• 제목/요약/키워드: prosthesis and implants

검색결과 389건 처리시간 0.041초

Initiation and propagation of a crack in the orthopedic cement of a THR using XFEM

  • Gasmi, Bachir;Abderrahmene, Sahli;Smail, Benbarek;Benaoumeur, Aour
    • Advances in Computational Design
    • /
    • 제4권3호
    • /
    • pp.295-305
    • /
    • 2019
  • The sealing cement of total hip arthroplasty is the most widely used binder in orthopedic surgery for anchoring implants to their recipient bones. Nevertheless, this latter remains a fragile material with weak mechanical properties. Inside this material cracks initiate from cavities. These cracks propagate under the effect of fatigue and lead to the failure of this binder and consequently the loosening of the prosthesis. In this context, this work consists to predict the position of cracks initiation and their propagations path using the Extended Finite Element Method (XFEM). The results show that cracks can only be initiated from a sharp edges of an ellipsoidal cavity which the ratio of the minor axis over the major axis is equal to 0.1. A maximum crack length of 19 ?m found for a cavity situated in the proximal zone position under a static loading. All cracks propagate in same(almost) way regardless of the cavity(site of initiation) position and its inclination in the proximal zone.

Wear resistance of indirect composite resins used for provisional restorations supported by implants

  • Tsujimoto, Akimasa;Jurado, Carlos;Villalobos-Tinoco, Jose;Barkmeier, Wayne;Fischer, Nicholas;Takamizawa, Toshiki;Latta, Mark;Miyazaki, Masashi
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권4호
    • /
    • pp.232-238
    • /
    • 2019
  • PURPOSE. The aim of this study was to investigate simulated localized and generalized wear of indirect composite resins used for implant supported provisional restorations. MATERIALS AND METHODS. The study investigated ten indirect composite resins. Two kinds of wear were simulated by 400,000 cycles in a Leinfelder-Suzuki (Alabama) machine. Localized wear was simulated with a stainless-steel ball bearing antagonist and generalized with a flat-ended stainless-steel cylinder antagonist. The tests were carried out in water slurry of polymethyl methacrylate beads. Wear was measured using a Proscan 2100 noncontact profilometer in conjunction with Proscan and AnSur 3D software. RESULTS. Both localized and generalized wear were significantly different (P<.05) among the indirect composite resins. SR Nexco and Gradia Plus showed significantly less wear than the other indirect composite resins. The rank order of wear was same in both types of wear simulation. CONCLUSION. Indirect composite resins are recommended when a provisional implant-supported restoration is required to function in place over a long period. Although only some indirect composite resins showed similar wear resistance to CAD/CAM composite resins, the wear resistance of all the indirect composite resins was higher than that of bis-acryl base provisional and polymethyl methacrylate resins.

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE IMPLANT FRACTURES

  • Kim Yang-Soo;Kim Chang-Whe;Lim Young-Jun;Kim Myung-Joo
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.295-313
    • /
    • 2006
  • Statement of problem. Higher fracture rates were reported for Branemark implants placed in the maxilla and for 3.75 mm diameter implants installed in the posterior region. Purpose. The purpose of this study was to investigate the fracture of a fixture by finite element analysis and to compare different diameter of fixtures according to the level of alveolar bone resorption. Material and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for the 3i implant systems. Models were processed by the software programs HyperMesh and ANSA. Three-dimensional finite element models were developed for; (1) a regular titanium implant 3.75 mm in diameter and 13 mm in length (2) a regular titanium implant 4.0 mm in diameter and 13 mm in length (3) a wide titanium implant 5.0 mm in diameter and 13 mm in length each with a cementation type abutment and titanium alloy screw. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized as 650 N, and round and flat type prostheses were 12 mm in diameter, 9 mm in height were loaded to 600 N. Four loading offset points (0, 2, 4, and 6 mm from the center of the implants) were evaluated. To evaluate fixture fracture by alveolar bone resorption, we investigated the stress distribution of the fixtures according to different alveola. bone loss levels (0, 1.5, 3.5, and 5.0 mm of alveolar bone loss). Using these 12 models (four degrees of bone loss and three implant diameters), the effects of load-ing offset, the effect of alveolar bone resorption and the size of fixtures were evaluated. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView programs were used for post processing. Results. The results from our experiment are as follows: 1. Preload maintains implant-abutment joint stability within a limited offset point against occlusal force. 2. Von Mises stress of the implant, abutment screw, abutment, and bone was decreased with in-creasing of the implant diameter. 3. With severe advancing of alveolar bone resorption, fracture of the 3.75 and the 4.0 mm diameter implant was possible. 4. With increasing of bending stress by loading offset, fracture of the abutment screw was possible.

무치악 환자에서 CAD/CAM을 이용한 임플란트 식립($NobelGuide^{TM}$) 및 즉시하중 증례 (Restoration of an Edentulous Patient with CAD/CAM Guided Implant Surgery ($NobelGuide^{TM}$) and Immediate Loading: Case Report)

  • 고경호;임광길;김대곤;박찬진;조리라
    • 구강회복응용과학지
    • /
    • 제27권2호
    • /
    • pp.233-245
    • /
    • 2011
  • 임플란트 시술에서 CAD/CAM을 포함한 컴퓨터 기술의 발달은 단순히 임플란트를 보다 정확하고, 예측 가능하게 식립하는 것뿐 아니라, 무피판(flapless) 수술과 즉시하중을 가능하게 하였다. 그러므로 술후 출혈과 불편감의 감소 및 시술시간과 치유기간을 단축시키는 장점이 있으며, 시술 후 즉시 보철물을 장착해 줌으로써 환자의 구강기능을 단기간에 회복시키고 경조직과 연조직의 형태를 보존하여 최종보철 시 유리한 환경을 만들어 줄 수 있게 되었다. 본 증례는 상 하악 무치악 상태로 내원한 40세 남성 환자로 하악 총의치의 불안정성 및 불편감 등을 호소하였으며, 하악에 임플란트 지지 고정성 보철물을 통한 수복을 원하였다. 충분한 골량, 환자의 참여도, 경제적인 여건, 전신적인 건강 등을 고려하여 하악에는 CAD/CAM 기반의 수술용 스텐트를 이용한 수술 및 미리 제작된 고정성 임시보철물을 이용하여 즉시하중을 부여하는NobelGuide 보철을 계획하였으며, 상악에는 총의치를 계획하였다. 환자의 안모를 평가하여 임시의치를 제작하였으며, 복제한 임시의치를 바탕으로 스텐트를 제작하고, 컴퓨터단층촬영을 시행하였다. 3차원으로 변환된 영상을 기반으로 하악에 7개의 고정체를 생역학적 조건과 치조골의 상태에 맞게 분산 배치하였다. 제작된 수술용 스텐트에 맞게 주모형을 제작하고, 임시고정성 보철물을 제작하여 장착함으로써 즉시하중을 부여하였다. 식립 3개월 후 골유착 정도를 평가하고 최종보철물을 제작하였다. 추후 발생할 수 있는 상악 골흡수를 방지하기 위해 주기적인 내원 및 검사를 통해 성공적인 치료가 될 수 있도록 노력하였다.

Autogenous fresh demineralized tooth graft prepared at chairside for dental implant

  • Kim, Eun-Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.8.1-8.6
    • /
    • 2015
  • Background: This study aimed to evaluate the clinical usefulness of autogenous fresh demineralized tooth (auto-FDT) graft prepared at the chairside for alveolar bone grafting during dental implant surgery. Methods: In total, 38 patients requiring both tooth extraction (for endodontic or periodontal reasons or third molar extraction) and alveolar bone regeneration for dental implant placement were included. Within 2 h after clean extraction, the teeth were prepared at the chairside to serve as bone graft material. In the same sitting, blocks or chips of this graft material were used to reconstruct defects at the osteotomy site simultaneously with or before implant placement. Twelve months after prosthesis fabrication and placement, the clinical findings and implant success rates were evaluated. Histological studies were randomly conducted for selected cases. Results: Clinical evaluation showed favorable wound healing with minimal complications and good bone support for the implants. No implant was lost after 12 months of function following prosthetic rehabilitation. Histological examination revealed new bone formation induced by the graft material. Conclusions: Chairside preparation of autogenous fresh demineralized teeth after extraction can be a useful alternative to the use of autogenous bone or other graft materials for the immediate reconstruction of alveolar bone defects to facilitate subsequent implant placement.

임플랜트로 수복된 하악 구치부에 대합되는 자연치 주변의 골변화 (ALVEOLAR BONE CHANGES AROUND THE NATURAL TEETH OPPOSING THE POSTERIOR IMPLANTS IN MANDIBLE)

  • 정원모;김대곤;이양진;박찬진;조리라
    • 대한치과보철학회지
    • /
    • 제45권2호
    • /
    • pp.263-273
    • /
    • 2007
  • Statement of problem: Alteration of tooth function is assumed to be changed by stress/strain on the adjacent alveolar bone, producing changes in morphology similar to those described for other load-bearing bones. When teeth are removed, opposing teeth will not be functioned. When edentulous area is restored by implant prostheses, opposing teeth will be received physiologic mechanical stimuli. Purpose: The aim of this study was to evaluate the bone changes around the teeth opposing implant restoration installed mandibular posterior area. Material and method: Eight patients who had mandibular posterior edentulous area were treated with implants. Radiographs of the opposing teeth were taken at implant prostheses delivery(baseline), 3 months, and 6 months later. Customized film holding device was fabricated to standardize the projection geometry for serial radiographs of opposing teeth. Direct digital image was obtained. Gray values of region of interest at each digital image were measured and compared according to time lapse. Repeated measured analysis of variance and post-hoc Scheffe's test were performed at the 95% significance level. Results: Alveolar bone changes around the natural teeth opposing the posterior implant in mandible showed statistically significant difference compared to control group(P<0.05). And gray values of alveolar bone around the teeth opposing implants were increased. There were no statistically significant differences of alveolar bone changes between crestal group and middle group and between mesial group and distal group according to time lapse(P>0.05). There were no statistically significant differences of alveolar bone changes among mesial-crestal group, mesial-middle group, distal-crestal group, distal-middle group, and control group(P>0.05). Conclusion: Alveolar bone around the natural teeth opposing the implant prosthesis showed gradual bony apposition.

고정성 임플란트 보철물을 이용한 완전구강회복 증례 (Functional and esthetical full mouth rehabilitation with implant supported prostheses: A case report)

  • 연제웅;임영준;권호범;김명주
    • 대한치과보철학회지
    • /
    • 제53권1호
    • /
    • pp.81-85
    • /
    • 2015
  • 본 증례의 환자는 상악 전치부 보철물의 파절 및 기존에 사용하던 하악 의치의 불편감 때문에 임플란트를 이용한 고정성 보철을 원한다는 주소로 내원하였다. 상악동 거상술, 하악지 골이식과 함께 상악에 5개, 하악에 6개의 임플란트를 식립하였다. 전치부와 양쪽 구치부의 세 부분으로 나누어 임플란트 지지형 고정성 보철물을 장착하였다. 이상과 같은 과정을 통해 적절한 심미적, 기능적 결과를 얻었기에 이를 보고하고자 한다.

3차원 프린팅 기술과 이를 활용한 골종양 수술 (Three Dimensional Printing Technique and Its Application to Bone Tumor Surgery)

  • 강현귀;박종웅;박대우
    • 대한정형외과학회지
    • /
    • 제53권6호
    • /
    • pp.466-477
    • /
    • 2018
  • 정형외과는 인체의 모든 근골격계를 담당하기 때문에 3차원(3-dimensional, 3D) 프린팅 기술을 가장 많이 활용할 수 있는 분야이다. 구체적으로 관절염, 척추, 외상, 기형, 종양 등의 다양한 정형외과 질병에 대해 해부학적 모델, 수술용 가이드, 금속 임플란트, 바이오-세라믹 재건, 보조기 등의 형태로 활용될 수 있다. 특히 정형외과 종양 영역은 환자마다 종양의 발생 위치와 크기가 다양한 데 반하여 사지 보존 수술에 활용할 수 있는 기존의 수술 방법이 제한적이었기 때문에 3D 프린팅 기술의 활용이 매우 절실한 분야였다. 최근에 3D 프린팅 환자 맞춤형 임플란트를 짧은 시간 내에 쉽게 제작할 수 있게 되면서 기존 방법으로 골 재건이 어려웠던 부위에 대해서도 해부학적 재건이 가능하게 되었다. 3D 프린팅 기술을 의료 영역에서 더욱 폭넓게 사용하기 위해서는 디자인, 출력, 검증 과정에 필요한 많은 전문가들과 함께 수평적 위치에서 긴밀히 협력해야 한다. 의료계에서 3D 프린팅을 활용을 선도함으로써 다른 분야의 전문가 양성 및 3D 프린팅 관련 산업의 발달을 촉진시킬 수 있다고 판단한 정부도 규제보다는 활성화에 역점을 두고 적극적으로 지원하고 있는 추세이다. 앞으로 정형외과가 전체 의료계에서 3D 프린팅 기술의 도입과 활용을 선도해 가기를 기대하면서 골종양 수술에서 3D 프린팅 기술을 활용하였던 저자의 경험을 소개하고자 한다.

상악 구치부 임플랜트 보철수복시 치관/치근비에 따른 응력 분포에 대한 유한 요소 분석 (FINITE ELEMENT ANALYSIS ON MAXILLARY MOLAR IMPLANT UNDER DIFFERENT C/R RATIO)

  • 김진호;김형섭;최대균;권긍록
    • 대한치과보철학회지
    • /
    • 제44권5호
    • /
    • pp.561-573
    • /
    • 2006
  • Statement of the problem: In cases of low bone level in maxilla followed by extraction due to severe periodontitis or enlarged maxillary sinus, crown-root ratio of implant prosthesis will increase. The prognosis of these cases is not good as expected. Purpose : The purpose is to compare stress distribution due to crown-root ratio and effect of splinting between two implants in maxillary molar area under different loads Material and methods: Using ITI($4.1{\times}10$ mm) implant. two finite element models were made(model S: two parallel implants, model A: one of two is 20 degree inclined). Each model was designed in different crown-root ratio(0.7:1, 1:1, 1.25:1) and set cement type gold crown to make it splinted or non-splinted clinical situations. After that, 300 N force was loaded to each model in four ways.(load 1 : middle of occlusal table, load 2 : middle of buccal cusp, load 3 : middle of lingual cusp, load 4 : horizontal load to middle of buccal cusp), and stress distribution was analyzed. Results: On all occasions, stress was concentrated on neck of implant near cortical bone. In the case of inclined implant, stress was increased compared with parallel implants. Under load 1, 2, 3, stress was not increased even when crown-root ratio increases, but under load 4, when crown-root ratio increases, stress also increased. And more stress was concentrated under load 1 than load 2, 3. When crown-root ratio was same, stress under load 1, 2, 3 decreased when splinting, but under load 4, stress did not really decrease. Conclusion: Under vertical load, stress distribution related to crown-root ratio did not change. But under horizontal load, stress increased as crown-root ratio increases. Under vertical load, splinting decreased stress but under horizontal load, effect of splinting was decreased as condition of implant changes for the worse such as increase of crown-root ratio, inclined implant.

과도한 마모를 보이는 환자에서, 임플란트를 활용해 수직 고경을 증가시키며 shortened dental arch 개념을 적용한 보철 수복 증례 (Using implants for worn dentition with the altered vertical dimension of occlusion based on shortened dental arch concept: a case report)

  • 이재현;김태수;이철원;이원섭;이수영
    • 대한치과보철학회지
    • /
    • 제54권1호
    • /
    • pp.49-56
    • /
    • 2016
  • 과도한 마모 같은 잔존 치아 구조의 파괴는 전치유도와 저작 기능에 심각한 손상을 초래할 수 있다. 이런 증상을 개선시키기 위해서는 상실된 구치부를 수복하여 적절한 교합을 회복시켜주는 것이 필수적이다. 구치부의 무치악부를 수복하기 위해서는 의치나 임플란트가 사용될 수 있는데, 임플란트로 수복시에는 경제적인 제약으로 위해 shortened dental arch 개념을 적용하는 것이 유리할 수 있다. 본 증례는 86세 남환으로, 다수의 치아가 상실되어 있었고, 구치부 교합의 붕괴와 과도한 치질 소실, 수직 피개를 관찰할 수 있었다. 구치부에서 붕괴된 교합을 재형성해주는 것을 최우선 과제로 정하였으며, 가철성 보철물 대신, 국민건강보험이 적용된 2개의 임플란트와 고정성 국소의치, 레진을 이용하여 보철 수복을 완료하였다. 소구치 부위에서 2 mm의 수직고경을 거상하였으며, shortened dental arch 개념을 적용하였다. 이를 통해 전악 수복에 비하여 적은 비용으로 이를 대체하는 치료를 고정성 보철물로 할 수 있었으며, 심미적, 기능적으로 양호한 결과를 얻었다.