• Title/Summary/Keyword: pull test

Search Result 582, Processing Time 0.027 seconds

Effects of Ar+ ion Beam Irradiation on the Adhesion Forces between Carbon fibers and Thermosetting Resins (Ar+ 이온 빔 조사가 탄소섬유와 열경화성 수지 간 계면결합력에 미치는 영향)

  • 박수진;서민강;김학용;이경엽
    • Polymer(Korea)
    • /
    • v.26 no.6
    • /
    • pp.718-727
    • /
    • 2002
  • In this work, an Ar+ beam was irradiated on carbon fiber surfaces to improve the interfacial shear strength (IFSS) of the resulting composites using an ion assisted reaction (IAR) method h single fiber pull-out test was executed to investigate the basic characteristics of the single Carbon fiber/matrix interface. Based on Greszczuk's geometrical model, the debonding force for pull-out of the fiber from the resins was discussed with the applied ion beam energy as a result, it was known that an ion beam treatment produced the functional groups on fiber surface and etching lines along the fiber axis direction, resulting in increasing the adhesion forces between fibers and matrix, which caused the improvement of the IFSS in a composite system. And, it was also found that the maximum IFSS was shown at 0.8 keV ion beam energy in this system.

A Study on the Behavioral Characteristics of a Circular Foundation Dominated by Pull-Out Load through Field Test (현장시험을 통한 인발하중이 지배적인 원형기초의 거동 특성 연구)

  • Shin, Kyung-Ha;Lee, Seung-Ho;Lee, Dong-hyuk;Park, Du-hee
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.4
    • /
    • pp.53-62
    • /
    • 2021
  • For the rational application of LRFD, which is actively applied in Korea, for the study of the pull-out load and the horizontal load, which are insufficient examples, a circular foundation based on the transmission tower foundation, which is a socially important structure, through field tests in single and mixed layer. Factors that can affect the design were studied by analyzing the resistance of each stratum to pull-out and horizontal loads.

Study on Prediction of Net Thrust of Multi-Pod-Driven Ice-Breaking Vessel Under Bollard Pull and Overload Conditions According to the Change of Water Depth Using Computational Fluid Dynamics-Based Simulations (수심 변화에 따른 볼라드 당김 및 과부하 조건에서의 다중 포드 추진 쇄빙선박의 여유추력 추정에 대한 수치해석적 연구)

  • Kim, JinKyu;Kim, Hyoung-Tae;Kim, Hee-Taek;Lee, Hee-Dong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.3
    • /
    • pp.158-166
    • /
    • 2021
  • In this paper, a numerical analysis technique using a body force model is investigated to estimate the available net thrust of multi-pod-driven ice-breaking vessels under bollard pull and overload conditions. To employ the body force model in present flow simulations, drag and thrust components acting on the pod unit are calculated by using Propeller Open Water (POW) test data. The available net thrusts according to the direction of operation are evaluated in both bollard pull and overload conditions under deep water. The simulation results are compared with the model test data. The available net thrusts, calculated by the present analysis for ahead operating modes at 3~6 knots which are typical speeds of the target vessel in arctic field, are agreed well with the model test results. It is also found that the present result for astern operating mode appears approximately 6 % larger than the model test result. In addition, the available net thrusts are calculated under the both operating conditions accompanied by shallow water effects, and the main cause of the difference is studied. Based on the result of the present study, it is confirmed that the body force model can be applied to the performance evaluation of multi-pod propulsion system and the main engine selection in early design stage of the vessel.

Characteristics Analysis and Test of a Voice-Coil-Type LOA Considering the Push/pull Effects (Push/Pull Effect를 고려한 보이스코일형 LOA의 특성해석 및 시험)

  • Jang, S.M.;Jeong, S.S.;Park, H.C.;Moon, S.J.;Park, C.I.;Chung, T.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.275-277
    • /
    • 1998
  • The effect of the coil flux, so called "push/pull effect", is to shift the airgap flux density variation due to the magnet alone by a certain amount. Thrust therefore is shift downward or upward. The push/pull effect was presented through the FEM analysis and static tests. We compared with the thrust obtained through the FEM analysis and static tests.

  • PDF

Testing and Numerical Analysis Techniques for Pull-out Resistance Characteristics of the Extensible Geogrid (신장성 지오그리드 보강재의 인발저항특성 평가를 위한 시험 및 수치해석 기법)

  • 이성혁;고태훈;이진욱;황선근
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.2
    • /
    • pp.93-103
    • /
    • 2002
  • Reinforced earth structure has been regarded as general structure in order to achieve efficient land utilization as well as securing safety in railway service lines in other countries, but there are no construction actual results in Korea. In this study, the soil-geogrid interaction mechanism was investigated experimentally and numerical analysis was performed to predict Pull-out behaviour of geogrid embedded in reinforced earth body. This experimental data and analysis result can not contribute to understand the soil-geogrid interaction mechanism at soil-geogrid interface but also be used in design practice of the railway reinforced earth structures.

Support Characteristics of Rock Bolt and Spiral Bolt (록 볼트 및 스파이럴 볼트의 지보특성)

  • Cho, Young-Dong;Song, Myung-Kyu;Lee, Chung-Shin;Kang, Choo-Won;Ko, Jin-Seok;Kang, Seong-Seung
    • Tunnel and Underground Space
    • /
    • v.19 no.3
    • /
    • pp.181-189
    • /
    • 2009
  • This study is to evaluate an effect of supports with respect to these supports after comparing the characteristic of support between rock bolt of a widely used type and spiral bolt of a new type. For these purposes, we performed pull-out test in laboratory about rock and spiral bolts in the case of cement-mortar grout curing periods, 7 and 28 days, then calculated pull-out load, displacement, external pressure, inner pressure and shear stress using data obtained from the results of pull-out test, respectively. In relation between pull-out load and displacement, displacement of spiral bolt is larger than one of rock bolt. It is considered that mechanical property of rock bolt is due to larger than one of spiral bolt. In addition, displacement of supports shows nearly same or decreasing with curing periods. We found that because adhesive force between supports and cement-mortar grout is increasing with compressive strength of grout according to curing periods. The inner pressure of spiral bolt is represented larger than one of rock bolt at a step of same pull-out load. It is suggested that spiral bolt is more stable than rock bolt, maintaining stability of ground or rock mass, when supports are installed in a ground or rock mass under the same condition. Putting together with above results, we can consider that spiral bolt as a new support on an aspect of pull-out load and inner pressure is larger than rock bolt in a ground or rock mass under the same condition. Moreover, spiral bolt is more effective support than rock bolt, considering an economical and constructive aspects of supports, as well as ground or rock stability before or after installing supports.

How do Physical Stores Survive in the Market: An Investigation into Consumer Switching Behavior from the Online to the Offline Channel (물리적 매장이 시장에서 살아남는 방법: 소비자의 온라인 채널에서 오프라인 채널로의 전환행동에 관한 연구)

  • Duan, Xiaowei;Zong, Lu
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.1
    • /
    • pp.224-239
    • /
    • 2022
  • Despite an impressive growth of online sales, the bricks-and-mortar bandwagon still remain high-profile in the realm of consumer channel switching behavior. Different from the existing research exploring the consumer switching behavior from the offline to the online retailer, this study is an effort to investigate why and when do consumers switch from the online to the offline channel by applying the push-pull-mooring framework. Thus, structural equation modeling and SPSS were used to test the established hypotheses. The results, as expected, show that both push factors (i.e., perceived risk and dissatisfaction) and pull factors (alternative attractiveness and perceived ownership) are positively related to a consumer's intention to switch from the online to the offline channel. Moreover, all of expected interactions between push factors and mooring factors (i.e., switching costs, variety seeking, and subjective norms), and between pull factors and mooring factors are supported, except for the interactions between push factors and switching costs as well as between pull factors and subjective norms. Finally, implications and limitations are discussed.

Experimental Study for Optimal Method in Measuring the Basic Friction Angle of Rock (최적의 기본마찰각 측정법에 관한 실험적 연구)

  • Lee, Kook-Hyun;Jang, Hyun-Sic;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.565-578
    • /
    • 2019
  • Basic friction angles of Hwangdeung granite, Berea sandstone, Jeongsun marble, Hongcheon gneiss, Pungam shale and Eumseong sandy shale were measured by direct shear test, tilt test and pull test. Characteristics of basic friction angle and the accuracy of test methods were compared and the optimal method in measuring basic friction angle was suggested. Although basic friction angles might be measured accurately by direct shear test, the test apparatus is expensive and procedures are complicated. Tilt tests which is the suggested method for measuring basic friction angle by International Association for Rock Mechanics also provided similar basic friction angles measured by direct shear test. However, the error measured for the same rock type is higher than 7° and values by repeated measurements in one sample show different trends, such as increasing or decreasing or almost constant as measurements continued. The difference measured in one gneiss sample is higher 12°, indicating that tilt test may be not a reliable method for measuring basic friction angle. Not only pull test provided accurate and consistent results under low normal stresses, but also test apparatus is simple and inexpensive and procedure is not complicated, indicating that pull test may be the optimal method for measuring basic friction angle.

Experimental and analytical behaviour of composite slabs

  • Lopes, Emanuel;Simoes, Rui
    • Steel and Composite Structures
    • /
    • v.8 no.5
    • /
    • pp.361-388
    • /
    • 2008
  • The Eurocode 4 presents some negative aspects in the design of composite slabs by the m-k Method or the Partial Connection Method. On one hand, the component chemical adherence is not accounted for in the connection between the profiled steel sheet and the concrete. On the other hand, the application of these methods requires some fitting parameters that must be determined by full scale tests. In this paper, the Eurocode 4 methods are compared with a method developed at the Federal Polytechnic School of Lausanne, based on pullout tests, which can be a valid alternative. Hence, in order to calculate the necessary parameters for the three methods, several tests have been performed such as the full scale test described in Eurocode 4 and pull-out tests. This last type of tests is of small dimensions and implicates lower costs. Finally, a full-scale test of a steel-concrete composite slab with a generic loading is presented, with the goal of verifying the analytical formulation.

Study on the Impact Analysis of Front Loader for Tractor (트랙터용 프론트 로더의 충격해석에 관한 연구)

  • Lim, Gi-Soo;Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5051-5059
    • /
    • 2015
  • Structural behaviour of the front loader for an agricultural tractor was analyzed for three impact test conditions: drop and catch, corner pull, and corner push. Rigid-body dynamic, transient structural, and static structural analyses were conducted using a commercial finite element software. Analysis of the drop and catch test dealt with the case that the bucket located at the maximum elevation was dropped and catched through three steps. Analysis of the corner pull test dealt with the case that the bucket constrained to the ground by a chain at its corner was raised suddenly. Analysis of the corner push test dealt with the case that the corner of the bucket collided with an obstacle. Results of analyses of the three test conditions showed that maximum stress occurs at the geometrically discontinuous location in the mount and is caused from local stress concentration. Results of the present research can be utilized as a guideline to achieve more reliable and safe structural design of the front loaders.