• Title/Summary/Keyword: precession

Search Result 103, Processing Time 0.031 seconds

The Spin State of NPA Rotator (5247) Krylov

  • Lee, Hee-Jae;Durech, Josef;Kim, Myung-Jin;Moon, Hong-Kyu;Kim, Chun-Hwey;Park, Jintae;Kim, Dong-Heun;Roh, Dong-Goo;Choi, Young-Jun;Yim, Hong-Suh;the DEEP-South Team
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.50.1-50.1
    • /
    • 2017
  • The Non-Principal Axis (NPA) rotators can be clues to spin evolutionary processes of asteroids because their excited spin states evolve due to either internal or external forces. The NPA rotation of (5247) Krylov was confirmed by Lee et al. (2017) based on KMTNet photometric observations during the 2016 apparition. We conducted follow-up observations in 2017 apparition using the 0.6-2.1m telescopes in the northern hemisphere to determine the spin state and shape model of this asteroid. We found that it is rotating in the Short Axis Mode (SAM) based on the determined rotation period ($P_{\psi}=374.6hr$) and precession period ($P_{\phi}=67.48hr$). The greatest and intermediate principal inertia moments are nearly the same as $I_b/I_c=0.94$, but the smallest principal inertia moments are nearly half that of the others, $I_a/I_c=0.43$. This ratio of principal inertia moments suggests that dynamically equivalent shape of this asteroid is close to that of a prolate ellipsoid. In this presentation, we will provide the physical model of (5247) Krylov to discuss its possible spin evolutionary processes that acted on its spin.

  • PDF

Application of Data Mining Techniques to Explore Predictors of HCC in Egyptian Patients with HCV-related Chronic Liver Disease

  • Omran, Dalia Abd El Hamid;Awad, AbuBakr Hussein;Mabrouk, Mahasen Abd El Rahman;Soliman, Ahmad Fouad;Aziz, Ashraf Omar Abdel
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.1
    • /
    • pp.381-385
    • /
    • 2015
  • Background:Hepatocellular carcinoma (HCC) is the second most common malignancy in Egypt. Data mining is a method of predictive analysis which can explore tremendous volumes of information to discover hidden patterns and relationships. Our aim here was to develop a non-invasive algorithm for prediction of HCC. Such an algorithm should be economical, reliable, easy to apply and acceptable by domain experts. Methods: This cross-sectional study enrolled 315 patients with hepatitis C virus (HCV) related chronic liver disease (CLD); 135 HCC, 116 cirrhotic patients without HCC and 64 patients with chronic hepatitis C. Using data mining analysis, we constructed a decision tree learning algorithm to predict HCC. Results: The decision tree algorithm was able to predict HCC with recall (sensitivity) of 83.5% and precession (specificity) of 83.3% using only routine data. The correctly classified instances were 259 (82.2%), and the incorrectly classified instances were 56 (17.8%). Out of 29 attributes, serum alpha fetoprotein (AFP), with an optimal cutoff value of ${\geq}50.3ng/ml$ was selected as the best predictor of HCC. To a lesser extent, male sex, presence of cirrhosis, AST>64U/L, and ascites were variables associated with HCC. Conclusion: Data mining analysis allows discovery of hidden patterns and enables the development of models to predict HCC, utilizing routine data as an alternative to CT and liver biopsy. This study has highlighted a new cutoff for AFP (${\geq}50.3ng/ml$). Presence of a score of >2 risk variables (out of 5) can successfully predict HCC with a sensitivity of 96% and specificity of 82%.

Assessment of Left Ventricular Function with Single Breath-Hold Magnetic Resonance Cine Imaging in Patients with Arrhythmia

  • Bak, So Hyeon;Kim, Sung Mok;Park, Sung-Ji;Kim, Min-Ji;Choe, Yeon Hyeon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: To evaluate quantification results of single breath-hold (SBH) magnetic resonance (MR) cine imaging compared to results of conventional multiple breath-hold (MBH) technique for left ventricular (LV) function in patients with cardiac arrhythmia. Materials and Methods: MR images of patients with arrhythmia who underwent MBH and SBH cine imaging at the same time on a 1.5T MR scanner were retrospectively reviewed. Both SBH and MBH cine imaging were performed with balanced steady state free precession. SBH scans were acquired using temporal parallel acquisition technique (TPAT). Fifty patients ($65.4{\pm}12.3years$, 72% men) were included. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), myocardial mass, and LV regional wall motion were evaluated. Results: EF, myocardial mass, and regional wall motion were not significantly different between SBH and MBH acquisition techniques (all P-values > 0.05). EDV, ESV, and SV were significant difference between the two techniques. These parameters for SBH cine imaging with TPAT tended to lower than those in MBH. EF and myocardial mass of SBH cine imaging with TPAT showed good correlation with values of MBH cine imaging in Passing-Bablok regression charts and Bland-Altman plots. However, SBH imaging required significantly shorter acquisition time than MBH cine imaging ($15{\pm}7sec$ vs. $293{\pm}104sec$, P < 0.001). Conclusion: SBH cine imaging with TPAT permits shorter acquisition time with assessment results of global and regional LV function comparable to those with MBH cine imaging in patients with arrhythmia.

Gate-Controlled Spin-Orbit Interaction Parameter in a GaSb Two-Dimensional Hole gas Structure

  • Park, Youn Ho;Koo, Hyun Cheol;Shin, Sang-Hoon;Song, Jin Dong;Kim, Hyung-Jun;Chang, Joonyeon;Han, Suk Hee;Choi, Heon-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.382-383
    • /
    • 2013
  • Gate-controlled spin-orbit interaction parameter is a key factor for developing spin-Field Effect Transistor (Spin-FET) in a quantum well structure because the strength of the spin-orbit interaction parameter decides the spin precession angle [1]. Many researches show the control of spin-orbit interaction parameter in n-type quantum channels, however, for the complementary logic device p-type quantum channel should be also necessary. We have calculated the spin-orbit interaction parameter and the effective mass using the Shubnikov-de Haas (SdH) oscillation measurement in a GaSb two-dimensional hole gas (2DHG) structure as shown in Fig 1. The inset illustrates the device geometry. The spin-orbit interaction parameter of $1.71{\times}10^{11}$ eVm and effective mass of 0.98 $m^0$ are obtained at T=1.8 K, respectively. Fig. 2 shows the gate dependence of the spin-orbit interaction parameter and the hole concentration at 1.8 K, which indicates the spin-orbit interaction parameter increases with the carrier concentration in p-type channel. On the order hand, opposite gate dependence was found in n-type channel [1,2]. Therefore, the combined device of p- and n-type channel spin transistor would be a good candidate for the complimentary logic device.

  • PDF

Effect of Energy Barrier Distribution on Current-Induced Magnetization Switching with Short Current Pulses (짧은 전류 펄스를 이용한 전류 유도 자화 반전에서 에너지 장벽 분포의 효과)

  • Kim, Woo-Yeong;Lee, Kyung-Jin
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.2
    • /
    • pp.48-51
    • /
    • 2011
  • We performed macro-spin simulation studies of the current-induced magnetization reversal of nanomagnetic elements with short current pulses. A special attention was paid to the effect of the energy barrier on the switching current distribution. The switching current and its distribution increase with decreasing the current pulse-width. The relationship between the energy barrier and switching current distribution is described by the Arrhenius-N$\'{e}$el law at a long pulse-width regime. At a regime of short pulse-width, however, the relationship is left unaddressed. The difficulty to address this issue arises because the magnetization switching with a short current pulse is governed not by the thermal activation but by the precession motion. Therefore, an exact formulation for the short pulse regime by solving the Fokker-Plank equation is needed to understand the result.

Real-time Parallel Processing Simulator for Modeling Portable Missile System and Performance Analysis (휴대용 유도탄 체계의 모델링과 성능분석을 위한 실시간 병렬처리 시뮬레이터)

  • Kim Byeong-Moon;Jung Soon-Key
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.4 s.42
    • /
    • pp.35-45
    • /
    • 2006
  • RIn this paper. we describe real-time parallel processing simulator developed for the use of performance analysis of rolling missiles. The real-time parallel processing simulator developed here consists of seeker emulator generating infrared image signal on aircraft, real-time computer, host computer, system unit, and actual equipments such as auto-pilot processor and seeker processor. Software is developed according to the design requirements of mathematic model, 6 degree-of-freedom module, aerodynamic module which are resided in real-time computer. and graphic user interface program resided in host computer. The real-time computer consists of six TI C-40 processors connected in parallel. The seeker emulator is designed by using analog circuits coupled with mechanical equipments. The system unit provides interface function to match impedance between the components and processes very small electrical signals. Also real launch unit of missiles is interfaced to simulator through system unit. In order to use the real-time parallel processing simulator developed here as a performance analysis equipment for rolling missiles, we perform verification test through experimental results in the field.

  • PDF

Muscle Functional MRI of Exercise-Induced Rotator Cuff Muscles

  • Tawara, Noriyuki;Nishiyama, Atsushi
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.1
    • /
    • pp.1-9
    • /
    • 2021
  • The aim of this study was to provide a new assessment of rotator cuff muscle activity. Eight male subjects (24.7 ± 3.2 years old,171.2 ± 9.8 cm tall, and weighing 63.8 ± 11.9 kg) performed the study exercises. The subjects performed 10 sets of the exercise while fixing the elbow at 90 degrees flexure and lying supine on a bed. One exercise set consisted of the subject performing external shoulder rotation 50 times using training equipment. Two imaging protocols were employed: (a) true fast imaging with steady precession (TrueFISP) at an acquisition time of 12 seconds and (b) multi-shot spin-echo echo-planar imaging (MSSE-EPI) at an acquisition time of 30 seconds for one echo. The main method of assessing rotator cuff muscle activity was functional T2 mapping using ultrafast imaging (fast-acquired muscle functional MRI [fast-mfMRI]). Fast-mfMRI enabled real-time imaging for the identification and evaluation of the degree of muscle activity induced by the exercise. Regions of interest were set at several places in the musculus subscapularis (sub), musculus supraspinatus (sup), musculus teres minor (ter), and deltoid muscle (del). We used the MR signal of the images and transverse relaxation time (T2) for comparison. Most of the TrueFISP signal was not changed by exercise and there was no significant difference from the resting values. Only the T2 in the musculus teres minor was increased after one set and the change were seen on the T2 images. Additionally, except for those after one and two sets, the changes in T2 were significant compared to those at rest (P < 0.01). We also demonstrated identify and visualize the extent to which muscles involved in muscle activity by exercise. In addition, we showed that muscle activity in a region such as a shoulder, which is susceptible to B0 inhomogeneity, could be easily detected using this technique.

Effect of posterior span length on the trueness and precision of 3 intraoral digital scanners: A comparative 3-dimensional in vitro study

  • Fattouh, Mohamed;Kenawi, Laila Mohamed Mohamed;Fattouh, Hesham
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.399-406
    • /
    • 2021
  • Purpose: This in vitro study measured and compared 3 intraoral scanners' accuracy (trueness and precision) with different span lengths. Materials and Methods: Three master casts were prepared to simulate 3 different span lengths (fixed partial dentures with 3, 4, and 5 units). Each master cast was scanned once with an E3 lab scanner and 10 times with each of the 3 intraoral scanners (Trios 3, Planmeca Emerald, and Primescan AC). Data were stored as Standard Tessellation Language (STL) files. The differences between measurements were compared 3-dimensionally using metrology software. Data were analyzed using 1-way analysis of variance with post hoc analysis by the Tukey honest significant difference test for trueness and precision. Statistical significance was set at P<0.05. Results: A statistically significant difference was found between the 3 intraoral scanners in trueness and precision (P<0.05). Primescan AC showed the lowest trueness and precision values(36.8 ㎛ and 42.0 ㎛;(39.4 ㎛ and 51.2 ㎛; and 54.9 ㎛ and 52.7 ㎛) followed by Trios 3 (38.9 ㎛ and 53.5 ㎛; 49.9 ㎛ and 59.1 ㎛; and 58.1 ㎛ and 64.5 ㎛) and Planmeca Emerald (60.4 ㎛ and 63.6 ㎛; 61.3 ㎛ and 69.0 ㎛; and 70.8 ㎛ and 74.3 ㎛) for the 3-unit, 4-unit, and 5-unit fixed partial dentures, respectively. Conclusion: Primescan AC had the best trueness and precision, followed by Trios 3 and Planmeca Emerald. Increasing span length reduced the trueness and precession of the 3 scanners; however, their values were within the accepted successful ranges.

Dating Sun's Locations at Equinoxes Inscribed on Cheonsang Yeolcha Bunyajido

  • Sang-Hyeon Ahn
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.2
    • /
    • pp.201-212
    • /
    • 2023
  • The inscription of Cheonsang Yeolcha Bunyajido (天象列次分野之圖) has the sun's locations at the equinoxes, which must have been copied from the astronomical treatises in Chinese historical annals, Songshu (宋書) and Jinshu (晉書). According to the treatises, an astronomer Wang Fan (王蕃, 228-266 CE) referred those values from a calendrical system called Qianxiangli (乾象曆, 223 CE), from which it is confirmed that it adopted the sun's location at the winter solstice of the $(21{\frac{1}{4}})^{th}$ du of the 8th lunar lodge Dou (斗) as the reference direction for equatorial lodge angles. This indicates that the sun's locations at equinoxes and solstices in the calendrical system are the same as those in Jingchuli (景初曆, 237 CE). Hence, we propose that the sun's location at the autumnal equinox in Cheonsang Yeolcha Bunyajido should be corrected from 'wu du shao ruo' (五度少弱), meaning the $(5{\frac{1}{6}})^{th}$ du, to 'wu du ruo' (五度弱), meaning the $(4{\frac{11}{12}})^{th}$ du, of the first lunar lodge Jiao (角), as seen in Jingchuli. We reconstruct the polar coordinate system used in circular star charts, assuming that the mean motion rule was applied and its reference direction was the sun's location at the winter solstice. Considering the precession, we determined the observational epoch of the sun's location at the winter solstice to be to = -18.3 ± 43.0 adopting the observational error of the so-called archaic determinatives (古度). It is noteworthy that the sun's locations at equinoxes inscribed in Cheonsang Yeolcha Bunyajido originated from Houhan Sifenli (後漢 四分曆) of the Latter Han dynasty (85 CE), while the coordinate origin in the star chart is related to Taichuli (太初曆) of the Former Han dynasty (104 BCE).

In Vivo and In Vitro Studies of the Steady State Free Precession-Diffusion-Weighted MR Imagings on Low b-value : Validation and Application to Bone Marrow Pathology

  • Byun, Woo-Mok
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.119-128
    • /
    • 2007
  • Purpose : The purpose of this study was a phantom study to measure the diffusion properties of water molecules by steady-state free precession diffusion-weighted imaging (SSFP- DWI) with a low b-value and to determine if this sequence might be useful for application to the evaluation of bone marrow pathology. Materials and methods : 1. The phantom study: A phantom study using two diffusion weighted sequences for the evaluation of the diffusion coefficient was performed. Three water-containing cylinders at different temperatures were designed: phantom A was $3^{\circ}C$, B was $23^{\circ}C$ and C was $63^{\circ}C$. Both SSFP and echo planar imaging (EPI) sequences (b-value: $1000s/mm^2$) were performed for comparison of the diffusion properties. The Signal to noise ratios (SNR) and apparent diffusion coefficient (ADC) values of the three phantoms using each diffusion-weighted sequence were assessed. 2. The Clinical study: SSFP-DWI was performed in 28 patients [sacral insufficiency fractures (10), osteoporotic lumbar compression fractures (10), malignant compression fractures (8)]. To measure the ADC maps, a diffusion-weighted single shot stimulated echo-acquisition mode sequence ($650s/mm^2$) was obtained using the same 1.5-T MR imager Results : For the phantom study, the signal intensity on the SSFP as well as the classic EPI-based DWI was decreased as the temperature increased in phantom A to C. The ADC values of the phantoms on EPI-DWI were $0.13{\times}10^{-3}mm^2/s$ in phantom A, $0.22{\times}10^{-3}mm^2/s$ in B and $0.37{\times}10^{-3}mm^2/s$. in C. The SSFP can be regarded as a DWI sequence in view of the series of signal decreases. Conclusion : Bone marrow pathologies with different diffusion coefficients were evaluated by SSFP-DWI. All benign fractures were hypointense compared to the adjacent normal bone marrow where as the malignant fractures were hyperintense compared to the adjacent normal bone marrow.

  • PDF