• 제목/요약/키워드: pressure chamber

검색결과 2,138건 처리시간 0.035초

혼합 유기용제 포집시 습도가 활성탄관의 파과에 미치는 영향 (Effect of Relative Humidity on the Breakthrough of Charcoal Tubes during Mixed Organic Vapor Sampling)

  • 양혁승;김현욱
    • 한국산업보건학회지
    • /
    • 제6권1호
    • /
    • pp.125-137
    • /
    • 1996
  • This study was designed to investigate effects of relative humidity on the breakthrough of charcoal tubes at a fixed vapor concentration and sampling time during mixed organic vapor sampling. A vapor generator was used to generate three different concentrations of mixed organic vapor and a stainless steel chamber was fabricated and utilized to maintain three different percentages of relative humidity while maintaining a constant temperature. The results were as follows; 1. At high relative humidity, breakthrough of mixed organic vapor occurred quickly at low vapor concentration than at high vapor concentration because of the reduced adsorption volume of charcoal tube due to humidity. 2. Breakthrough by competitive adsorption of vapors onto charcoal tube was observed at first from n-hexane having the lowest boiling point and highest vapor pressure among the three organic vapors investigated, followed by TCE. No breakthrough was observed from toluene under all experimental conditions. 3. For n-hexane, breakthrough was observed after 2 hours of sampling and breakthrough rates were increased as relative humidity increased. For TCE, breakthrough was found after 3 hours of sampling and breakthrough rates by sampling time were increased as vapor concentration increased. 4. The adsorbed amount of mixed organic vapor at breakthrough was shown to have statistically significant correlations with sampling time, relative humidity, and vapor concentration in descending order of correlation. Relative humidity and sampling time for n-hexane and sampling time and concentration for TCE were both statistically significantly correlated. 5. Relative humidity was found to affect the amount of breakthrough of mixed organic vapor and n-hexane. Among three percentages of relative humidity investigated, the amount of breakthrough at 85 % relative humidity was significantly larger than those of at lower percentages of relative humidity. No statistically significant difference was found between 25 % and 55 % relative humidity. 6. The results of multiple regression analysis between breakthrough and relative humidity, vapor concentrations showed that the coefficient of determination of mixed organic vapor was 0.263 and those of n-hexane and TCE were 0.275 and 0.189, respectively. 7. Flow rates of sampling pumps used were found to be affected by relative humidity present. At 25 %, 55 %, and 85 % relative humidity, the relative errors of sampling pump were 1.4 %, 13.4 %, and 18.6 %, respectively. In conclusion, the results of this study showed that high relative humidity could reduce the adsorption volume of charcoal tubes and subsequently increase breakthrough rates. Therefore, to prevent breakthrough when sampling mixed organic vapors, it is suggested that either sampling volume be reduced on the flow rate be lowered so as to minimize breakthrough of the most volatile organic vapor in the mixture. In addition, since the flow rates of a sampling pump can be adversely affected by high relative humidity, it is recommended to use a constant flow mode pump when sampling in the highly humid environment.

  • PDF

0.4 MW 급 분절형 아크 히터를 이용한 초음속 플라즈마 풍동 특성 실험 (Experimental Analysis of a Supersonic Plasma Wind Tunnel Using a Segmented Arc Heater with the Power Level of 0.4 MW)

  • 김민호;이미연;김정수;최채홍;서준호;문세연;홍봉근
    • 한국항공우주학회지
    • /
    • 제41권9호
    • /
    • pp.700-707
    • /
    • 2013
  • 0.4 MW 급 분절형 아크 히터를 장착한 전북대학교 플라즈마 풍동의 초음속 유동 특성 실험을 수행하고 그 결과를 분석하였다. 실험에 사용된 분절형 아크 히터와 초음속 노즐은 16.3 g/s 의 질량유량에 대해 전극 당 150 A, 전체 300 A의 입력전류 조건으로 운전되었으며, 운전 결과 350 kW의 입력전력과 약 51.4 %의 열효율이 계측되었다. 이 때, 아크 히터 내 고엔탈피 플라즈마의 내부압력은 약 4 bar 로 측정되었으며, 이를 초음속 노즐을 통해 압력 45 mbar로 유지되는 진공쳄버 내로 팽창시킴으로써, 전체 엔탈피 11 MJ/kg을 가진 초음속 플라즈마 유동을 얻을 수 있었다. 전체 엔탈피 측정과 함께, 생성된 초음속 플라즈마 유동에 대해 원뿔각 $30^{\circ}$를 가진 원뿔 탐침을 삽입하여 경사 충격파와 이루는 각을 측정하였으며, 이 측정값들로부터, 발생된 초음속 플라즈마의 온도와 마하 수는 각각 약 2,950 K 및 약 3.7에 이를 것으로 예상되었다.

토치 점화 장치의 체적에 따른 연소특성 파악 (Combustion Characteristics of Volume Variation of Torch in a CVCC)

  • 권순태;김형식;최창연;박찬준;엄인용
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2010년도 춘계학술 발표회
    • /
    • pp.166-170
    • /
    • 2010
  • 토치 점화 장치의 연소 특성을 파악하기 위하여 6개의 각기 다른 토치 점화 장치를 설계하였다. 토치 점화장치의 체적이 메탄의 연소특성에 미치는 영향을 파악하기 위하여, 토치점화 장치의 높이(h)와 오리피스 직경(De)는 10mm와 6mm로 고정하고, 입구 직경(D)을 12mm에서 22mm까지 2mm씩 증가시키며 토치 점화 장치를 설계하였다. 초기 화염 생성 및 전파는 질량 연소율과 연소 촉진율로 분석하였다. 질량 연소율과 연소 촉진율을 계산하기 위하여 정적 연소실 내의 평균 압력을 측정하였다. 또한 shadow graph법을 이용하여, 초기 화염 생성과 화염 전파과정 전 영역을 가시화하였다. 토치 점화 장치를 사용한 경우에는 일반적인 스파크 점화와 비교하여 질량 연소율의 기울기가 증가하였고, 연소 촉진율도 개선된것을 확인하였다. 토치 점화 장치의 체적이 증가할수록 연소가 개선되었으며, 넓은 점화 표면을 제공하였다.

  • PDF

PVC필터에 채취된 절삭유의 손실에 관한 연구 (Loss of Metalworking Fluids Collected on PVC Filter Due to Contact with Clean Air and Desiccation)

  • 박동욱;하권철
    • 분석과학
    • /
    • 제14권5호
    • /
    • pp.451-457
    • /
    • 2001
  • 절삭유(Metalworking Fludis, MWF) 노출로 인한 건강상의 장애는 암, 호흡기질환, 피부질환이다. MWF는 20여가지 이상의 화학물질이 혼합된 고분자의 화합물로서 상온에서 쉽게 증발되지 않는다. 이러한 특성으로 공기 중 MWF미스트의 측정과 분석은 PVC필터를 이용한 중량법이 국제적으로 공인되어 이용되고 있다. 그러나 사업장에서 MWF는 사용과정에서 분산되면 표면적이 커지고 증발하기 쉬운 상태로 된다. 본 연구는 실험실에서 MWF미스트 발생장치를 제작하여 MWF미스트가 필터에 채취되고 분석되는 과정에서 손실되는 양과 원인을 정량적으로 분석하였다. 즉 챔버에서 MWF가 채취된 PVC필터를 깨끗한 공기로 일정시간동안(10 ~ 240 분) 접촉하고 건조하여 각각의 과정(공기접촉, 건조기간)에서의 손실을 평가하였다. 공기와의 접촉 10분 후에 손실된 MWF양은 원래양의 12.4% - 21.8%였다. 전과정에서 손실된 양의 53.3%가 공기의 접촉초기에 일어나는 것을 확인하였다. PVC필터에 채취된 MWF의 손실은 건조과정에서 일어난 것을 확인하였다. PVC필터에 채취된 MWF의 손실에 영향을 미치는 요인을 분석하기 위한 다중회귀분석에서 MWF의 특성(사용중인 것과 사용하지 않는 것)이 유의한 예측변수였다. 이 연구 결과에 따르면, 국제적으로 공인된 증량법에 의한 공기중 MWF측정은 과소평가되는 것으로 판단된다.

  • PDF

Clinical Application of Endoscopic Inguinal Lymph Node Resection after Lipolysis and Liposuction for Vulvar Cancer

  • Wu, Qiang;Zhao, Yi-Bing;Sun, Zhi-Hua;Ni, Jing;Wu, Yu-Zhong;Shao, Heng-Hua;Qu, Jun-Wei;Huang, Xin-En
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권12호
    • /
    • pp.7121-7126
    • /
    • 2013
  • Aim: To examine lymph nodes obtained after lipolysis and liposuction of subcutaneous fat of the inguinal region of female vulvar cancer patients to explore the feasibility of clinical application. Methods: The field of operation was on the basis of the range of the conventional resection of inguinal lymph nodes. We injected lipolysis liquid fanwise, started liposuction after 15-20 minutes; then the subcutaneous fatty tissue was sucked out clearly by suction tube. We selected the first puncture holes located on 2-3 cm part below anterior superior spine, the others respectively being located 3cm and 6cm below the first for puncturing into the skin, imbedding a trocar to intorduce $CO_2$ gas and the specular body, and excise the lymph nodes by ultrasonic scalpel. The surgical field chamber was set with negative pressure drainage and was pressured with a soft saline bag after surgery. Results: A lacuna emerged from subcutaneous of the inguinal region after lipolysis and liposuction, with a wide fascia easily exposed at the bottom where lymph nodes could be readily excised. The number of lymph nodes of ten patients excised within the inguinal region on each side was 4-18. The excised average number of lymph nodes was 11 when we had mature technology. Conclusion: Most of adipose tissue was removed after lipolysis and liposuction of subcutaneous tissue of inguinal region, so that the included lymph nodes were exposed and easy to excise by endoscope. This surgery avoided the large incision of regular surgery of inguinal region, the results indicating that this approach is feasible and safe for used as an alternative technology.

국악음원의 방사특성을 고려한 국악원의 음향 성능 예측 (Prediction of the Acoustic Performance of a Music Hall Considering the Radiation Characteristics of Korean Traditional Musical Sources)

  • 정철호;이정권;연철호;한찬훈
    • 한국음향학회지
    • /
    • 제23권2호
    • /
    • pp.146-161
    • /
    • 2004
  • 기존의 국악원 설계에 있어서 국악음원의 음향 방사 특성을 고려하지 않아, 공연장의 음향목표설정 및 음향조정에 어려움이 있었다. 본 연구에서는 대표적인 국악 음원인 가야금 (현악기), 장고 (타악기), 대금 (관악기), 판소리 창 (성악) 등 4종에 대한 음향 방사 특성을 상세히 측정하여, 그 결과의 적용성을 살펴보았다. 음원을 반무향실의 중앙에 위치시키고, 매 10° 간격으로 음압 레벨을 측정함으로써 지향성을 파악하였다. 측정 결과, 가야금의 경우에는 주파수가 증가함에 따라 무지향성으로부터 지엽이 많아지는 형태로 순차적으로 지향성이 변하였다. 대금의 주요 방사방향은 위쪽이었고, 장고는 저주파수에서 왼쪽 지향성이 오른쪽보다 더 크게 나타난다. 창의 경우에는 주파수가 증가함에 따라 뒤쪽으로는 소리가 거의 전파되지 않는 지향성을 나타낸다. 측정된 국악음원의 지향성을 이용하여 건설중인 부산국립 국악원의 음향 인자들을 예측하였다. 대표적인 두 수음점 들에서 잔향시간, 음압 레벨, C80, LF, STI와 같은 주요 건축 음향 인자들이 음선 추적 기법에 의해 계산되었으며, 무지향성 음원과 국악 음원을 사용하였을 때 음향 인자들 사이에 큰 차이를 보였다. 본 연구에서 제시된 데이터와 설계 방법론 등은 향후 국악원의 설계에 있어서 기본적인 자료로 활용될 수 있다고 사료된다.

화강암 잔류 토양의 토양 가스 중 라돈의 장기적 변화 특성 (Long-term Variation of Radon in Granitic Residual Soil at Mt. Guemjeong in Busan, Korea)

  • 문기훈;김진섭;안정근;김현철;이효민
    • 암석학회지
    • /
    • 제18권4호
    • /
    • pp.279-291
    • /
    • 2009
  • 라돈은 원자번호 86의 화학원소로서 무색, 무취, 무미의 천연에서 존재하는 방사성 불활성기체이며 암석 및 토양 내 라듐의 방사능붕괴에 의해 생성되어, 주로 토양의 공극 중 가스 상태로 분포된다. 본 연구에서는 부산시 금정구의 금정산에 분포하는 화강암 잔류 토양에서 라돈 농도의 장기적 변화 특성과 이러한 변화에 영향을 미칠 수 있는 요인들로서 대기 온도, 강수, 토양 온 습도에 대한 영향을 분석하였다. 챔버와 튜브를 토양 내 설치하는 두 종류의 In-situ 모니터링 방식으로 토양 가스 내 라돈 농도를 정기적으로 측정하고, 그 효율성을 검토하였다. 토양 가스 중 라돈의 농도는 여름철에 가장 높게 측정되며, 겨울철에 가장 낮게 측정된다. 토양 내부 온도와 대기 온도의 변화가 이러한 라돈의 장기적 변화에 가장 크게 영향을 미치며, 양의 상관관계를 보인다. 대기 중 온도와 토양 내 온도 차에 의한 대기와 토양 내 공기의 순환이 주된 변화 요인으로 분석되었다. 그러나 다른 요인들(강수, 토양 습도)은 라돈 농도의 장기적 변화에 미치는 영향은 상대적으로 낮게 나타났다.

비냉각 금속 박막형 열전퇴 적외선 검지기 (Uncooled Metallic Thin-film Thermopile Infrared Detector)

  • 오광식;조현덕;김진섭;이용현;이종현;이정희;박세일
    • 대한전자공학회논문지SD
    • /
    • 제37권2호
    • /
    • pp.5-12
    • /
    • 2000
  • 열전퇴의 고온 접합부가 Si/sub 3/N/sub 4//SiO/sub 2//Si/sub 3/N/sub 4/ 멤브레인에 의해 실리콘 기판으로부터 열차단되고, 열전퇴의 저온 접합부는 방열판 역할을 하는 실리콘 림(rim)에 의해 지지되는 멤브레인위에 놓여지며, Au-black이 적외선 흡수체로 사용되는 비냉각 금속 박막형 열전퇴 적외선 검지기를 제작하고, 적외선 검지기의 성능지수에 대해 논의하였다. 3∼14㎛의 파장범위에서 Au-black의 적외선 흡수도는 대개 90%정도였고, Au 증발시의 챔버압력 및 증착된 Au-black의 단위면적당 질량에 크게 의존하였다. 쵸핑 주파수가 5 Hz일 때 Bi-Sb 열전퇴 적외선 검지기의 전압 감응도, 잡음등가전력 및 비검지도는 실온의 공기중에서 각각 약 10.5V/W, 2.3 ㎻/㎐½, 및 1.9×10/sup 7/㎝·㎐½/w였다.

  • PDF

수열합성법을 이용한 무기계 단열소재 제조방법 및 특성에 관한 연구 (2) (A Study on Fabrication and Characterization of Inorganic Insulation Material by Hydrothermal Synthesis Method (2))

  • 서성관;추용식;이종규;송훈;박재완
    • 한국건설순환자원학회논문집
    • /
    • 제1권3호
    • /
    • pp.225-232
    • /
    • 2013
  • 규석, 시멘트, 생석회 및 소량의 무수석고에 알루미늄 분말과 물을 첨가 혼합하여 오토클레이브 중에서 고온 고압 증기양생으로 미네랄 하이드레이트 소재를 제조하였다. 수열 합성된 미네랄 하이드레이트 소재는 균일한 세포조직을 갖는 다공질 경량 기포 콘크리트이다. 미네랄 하이드레이트 소재의 대표적인 특성으로는 다수의 기공으로 인해 뛰어난 경량성 및 단열성능을 들 수 있다. 제조된 미네랄 하이드레이트 소재의 특성은 각각 밀도 $0.26g/cm^3$, 압축강도 0.4MPa, 열전도율 0.064W/mK로 나타났다. 본 연구에서는 상기의 소재 특성을 증진시키기 위하여 "기포제의 종류 및 함량, 규석 및 시멘트의 입도 조건, 기능성 첨가제 종류 및 함량"에 따른 특성 평가 및 분석을 실시하였다. 그 결과 소재의 열적 특성을 개선할 수 있었으며, 특히 기능성 첨가제인 폴리디메틸실록산 혼화제를 첨가할 경우 밀도 및 열전도율을 개선하는 동시에 탁월한 강도 증진 효과를 나타내었다.

$BCl_3/Cl_2/Ar$ 고밀도 플라즈마에 의한 $(Ba, Sr)TiO_3$ 박막의 식각 메커니즘 연구 (A Study on the Etching Mechanism of $(Ba, Sr)TiO_3$ thin Film by High Density $BCl_3/Cl_2/Ar$ Plasma)

  • 김승범;김창일
    • 대한전자공학회논문지SD
    • /
    • 제37권11호
    • /
    • pp.18-24
    • /
    • 2000
  • (Ba,Sr)$TiO_3$ 박막은 ULSI-DRAM 즉 1-4 Gbit급 DRAM용 셀(cell) 커패시터의 새로운 유전물질로 각광받고 있다. 본 연구에서는 ICP 장비에서 $BCl_3/Cl_2/Ar$ 플라즈마로 (Ba,Sr)$TiO_3$ 박막을 식각하였다. 이때 RF power/dc bias voltage는 600W/-250V, 반응로의 압력은 10mTorr 이었다. $Cl_2/(Cl_2+Ar)$은 0.2로 고정하였고, $BCl_3$ 가스를 첨가하면서 (Ba,Sr)$TiO_3$ 박막을 식각하였다. $BCl_3$ 가스를 10% 첨가하였을 때, $480{\AA}/min$으로 (Ba,Sr)$TiO_3$ 박막은 가장 높은 식각 속도를 나타내었다. $Cl_2/Ar$가스에 $BCl_3$의 첨가 비에 따른 Cl, BCl 및 B의 라디칼 밀도를 optical emission spectroscopy(OES)에 의해 구하였다. $BCl_3$를 10% 첨가하였을 때 Cl의 라디칼 밀도가 가장 높았다. (Ba,Sr)$TiO_3$ 박막의 표면반응을 규명하기 위하여 XPS 분석을 수행한 결과 이온 bombardment 식각이 Ba-O 결합을 파괴하고 Ba와 Cl의 결합형태인 $BaCl_2$을 제거하기 위하여 필요하다. Sr과 Cl의 결합의 양은 많지 않고, Sr은 주로 물리적인 스퍼터링에 의하여 제거된다. Ti와 Cl은 화학적으로 반응하여 $TiCl_4$ 결합형태로 용이하게 제거된다. 식각후 단면사진을 SEM을 통해 본 결과 식각단면이 약 65~70$^{\circ}$ 정도였다.

  • PDF