• Title/Summary/Keyword: prosthesis and implants

Search Result 395, Processing Time 0.029 seconds

Clinical considerations for appropriate occlusion of implant restorations (임플란트 보철 교합의 임상적 고려 사항)

  • Park, Young-Bum
    • The Journal of the Korean dental association
    • /
    • v.53 no.6
    • /
    • pp.418-426
    • /
    • 2015
  • The appropriate occlusion is one of the most important factors for the long-term success of implant and its restorations. The purpose of this review is to investigate and define occlusal considerations to reduce failure of implant prostheses. The physiological movement of implants is markedly lower than that of natural teeth and they also lack in occlusal sensitivity. Proper occlusal pattern may be assigned to compensate for the biological disadvantages and occlusal contacts must be formed where the cantilever effect is minimized. Moreover, the long-term success of implants after osseointegration can be assured by reducing early occlusal loading to avoid implant overloading and selecting appropriate occlusion material. Occlusal overload was brought by the number and location of occlusal contacts, which are under the clinician's control. The concept of implant occlusion is based on the concepts derived from traditional prosthetics. Moreover, there are few evidence on the concept or design of implant occlusion. Several occlusal design was recommended for implant prosthesis. Mutually protected occlusion, group function occlusion and bilateral balance occlusion was recommended for the specific types of implant restorations. This article reviews proper design of occlusion for implant restoration and offers occlusion strategy clinically.

Extracting 3D Geometry Parameters of Hip Joint for Designing a Custom-Made Hip Implant (맞춤형 인공관절 설계를 위한 인체 고관절의 3차원 형상 정보 추출)

  • Seo, Jeong-Woo;Jun, Yong-Tae
    • Korean Journal of Computational Design and Engineering
    • /
    • v.13 no.3
    • /
    • pp.200-208
    • /
    • 2008
  • Total Hip Replacement(THR) is a surgical procedure that replaces a diseased hip joint with a prosthesis. A plastic or metal cup forms the socket, and the head of the femur is replaced by a metal ball on a stem placed inside the femur. Due to the various types and shapes of human hip joint of every individual, a selected commercial implant sometimes may not be the best-fit to a patient, or it cannot be applied because of its discrepancy. Hence extracting geometry parameters of hip joint is one of the most crucial processes in designing custom-made implants. This paper describes the framework of a methodology to extract the geometric parameters of the hip joint. The parameters include anatomical axis, femoral head, head offset length, femoral neck, neck shaft angle, anteversion, acetabulum, and canal flare index. The proposed system automatically recommends the size and shape of a custom-made hip implant with respect to the patient's individual anatomy from 3D models of hip structures. The proposed procedure creating these custom-made implants with some typical examples is precisely presented and discussed in this paper.

A HISTOLOGICAL STUDY OF SURROUNDING BONE TISSUE REACTION TO HYDROXY APATITE COATED DENTAL IMPLANT (Hydroxy Apatite가 피복된 치과매식체의 주위골조직 반응에 관한 조직학적 연구)

  • Song, Joon-Ki;Hur, Sung-Joo;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.23-34
    • /
    • 1991
  • Even if we can recover the function of mastication, pronunciation and esthetic using the fixed or removable prosthesis in the loss of teeth or hard tissue in the oral cavity, we use several kinds of implants in order to solve the problem which can be occured when we can't install the denture because of excessive bone resolution or psychlogical affairs. At present Titanium implant plays a major role in this field and has osseointegrated. And the study on the modern material is going on, that result in developing and using the implant which is coated with HA, bone induced material. In this, I studied histologically the change of the bone tissue which is occured when three kinds of HA coated implants. Such as Integral, Sustain, Biovent implanted into mandible of dog and got a 8-weeks healing period. I got the conclusion as follows: 1. Most of the implant which is covered with serveral kinds of HA coating implant in bone after 8 weeks being implanted and has osseointegrated, partially converted into the connective tissue. 2. Biovent formed the connective tissue in the perforated area of inferior alveolar canal and has osseointegrated.

  • PDF

Finite Element Stress Analysis of Implant Prosthesis according to Position and Direction of Load (하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소법적 응력분석)

  • Bae, Sook-Jin;Chung, Chae-Heon;Jeong, Seung-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.4
    • /
    • pp.257-268
    • /
    • 2003
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis according to position and direction of load, under vertical and inclined loading using FEA analysis. The finite element model was designed according to standard fixture (4.1mm restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric usp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant in both vertical and oblique loading but stresses in the cancellous bone were low in both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. 4. The relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 5. The magnitude of the stress in the supporting bone, fixture and abutment screw was greater with the outward oblique loading than with the inward oblique loading and was the greatest under loading at the centric cusp in a $30^{\circ}$ outward oblique direction. Conclusively, this study provides evidence that bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. But it seems to be more important that how long is the distance from center of rotation of the implant itself to the resultant line of force from occlusal contact(leverage). The goal of improving implants should be to avoid bending of the implant.

THE MANAGEMENT OF A COMPLEX IMPLANT CASE USING CAD-CAM TECHNOLOGY: A CLINICAL REPORT

  • Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.634-638
    • /
    • 2008
  • PURPOSE: The application of computer-aided technology to implant dentistry has created new opportunities for treatment planning, surgery and prosthodontic treatment, but the correct selection and combination of available methods may be challenging in times. Hence, the purpose of this case report is to present a combination of several computer-aided tools as approaches to manage complicated implant case. MATERIAL AND METHODS: A 47 year-old female patient with severe dental anxiety, high expectations, financial restrictions and poor compliance presented for a fixed rehabilitation. A CT scan with a radiographic template obtained with software (SimPlant, Materialize, Leuven, Belgium) was used for treatment planning. The surgical plan was created and converted into a stereolithographic model of the maxilla with bone-supported surgical templates (SurgiGuide, Materialise, Leuven, Belgium), that allowed for the precise placement of 7 implants in a severely resorbed edentulous maxilla. After successful osseointegration, an accurate scan model served as the basis for the fabrication of a one-piece milled titanium framework using the Procera (Nobel Biocare, Gothenburg, Sweden) technology. The final rehabilitation of the edentulous maxilla was rendered in the form of a screw-retained maxillary metal-reinforced resin-based complete prosthesis. RESULTS: Despite challenging circumstances, 7 implants could be placed without bone augmentation in a severely resorbed maxilla using the SimPlant software for pre-implant analysis and the SurgiGuide-system as the surgical template. The patient was successfully restored with a fixed full arch restoration, utilizing the Procera system for the fabrication of a milled titanium framework.

An 1 year prospective comparative study evaluating the effect of microthread on the maintenance of marginal bone level (임프란트 미세나사선이 주위골 수준변화에 미치는 영향에 대한 1년간의 전향적 비교 연구)

  • Shin, Dong-Hwan;Cho, Kyoo-Sung;Park, Kwang-Ho;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.349-358
    • /
    • 2003
  • The success of dental implant therapy relies mainly upon the presence and maintenance of bone adjacent to implant. An 1-year prospective study was performed, upon the patients who were diagnosed as having chronic adult periodontitis, and had been treated with dental implant. The purpose of this study was to measure the radiographic bone level changes proximal to Astra Tech Single Tooth Implants (ATST, Astra Tech AB, $M{\"{o}}lndal$, Sweden) with microthread and Astra Tech TiOblast Implant (ATTB) without microthread supporting fixed partial prosthesis. Measurements were used to determine mean marginal bone loss during the first year of loading, 17 subjects with its partial prosthesis supported by 37 implants were followed up for an 1-year period. The marginal bone loss of implants was positively correlated with the retention factor, microthread($Microthread^{TM}$) in crestal area of ATST. The results were as follows. 1. The mean marginal bone loss of ATST was 0.226${\pm}$0.395mm, while ATTB was 0.440${\pm}$0.360mm. There was a statistically significant difference between ATST and ATTB (p<0.05). 2. The mean bone loss of the upper jaw fixtures was 0.269${\pm}$0.265mm for ATST and 0.529${\pm}$0.417mm for ATTB . There was a statistically significant difference between ATST and ATTB (p<0.05). In the lower jaw the corresponding figures were 0.167${\pm}$0.231mm and 0.313${\pm}$0.214mm, respectively. There was no significant difference between ATST and ATTB (p>0.05). 3. The mean bone loss of ATST was lower than that of ATTB at all sites according to bone quality. There was a statistically significant difference between ATST and ATTB at bone quality type III(p <0.05). In conclusion, the mean bone loss of ATST was smaller than that of ATTB . Therefore, the retention factor of crestal area, microthread ($Microthread^{TM}$) was effective to maintenance of marginal bone level around fixture.

PROSTHETIC REHABILITATION OF THE PARTIALLY EDENTULOUS PATIENT BY USING OSSEOINTEGRATE IMPLANT AFTER REMOVAL OF AMELOBLASTOMA (법랑아세포종 제거후의 Implant보철수복 증례)

  • Ahn, Sang-Hun;Kim, Jong-Pil;Jo, Byung-Woan;Ahn, Jye-Jynn
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.1
    • /
    • pp.95-102
    • /
    • 1997
  • Ameloblastoma is the most agrressive ofht odontogenic tumors and it arises from the dental lamina or the derivatives of lamina. Ameloblastoma is a benign but locally invasive neoplasm consisting of proliferating odontogenic epithelium lying in a fibrous stroma. Usually the ameloblastomas are diagnosed in the forth and fifth decardes. Over 80% of them occur in the mandible, the remainder in the maxilla. The preferred treatment for ameloblastoma is radical excision, conserving(when possible. the inferior border of the mandible. The functional and esthetic rehabilitation of the partially edentulous patient may prevent the remaining structures from supporting conventional prosthetic treatment. Patients with long edentulous spans, malpositioned teeth, residual ridges defects and high muscle attachments may be offered an osseointegrated fixed prosthesis. Osseointegrated dental implants provide a viable alternative of tooth replacement. This is a case report of 16 year old female with ameloblastoma. We treated patient with radical excision, conserving the inferior border of the mandible and allogenous bone graft. The defected residual ridge area was reconstructed implants(Steri-Oss Implant System). the result was satisfactory.

  • PDF

EFFECT OF ANCHORAGE SYSTEMS ON LOAD TRANSFER WITH MANDIBULAR IMPLANT OVERDENTURES : A THREE-DIMENSIONAL PHOTOELASTIC STRESS ANALYSIS (하악 임플란트 overdenture에서 anchorage system이 하중전달에 미치는 영향)

  • Kim Jin-Yeol;Jeon Young-Chan;Jeong Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.507-524
    • /
    • 2002
  • Load transfer of implant overdenture varies depending on anchorage systems that are the design of the superstructure and substructure and the choice of attachment. Overload by using improper anchorage system not only will cause fracture of the framework or screw but also may cause failure of osseointegration. Choosing anchorage system in making prosthesis, therefore, can be considered to be one of the most important factors that affect long-term success of implant treatment. In this study, in order to determine the effect of anchorage systems on load transfer in mandibular implant overdenture in which 4 implants were placed in the interforaminal region, patterns of stress distribution in implant supporting bone in case of unilateral vertical loading on mandibular left first molar were compared each other according to various types of anchorage system using three-dimensional photoelastic stress analysis. The five photoelastic overdenture models utilizing Hader bar without cantilever using clips(type 1), cantilevered Hader bar using clips(type 2), cantilevered Hader bar with milled surface using clips(type 3), cantilevered milled-bar using swivel-latchs and frictional pins(type 4), and Hader bar using clip and ERA attachments(type 5), and one cantilevered fixed-detachable prosthesis(type 6) model as control were fabricated. The following conclusions were drawn within the limitations of this study, 1. In all experimental models. the highest stress was concentrated on the most distal implant supporting bone on loaded side. 2. Maximum fringe orders on ipsilateral distal implant supporting bone in a ascending order is as follows: type 5, type 1, type 4, type 2 and type 3, and type 6. 3. Regardless of anchorage systems. more or less stresses were generated on the residual ridge under distal extension base of all overdenture models. To summarize the above mentioned results, in case of the patients with unfavorable biomechanical conditions such as not sufficient number of supporting implants, short length of the implant and unfavorable antero-posterior spread. selecting resilient type attachment or minimizing distal cantilever bar is considered to be appropriate methods to prevent overloading on implants by reducing cantilever effect and gaining more support from the distal residual ridge.

Changes in the fractal dimension of peri-implant trabecular bone after loading: a retrospective study

  • Mu, Teh-Jing;Lee, Dong-Won;Park, Kwang-Ho;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.5
    • /
    • pp.209-214
    • /
    • 2013
  • Purpose: To assess bony trabecular changes potentially caused by loading stress around dental implants using fractal dimension analysis. Methods: Fractal dimensions were measured in 48 subjects by comparing radiographs taken immediately after prosthesis delivery with those taken 1 year after functional loading. Regions of interest were isolated, and fractal analysis was performed using the box-counting method with Image J 1.42 software. Wilcoxon signed-rank test was used to analyze the difference in fractal dimension before and after implant loading. Results: The mean fractal dimension before loading ($1.4213{\pm}0.0525$) increased significantly to $1.4329{\pm}0.0479$ at 12 months after loading (P<0.05). Conclusions: Fractal dimension analysis might be helpful in detecting changes in peri-implant alveolar trabecular bone patterns in clinical situations.

Rehabilitation of a crossed-occlusion patient using implant-assisted removable partial denture with Locator® attachment: A case report (엇갈린 교합 및 교합평면 부조화를 가진 부분무치악 환자에서 임플란트를 이용한 가철성 국소의치 증례)

  • Kim, Dong-Woon;Choi, Jung-Yun;Seo, Jae-Min;Lee, Jung-Jin
    • The Journal of the Korean dental association
    • /
    • v.54 no.7
    • /
    • pp.513-520
    • /
    • 2016
  • In crossed occlusion, displacement of removable partial denture is likely to occur during function due to different characteristics of abutment and supporting tissue. It increases discomfort to the patient. In addition, adverse effect on the residual ridge and abutment can induce an unfavorable prognosis of the denture. In this case, a small number of implants can be placed in strategic locations. Attachment can be added for additional support and retention of removable partial denture assisted by implants. This article describes the rehabilitation of a crossed occlusion patient using implant-assisted removable partial denture with Locator$^{(R)}$ attachment. After 24 months, the patient was satisfied with the aesthetic and function of the prosthesis that is maintained stable.

  • PDF