• 제목/요약/키워드: power source

검색결과 5,840건 처리시간 0.029초

전류원 PWM 컨버터 / 인버터를 이용한 새로운 단조용 유도가열 전원장치의 설계 (Design of New Induction Heating Power Supply for Forging Applications Using Current-Source PWM Converter and Inverter)

  • 최승수;이창우;김인동
    • 전기학회논문지
    • /
    • 제67권12호
    • /
    • pp.1602-1610
    • /
    • 2018
  • Induction heating can convert electrical energy to thermal energy with high conversion efficiency and quick heating. Currently, a current source rectifier/inverter-fed parallel resonant circuit is widely used as an induction heating power supply for forging applications. However, the conventional induction heating power supplies composed of phase-controlled rectifier and SCR inverter have low efficiency and low power factor at input side, and require additional starting circuitry. So this paper proposes new induction heating power supply topologies for forging applications which have high power factor, high efficiency, and large output power. It also suggests detailed design guideline.

New Resonant AC Link Snubber-Assisted Three-Phase Soft-Switching PWM Inverter and Its Comparative Characteristics Evaluations

  • Yoshida, Masanobu;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제3권4호
    • /
    • pp.239-248
    • /
    • 2003
  • This paper presents a novel prototype of three-phase voltage source type zero voltage soft-switching inverter with the auxiliary resonant snubbers suitable for high-power applications with IGBT power module packages in order to reduce their switching power losses as well as electromagnetic conductive and radiative noises. A proposed single inductor-assisted resonant AC link snubber circuit topology as one of some auxiliary resonant commutation snubbers developed previously to achieve the zero voltage soft-switching (ZVS) for the three-phase voltage source type sinewave PWM inverter operating under the instantaneous space voltage vector modulation is originally demonstrated as compared with the other types of resonant AC link snubber circuit topologies. In addition to this, its operation principle and unique features are described in this paper. Furthermore, the practical basic operating performances of the new conceptual instantaneous space voltage vector modulation resonant AC link snubber-assisted three-phase voltage source type soft-switching PWM inverter using IGBT power module packages are evaluated and discussed on the basis of switching voltage and current waveforms, output line to line voltage quality, power loss analysis, actual power conversion efficiency and electromagnetic conductive and radiative noises from an experimental point of view, comparing with those of conventional three-phase voltage source hard-switching PWM inverter using IGBT power modules.

계통측에서 본 풍력발전단지 도입에 따른 해결과제 및 대책연구 (Problem and Solution of Wind Farm based on Distribution Power system)

  • 윤기갑;박상만;허엽;정상봉;김홍필;이승학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.488-490
    • /
    • 2001
  • A dispered power system means a little bit of small power generation equipment located near the power-damend areas. Due to no power supply line, such a power source is very favorable for the decrease in loss of electric power supply, in comparison to the giantly focused power source, Because of small power source, this power source also corresponds promptly to the variation of power demend. On the basis of energy saving, environmental reservation, and utilization of natural or unused energy, solar power plants can be introduced into the residence section of cities and small water or wind-power plants near the urban areas. In case of Korea, some wind farm have been introduced into Cheju island, Condensed introduction of several small power sources into an used distribution line may, however, result in a big problem, it is, therefore, necessary that protective-cooporative plans between power quality and distribution line should be introduced for efficient utilization of KEPCO distribution system.

  • PDF

INTEGRATED SOCIETAL RISK ASSESSMENT FRAMEWORK FOR NUCLEAR POWER AND RENEWABLE ENERGY SOURCES

  • LEE, SANG HUN;KANG, HYUN GOOK
    • Nuclear Engineering and Technology
    • /
    • 제47권4호
    • /
    • pp.461-471
    • /
    • 2015
  • Recently, the estimation of the social cost of energy sources has been emphasized as various novel energy options become feasible in addition to conventional ones. In particular, the social cost of introducing measures to protect power-distribution systems from power-source instability and the cost of accident-risk response for various power sources must be investigated. To account for these risk factors, an integrated societal risk assessment framework, based on power-uncertainty analysis and accident-consequence analysis, is proposed. In this study, we applied the proposed framework to nuclear power plants, solar photovoltaic systems, and wind-turbine generators. The required capacity of gas-turbine power plants to be used as backup power facilities to compensate for fluctuations in the power output from the main power source was estimated based on the performance indicators of each power source. The average individual health risk per terawatt-hours (TWh) of electricity produced by each power source was quantitatively estimated by assessing accident frequency and the consequences of specific accident scenarios based on the probabilistic risk assessment methodology. This study is expected to provide insight into integrated societal risk analysis, and can be used to estimate the social cost of various power sources.

성능함수를 이용한 직렬형 능동전력필터의 제어알고리즘에 관한 연구 (A Study of Control Algorithm For Series Active Power Filter Using Performance Function)

  • 고수현;김진선;김영석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.199-202
    • /
    • 2002
  • This paper suggests the control algorithm of a 3-phase 3-wire series active power filters which have harmonic voltage source and harmonic current source This suggested control algorithm can compensate harmonics which are generated by nonlinear load such as diode or thyristor converter and reactive power in 3-phase 3-wire power distribution system This control algorithm extracts a compensation voltage reference from performance function without phase transformation Therefore this control algorithm is simpler than any other conventional control algorithm. 3-phase 3-wire series active power filter and hybrid active power filter is manufactured and experiments are carried out for harmonic voltage source and harmonic current source to verify the effectiveness of presented control algorithm Experimental results are presented in this Paper, as well.

  • PDF

회전하는 동기 좌표계 d-q 변환을 이용한 단상 능동 전력 필터의 새로운 제어기 (A New Controller of Single Phase Active Power Filter Using Rotating Synchronous Frame d-q Transformation)

  • 강민구
    • 전자공학회논문지
    • /
    • 제51권6호
    • /
    • pp.271-275
    • /
    • 2014
  • 회전하는 동기 좌표계 d-q 변환을 이용한 단상 능동 전력 필터의 새로운 제어기를 제안하였다. 힐버트 변환기를 사용하여 $90{\circ}$의 위상차를 가지는 두 개의 교류 신호를 만든다. 이 신호들을 회전하는 동기 좌표계 d-q 변환을 이용하여 기본파 성분을 직류로 변환할 수 있고 따라서 고조파 검출이 용이하다. 순시 유효 전력의 평균값을 구한다. 역률 보상을 하므로 전원 전류는 전원 전압과 동위상이다. 단상에서의 전력 공식으로부터 전원 전류의 크기를 알 수 있다. 능동 전력 필터의 보상 전류의 기준 신호는 전원 전류의 기준신호에서 부하 전류를 빼주면 구할 수 있다. 새롭게 제안된 제어기에 히스테리시스 전류 제어기를 적용하여 시뮬레이션 하였다. 능동 전력 필터가 부하전류의 고조파와 무효전력을 보상하여 전원 전류가 전원전압과 동위상이 되고 전원전류가 정현파에 가깝게 되는 것을 확인하였다. 힐버트 변환기는 전대역 여파기를 사용하여 구현하였다.

침수 상용전원에 의한 감전위험성 검토 (A Study on the Electric Shock due to Submerged Power Source)

  • 정종욱;정진수
    • 조명전기설비학회논문지
    • /
    • 제21권6호
    • /
    • pp.71-76
    • /
    • 2007
  • 본 논문에서는 상용전원이 침수되었을 경우, 이에 의한 인체 감전의 위험성을 실증실험을 통해 검토하였다. 실험을 위해 한쪽 벽면에 노출된 충전부가 설치된 모의수조를 구축하고 내부에 도전성 수용액을 채운 후, 전원으로부터의 거리, 방향, 도전성 수용액의 전도율 및 수위에 따른 전위를 측정하였다. 실험 결과 수중에 설치된 전원장치로 인한 전위분포는 거리에 따라 달라지지만, 침수 수용액의 도전율, 노출된 충전부로부터의 각도 및 측정높이는 전기적으로 미치는 영향이 거의 없음이 확인되었다.

고전압 용량성 결합 플라즈마 시스템의 개선된 전압 파형 출력을 위한 펄스 전류 발생장치 회로 (Current Source Type Pulse Generator with Improved Output Voltage Waveform for High Voltage Capacitively Coupled Plasma System)

  • 채범석;민주화;서용석;김현배
    • 전력전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.153-160
    • /
    • 2019
  • This study proposes a current source-type pulse generator to improve output voltage and current waveforms under a capacitively coupled plasma (CCP) system. The proposed circuit comprises two parallel-connected current source-type converters. These converters can satisfy the required output waveforms of plasma processing. The parallel-connected converters operate without reverse current fault by applying a time-delay control technique. Conventional voltage source converters based on pulse power supply exhibit drawbacks in short-circuit current, and problems occur when they are applied to a CCP system. The proposed pulse power supply based on a current source converter fundamentally solves the short-circuit current problem. Therefore, this topology can improve the voltage and current accuracy of a CCP system.

Micro-Source의 계통 연계용 인덕터 크기 선정에 관한 연구 (A Study on Determining the Size of the Interface Inductor for Grid-Connected Micro-Sources)

  • 손광명;김영섭
    • 조명전기설비학회논문지
    • /
    • 제19권6호
    • /
    • pp.52-58
    • /
    • 2005
  • Micro-Grid의 개념은 CERTS(Consortium for Electric Reliability Technology Solutions)에 의해 제안된 새로운 분산 전원 망으로서 부하에 열과 수 $[KW]{\sim}1[MW]$ 사이의 전력을 함께 제공하는 Micro-Source에 의해 구성되어 있다. Micro-Source는 친환경적인 연료전지나 마이크로터빈 등을 에너지원으로 사용하며, 전력품질 제어를 위해 전압형 인버터를 채용하고 독립적인 유무효전력 제어가 가능한 새로운 개념의 분산전원이다. Micro-Source가 효율적으로 유효전력 및 무효전력을 전력시스템에 공급하기 위해서는 계통연계용 인덕터가 필요한데, 본 논문에서는 인덕터의 제어 범위와 각 변수의 한계를 함께 고려하고 전달 및 제어하고자 히는 유효 및 무효 전력의 범위에 의해 인덕터 용량을 결정하는 절차를 제안하였다.

Three-Phase Soft Switching Sinewave Inverter with Bridge Power Module Package Configurated Auxiliary Resonant AC Link Snubber

  • Iyomori Hisashi;Nagai Shin-ichiro;Shiraishi Kazuhiro;Ahmed Tarek;Eiji Hiraki;Mutsuo Nakaoka
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.507-510
    • /
    • 2003
  • This paper presents a novel prototype of tile three-phase bridge power block module type a auxiliary resonant AC link snubber circuit, which is effectively used for the three-phase voltage source type sinewave soft switching PWM inverter using IGBTs. Its operating principle Is described for current source load model, along with its practical design approach based on the simulation data. The performance evaluation of the three-phase voltage source type snewave soft switching PWM inverter incorporating a single three-phase bridge mo여le of active auxiliary resonant AC link snubber treated here Is illustrated, which is concerned with power duality efficiency power loss analysis. This inverter is discussed as compared with those of tile three-phase voltage source type sinewave hard switching PWM inverter. The power loss analysis of this soft switching PWM Inverter using IGBT power modules is evaluated on the basis of the measured v-i characteristics and switching power losses of IGBT, and antiparaliel diodes. The practical effectiveness of this inverter is proven by the power loss analysis for distributed power supply.

  • PDF