• Title/Summary/Keyword: power sensor-less

Search Result 200, Processing Time 0.026 seconds

Design and fabrication of a 300A class general-purpose current sensor (300A급 일반 산업용 전류센서의 설계 및 제작)

  • Park, Ju-Gyeong;Cha, Guee-Soo;Ku, Myung-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.1-8
    • /
    • 2016
  • Current sensors are used widely in the fields of current control, monitoring, and measuring. They have become more popular with the increasing demand for smart grids in a power network, generation of renewable energy, electric cars, and hybrid cars. Although open loop Hall effect current sensors have merits, such as low cost, small size, and weight, they have low accuracy. This paper describes the design and fabrication of a 300A open loop current sensor that has high accuracy and temperature performance. The core of the current sensor was calculated numerically and the signal conditioning circuits were designed using circuit analysis software. The characteristics of the manufactured open loop current sensor of 300 A class was measured at currents up to 300 A. According to the test of the current sensor, the accuracy error and linearity error were 0.75% and 0.19%, respectively. When the temperature compensation was carried out with the relevant circuit, the temperature coefficients were less than $0.012%/^{\circ}C$ at temperatures between $-25^{\circ}C$ and $85^{\circ}C$.

The Effect of Wireless Channel Models on the Performance of Sensor Networks (채널 모델링 방법에 따른 센서 네트워크 성능 변화)

  • 안종석;한상섭;김지훈
    • Journal of KIISE:Information Networking
    • /
    • v.31 no.4
    • /
    • pp.375-383
    • /
    • 2004
  • As wireless mobile networks have been widely adopted due to their convenience for deployment, the research for improving their performance has been actively conducted. Since their throughput is restrained by the packet corruption rate not by congestion as in wired networks, however, network simulations for performance evaluation need to select the appropriate wireless channel model representing the behavior of propagation errors for the evaluated channel. The selection of the right model should depend on various factors such as the adopted frequency band, the level of signal power, the existence of obstacles against signal propagation, the sensitivity of protocols to bit errors, and etc. This paper analyzes 10-day bit traces collected from real sensor channels exhibiting the high bit error rate to determine a suitable sensor channel model. For selection, it also evaluates the performance of two error recovery algorithms such as a link layer FEC algorithm and three TCPs (Tahoe, Reno, and Vegas) over several channel models. The comparison analysis shows that CM(Chaotic Map) model predicts 3-time less BER variance and 10-time larger PER(Packet Error Rate) than traces while these differences between the other models and traces are larger than 10-time. The simulation experiments, furthermore, prove that CM model evaluates the performance of these algorithms over sensor channels with the precision at least 10-time more accurate than any other models.

Composite Gas Measurement System using NDIR Method (NDIR 방법을 이용한 복합 가스 측정 시스템)

  • Eo, Ik-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.624-629
    • /
    • 2018
  • The current study was conducted to develop a portable composite gas detector allowing the detection of both $CO_2$ and $CH_4$ gases by means of the Non Dispersive Infra-Red (NDIR) method. The gas detector is configured to radiate infrared waves using infrared lamps, where the wavelength of the infrared light is reduced due to absorption throughout the chamber, and this reduction (absorption) is detected by the absorption detector, before being converted and amplified to a 3.5V~6V electrical signal, providing as accurate a measurement as possible. The conventional singe sensor method measures the relative measurement by absorbing only specified wavelengths of infrared radiation, which in the case of gas detection leads to problems with accuracy due to the lack of a reference sensor when detecting light with a wavelength of only $4.26{\mu}m$. The dual sensor employed in this study provides a comparative measurement between the reference value derived from the wavelength of $3.91{\mu}m$, which is not influenced by other gas sources, and the measurement value derived from the wavelength of $4.26{\mu}m$, in order to reduce the errors and enhance the reliability, thereby allowing low power consumption for portable devices and multi-gas detection for both $CO_2$ and $CH_4$ gases. The portable composite gas detector developed herein provides a measurement rage of 0ppm~5,000ppm for $CO_2$ gas, and 0.5%vol for $CH_4$, which allows the determination of whether the $CO_2$ and $CH_4$ contents in indoor air are less than 1,000ppm or not. The current study established that the composite gas detector can be interlinked with firefighting appliances through portable devices or home automation, and is anticipated to be very effective in fire prevention.

Implementation of User Interface and GeoSensor based Traveling Type Sub-Observation Prototype System for Monitoring of Groundwater (지하수 모니터링을 위한 GeoSensor 기반의 이동식 보조관측망 프로토타입 시스템 및 사용자 인터페이스 구현)

  • Kim, Kyung-Jong;Jung, Se-Hoon;Sim, Chun-Bo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.1
    • /
    • pp.183-192
    • /
    • 2012
  • Although underground water resource has relatively less pollution rate compared with surface water, its recovery faces many difficulties due to poor management. Our country monitors underground water to manage it effectively through auxiliary observation network for underground water. In this paper, we suggest water-well auto measure system based on Geosensor for business efficiency increase of water-well management and realtime monitering. In this system is consist of user GUI(Graphic User Interface) composed with water-well information and movement sub-observation network prototype system composed with GPS(Global Positioning System) and wireless sensor node such as water temperature, water level, electrical conductivity. In this system is using the light of the sun for self-power, variety water-well information collected wireless sensor node was a wireless transmitting/receiving a using CDMA(Code Division Multiple Access) module. Also, for promote with user ease, user GUI express that water-well collected in GIS(Geographic Information System) map. For performance evaluation of the proposed system, we perform experiment using sensing information through designed sub-observation network. And we was proved superiority of the proposed system through qualitative evaluation with other paper.

SIR analysis for Enhancing Image Quality in Underwater Acoustic Lens System (수중음향렌즈 카메라에서 영상 품질 향상을 위한 SIR 분석)

  • Lee, Jieun;Im, Sungbin;Shim, Taebo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.181-190
    • /
    • 2014
  • The underwater acoustic lens system is one of the systems getting high-resolution images on the seafloor by the beam forming method using acoustic lens. The beam forming using acoustic lenses reduces complexity and driving power. When receiving an incoming beam with the acoustic lens array, beam pattern analysis and arrangement problem of the array sensor must be addressed. Introducing SIR (Signal to Interference Ratio), the relationship among sensor interval, beam pattern and image quality would be analyzed. Generally if the sensor interval getting wider, the less effect of the side lobes makes SIR high. If the amplitude of a side lobe is high, SIR is generally getting low. The type of the apodization function changes the width, shape and amplitude of both main lobe and side lobes. Thus an appropriate apodization function can improve SIR. In this paper, SIR is stable at the sensor interval of 13mm with 0-10dB, which is not high relatively. By applying the Chebyshev function, the SIR becomes 80dB over the sensor interval of 37 mm or higher. The Hann and triangular functions demonstrate better SIR when the sensor interval becomes narrower.

A Thermoelectric Energy Harvesting Circuit For a Wearable Application

  • Pham, Khoa Van;Truong, Son Ngoc;Yang, Wonsun;Min, Kyeong-Sik
    • Journal of IKEEE
    • /
    • v.21 no.1
    • /
    • pp.66-69
    • /
    • 2017
  • In recent year, energy harvesting technologies from the ambient environments such as light, motion, wireless waves, and temperature again a lot of attraction form research community [1-5] due to its efficient solution in order to substitute for conventional power delivery methods, especially in wearable together with on-body applications. The drawbacks of battery-powered characteristic used in commodity applications lead to self-powered, long-lifetime circuit design. Thermoelectric generator, a solid-state sensor, is useful compared to the harvesting devices in order to enable self-sustained low-power applications. TEG based on the Seebeck effect is utilized to transfer thermal energy which is available with a temperature gradient into useful electrical energy. Depending on the temperature difference between two sides, amount of output power will be proportionally delivered. In this work, we illustrated a low-input voltage energy harvesting circuit applied discontinuous conduction mode (DCM) method for getting an adequate amount of energy from thermoelectric generator (TEG) for a specific wearable application. With a small temperature gradient harvested from human skin, the input voltage from the transducer is as low as 60mV, the proposed circuit, fabricated in a $0.6{\mu}m$ CMOS process, is capable of generating a regulated output voltage of 4.2V with an output power reaching to $40{\mu}W$. The proposed circuit is useful for powering energy to battery-less systems, such as wearable application devices.

Analysis of Power Requirement of Agricultural Tractor during Baler Operation (베일러 작업 시 트랙터 소요동력 분석)

  • Kim, Yong-Joo;Lee, Dae-Hyun;Chung, Sun-Ok;Park, Seung-Jae;Choi, Chang-Hyun
    • Journal of Biosystems Engineering
    • /
    • v.36 no.4
    • /
    • pp.243-251
    • /
    • 2011
  • Purpose of this study was to analyze power requirement of an agricultural tractor for baler operation. First, a power measurement system was developed and installed in a 75 kW agricultural tractor. Strain-gages with a telemetry system were used to measure torques of transmission and PTO input shafts. An engine tachometer was used to measure rotational speed of transmission and PTO input shafts. The measurement system also included pressure sensors to measure pressure of hydraulic pumps, an I/O interface to acquire the sensor signals, and an embedded system to determine power requirements. Second, field experiments were conducted at two PTO speed levels, and proportion of utilization ratio of rated engine power and power consumption of major parts (transmission input shaft, PTO input shaft, main hydraulic pump, and auxiliary hydraulic pump) were analyzed. Results of usage proportion of engine power for PTO speed level 1 and 2 were 4.1 and 2.2%, 31.5 and 16.3%, 49.6 and 59.7%, 14.4 and 20.8%, and 0.4 and 1.0%, respectively, for ratio of measured engine power to rated engine power of less than 25%, 25 ~ 50%, 50 ~ 75%, 75 ~ 100%, and greater than 100%. The results showed that the usage proportion increased in the range with the ratio of power requirement to rated engine power of over than 50% when the PTO gear was shifted from P1 to P2. Averaged engine power requirement for baling operation, tying and discharging operation, and total operation were 43.3, 37.3, and 42.0 kW and 49.0, 37.0, and 47.4 kW, respectively, for PTO speed level 1 and 2. Paired t-test showed significant difference in power consumption of engine, transmission input shaft, and PTO input shaft for different PTO speed levels. Therefore, the power consumption of engine for baler operation increased when the PTO gear was shifted from P1 to P2. It was indicated that the power requirement of tractor was affected by the PTO rotational speed for baler operation.

Diminution of Current Measurement Error in Vector Controlled AC Motor Drives

  • Jung Han-Su;Kim Jang-Mok;Kim Cheul-U;Choi Cheol;Jung Tae-Uk
    • Journal of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.151-159
    • /
    • 2005
  • The errors generated from current measurement paths are inevitable, and they can be divided into two categories: offset error and scaling error. The current data including these errors cause periodic speed ripples which are one and two times the stator electrical frequency respectively. Since these undesirable ripples bring about harmful influences to motor driving systems, a compensation algorithm must be introduced to the control algorithm of the motor drive. In this paper, a new compensation algorithm is proposed. The signal of the integrator output of the d-axis current regulator is chosen and processed to compensate for the current measurement errors. Usually the d-axis current command is zero or constant to acquire the maximum torque or unity power factor in the ac drive system, and the output of the d-axis current regulator is nearly zero or constant as well. If the stator currents include the offset and scaling errors, the respective motor speed produces a ripple related to one and two times the stator electrical frequency, and the signal of the integrator output of the d-axis current regulator also produces the ripple as the motor speed does. The compensation of the current measurement errors is easily implemented to smooth the signal of the integrator output of the d-axis current regulator by subtracting the DC offset value or rescaling the gain of the hall sensor. Therefore, the proposed algorithm has several features: the robustness in the variation of the mechanical parameters, the application of the steady and transient state, the ease of implementation, and less computation time. The MATLAB simulation and experimental results are shown in order to verify the validity of the proposed current compensating algorithm.

Design of Low-Power Hybrid LNA with Multi-Input for Mobile Ultrasound System (이동형 초음파시스템에 적합한 다중 입력방식의 저전력 혼성 저잡음 증폭기 설계)

  • Song, Jae-Yeol;Lee, Kyung-Hoon;Park, Sung-Mo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.2
    • /
    • pp.64-69
    • /
    • 2014
  • Ultrasound system is one of the complex wireless signal processing systems that are widely used in the fields of modern industry such as medical diagnostics, underwater communications, and sensor-networks. Miniaturization of ultrasound system has been raging recently. In this paper, a hybrid LNA that is suitable for miniaturization and mobile diagnostic ultrasound system has been developed. The proposed LNA has low noise figure of less than 5dB, and the feedback resistor is designed to be electrically adjusted in order to attain the impedance-matching for various ultrasound transducers. It supports the whole ultrasound frequencies from 10KHz to 150MHz frequency band and also provides sleep modes. A gain from -18.8 to -29.5 dB is achieved by adjusting each transducer to fit the system character. Power consumption can be reduced up to 90% in similar performance as compared to the existing LNA.

Design and Implementation Testbed of Home Network based PLC (PLC 기반의 홈 네트워크 테스트베드 설졔 및 구현)

  • Kim, Hyeock-Jin;Han, Kuy-Ban;Jean, Byoung-Chan
    • Journal of the Korea Computer Industry Society
    • /
    • v.10 no.4
    • /
    • pp.143-150
    • /
    • 2009
  • Remote control service, monitoring, gear service of information electronic appliance, various services of security service and so on of Home network that is by link of Ubiquitous environment are offered. These services need verification process through priority test to use and are changed. If test using actuality information electronic device for test, much expenses and time may be invested. Home network test bed offers softness of research using control model and simulator, in this paper, Wish to design and embody home network test bed to do environment construction of home network and test of application service. Because use istent power line just as it is without necessity to establish circuit in addition by solution of home network testbed, expense costs to be less and establishment used easy PLC. Also, propriated Wireless sensor network that use Zigbee by solution of home network testbed. Appliance check and monitor square do by Home Auto that know embodied, and embodied by Home Gateway that interlink terminals of Home Auto and out of.

  • PDF