• Title/Summary/Keyword: probing

Search Result 823, Processing Time 0.027 seconds

Clinical evaluation of full mouth disinfection therapy (Full mouth disinfection therapy의 단기간 임상 효과 연구)

  • Cho, Ik-Hyun;Jung, Ui-Won;Cha, Jeong-Heon;Kim, Joong-Su;Lee, Dae-Sil;Kim, Chang-Seong;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.3
    • /
    • pp.597-608
    • /
    • 2005
  • The aim of this study is to determine whether full-mouth disinfection therapy(FMT) in our clinical setting would show better improvement of clinical parameters than partial mouth disinfection therapy(PMT) in chronic periodontitis and aggressive periodontitis patients. Among 12 patients, 6 were treated FMT and other 6 were treated PMT. Clinical parameters were calculated 3 months and 6 months after initial therapy. 1. There were no statistically significant differences between FMT and PMT in the reduction rate of bleeding on probing after 3 months, 6 months 2. Initial probing depth was 4-6mm, the mean probing depth after 3 months was 2.2mm vs 2.5mm(FMT vs PMT), after 6 months was 2.4mm vs 2.8mm. This was significantly lower in the FMT groups. 3. Initial probing depth was ${\geqq}$ 7mm, the reduction rate of mean probing depth during first 3 months was 4.8mm vs 4.1mm(FMT vs PMT), and 3 to 6 months was 0.5mm vs 0.3mm. This was significantly larger in the FMT groups. 4. Initial probing depth was 4-6mm, the mean clinical attachment level after 3 months was 2.3mm vs 2.7mm(FMT vs PMT), after 6 months was 2.7mm vs 3.0mm. This was significantly lower in the FMT groups. 5. Initial probing depth was ${\geqq}$ 7mm, the reduction rate of mean probing depth during first 3 months was 4.0mm vs 3.0mm(FMT vs PMT), and 3 to 6 months was 0mm vs -0.1mm. This was significantly larger in the FMT groups. Although the results provided us with succeccful clinical improvement in aggressive periodontitis, further research is needed to prove its additional benefit in the treatment of chronic periodontitis

Effects of the Guided Tissue Regeneration Using Polylactic/Polyglycolic Copolymer Membrane in the Furcation Involvement (Polylactic/Polyglycolic copolymer 차단막의 이개부 병소의 치유 효과)

  • Huh, Ji-Sun;Kim, Hyun-Young;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.2
    • /
    • pp.345-356
    • /
    • 2001
  • The purpose of the present study was to evaluate the clinical efficacy of guided tissue regeneration(GTR) using resorbable polylactic/polyglycolic copolymer(PLA/PGA) membrane in mandibular class II furcation involvement and to compare it to the clinical efficacy of only flap operation. Both procedures were conducted in 5 patients with class II furcation involvements. After 6 months of follow up, the probing pocket depth, clincial attachment level, bone probing depth, and radiographic changes were compared, and the following results were obtained: 1. GTR using PLA/PGA demonstrated a statistically significant reduction in probing pocket depth and bone probing depth, and the control group demonstrated a statistically significant reduction in bone probing depth. 2. The comparison between the experimental and control group failed to demonstrate statistically significant difference in clinical improvement, but more reduction in probing pocket depth and bone probing depth were observed in the experimental group. The probing pocket depth and the bone probing depth were $2.2{\pm}1.6mm$ and $2.4{\pm}1.1mm$ respectively in the control group, while they were $2.4{\pm}1.3mm$ and $3.0{\pm}1.2mm$ respectively in the experimental group. 3. Radiographic change was not detectable for the both groups during the 6 months of follow up. 4. Sites with deeper probing pocket depth at baseline examination showed greater amount of clinical improvement in both groups. Other clinical factors didn't have any significant effect on the treatment results. It is concluded that though there are some limitations, PLA/PGA membrane is effective for the treatment of mandibular class II furcation involvement.

  • PDF

Pre-Computation Based Selective Probing (PCSP) Scheme for Distributed Quality of Service (QoS) Routing with Imprecise State Information

  • Lee Won-Ick;Lee Byeong-Gi
    • Journal of Communications and Networks
    • /
    • v.8 no.1
    • /
    • pp.70-84
    • /
    • 2006
  • We propose a new distributed QoS routing scheme called pre-computation based selective probing (PCSP). The PCSP scheme is designed to provide an exact solution to the constrained optimization problem with moderate overhead, considering the practical environment where the state information available for the routing decision is not exact. It does not limit the number of probe messages, instead, employs a qualitative (or conditional) selective probing approach. It considers both the cost and QoS metrics of the least-cost and the best-QoS paths to calculate the end-to-end cost of the found feasible paths and find QoS-satisfying least-cost paths. It defines strict probing condition that excludes not only the non-feasible paths but also the non-optimal paths. It additionally pre-computes the QoS variation taking into account the impreciseness of the state information and applies two modified QoS-satisfying conditions to the selection rules. This strict probing condition and carefully designed probing approaches enable to strictly limit the set of neighbor nodes involved in the probing process, thereby reducing the message overhead without sacrificing the optimal properties. However, the PCSP scheme may suffer from high message overhead due to its conservative search process in the worst case. In order to bound such message overhead, we extend the PCSP algorithm by applying additional quantitative heuristics. Computer simulations reveal that the PCSP scheme reduces message overhead and possesses ideal success ratio with guaranteed optimal search. In addition, the quantitative extensions of the PCSP scheme turn out to bound the worst-case message overhead with slight performance degradation.

An Inference Method of Stateless Firewall Policy Considering Attack Detection Threshold (공격 탐지 임계값을 고려한 비상태기반 방화벽 정책 추론 방법)

  • Kim, Hyeonwoo;Kwon, Dongwoo;Ju, Hongtaek
    • Journal of Internet Computing and Services
    • /
    • v.16 no.2
    • /
    • pp.27-40
    • /
    • 2015
  • Inferring firewall policy is to discover firewall policy by analyzing response packets as results of active probing without any prior information. However, a brute-force approach for generating probing packets is unavailable because the probing packets may be regarded as attack traffic and blocked by attack detection threshold of a firewall. In this paper, we propose a firewall policy inference method using an efficient probing algorithm which considers the number of source IP addresses, maximum probing packets per second and interval size of adjacent sweep lines as inference parameters to avoid detection. We then verify whether the generated probing packets are classified as network attack patterns by a firewall, and present the result of evaluation of the correctness by comparing original firewall policy with inferred firewall policy.

The study of the peri-inplant soft tissue around osseointegrated implants in partial edentulous patients (하악 부분 무치악 환자의 골유착성 임플랜트 주위 연조직에 관한 연구)

  • Jung, Keun-Sik;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.561-573
    • /
    • 1997
  • The keratinized mucosa around the implant is an important key in health of soft tissue and hard tissue. The purpose of this study is showed that the keratinized mucosa is associated with the keratinized mucosa index, plaque index, gingival index, probing depth. which is investigated to observing the peri-implant mucosa of mandibular partial edentulous patuent using periodontal parameter by previously published paper. It was estimated 6 site with regard to 80 fixture for 28 person, and the average age is 46.8. Each estimation is the order of less trauma, that is, plaque index, keratinized mucosa index, gingival index and probing depth. In this study, statstically analyzed treatment is used for Spss V 7.0 for Windows(Spss Inc, USA). The Kruskal Walis Test is used to compare the amount of the keratinized mucosa is into the $0{\sim}3$ index, with plaque index, gingival index and probing depth. Mann-whitney Test is used to interpreate the relation of plaque index and probing depth, which is showed significant difference. The Result are as follows 1. The kertinized mucosa index 3 amounts to 47.7%, which is much higher than the other indices and the index order is followed 3, 1, 2 and O. 2. The plaque index 1 amounts to 61.7%, which is much higher than the other indices and the index order is followed 1, 2, 3 and O. The plaque index 0 is significant to each of index(P<0.05). The plaque index is decrease as the keratinized mucosa index is increased. 3. The probing depth for 2mm, 1mm, 3mm is 48.9%, 23.5%, 16.8% respectively, which is most occupied. The probing depth 2mm and 3mm for the keratinized mucosa index is significant(P<0.05). The probing index is decreased as the keratinized mucosa index is increased. 4. The gingival index 0 amounts to 58.0%, which is much higher than the other indices and the index order is followed 0, 1, 2 and 3.

  • PDF

Observation of Dynamic Movement of Probing Pin on PCB Pad Using Electrical Reliability Test (인쇄회로 기판의 전기검사에서의 미세 탐침과 패드의 동적 거동 현상 관측)

  • Song, Seongmin;Cha, Gangil;Kim, Myungkyu;Jeon, Seungho;Yu, SangSeok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.245-251
    • /
    • 2015
  • In an electrical reliability test of a printed circuit board (PCB), the impact of the micro probing pins on the PCB needs to be checked to ascertain the quality of the circuit. In this study, the impact of the dynamic movement of the probing pin on the pad was observed. As a misaligned pin can exert horizontal force on the pad of the PCB, this study focused on the behavior of a misaligned probing pin. The parameters of observation were the circular and flat edges of the probing pin. The effects of the speed of movement, diameter, and the length of projection of the probing pin were also investigated. The results demonstrated that slippage angle is strongly affected by the shape of the edge of the probing pin, and that projection length is an important factor affecting pin slippage. In contrast, the speed of movement of the probing pin was able to double the slippage angle.

An optical sensor of a probing system for inspection of PCBs (인쇄회로기판 검사용 프로브시스템의 광학센서)

  • 심재홍;조형석;김성권
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1742-1745
    • /
    • 1997
  • We have developed a highly responsible probing system for inspection of electrical properties of assemble PCB$_{s}$ (printed circuit boards). However, as the duration of the impact occurring between a probe and a solder joint on PCB is very short, it is very difficult to control the harmful peak impact force and the slip motion of the probe to sufficient level only by its vorce feedback control with high gains. To overcome these disadvantages of the prototype, it needs ot obtain some information of the solder joint in advance before the contact. In addition, to guarantee the reliability of the probing task, the probing system is required to measure several points around the probale target point at high speed. There fore, to meet such requirements, we propose a new noncontaet sensor capable of detecting simultaneously position and normal vectors of the multiple points around the probable target point in real time. By using this information, we can prepare a control strategy for stable contact motion on impact. In this paper, we described measuring priniciple, design, and development of the sensor. The effectiveness of the proposed sensor is verified through a series of experiments.s.

  • PDF

The Development of Near-field Probing Method on the Base Station Array Antenna (기지국 배열안테나의 근역장 프로빙 방법의 개발)

  • Lim, Gye-jae
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.1
    • /
    • pp.65-72
    • /
    • 2009
  • For the evaluation of far-field performance by using the near-field probing on the base station dipole array antenna, the effects of mutual coupling depending on the heights between the array antenna with reflector and the probe were analyzed. When the height is varied in the near-field region, S parameters on the input ports of antenna and probe are measured and analyzed to decide the height for the minimum mutual coupling effect and the maximum probing efficiency. This height will be applicable to the near-field probing system design to achieve the precision far-field performance of a base station array antenna system.

  • PDF

A Systematic Method of Probing Channel Characteristics of Home Power Line Communication Network for IP Based Control of Home Appliances (IP기반 가전 제어를 위한 전력선 통신망 채널 특성 추정기법에 관한 연구)

  • Ahn, Nam-Ho;Kim, Jung-Keun;Lee, Jae-Sik;Chang, Tae-Gyu;Kim, Hoon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.12
    • /
    • pp.696-701
    • /
    • 2003
  • This paper presents a systematic method of probing channel characteristics and communication reliabilities of home power line communication network applied to the Internet accessed control of home appliances. The effects of the three performance deterioating factors, i.e., additive noise, channel attenuation, and intersymbol interference, can be systematically measured by applying the channel probing waveform in the frequency range from 100KHz to 450KHz. Probability of bit error is derived with the probed channel parameters of the signal attenuation, noise and signal-to-interference ratio read in the frequency domain. The agreement between the derived probability of bit error and the measured probability of bit error supports the validity of the proposed approach of probing home power line channel characteristics. The experimental results performed with the constructed test-bed applying the proposed channel probing method also support the feasibility of commercially deploying the PLC modem installed home appliances and their services for the Internet accessed home automation.

SACK TCP with Probing Device

  • Liang, Bing;Hong, Choong Seon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.05a
    • /
    • pp.1355-1358
    • /
    • 2004
  • This paper describes a modification to the SACK (Selective Acknowledgement) Transmission Control Protocol's (TCP), called SACK TCP with Probing Device, SACK works in conjunction with Probing Device, for improving SACK TCP performance when more than half a window of data lost that is typical in handoff as well as unreliable media. It shows that by slightly modifying the congestion control mechanism of the SACK TCP, it can be made to better performance to multiple packets lost from one window of data.

  • PDF