groove angle, is very important tire design factor in relation to the PRAT. Lateral grooves of tire pattern are widely divided into center and shoulder parts. So, this paper has studied the correlation between the PRAT and their lateral groove angles using FEM. Especially, the steady state rolling analysis among tire rolling analysis methods has been used for the PRAT performance study. Firstly, analysis result data have been compared with the experimental data to validate FE analysis for PRAT. Next, the PRAT due to the lateral groove angle about PCR(Passenger Car Radial) tire and SUV tire has been analyzed. The tendency of the PRAT due to the lateral groove angles can be used as a guide line for the tire design in relation to vehicle pull.

병렬 VOD 시스템에서 서비스 모델의 성능분석 (Performance Analysis of Service Model in Parallel VOD system)

  • 남정임;남지승
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.1105-1108
    • /
    • 2005
  • Media service model is divided into 3 models that are Client Pull, Server Push, and IPP(Interleaving Pull & Push) model. In most single VOD(Video On Demand) environment, Client Pull model was sufficient to play the movie Because most media contents has a low bitrate and resolution. But according to an increment of the demand of the high definition media, Client Pull model is not sufficient. Parallel VOD environment is made of several of VOD servers and provides the parallel media stream simultaneously for one client. We compared and analyzed the performance of service models with respect to network delay and data size in buffer in the single and parallel VOD environment and we found that IPP service model keeps the least network delay and stable client buffer state in the parallel VOD environment.

  • PDF

Nucleocapsid Amino Acids 211 to 254, in Particular, Tetrad Glutamines, are Essential for the Interaction Between the Nucleocapsid and Membrane Proteins of SARS-Associated Coronavirus

  • Fang, Xiaonan;Ye, Lin-Bai;Zhang, Yijuan;Li, Baozong;Li, Shanshan;Kong, Lingbao;Wang, Yuhua;Zheng, Hong;Wang, Wei;Wu, Zhenghui
    • Journal of Microbiology
    • /
    • 제44권5호
    • /
    • pp.577-580
    • /
    • 2006
  • GST pull-down assays were used to characterize the SARS-CoV membrane (M) and nucleocapsid (N) interaction, and it was found that the amino acids 211-254 of N protein were essential for this interaction. When tetrad glutamines (Q) were replaced with glutamic acids (E) at positions of 240-243 of the N protein, the interaction was disrupted.

Design and Realization of a Digital PV Simulator with a Push-Pull Forward Circuit

  • Zhang, Jike;Wang, Shengtie;Wang, Zhihe;Tian, Lixin
    • Journal of Power Electronics
    • /
    • 제14권3호
    • /
    • pp.444-457
    • /
    • 2014
  • This paper presents the design and realization of a digital PV simulator with a Push-Pull Forward (PPF) circuit based on the principle of modular hardware and configurable software. A PPF circuit is chosen as the main circuit to restrain the magnetic biasing of the core for a DC-DC converter and to reduce the spike of the turn-off voltage across every switch. Control and I/O interface based on a personal computer (PC) and multifunction data acquisition card, can conveniently achieve the data acquisition and configuration of the control algorithm and interface due to the abundant software resources of computers. In addition, the control program developed in Matlab/Simulink can conveniently construct and adjust both the models and parameters. It can also run in real-time under the external mode of Simulink by loading the modules of the Real-Time Windows Target. The mathematic models of the Push-Pull Forward circuit and the digital PV simulator are established in this paper by the state-space averaging method. The pole-zero cancellation technique is employed and then its controller parameters are systematically designed based on the performance analysis of the root loci of the closed current loop with $k_i$ and $R_L$ as variables. A fuzzy PI controller based on the Takagi-Sugeno fuzzy model is applied to regulate the controller parameters self-adaptively according to the change of $R_L$ and the operating point of the PV simulator to match the controller parameters with $R_L$. The stationary and dynamic performances of the PV simulator are tested by experiments, and the experimental results show that the PV simulator has the merits of a wide effective working range, high steady-state accuracy and good dynamic performances.