Study on the Professionalism of Medical Technologists' Work in Health Examination Centers: Focusing on the General Health Examination (건강검진센터에서 임상병리사의 업무 전문성 연구: 일반건강검진을 중심으로)

  • Sung, Hyun Ho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.3
    • /
    • pp.271-277
    • /
    • 2020
  • "Health examinations" means medical examinations conducted by health examination institutions, including a physical examination, consultation, physical measurement, diagnostic laboratory test (also known as clinical laboratory test, clinical pathology test), pathology test, and Imaging test for checking the health condition and the prevention and early detection of diseases. The types of health examinations include general health examinations, comprehensive health examinations, special health examinations, and other health examinations. The proportion of the general health examination work of medical technologists working at health examination centers has been estimated to comprise more than 50% of the total work. The cost aspect of suspicious diseases can be estimated to be more than 25%. The cost of diagnostic laboratory test has been estimated to be approximately 5%, and the proportion of medical diagnosis use is 70%. The results show that it is time to revisit whether medical technologists are receiving appropriate social, economic, and reasonable policy treatment in health examination work. The future of medical technologists will further expand their professionalism in diagnostic laboratory test and quality control in precision medicine and telemedicine in the future. Therefore, medical technologists will need to participate proactively in government policy decisions related to national health examinations and make efforts to improve treatment.

Design of a Low Power Reconfigurable DSP with Fine-Grained Clock Gating (정교한 클럭 게이팅을 이용한 저전력 재구성 가능한 DSP 설계)

  • Jung, Chan-Min;Lee, Young-Geun;Chung, Ki-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.2
    • /
    • pp.82-92
    • /
    • 2008
  • Recently, many digital signal processing(DSP) applications such as H.264, CDMA and MP3 are predominant tasks for modern high-performance portable devices. These applications are generally computation-intensive, and therefore, require quite complicated accelerator units to improve performance. Designing such specialized, yet fixed DSP accelerators takes lots of effort. Therefore, DSPs with multiple accelerators often have a very poor time-to-market and an unacceptable area overhead. To avoid such long time-to-market and high-area overhead, dynamically reconfigurable DSP architectures have attracted a lot of attention lately. Dynamically reconfigurable DSPs typically employ a multi-functional DSP accelerator which executes similar, yet different multiple kinds of computations for DSP applications. With this type of dynamically reconfigurable DSP accelerators, the time to market reduces significantly. However, integrating multiple functionalities into a single IP often results in excessive control and area overhead. Therefore, delay and power consumption often turn out to be quite excessive. In this thesis, to reduce power consumption of dynamically reconfigurable IPs, we propose a novel fine-grained clock gating scheme, and to reduce size of dynamically reconfigurable IPs, we propose a compact multiplier-less multiplication unit where shifters and adders carry out constant multiplications.

Design and Implementation of Mobile Phone Interface Module for DGPS Correction Message Transmission (DGPS 보정신호 전송을 위한 휴대전화 인터페이스 모듈의 설계 및 구현)

  • Yi, Jae-hoon;Kim, Chang-Soo;Jeong, Seong-Hoon;Lee, Tae-Oh;Yun, Hee-Chul;Yim, Jae-Hong
    • Journal of Navigation and Port Research
    • /
    • v.26 no.4
    • /
    • pp.419-426
    • /
    • 2002
  • The conventional RTK-GPS technique has many problems which are permission using RF wireless modem, influence of geographic obstacle using radio wave, frequency interference, finiteness of frequency resources. To solve these problems, in this paper, we designed the DGPS correction message transmission system as a method to substitute the RF wireless modem of RTK-DGPS receiver. Then the interface module was designed and implemented for linkage of GPS receiver and mobile phone. As a result worked differential surveying using receiving correction message using RS-232C and communication control, users of mobile station were worked differential surveying correction between mobile phones. Interface module system was received the same result of precision which was compared RF wireless modem system.

Effects of Drying Methods Based on Exhaust Cycle and Time on the Quality and Drying of Red Peppers

  • Nam, Sang Heon;Ha, Yu Shin;Kim, Tae Wook
    • Journal of Biosystems Engineering
    • /
    • v.39 no.2
    • /
    • pp.101-110
    • /
    • 2014
  • Purpose: The purpose of this study is to develop a system to optimize drying potential energy of the exhausted hot air by changing relative humidity of the air. This study modified the conventional drying method into a drying method changing exhaust cycle and time in order to control the relative humidity of the exhausted hot air during drying process. Method: A valve on the vent was controlled according to a preset time to change the exhaust cycle and time. This study analyzed the influence of the two different types of drying method on the drying characteristics, required energy, and quality of the dried peppers: conventional drying method exhausting hot air continuously and new drying method controlling exhaust cycle and time. Results: Drying characteristics based on exhaust time showed that drying time increased with exhaust time, and specific energy consumption was reduced by 28% from 18.39 MJ/kg (conventional method) to 13.24 MJ/kg when exhaust time was set to one minute. Drying characteristics based on heating time showed that drying time increased with heating time and specific energy consumption was reduced by 30% from 18.39 MJ/kg (conventional method) to 12.87 MJ/kg when exhaust time was set to 22 minutes. Drying characteristics based on exhaust cycle showed that drying time increased with exhaust cycle, and specific energy consumption was reduced by 31% from 18.39 MJ/kg (conventional method) to 12.69 MJ/kg when exhaust time was set to one minute and exhaust cycle was set to 22 minutes before drying and 40 minutes after drying. The quality of the dried red peppers showed that capsaicin, color, and sugar content were high as 34.87 mg/100g, 66.33, and 11.87%, respectively, when exhaust time was set to one minute and exhaust cycle was set to 22 minutes before drying and 40 minutes after drying. Conclusions: In order to utilize the drying potential energy of the exhausted air during drying process, the conventional drying method was modified into the drying method controlling exhaust cycle and time. The results showed that drying with exhaust cycle of one minute was more efficient in terms of drying time, required energy, and quality of the dried peppers than the one with exhaust cycle of 20~40 minutes.

Classification and Comparative Analysis of the Contents of Acorus species and Anemone altaica by UPLC-PDA Analysis (UPLC-PDA를 이용한 창포류의 분류 및 함량 분석)

  • Jo, Ji Eun;Lee, A Yeong;Kim, Hyo Seon;Moon, Byeong Cheol;Ji, Yunui;Chun, Jin Mi;Kim, Ho Kyoung
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.279-284
    • /
    • 2013
  • A quantitative method using ultra performance liquid chromatography with a photodiode array detector (UPLCPDA) was established for the analysis of 2 major plant metabolites: ${\beta}$-asarone and ${\alpha}$-asarone from Acorus gramineus, A. tatarinowii, A. calamus and Anemone altaica, and their contents are compared with other herbs of Acorus species. The method was validated according to the International Conference on harmonization (ICH) guideline for validation of analytical procedures with respect to precision, accuracy, and linearity. The average content of ${\beta}$-asarone in Acorus gramineus was significantly higher than that in others, with the second highest concentration observed in A. tatarinowii, and only a trace amounts found in A. calamus and Anemone altaica. In contrast, the average content of ${\alpha}$-asarone in A. calamus was the highest, followed by that in Acorus gramineus and A. tatarinowii. principle component analysis (PCA) confirmed that ${\beta}$-asarone and ${\alpha}$-asarone content differed among the species. These results suggest that this UPLC-PDA method can be considered as good quality control criteria for Acorus gramineus.

Fabrication and characterization of $WSi_2$ nanocrystals memory device with $SiO_2$ / $HfO_2$ / $Al_2O_3$ tunnel layer

  • Lee, Hyo-Jun;Lee, Dong-Uk;Kim, Eun-Kyu;Son, Jung-Woo;Cho, Won-Ju
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.134-134
    • /
    • 2011
  • High-k dielectric materials such as $HfO_2$, $ZrO_2$ and $Al_2O_3$ increase gate capacitance and reduce gate leakage current in MOSFET structures. This behavior suggests that high-k materials will be promise candidates to substitute as a tunnel barrier. Furthermore, stack structure of low-k and high-k tunnel barrier named variable oxide thickness (VARIOT) is more efficient.[1] In this study, we fabricated the $WSi_2$ nanocrystals nonvolatile memory device with $SiO_2/HfO_2/Al_2O_3$ tunnel layer. The $WSi_2$ nano-floating gate capacitors were fabricated on p-type Si (100) wafers. After wafer cleaning, the phosphorus in-situ doped poly-Si layer with a thickness of 100 nm was deposited on isolated active region to confine source and drain. Then, on the gate region defined by using reactive ion etching, the barrier engineered multi-stack tunnel layers of $SiO_2/HfO_2/Al_2O_3$ (2 nm/1 nm/3 nm) were deposited the gate region on Si substrate by using atomic layer deposition. To fabricate $WSi_2$ nanocrystals, the ultrathin $WSi_2$ film with a thickness of 3-4 nm was deposited on the multi-stack tunnel layer by using direct current magnetron sputtering system [2]. Subsequently, the first post annealing process was carried out at $900^{\circ}C$ for 1 min by using rapid thermal annealing system in nitrogen gas ambient. The 15-nm-thick $SiO_2$ control layer was deposited by using ultra-high vacuum magnetron sputtering. For $SiO_2$ layer density, the second post annealing process was carried out at $900^{\circ}C$ for 30 seconds by using rapid thermal annealing system in nitrogen gas ambient. The aluminum gate electrodes of 200-nm thickness were formed by thermal evaporation. The electrical properties of devices were measured by using a HP 4156A precision semiconductor parameter analyzer with HP 41501A pulse generator, an Agillent 81104A 80MHz pulse/pattern generator and an Agillent E5250A low leakage switch mainframe. We will discuss the electrical properties for application next generation non-volatile memory device.

  • PDF

Growth and Anthocyanins of Lettuce Grown under Red or Blue Light-emitting Diodes with Distinct Peak Wavelength (상이한 피크파장의 적색광 및 청색광 발광다이오드 조사에 따른 상추의 생장 및 안토시아닌)

  • Lee, Jae Su;Kim, Yong Hyeon
    • Horticultural Science & Technology
    • /
    • v.32 no.3
    • /
    • pp.330-339
    • /
    • 2014
  • Growth and anthocyanins of lettuce (Lactuca sativa L., 'Mid-season') grown under LED lamps with blue light in the range of 430-470 nm or with red light in the range of 630-670 nm were analyzed in this study. Cool-white fluorescent light was used a s the control. P hotosynthetic photon flux, p hotoperiod, air temperature, relative humidity, and $CO_2$ concentration in a closed plant production system were $201{\pm}2\;{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, 16/8 hours (day/night), $22/18^{\circ}C$, 70%, and $400{\mu}mol{\cdot}mol^{-1}$, respectively. At 21 days after light quality treatment, growth characteristics and anthocyanins content of lettuce as affected by the peak wavelength of blue or red LED were significantly different. Among peak wavelengths treated in this stusy, R1 treatment (peak wavelength 634 nm) and R6 treatment (peak wavelength 659 nm) were effective for increasing leaf width, leaf area, shoot fresh weight, and photosynthetic rate of lettuce. B5 treatment (peak wavelength 450 nm) and B4 treatment (peak wavelength 446 nm) increased the anthocyanins concentration and chlorophyll content in lettuce leaves, respectively. Anthocyanins in lettuce leaves increased linearly with decreasing hue value of leaf color and with increasing SPAD value of lettuce leaves. From these results, it was concluded that the red LED with peak wavelengths of 634 nm and 659 nm and the blue LED with peak wavelengths of 450 nm can be used as potential light spectra for increasing the yield and anthocyanins accumulation of leafy vegetable.

Verification of Spatial Resolution in DMC Imagery using Bar Target (Bar 타겟을 이용한 DMC 영상의 공간해상력 검증)

  • Lee, Tae Yun;Lee, Jae One;Yun, Bu Yeol
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.30 no.5
    • /
    • pp.485-492
    • /
    • 2012
  • Today, a digital airborne imaging sensor plays an important role in construction of the numerous National Spatial Data Infrastructure. However, an appropriate quality assesment procedure for the acquired digital images should be preceded to make them useful data with high precision and reliability. A lot of studies therefore have been conducted in attempt to assess quality of digital images at home and abroad. In this regard, many test fields have been already established and operated to calibrate digital photogrammetric airborne imaging systems in Europe and America. These test fields contain not only GCPs(Ground Control Points) to test geometric performance of a digital camera but also various types of targets to evaluate its spatial and radiometric resolution. The purpose of this paper is to present a method to verify the spatial resolution of the Intergraph DMC digital camera and its results based on an experimental field testing. In field test, a simple bar target to be easily identified in image is used to check the spatial resolution. Images, theoretically designed to 12cm GSD(Ground Sample Distance), were used to calculate the actual resolution for all sub-images and virtual images in flight direction as well as in cross flight direction. The results showed that the actual image resolution was about 0.6cm worse than theoretically expected resolution. In addition, the greatest difference of 1.5cm between them was found in the image of block edge.

Validated HPLC Method for the Pharmacokinetic Study of Atenolol and Chlorthalidone Combination Therapy in Korean Subjects

  • Kang, Hyun-Ah;Kim, Hwan-Ho;Kim, Se-Mi;Yoon, Hwa;Cho, Hea-Young;Oh, Seaung-Youl;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.5
    • /
    • pp.331-338
    • /
    • 2006
  • A rapid, selective and sensitive reverse-phase HPLC methods for the determination of atenolol and chlorthalidone in human serum and whole blood were validated, and applied to the pharmacokinetic study of atenolol and chlorthalidone combination therapy. Atenolol and an internal standard, pindolol, were extracted from human serum by liquid-liquid extraction, and analyzed on a $\mu$-Bondapak C18 $10-{\mu}$ column in a mobile phase of methanol-0.01 M potassium dihydrogenphosphate(30:70, v/v, adjusted to pH 3.5) and fluorescence detection(emission: 300 nm, excitation: 224 nm). Chlorthalidone and an internal standard, probenecid, were extracted form human whole blood by liquid-liquid extraction, and analyzed on a Luna C18 $5-{\mu}$ column in a mobile phase of acetonitrile containing 77% 0.01 M sodium acetate and UV detection at 214 nm. These analysis were performed at three different laboratories using the same quality control(QC) samples. The chromatograms showed good resolution, sensitivity, and no interference by human serum and whole blood, respectively. The methods showed linear responses over a concentration range of 10-1,000 ng/mL for atenolol and 0.05-20 ${\mu}g/mL$ for chlorthalidone, with correlation coefficients of greater than 0.999 at all the three laboratories. Intra- and inter-day assay precision and accuracy fulfilled international requirements. Stability studies(freeze-thaw, short-, long-term, extracted sample and stock solution) showed that atenolol and chlorthalidone were stable. The lower limit of quantitation of atenolol and chlorthalidone were 10 ng/mL and 0.05 ${\mu}g/mL$, respectively, which was sensitive enough for pharmacokinetic studies. These methods were applied to the pharmacokinetic study of atenolol and chlorthalidone in human volunteers following a single oral administration of Hyundai $Tenoretic^{\circledR}$ tablet(atenolol 50 mg and chlorthalidone 12.5 mg) at three different laboratories.

Simultaneous Determination of Pesticides in Water Using a GC/MS Coupled with Micro Extraction by Packed Sorbent (MEPS-GC/MS를 이용한 농약류 동시 수질분석)

  • Lee, Ki-chang;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.5
    • /
    • pp.262-268
    • /
    • 2015
  • This study established an analytical method to simultaneously determine six organophosphorous pesticides [methyldemetone-S, diazinon, fenitrothion, parathion, phentoate, and O-ethyl O-(4-nitrophenyl) phenylphosphonothioate (EPN)] and carbaryl in water using a gas chromatography/mass spectrometry (GC/MS) system coupled with on-line micro extraction by packed sorbent (MEPS) and programmed temperature vaporizer (PTV) injector. Polystyrene divinylbenzene (PDVB) was used as a sorbent of MEPS. The effects of elution solvents, pH, elution volume and draw-eject cycles of samples on sample pretreatment process were investigated. Also, quality assurance and quality control (QA/QC) and the recovery of the pesticides in environmental samples were evaluated. The elution was performed using $30{\mu}L$ of a mixed solvent (acetone : dichloromethane = 80 : 20 (v/v)). Sample pretreatment processes were optimized with seven cycles of draw-eject of sample (1 mL) spiking an internal standard and sulfuric acid. At lower pH, the analytical sensitivity of diazinon decreased, but that of carbaryl increased. The method detection limit and the limit of quantification for this method were 0.02~0.18 and $0.08{\sim}0.59{\mu}g/L$, respectively. The method precision and accuracy were 1.5~11.5% and 83.3~129.8%, respectively, at concentrations of $0.5{\sim}5.0{\mu}g/L$. The recovery rates for all the pesticides except carbaryl in various environmental samples ranged 75.7~129.3%. The recovery rate of carbaryl in effluent sample was over 200% whereas carbaryl in drinking water, groundwater, and river water were in the acceptable range.