Development of an Electronic Starter for Fluorescent Lamps (형광램프용 전자식 스타터의 개발)

  • 정영춘;곽재영;여인선
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.49-52
    • /
    • 1996
  • This paper reports the development of an electronic starter for fluorescent lamps, which is so smartly designed that can be used directly in existing installations. The key point of the design lies in the protection of lamp filaments by sufficient preheating and at the same time in the control of time constant for start-up circuit. The starter is consisted of three system parts: a rectifier pact, a switching part. and a gate control part. The characteristics of the developed electronic starter is compared with those of a conventional glow starter. As a result, blackening of lamps is almost reduced due to the stable and idealized start-up characteristics. And, furthermore, it is shown that its slaving time is shortened at about half the level of the conventional one and the starting power is also reduced.

  • PDF

Voltage Time characteristic of electrical breakdown in $SF_6$ ($SF_6$ 가스중 V-t절연파괴특성)

  • Seo, Kil-Soo;Kim, Ik-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1770-1772
    • /
    • 1997
  • In this paper, Voltage-time characteristics of lightning impulse and switching surge breakdown in SF6 is studied on the gap and various pressure. The characteristics is categorized into three pattern depending on the configuration of the gap and gas pressure. The properties of the voltage-time characteristics in these patterns are generalized as semi-empirical formula which will be useful in the quantitation voltage evaluation of insulation coordination and the abnormal voltage protection of SF6 insulated power equipment.

  • PDF

Identification of Inrush and Internal Fault in Indirect Symmetrical Phase Shift Transformer Using Wavelet Transform

  • Bhasker, Shailendra Kumar;Tripathy, Manoj;Kumar, Vishal
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1697-1708
    • /
    • 2017
  • This paper proposes an algorithm for the differential protection of an Indirect Symmetrical Phase Shift Transformer (ISPST) by considering the different behaviors of the compensated differential current under internal fault and magnetizing inrush conditions. In this algorithm, a criterion function is defined which is based on the difference of amplitude of the wavelet transformation over a specific frequency band. The function has been used for the discrimination between three phase magnetizing inrush and internal fault condition and requires less than a quarter cycle after disturbance. This method is independent of any coefficient or threshold values of wavelet transformation. The merit of this algorithm is demonstrated by the simulation of different faults in series and excitation unit and magnetizing inrush with varying switching conditions on ISPST using PSCAD/EMTDC. Due to unavailability of in-field large interconnected transformers for such a large number of destructive tests, the results are further verified by Real Time Digital Simulator (RSCAD/RTDS). The proposed algorithm has been compared with the conventional harmonic restraint based method that justifies the application of wavelet transform for differential protection of ISPST. The proposed algorithm has also been verified for different rating of ISPSTs and satisfactory results were obtained.

Performance of Fault-tolerant Ethernet System with Link-bypass scheme for Airbone Databus (항공 데이터버스용 링크 우회방식을 가진 고장감내 이더넷 시스템의 성능 분석)

  • Song, Dae-Yoen;Yoon, Chong-Ho;Jung, Han-Gyun;Kim, Seung-Hwan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.9
    • /
    • pp.46-53
    • /
    • 2007
  • The link-fault recovery in the normal Ethernet bridged networks has relied on the Spanning Tree Protocol(STP) or Rapid STP. However, STP can not offer fast error recovery which is needed real-time services such as aircraft. In this paper, we compare automatic protection switching(APS) providing fault-tolerant function in the BcN back bone system with Avionic Full Duplex Switched Ethernet(AFDX) which is recently equipped in the A380 for Airbone Databuses. Also, we propose a link-bypass scheme for improving fault-tolerant performance of the AFDX by connecting switches and bypass fault section when a fault is originated on the link. For comparing and verifying the performance of proposed scheme, we simulated Ethernet, AFDX, APS and proposed AFDX with link-bypass scheme using NS-2. The proposed AFDX with link-bypass scheme can be applied to aircrafts, BcN backbone networks and industrial automatic networks.

The study on the development of intelligent optical communication system to monitor flood and water pollution (홍수 및 수질 오염 감시용 지능형 고속 광 통신 시스템 개발에 관한 연구)

  • Lee, Jin-Young
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.351-358
    • /
    • 2012
  • This study is aimed at suggesting optical communication equipment that can deliver high quality video information in high speed, to efficiently handle the flood and water pollution in the river basin. This system is cheaper than existing equipment, and can monitor optical Internet as well as the condition of equipment. Generally, the communication equipment to prevent flood is installed in an unmanned control box and operated by the flood control office situated at the fiver mouth in a long distance section. Therefore, it is hard to promptly cope with communication interruptions, which occur by the cutting or aging of the optical cable. Under the circumstances, this study suggested an efficient system that can deliver high quality video information in high speed (Optical Transmission Convert System) by using optical fiber. The system also solves problems by making use of automatic protection switching (APS) when an accident happens. Its real-time monitoring function gives notice of the problem-occurring points. The system is expected to be widely used in various areas such as intelligent traffic systems.

A Study on The Development and Function Test of Digital Transformer Protection Relay Using The Induced Voltage (유기전압비를 이용한 디지털형 변압기 보호계전기 개발 및 성능시험에 관한 연구)

  • Jung, Sung-Kyo;Lee, Jae-Kyung;Kim, Han-Do;Choi, Dae-Gil;Kang, Yong-Chul;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.216-218
    • /
    • 2001
  • The transformer role is very important in power system operation and control; also its price is very expensive. Therefore many kinds of the efforts for transformer protection have been executed. So for as, current differential relay(87) has been mainly used for transformer protection. But current differential relaying method has several troubles as followings. Differential current can be occurred by transformers inrush current between winding1 and winding2 of transformer when transformer is initially energized. Also harmonic restrained element used in current differential relaying method is one of the causes of relays mal-operation because recently harmonics in power system gradually increase by power switching devices(SVC, FACTS, DSC, etc). Therefore many kinds of effort have been executed to solve the trouble of current differential relay and one of them is method using ratio of increment of flux linkages(RIFL) of the primary and secondary windings. This paper introduces a novel protective relay for power transformers using RIFL of the primary and secondary windings. Novel protective relay successfully discriminates between transformer internal faults and normal operation conditions including inrush and this paper includes real time test results using RTDS(Real Time Digital Simulator) for novel protective relay. A novel protective relay was designed using the TMS320C32 digital signal processor and consisted of DSP module. A/D converter module, DI/DO module, MMI interface module and LCD display module and developed by Xelpower co., Ltd.

  • PDF

The Arcing Faults Simulation and Adaptive Autoreclosure Strategy for 765 kV Transmission Line Protection (765 kV 송전선로 보호를 위한 아크사고 시뮬레이션 및 적응적 자동재폐로 대책)

  • Ahn, Sang-Pil;Kim, Chull-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.11
    • /
    • pp.1365-1373
    • /
    • 1999
  • In many countries including Korea, in order to transmit the more electric power, the higher transmission line voltage is inevitable. So, a rapid reclosing scheme is important for EHV/UHV transmission lines to ensure requirements for high reliability of main lines. A critical aspect of reclosing operation is the extinction of the secondary arc since it must extinguish before successful reclosure can occur. Therefore the accurate simulation techniques of arcing faults are of importance. And successful reclosing switching can be accomplished by adopting a proper method such as HSGS and hybrid scheme to reduce the secondary arc extinction time. First of all, this paper discusses a suggested arc model, which have time dependent resistance for primary arc and piecewise linear approximated arc model for secondary arc. And this simulation technique is applied to Korean 765 kV transmission lines. Also hybrid scheme is simulated and evaluated for the purpose of shortening dead time. For adaptive reclosing scheme, variable dead time control algorithm is suggested. Two kinds of algorithm are tested. One is max tracking algorithm and the other is rms tracking algorithm. According to simulation results, rms tracking has less errors than max tracking. Therefore rms tracking is applied to Korean 765 kV transmission lines with hybrid scheme.

  • PDF

A Study of Routing and Signaling Extensions of GMPLS for QoS Provision in NGN (NGN에서 QoS 제공을 위한 GMPLS의 라우팅 및 시그널링 화장 연구)

  • 장석기;박광채
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.5
    • /
    • pp.925-933
    • /
    • 2003
  • Network is expected to be developed into optical Internet network collected IP layer and optical layer, but GMPLS is risen at the transitional evolution stage because of the present technology level. GMPLS that MPLS is extended and generalized is able to support not only the packet switching device but also the devices which perform switching in time, wavelength, and space domain. To implement the common control plane to these various switching types, GMPLS extends the existing MPLS signaling and routing protocol. In this paper, we describe the overview of GMPLS technology, and then we will refer to the OSPF(Open Shortest Path First), which was used to exchange the status information of link, as the plan of routing extension to exchange the information of various link type, bandwidth, link protection type etc. And also, we describe the definition of new protocol, so called, LMP that is a signaling protocol for solving complex problem which manages hundreds and thousands of links between two nodes. And we will examine and analyze the plan of signaling protocol extension to apply signaling protocol RSVP-TE(Resource Reservation Protocol) for traffic engineering in MPLS to network, and the message objects and formats associated with modified RSVP.

Electrical Characteristic of Power MOSFET with Zener Diode for Battery Protection IC

  • Kim, Ju-Yeon;Park, Seung-Uk;Kim, Nam-Soo;Park, Jung-Woong;Lee, Kie-Yong;Lee, Hyung-Gyoo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.1
    • /
    • pp.47-51
    • /
    • 2013
  • A high power MOSFET switch based on a 0.35 ${\mu}m$ CMOS process has been developed for the protection IC of a rechargeable battery. In this process, a vertical double diffused MOS (VDMOS) using 3 ${\mu}m$-thick epi-taxy layer is integrated with a Zener diode. The p-n+Zener diode is fabricated on top of the VDMOS and used to protect the VDMOS from high voltage switching and electrostatic discharge voltage. A fully integrated digital circuit with power devices has also been developed for a rechargeable battery. The experiment indicates that both breakdown voltage and leakage current depend on the doping concentration of the Zener diode. The dependency of the breakdown voltage on doping concentration is in a trade-off relationship with that of the leakage current. The breakdown voltage is obtained to exceed 14 V and the leakage current is controlled under 0.5 ${\mu}A$. The proposed integrated module with the application of the power MOSFET indicates the high performance of the protection IC, where the overcharge delay time and detection voltage are controlled within 1.1 s and 4.2 V, respectively.

AC/DC Converter Suitable for a Pulsed Mode Switching DC Power Supply (펄스모드 스위칭 직류전원 장치에 적합한 AC/DC 켄버터)

  • Moon S. H.;Nho E. C.;Kim I. D.;Kim H. G.;Chun T. W.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.378-381
    • /
    • 2002
  • This paper describes a novel multilevel ad/dc power converter suitable for the protection of frequent output short-circuit. The output dc power of the proposed converter can be disconnected from the load within several hundred microseconds at the instant of short-circuit fault. The rising time of the dc load voltage is as small as several hundred microseconds, and there is no overshoot of the do voltage because the dc output capacitors keep undischarged state. Analysis and simulations are carried out to investigate the operation and usefulness of the proposed scheme.

  • PDF