• Title/Summary/Keyword: pressure sensitive

Search Result 793, Processing Time 0.027 seconds

Clinical study of blood flow and vascular reaction in Taeumin CVA patients using Transcranial Doppler (Transcranial Doppler를 이용(利用)한 태음인 중풍환자의 혈류속도(血流速度)와 혈관(血管) 반응성(反應性)에 대한 임상적(臨床的) 고찰(考察))

  • Lim, Jong-Pil;Bae, Na-Young;Han, Kyung-Soo;Ahn, Taek-Won
    • Journal of Haehwa Medicine
    • /
    • v.15 no.2
    • /
    • pp.263-272
    • /
    • 2006
  • Purpose Brain vessles have autoregulation function, so even when perfusion pressure drops, cerebral blood flow remain stable by vasodilation. Latest research on this reserve of cerebral vessels is being done using TCD, which measures the reserve of the vessels. We did a research comparing cerebral vessel and peripheral vessel reserve between Taeumin, who are more likely to suffer CVA, and the normal. We observed blood flow of Internal carotid artery siphon and radial indicis artery of the two group with TCD. Method We picked 20 people out of patients diagnosed as cerebral infarction at Cheon-An Oriental hospital of Daejeon University. They were diagnosed as Taeumin with QSCCII questionnaire and constitutional differentiation. Using TCD, we measured highest blood flow rate, mean blood flow and asymmetric counting blood flow of Internal carotid artery siphon and radial indicis artery at rest. And then we measured again after stimulating cerebral vessels, by triggering hypercapnia by self apnea and peripheral vessels by palm heating. Result At rest, mean blood flow rate of Internal carotid artery siphon showed significant decrease compared to control group. Blood flow rate of Internal carotid artery siphon after hypercapnia showed significant decline in highest blood flow rate and mean blood flow compared to control group. Cerebral vessel reaction after the hypercapnia induction showed great change in experiment group than the control group. Peripheral vessel reaction after palm heating showed significant decline in experiment group compared to control group. Conclusion In conclusion, measuring the alteration of blood flow used in diagnosing cerebral infarction, is more sensitive when vessel stimulation is done. Non-invasive TCD is effective especially in case of Taeumin who are more likely to suffer vascular disorder than others.

  • PDF

Property change of organic light-emitting diodes due to an ITO surface reformation (ITO 표면 개질에 의한 유기 발광 소자의 특성 변화)

  • Na, Su-Hwan;Joo, Hyun-Woo;An, Hui-Chul;Lee, Suk-Jae;Oh, Hyun-Suk;Min, Hang-Gi;Kim, Tae-Wan;Lee, Ho-Sik;Lee, Won-Jae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.411-412
    • /
    • 2008
  • We have studied a property change of organic light-emitting diodes (OLED) due to an indium tin oxide (ITO) surface reformation. The characteristics of OLED were improved by oxygen plasma processing of an ITO in this work. ITO is widely used as a transparent electrode in light-emitting devices, and the OLED device performance is sensitive to the surface properties of the ITO. The OLED devices with the structure of ITO/TPD(50nm)/$Alq_3$(70nm)/LiF(0.5nm)/Al(100nm) were fabricated, and the surface properties of ITO were investigated by using various characterization techniques. The oxygen plasma process of an ITO was processed by using RF power of 125W and oxygen partial pressure of $2\times10^{-2}$ Torr. The oxygen plasma processing of an ITO processed for 0/1/2/3/4min. Current-voltage-luminance characteristics of the devices show that turn-on voltage is 4V for 2min device and the luminance reaches about 27,000cd/$m^2$ for 4min device. The current efficiency shows that 3min device becomes saturated to be about 8cd/ A. They show that emission was from the $Alq_3$ layer, because the peak wavelength is about 525nm. View angle-dependent emission spectra show that the emission intensity decreases as the angle increases.

  • PDF

Development of Shading Tape for Manufacturing of Touch Panel Display with High Screen-to-Body Ratio (기기 면적 대비 높은 화면 비율을 갖는 터치 패널 디스플레이 제조를 위한 차광 테이프의 개발)

  • Kim, Ki-Chul
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.4
    • /
    • pp.75-81
    • /
    • 2017
  • The design trend of information technology is quickly changed with the times. The design trend of information display is a bezel-less display, recently. The bezel-less display or edge-less display is a new trend of mobile phone display. In this study, the shading tape was manufactured for assembling process of touch panel display with the high screen-to-body ratio so-called bezel-less display. The shading tape was fabricated on PET film with the UV curable acrylic pressure sensitive adhesive(PSA) by roll-to-roll process. The UV curable PSA was synthesized with the eco-friendly toluene-less manufacturing method. The adhesive power of manufactured shading tape was investigated by motorized tensile testing machine. The thixotropic, maintaining property of cutting shape, was characterized by field emission scanning electron microscope. As results, the shading tape exhibits high adhesive power and good thixotropic performance suitable for assembly process of touch panel display. The functional shading tape will be expected to improve productivity of assembly process of touch panel display.

A Study on the Hypotensive Action of Methanol Extract of Plantaginis Seed in the Rabbit (차전자 메탄올 엑기스의 혈압강하작용에 관한 연구)

  • 고석태;임동윤
    • YAKHAK HOEJI
    • /
    • v.22 no.3
    • /
    • pp.163-174
    • /
    • 1978
  • Plantaginis seed has been applied in Chinese medicine a as well as in folk remedy. It was advocated that Plantaginis S Semeη exerts good therapeutic effects as anti-inflammatory, antitussive, obstipant and diuretic agent in some cases of alimentary, respiratory a and renal disorders. This study was carried out in order to r re-evaluate the pharmacological action, especially the hypotensive a action of Plantaginis Semen and to elucidate the mechanism of its a action, making use of Plantaginis Semen methanol extract (PME), because its basic pharmacological action, i. e., hypotensive action is n not clear. 1) PME, when administered into intravenous route, elicited the h hypotensive response dependent on the dose of PME given to the rabbit anesthetized with urethane. 2) This hypotensive response of P PME was inhibited by atropine and potentiated by physostigmine, but not influ$\varepsilon$need by vagotomization. 3) Depressor effect of PME was blocked by chlorisondamine, phentolamine, and bethanicline, while not altered by cyproheptadine, diphenhydramine and propran¬olol. 4) The secondary pressor response after blocking the depressor e effect of PME by chlorisondamine was produced, but this pressor response was deminished by atropine. 5) PME augmented the pressor e effect of norepinephrine and angiotensin, on the other hand, reduced b blood pressure elevated by carotid occlusion reflex. 6) These observa¬t tions suggest that PME may induce the hypotensive response via dual mechanisms of parasympathomimetic and sympatholytic action, that the positions of this action are cholinergic peripheral site and sympathetic ganglia respectively, and that PME may possess the pressor activity caused by stimulation of "atropine-sensitive site" which seems to existsin the sympathetic ganglia.

  • PDF

Evaluation of Skin Absorption of Catechin from Topical Formulations Containing Korean Pine Bark Extract (Pinexol®) (국산 소나무껍질추출물(파인엑솔®)을 함유한 제제의 피부흡수 평가)

  • Choi, Joon-Ho;Choi, Min-Koo;Han, Ohan-Taek;Han, Sung-Jeong;Chung, Suk-Jae;Shim, Chang-Koo;Kim, Dae-Duk
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.6
    • /
    • pp.359-364
    • /
    • 2007
  • Pine bark extract is well-known as a very powerful antioxidant, anti-inflammatory, and antibiotic material. French maritime pine bark extract ($Pycnogenol^{(R)}$) of Horphag Research has monopolized the world market over 30 years. Korean red pine bark extract ($Pinexol^{(R)}$) was first manufactured by the patent technology of NutraPharm in Korea in 2006. Feasibility of topical gel and patch formulations of Pinexol was systematically investigated by evaluating the skin absorption of catechin as a reference compound. In vitro hairless mouse skin absorption of catechin from gel formulation was higher than that from patches. However, significant amount of catechin was also deposited inside the skin from patch formulations, which were dependent on the types of pressure sensitive adhesives. Thus, it seems to be feasible to control the topical delivery of Pinexol by using both gel and patch formulations, and be necessary to conduct further systematic investigation.

Degradation Behavior of Poly[(R)-3-hydroxybutyrate] by Using Single Crystals and Monolayers as Model Systems (단결정과 단분자막을 모델 시스템으로 한 Poly[(R)-3-hydroxybutyrate]의 분해거동)

  • Kim, Seong-Soo;Lee, Won-Ki;Ahn, Yong-Sik
    • Polymer(Korea)
    • /
    • v.29 no.1
    • /
    • pp.54-58
    • /
    • 2005
  • The hydrolytic behavior of microbial poly[(R)-3-hydroxybutyrate]](P(3HB)) has been studied by using two model systems, Langmuir monolayer and solution-grown single crystals (SCs), for elucidating the mechanism for both alkaline and enzymatic degradations. An initial degradation of SCs of P(3HB) leads to breakup lamellae parallel to their short axis (b-axis). Similarly, ridge formation on the lamellar surface appears along the b-axis at lower quenching temperature than melting temperature. Both results support that the lamellar crystals contain less-ordered and more thermally sensitive regions along the b-axis. Although the enzymatic hydrolysis of P(3HB) monolayers was similar to its alkaline one, the enzymatic degradation of P(3HB) monolayers occurred at higher constant surface pressure than the alkaline degradation. This behavior might be attributed to the size of enzymes which is much larger than that of alkaline ions; that is, the enzymes need larger contact area with monolayers to be activated.

Investigation of Characteristics of Passive Heat Removal System Based on the Assembled Heat Transfer Tube

  • Wu, Xiangcheng;Yan, Changqi;Meng, Zhaoming;Chen, Kailun;Song, Shaochuang;Yang, Zonghao;Yu, Jie
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1321-1329
    • /
    • 2016
  • To get an insight into the operating characteristics of the passive residual heat removal system of molten salt reactors, a two-phase natural circulation test facility was constructed. The system consists of a boiling loop absorbing the heat from the drain tank, a condensing loop consuming the heat, and a steam drum. A steady-state experiment was carried out, in which the thimble temperature ranged from $450^{\circ}C$ to $700^{\circ}C$ and the system pressure was controlled at levels below 150 kPa. When reaching a steady state, the system was operated under saturated conditions. Some important parameters, including heat power, system resistance, and water level in the steam drum and water tank were investigated. The experimental results showed that the natural circulation system is feasible in removing the decay heat, even though some fluctuations may occur in the operation. The uneven temperature distribution in the water tank may be inevitable because convection occurs on the outside of the condensing tube besides boiling with decreasing the decay power. The instabilities in the natural circulation loop are sensitive to heat flux and system resistance rather than the water level in the steam drum and water tank. RELAP5 code shows reasonable results compared with experimental data.

A Parameter Study on the Frequency Characteristics of the Structural-acoustic Coupled System (구조-음향 연성계의 경계값 변화에 따른 방사음 변화)

  • 김양한;서희선
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.7
    • /
    • pp.604-611
    • /
    • 2004
  • It is well known that wall impedance essentially determines how sound wave transmits from one place to another. The wall impedance is related with its dynamic properties : for example, the mass, stiffness, and damping characteristics. It is noteworthy, however, that the wall impedance is also function of spatial characteristics of two spaces that is separated by the wall. This is often referred that the wall is not locally reacting. In this paper, we have attempted to see how the acoustic characteristics of the two spaces is affected by various structure parameters such as density, applied tension, and a normalized length of the wall. Calculations are conducted for two different modally reacting boundary conditions by modal expansion method. The variation of the Helmholtz mode and the structural-dominated mode are analyzed as the structure parameters vary. The displacement distribution of the structure, pressure and active intensity of the inside and outside cavity are presented at the Helmholtz mode and the structure-dominated mode. It is shown that the frequency characteristics are governed by both structure-and fluid-dominated mode. The results exhibit that the density of the structure is the most sensitive design parameter on the frequency characteristics for the coupling system as we could imagine in the beginning. The Helmholtz mode frequency decrease as density increases. However. it increases as applied tension and an opening size increase. The bandwidth of the Helmholtz mode is mainly affected by density of the structure and its opening size.

Superhard SiC Thin Films with a Microstructure of Nanocolumnar Crystalline Grains and an Amorphous Intergranular Phase

  • Lim, Kwan-Won;Sim, Yong-Sub;Huh, Joo-Youl;Park, Jong-Keuk;Lee, Wook-Seong;Baik, Young-Joon
    • Corrosion Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.206-211
    • /
    • 2019
  • Silicon carbide (SiC) thin films become superhard when they have microstructures of nanocolumnar crystalline grains (NCCG) with an intergranular amorphous SiC matrix. We investigated the role of ion bombardment and deposition temperature in forming the NCCG in SiC thin films. A direct-current (DC) unbalanced magnetron sputtering method was used with pure Ar as sputtering gas to deposit the SiC thin films at fixed target power of 200 W and chamber pressure of 0.4 Pa. The Ar ion bombardment of the deposited films was conducted by applying a negative DC bias voltage 0-100 V to the substrate during deposition. The deposition temperature was varied between room temperature and $450^{\circ}C$. Above a critical bias voltage of -80 V, the NCCG formed, whereas, below it, the SiC films were amorphous. Additionally, a minimum thermal energy (corresponding to a deposition temperature of $450^{\circ}C$ in this study) was required for the NCCG formation. Transmission electron microscopy, Raman spectroscopy, and glancing angle X-ray diffraction analysis (GAXRD) were conducted to probe the samples' structural characteristics. Of those methods, Raman spectroscopy was a particularly efficient non-destructive tool to analyze the formation of the SiC NCCG in the film, whereas GAXRD was insufficiently sensitive.

Method development and validation of spectrophotometric and RP-HPLC methods for simultaneous estimation of spironolactone and furosemide in bulk and combined tablet dosage forms

  • Chavan, Rohankumar R.;Bhinge, Somnath D.;Bhutkar, Mangesh A.;Randive, Dheeraj S.;Salunkhe, Vijay R.
    • Analytical Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.212-224
    • /
    • 2021
  • The intent of the present work was to develop a simple, sensitive, accurate, precise, rapid and economical UV- spectrophotometric and reverse phase high pressure liquid chromatographic method for the simultaneous estimation of Spironolactone and Furosemide in bulk and combined tablet dosage forms. UV-Spectrophotometry was carried out by simultaneous equation method using 0.02 M potassium dihydrogen phosphate buffer pH 3.5: Acetonitrile (50:50) v/v as a solvent. The linearity range was 2-14 ㎍ mL-1 for Spironolactone and Furosemide with a correlation coefficient > 0.99. The chromatographic separation was achieved on 250 mm × 4.6 mm, hypersil BDS C18 column with particle size 5 ㎛, by using an isocratic mixture of 0.02 M potassium dihydrogen phosphate buffer pH 3.5: Acetonitrile: tert butyl methyl ether (49:50:1) v/v/v as a solvent at a flow rate of 1 mL min-1 and UV detection was carried out at 254 nm. The retention time were observed to be 3.666 and 6.661 minutes for Furosemide and Spironolactone respectively. The two developed methods were validated according to the ICH guidelines for accuracy, precision, linearity, LOD, LOQ and were found to be within the limits. It can be concluded that these two methods could be successfully used for the simultaneous estimation of Spironolactone and Furosemide in bulk and combined tablet dosage forms.