• 제목/요약/키워드: profilometry

검색결과 81건 처리시간 0.021초

A Study on the Profile Change Measurement of Steam Generator Tubes with Tube Expansion Methods

  • Kim, Young-Kyu;Song, Myung-Ho;Choi, Myung-Sik
    • 비파괴검사학회지
    • /
    • 제31권5호
    • /
    • pp.543-551
    • /
    • 2011
  • Steam generator tubes for nuclear power plants contain the local shape transitions on their inner or outer surface such as dent, bulge, over-expansion, eccentricity, deflection, and so on by the application of physical force during the tube manufacturing and steam generator assembling and by the sludge (that is, corrosion products) produced during the plant operation. The structural integrity of tubes will be degraded by generating the corrosive crack at that location. The profilometry using the traditional bobbin probes which are currently applied for measuring the profile change of tubes gives us basic information such as axial locations and average magnitudes of deformations. However, the three-dimensional quantitative evaluation on circumferential locations, distributional angle, and size of deformations will have to be conducted to understand the effects of residual stresses increased by local deformations on corrosive cracking of tubes. Steam generator tubes of Korean standard nuclear power plants expanded within their tube-sheets by the explosive expansion method and suffered from corrosive cracks in the early stage of power operation. Thus, local deformations of steam generator tubes at the top of tube-sheet were measured with an advanced rotating probe and a laser profiling system for the two cases where the tubes expanded by the explosive expansion method and hydraulic expansion. Also, the trends of eccentricity, deflection, and over-expansion of tubes were evaluated. The advanced eddy current profilometry was confirmed to provide accurate information of local deformations compared with laser profilometry.

위상이동 형상측정법을 이용한 도재 소성시의 도재 수축률의 측정 (Measurement of Porcelain Shrinkage After Firing Using the Phase-Shifting Profilometry)

  • 이청희
    • 대한치과보철학회지
    • /
    • 제37권6호
    • /
    • pp.800-808
    • /
    • 1999
  • To compare several porcelains made by various manufacturers in shrinkage after firing and investigate the effect of condensation on shrinkage, specimens were prepared and the volume of each body was measured by the phase-shifting profilometry. Baseplate wax was cut by $2.5cm{\times}2cm$ and cast in nonprecious metal(Verabond, U.S.A.), then any surfaces of specimens were abrased and polished on the SiC abrasing papers, preparing 120 specimens. Specimens were divided into six groups according to the porcelain used, and the porcelain used in each group were as follows. Group I : Ceramco dentin porcelain Group B : Creation dentin porcelain Group III : Creation margin porcelain Group IV : Vintage margin porcelain Group V : Vita dentin porcelain Group VI : Vintage dentin porcelain Porcelain was built up on the metal plates using a small spoon and then solution matching to each porcelain was added. The six groups are subdivided into a and b. In subgroup a, only excessive solution was absorbed with tissue and in subgroup b, porcelain was condensed sufficiently. When build-up was completed, the shape was measured using the phase-shifting profilometry. After that, specimens were fired in the furnace programed for each porcelain and then their changed shape were measured again. Using the difference between the two above measurements, the ratio of shrinkage was calculated. Obtained results were as follows ; 1. Regardless of condensation, the volume of fired specimens were not different significantly between the two subgroups a and b in the same group. 2. The ratios of shrinkage were significantly higher in the groups porcelain built-up was condensed than in the groups not condensed 3. The ratios of shrinkage were in the range of 36.81-27.19% in the groups porcelain built up was condensed and 44.52-37.54% in the other groups not condensed.

  • PDF

GPU를 이용한 위상 측정법의 가속화 (Acceleration of Phase Measuring Profilometry using GPU)

  • 김호중;조태훈
    • 한국정보통신학회논문지
    • /
    • 제21권12호
    • /
    • pp.2285-2290
    • /
    • 2017
  • 최근 산업의 여러 분야에서 자동화 시스템이 발전함에 따라 3D 측정에 의한 물체의 높이 검사의 필요성이 점차 대두되고 있다. 여러 3D 측정 방법 중에서 본 논문에서 다루는 방법은 위상 측정법으로, 위상 측정법이란 프린지 패턴의 위상값을 이용하여 물체의 높이를 구하는 방법이다. 위상 측정법은 연산량이 많이 필요한 알고리즘이기 때문에 이를 효율적으로 해결할 방법이 필요하다. 본 논문에서는 이를 위해 NVIDIA에서 나온 CUDA를 사용할 것을 제안했다. 또 CUDA에서 제공하는 Pinned memory와 Stream을 사용할 것을 제안하였다. 이를 통해 정확도를 유지하면서 측정 속도는 크게 향상시킬 수 있었고 실험을 통해 성능을 입증하였다.

하이퍼센트릭 광학계를 이용한 구조 조명 형상 측정 방법 (Profilometry based on Structured Illumination with Hypercentric Optics)

  • 김성민;조민국;이맹진;한준구
    • 제어로봇시스템학회논문지
    • /
    • 제19권12호
    • /
    • pp.1089-1093
    • /
    • 2013
  • Depth extraction using the structured illumination method is popularly applied since it has the benefit of measuring the object without contact. With multiple spatial frequencies and phase-shifting techniques, it is possible to extract the depth of objects with large discontinuity. For applications such as 3D (Three Dimensional) displays, 3D information of the object is required and is useful if corresponding to each view of the display. For this purpose, hypercentric optics is appropriate to measure the depth information of an object with a large field of view that is applicable for a 3D display. By experiment, we present the feasibility for phase-shifting profilometry using hypercentric optics to obtain the depth information of an object with the field of view appropriate for a 3D display.

위상이동 형상측정법을 이용한 의치 중합 방법에 따른 적합도 검사 (FITNESS TEST USING THE PHASE-SHIFTING PROFILOMETRY ACCORDING TO THE DENTURE CURING METHODS)

  • 이청희;조광헌;최부병
    • 대한치과보철학회지
    • /
    • 제37권4호
    • /
    • pp.474-493
    • /
    • 1999
  • According to repeated measurements and correction procedures, the accuracy of the phase-shifting profilometry was developed. At first, after 20 final models for maxillary complete denture were duplicated , the mucosa sur-faces of models were measured with the phase-shifting proflometry and each mirror view of these was calibrated. Maxillary casts were divided into 4 groups of 5 casts per each, and wax dentures with 2 sheets of baseplate wax and artificial teeth were made and then cured according to the curing method of each group. Group I ; quick curing with QC-20 acrylic resin Group II ; 9 hour curing with QC-20 acrylic resin Group III ; SR-Ivocap system Group IV ; metal base and quick curing with QC-20 acrylic resin. After curing, polishing, and storing at $37^{\circ}C$ in saline for 30 days, the forms of the impression surface of the dentures were measured with the phase-shifting profilometry. Then, the impression surface form of each denture was placed in the optimal position of com-parison with the mirror view of the same final cast. The amount and direction of distortion of each denture was analyzed and the effects of polishing and storage in each denture were compared, The obtained results were as follows : 1. In Group I, the denture was observed as the appearance distorted in the opposite direction of the mucosa and the postero-lateral part of palatal portion of the denture was observed as the appearance separated from the mucosa. Also, the buccal flanges of the denture were observed as the appearance distorted in the direction of the mucosa. 2. In Group II, the postero-lateral part of palatal portion of the denture was observed as the appearance separated slightly from the mucosa. The bilateral buccal flanges of denture were observed as the appearance distorted severely in the direction of the mucosa. 3. In Group III the bilateral part of the residual ridge crest portions and the buccal flanges of the denture were observed as the appearance distorted in the direction of the mucosa, and specially, the buccal flanges of the maxillary tuberosities were distorted severely. 4. In Group IV, the acrylic resin base of the buccal portion of the denture was observed as the appearance distorted in the opposite direction of the mucosa. 5. The phase-shifting profilometry, done with repeated measurements and correction procedures, was effective in comparing the amount and direction of distortion at every position after the laboratory work and the delivery of maxillary complete denture.

  • PDF

PMP 형상 측정법의 열 변위 보정에 관한 연구 (A Study on the Compensation of Thermal Errors for Phase Measuring Profilometry)

  • 김기승;박윤창
    • 한국산학기술학회논문지
    • /
    • 제20권6호
    • /
    • pp.598-603
    • /
    • 2019
  • 삼차원 형상 측정 기술은 다양한 산업에서 활용하고 있는 기술이다. 그 중, 광 삼각법에 기초한 광학식 삼차원 형상 측정 기술들은 매일 공장에서 오랜 시간 동안 대량의 삼차원 형상 측정을 하고, 미세한 측정 또한 요구되는 반도체 생산품 검사 분야에서 주로 사용된다. 이러한 광 삼각법 기반의 삼차원 측정 장비들의 구성 요소인 광원과 구동 회로는 장시간 작동하게 되면 발열이 나타나게 되고 장시간 작동하며 주변의 온도가 일정하지 않은 상황에 노출되기도 하여 온도로 인한 측정 오차가 발생하게 된다. 본 논문에서는 장시간 반복해서 사용하는 PMP(Phase Measuring Profilometry) 형상 측정법에서의 열 변위 보정에 관한 방법을 제안하였다. PMP 형상 측정법 기반의 삼차원 형상 측정 장치를 구현하여 10시간에 걸쳐 물체의 높이와 주변 온도를 측정하는 실험을 진행하였고, 측정된 온도와 높이 값을 이용하여 단순 선형 회귀 분석을 하여 회귀직선을 얻었다. 이 회귀직선을 이용하여 온도에 따른 높이 측정값의 오차를 보정하게 되면 정상적인 측정값에서의 오차 값이 139.88 um(Micrometer) 에서 13.12 um로 보정되는 것을 확인하였다.

PMP 형상 측정법의 위상보정에 관한 연구 (A study on the phase calibration of the phase measuring profilometry)

  • 이연태;강영준;황용선
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.421-424
    • /
    • 2002
  • The 3-D measurement using a sinusoidal grating pattern projection is very attractive because of its high measuring speed and high sensitivity. When a sinusoidal amplitude grating was projected on an object, the surface-height distribution of the object is translated into a phase distribution of the deformed grating image. The phase-acquisition algorithms are so sufficiently simple that high-resolution phase maps using a CCD camera can be generated in a short time. The PMP technique is discussed, and the analysis of the systematic errors, the calibration procedure designed to determined the optimal setting of the measurement parameters is illustrated. Results of measurements and calibrations on the measurement plane objects are described.

  • PDF

Ultra High-speed 3-dimensional Profilometry Using a Laser Grating Projection System

  • Park, Yoon-Chang;Ahn, Seong-Joon;Kang, Moon-Ho;Kwon, Young-Chul;Ahn, Seung-Joon
    • Journal of the Optical Society of Korea
    • /
    • 제13권4호
    • /
    • pp.464-467
    • /
    • 2009
  • The grating projection method with phase-shifting technique is very useful in measuring the 3-dimensional (3D) shape with high accuracy and speed. In this work, we have developed an ultra high-speed digital laser grating projection system using a high-power laser diode and a highsensitivity CMOS camera. With our system, the optical measurement required to find out the profile of a 3D object could be carried out within 2.6 ms, which is a significant ($\sim$10 times) improvement compared with those of the previous studies.

3-D Surface Profile Measurement Using An Acousto-optic Tunable Filter Based Spectral Phase Shifting Technique

  • Kim, Dae-Suk;Cho, Yong-Jai
    • Journal of the Optical Society of Korea
    • /
    • 제12권4호
    • /
    • pp.281-287
    • /
    • 2008
  • An acousto-optic tunable filter based 3-D micro surface profile measurement using an equally spaced 5 spectral phase shifting is described. The 5-bucket spectral phase shifting method is compared with a Fourier-transform method in the spectral domain. It can provide a fast measurement capability while maintaining high accuracy since it needs only 5 pieces of spectrally phase shifted imaging data and a simple calculation in comparison with the Fourier transform method that requires full wavelength scanning data and relatively complicated computation. The 3-D profile data of micro objects can be obtained in a few seconds with an accuracy of ${\sim}10nm$. The 3-D profile method also has an inherent benefit in terms of being speckle-free in measuring diffuse micro objects by employing an incoherent light source. Those simplicity and practical applicability is expected to have diverse applications in 3-D micro profilometry such as semiconductors and micro-biology.