• Title/Summary/Keyword: pull

Search Result 2,043, Processing Time 0.027 seconds

Design of 1-Kb eFuse OTP Memory IP with Reliability Considered

  • Kim, Jeong-Ho;Kim, Du-Hwi;Jin, Liyan;Ha, Pan-Bong;Kim, Young-Hee
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.11 no.2
    • /
    • pp.88-94
    • /
    • 2011
  • In this paper, we design a 1-kb OTP (Onetime programmable) memory IP in consideration of BCD process based EM (Electro-migration) and resistance variations of eFuse. We propose a method of precharging BL to VSS before activation of RWL (Read word-line) and an optimized design of read NMOS transistor to reduce read current through a non-programmed cell. Also, we propose a sensing margin test circuit with a variable pull-up load out of consideration for resistance variations of programmed eFuse. Peak current through the non-programmed eFuse is reduced from 728 ${\mu}A$ to 61 ${\mu}A$ when a simulation is done in the read mode. Furthermore, BL (Bit-line) sensing is possible even if sensed resistance of eFuse has fallen by about 9 $k{\Omega}$ in a wafer read test through a variable pull-up load resistance of BL S/A (Sense amplifier).

Spatially Combined V-Band MMIC Coupled Oscillator Array in Waveguide (도파관 내에서 공간적으로 결합된 V-Band MMIC 결합 발진기 Array)

  • 최우열;김홍득;강경태;임정화;권영우
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.8
    • /
    • pp.783-789
    • /
    • 2002
  • In this paper, V-band MMIC coupled oscillator arrays are presented. In the proposed array, two push-pull patch antennas are synchronized by using strong electromagnetic coupling between two antennas. As a result, total size of the array is reduced and the array can be integrated in a single chip. To verify proposed array concept, two 1$\times$2 arrays are designed and fabricated using standard 0.15 um gate length pHEMT MMIC process. The circuits are mounted in an oversized waveguide and measured. The first array shows 0.5 dBm at 56.372 GHz and the second one has an output of 5.85 dBm at 60.147 GHz.

A Current-Fed Parallel Resonant Push-Pull Inverter with a New Cascaded Coil Flux Control for Induction Heating Applications

  • Namadmalan, Alireza;Moghani, Javad Shokrollahi;Milimonfare, Jafar
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.632-638
    • /
    • 2011
  • This paper presents a cascaded coil flux control based on a Current Source Parallel Resonant Push-Pull Inverter (CSPRPI) for Induction Heating (IH) applications. The most important problems associated with current source parallel resonant inverters are start-up problems and the variable response of IH systems under load variations. This paper proposes a simple cascaded control method to increase an IH system's robustness to load variations. The proposed IH has been analyzed in both the steady state and the transient state. Based on this method, the resonant frequency is tracked using Phase Locked Loop (PLL) circuits using a Multiplier Phase Detector (MPD) to achieve ZVS under the transient condition. A laboratory prototype was built with an operating frequency of 57-59 kHz and a rated power of 300 W. Simulation and experimental results verify the validity of the proposed power control method and the PLL dynamics.

The Effect of Transformer Leakage Inductance on the Steady State Performance of Push-pull based Converter with Continuous Current

  • Chen, Qian;Zheng, Trillion Q.;Li, Yan;Shao, Tiancong
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.349-361
    • /
    • 2013
  • As a result of the advantages such as high efficiency, continuous current and high stability margin, push-pull converter with continuous current (PPCWCC) is competitive for battery discharge regulator (BDR) which plays an important role in power conditioning unit (PCU). Leakage inductance yields current spike in low-ripple current of PPCWCCs. The operating modes are added due to leakage inductance. Therefore the steady state performance is affected, which is embodied in the spike of low-ripple current. PPCWCCs which are suitable for BDR can be separated into three types by current spike characteristics. Three representative topologies IIs1, IIcb2 and Is3 are analyzed in order to investigate the factors on the magnitude and duration of spike. Equivalent current sampling method (ECSM) which eliminates the sampling time delay and achieves excellent dynamic performance is adopted to prevent the spike disturbance on current sampling. However, ECSM reduces the sampling accuracy and telemetry accuracy due to neglecting the spike. In this paper, ECSM used in PPCWCCs is summarized. The current sampling error is analyzed in quality and quantity, which provides the foundation for offsetting and enhancing the telemetry accuracy. Finally, current sampling error rate of three topologies is compared by experiment results, which verify the theoretical analysis.

An Antenna-Integrated Oscillator Design Providing Convenient Control over the Operating Frequency and Output Power (동작주파수 및 출력파워 조절이 용이한 신호생성용 안테나 설계)

  • Lee, Dong-Ho;Lee, Jong-In;Kim, Mun-Il
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.1
    • /
    • pp.54-58
    • /
    • 2006
  • A new design for easily controlling operating frequency of an antenna-integrated planar oscillator is introduced. The oscillator circuit of a broadband negative-resistance active part and a passive load including a patch antenna. The patch resonance is used for determining the oscillation frequency. This design reduces the possibility of mismatch between antenna radiation and oscillation frequencies. To achieve optimum output power, load-pull simulation for the negative-resistance circuit is used. The load-pull simulation shows the feed point and the delay of feed line can affect the oscillation power. Two negative-resistance circuits capable of supporting oscillation over full C-band and X-band are fabricated. The oscillation frequency, output power and phase noise for different patch antennas are measured.

  • PDF

Modeling and controller design of crabbing motion for auto-berthing (선박 자동접안을 위한 순수 횡 이동 모델링 및 제어기 설계)

  • Park, Jong-Yong;Kim, Nakwan
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.56-64
    • /
    • 2013
  • Crabbing motion is the pure sway motion of a ship without surge velocity. Thus, it can be applied to a berthing operation. Crabbing motion is induced by a peculiar operation method called the push-pull mode. The push-pull mode is induced by using a combination of the main propeller and side thruster. Two propellers generating the same amounts of thrust and rotating in opposite directions produce some yawing moment on a vessel but do not induce longitudinal motion. With the additional operation of side thrusters, the push-pull mode is used to induce a large amount of lateral force. In this paper, three-degree-of-freedom equations of motion such as for the surge, sway, and yaw are constructed for the crabbing motion. Based on these equations of motion, a feedback linearization control method is applied to auto-berthing control for a twin-screw ship with side thrusters. The controller can deal with the nonlinearity of a system, which is present in the berthing maneuver of a twin screw ship. A simulation of the auto-berthing of a ship is performed to validate the performance of the designed controller.

Application of single-well push-drift-pull tests using dual tracers (SF6 and salt) for designing CO2 leakage monitoring network at the environmental impact test site in Korea

  • Kim, Hong-Hyun;Lee, Seong-Sun;Ha, Seung-Wook;Lee, Kang-Kun
    • Geosciences Journal
    • /
    • v.22 no.6
    • /
    • pp.1041-1052
    • /
    • 2018
  • A single-well push-drift-pull tracer test using two different tracers ($SF_6$ and salt) was performed at the Environmental Impact Test (EIT) site to determine suitable locations for monitoring wells and arrange them prior to artificial $CO_2$ injection and leak tests. Local-scale estimates of hydraulic properties (linear groundwater velocity and effective porosity) were obtained at the study site by the tracer test with two tracers. The mass recovery percentage of the volatile tracer ($SF_6$) was lower than that of the non-volatile tracer (salt) and increased drift time may make degassing of $SF_6$ intensified. The $CO_2$ leakage monitoring results for both unsaturated and saturated zones suggest that the $CO_2$ monitoring points should be located near points at which a high concentration gradient is expected. Based on the estimated hydraulic properties and tracer mass recovery rates, an optimal $CO_2$ monitoring network including boreholes for monitoring the unsaturated zone was constructed at the study site.

A Study On D-Shortage Control Hyper System Using MRP and JIT (MRP와 JIT를 융합한 D-결품관리 시스템에 관한 연구)

  • 조동수;이근희
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.15 no.25
    • /
    • pp.63-74
    • /
    • 1992
  • This study proposes D- shortage control system which is a convenient tool for cooperative companies to reduce shortages which frequently break out between the manufacturing companies and the cooperative companies. On the ground of theoretical analysis of MRP and JIT system, D- shortage control system sets up a schedule that secures the delivery date by precedent scheduling( D-) comparing with MRP It also syncronizes business, production and release, and builds the pull system comparing with JIT. The factors causing shotages are the scheduling absurdity and the controlling absurdity. The scheduling absurdity can be settled by the calculating required quantity method of MRP and the controlling absurdity can be settled by daily control of business, production and pruchasing fuctions by the pull system of JIT. And the inventory and the WIP can be reduced by the operating of PULL system and by the settlement of D- shortage control practices. The Application of D- shortage control system, therefore, enables the rationalization of logistics and reduces the inventory And it leads to the reinforced competitiveness and the security of subsistence of manufacturer by the cost ruduction, the reduction of financial difficulty, and the insurance of the delivery date.

  • PDF

Response of square anchor plates embedded in reinforced soft clay subjected to cyclic loading

  • Biradar, Jagdish;Banerjee, Subhadeep;Shankar, Ravi;Ghosh, Poulami;Mukherjee, Sibapriya;Fatahi, Behzad
    • Geomechanics and Engineering
    • /
    • v.17 no.2
    • /
    • pp.165-173
    • /
    • 2019
  • Plate anchors are generally used for structures like transmission towers, mooring systems etc. where the uplift and lateral forces are expected to be predominant. The capacity of anchor plate can be increased by the use of geosynthetics without altering the size of plates. Numerical simulations have been carried out on three different sizes of square anchor plates. A single layer geosynthetic has been used as reinforcement in the analysis and placed at three different positions from the plate. The effects of various parameters like embedment ratio, position of reinforcement, width of reinforcement, frequency and loading amplitude on the pull out capacity have been presented in this study. The load-displacement behaviour of anchors for various embedment ratios with and without reinforcement has been also observed. The pull out load, corresponding to a displacement equal to each of the considered maximum amplitudes of a given frequency, has been expressed in terms of a dimensionless breakout factor. The pull out load for all anchors has been found to increase by more than 100% with embedment ratio varying from 1 to 6. Finally a semi empirical formulation for breakout factor for square anchors in reinforced soil has also been proposed by carrying out regression analysis on the data obtained from numerical simulations.

Gracilis pull-through flap for the repair of a recalcitrant recto-vaginal fistula

  • Mok, Wan Loong James;Goh, Ming Hui;Tang, Choong Leong;Tan, Bien Keem
    • Archives of Plastic Surgery
    • /
    • v.46 no.3
    • /
    • pp.277-281
    • /
    • 2019
  • Recto-vaginal fistulas are difficult to treat due to their high recurrence rate. Currently, no single surgical intervention is universally regarded as the best treatment option for recto-vaginal fistulas. We present a case of recurrent recto-vaginal fistula surgically treated with a gracilis pull-through flap. The surgical goals in this patient were complete excision of the recto-vaginal fistula and introduction of fresh, vascularized muscle to seal the fistula. A defunctioning colostomy was performed 1 month prior to the present procedure. The gracilis muscle and tendon were mobilized, pulled through the freshened recto-vaginal fistula, passed through the anus, and anchored externally. Excess muscle and tendon were trimmed 1 week after the procedure. Follow-up at 4 weeks demonstrated complete mucosal coverage over an intact gracilis muscle, and no leakage. At 8 weeks post-procedure, the patient resumed sexual intercourse with no dyspareunia. At 6 months post-procedure, her stoma was closed. The patient reported transient fecal staining of her vagina after stoma reversal, which resolved with conservative treatment. The fistula had not recurred at 20 months post-procedure. The gracilis pull-through flap is a reliable technique for a scarred vagina with an attenuated recto-vaginal septum. It can function as a well-vascularized tissue plug to promote healing.