• Title/Summary/Keyword: power quality

Search Result 5,333, Processing Time 0.029 seconds

A Study on Power Quality Diagnosis System using Neural NetWorks (전기품질 진단 시스템 개발을 위한 인공 신경망 적용에 관한 연구)

  • Kim, Jin-Su;Kim, Young-Il;Kim, Kwang-Soon;Park, Gi-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1351-1359
    • /
    • 2007
  • In this paper, we have studied the power quality(PQ) diagnosis system with the two methods for PQ diagnosis. One to Apply a regulation value in compliance with mathematics calculation, and the other Automatic identification using Neural network algorithm. Neural network algorithm is used for an automatic diagnosis of the PQ. The regulation proposed by IEEE 1159 Working group is applied for the precision of the diagnosis. In order to divide accurate segmentation, the algorithm for a computer training used the back propagation out of several neural network algorithms. We have configured the proto-type sample by using Labview and a programmed Neural Networks Algorithm using with C. And arbitrary electric Signal generated by OMICRON Company's CMC 256-6 for an efficiency test.

The Development of 30KVA IGBT-type Customer STATCOM (수용가용 30kVA급 IGBT형 STATCOM 개발)

  • Lim, Su-Saeng;Lee, Eun-Woong;Kim, J.K.;Sohn, H.K.;Cho, H.K.;Jeong, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.657-659
    • /
    • 2002
  • Power quality refers to voltage quality and current quality. Voltage quality means supply reliance such as voltage sag, voltage swell. and short-time interruption. Current quality is related to power factor, harmonic distortion, negative-sequence and zero-sequence current. We fabricated Customer STATCOM to improve current quality such as reactive power, harmonic distortion, and load imbalance. In this paper. We summarize the spec, of STATCOM. its hardware configuration, and control system.

  • PDF

Connected Characteristics for Small Generation Source of Low Voltage Model Grids (저압 모의선로에 소형발전원 연계시 특성)

  • Lee, Sang-Woo;Kang, Jin-Kyu;Lee, Dong-Ha;Park, Tae-Joon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.45-53
    • /
    • 2013
  • In this paper, we analyze the typical phase voltage and line current waveform characteristics of the distribution system with 3 phase small synchronous generation source in case with load and non-load group, in order to investigate the power quality for end load connected of generation source. As demonstrated by our experimental results, the distortion and power quality of phase voltage and line current waveform were relatively good for low voltage 3 phase model grids connected of 3 phase small synchronous generation source in case with non-load group. However, distortion and power quality of voltage and current waveform was poor for low voltage 3 phase model grids connected to 3 phase small synchronous generation source in the load group with some phase voltage and frequency difference. From the above results, we conclude that the phase voltage and frequency of 3 phase generation source must be identical to that of distribution system source to maximize the power quality. Also, special attention is required in case of having load group or non-load group to 3 phase generation source.

An Analysis of the Relationship between Elevator Emergency(Entrapment) and Situation Measurement of Sag/Interruptions at the Switchboard

  • Kim, Gi-Hyun;Lim, Young-Bae;Bai, Seok-Myung;Kim, Jae-Chul;Lee, Hee-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.36-44
    • /
    • 2007
  • This study researched the mutual relationship between elevator emergencies(sudden stops, entrapment) and power quality such as voltage interruptions or sags. To analyze the power quality at the elevator switchboard of an apartment, the on-line power quality(sag, swell, and interruption, etc.) were measured and error messages(under voltage error, etc.) in the elevator control room were researched. Also the performance and susceptibility for stops were evaluated and stated through the testing of three pieces of simulated test equipment with an EN12016(2004) standard setting and the magnitude and duration data of the measured sag or interruption. This paper will use these data in the analysis of the mutual relationship between power quality and elevator emergencies.

A Study on the Moderating Effect of Psychological Power in the Relationahip between Service, Image, and Satisfaction in the Tourism Context

  • Davaanyam, BOLORTUYA;Muhammad, RAZA;Jin-Kwon, KIM;Tony-Donghui, AHN
    • The Journal of Economics, Marketing and Management
    • /
    • v.11 no.1
    • /
    • pp.45-52
    • /
    • 2023
  • Purpose: The purpose of this study is to investigate the relationship between service quality, destination image, and tourist satisfaction for foreign tourists visiting Korea, and in particular, to analyze the moderating effect of psychological power in the relationship. Research design, data, and methodology: A research model was derived through existing literature research and a survey was conducted on foreign tourists visiting Korea. Structural equation model of SPSS and AMOS24.0 were used for data analysis and hypothesis testing. Results: The tourism service quality affects the image of tourist attractions. Images of tourist attractions were found to affect tourism satisfaction. It was found that the lower the psychological power, the greater the effect on the relationship between service quality and image, and the relationship between image and satisfaction. Conclusions: This study demonstrated that service quality at travel destinations is a key factor in order to enhance the image and satisfaction of Korean tourist destinations for foreigners visiting Korea. On the other hand, since the image and satisfaction level of the tourism destination vary depending on personal factors such as psychological power, it suggests that travel industry workers or researchers should develop and operate services tailored to the individual characteristics of the tourists.

Automatic classification of power quality disturbances using orthogonal polynomial approximation and higher-order spectra (직교 다항식 근사법과 고차 통계를 이용한 전력 외란의 자동식별)

  • 이재상;이철호;남상원
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1436-1439
    • /
    • 1997
  • The objective of this paper is to present an efficient and practical approach to the automatic classification of power quality(PQ) disturbances, where and orthogonal polynomial approximation method is emloyed for the detection and localization of PQ disturbances, and a feature vector, newly extracted form the bispectra of the detected signal, is utilized for the automatic rectgnition of the various types of PQ disturbances. To demonstrae the performance and applicabiliyt of the proposed approach, some simulation results are provided.

  • PDF

An Assessment on Voltage and Power Quality in Load Facility during the Islanding of Residential Fuel Cell System (가정용 연료전지 시스템의 단독운전 시 부하설비의 전압 및 전력품질 평가)

  • Park, Chan-Eom;Jung, Jin-Soo;Han, Woon-Ki;Lim, Hyun-Sung;Song, Young-Sang;Kim, Choon-Sam;Lim, Duk-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.12
    • /
    • pp.1792-1797
    • /
    • 2013
  • Recently, due to the excessive use of fossil fuels, many studies about the fossil fuels such as solar and fuel cell energy source are progressing. Fuel cell system has high energy conversion efficiency. Also, fuel cell system is environmentally friendly system because the carbon emission is almost not occur. Therefore, the fuel cell system is considered as the core technology of in the fields of the future energy and environmental. Fuel cell system has an effect on distribution power system because another power source of other than large power plants. So, fuel cell system can be reason of power quality in the power system. In this paper, we constructed the system for an assessment on Islanding. The system is composed with power source, Impedance coordination load and linear load, fuel cell system. we are performed assessment on voltage and power quality in customer and the distributed power system during the Islanding of residential fuel cell system. In addition, no change in the impedance of power system, we made a islanding condition only using the actual load, As a variation of generation and load current under islanding, an analysis results based on assessment system showed that the power qualities of distribution system became more aggravation as effect of voltage sag and voltage swell phenomena.

Low-Cost Remote Power-Quality-Failure Monitoring System using Android APP and MCU (안드로이드 앱과 MCU를 이용한 저가형 원격 전원품질이상 감시 시스템)

  • Lim, Ho-Kyoun;Kim, Seo-Hwi;Lee, Seung-Hyeon;Choe, Sangho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.144-155
    • /
    • 2013
  • This paper presents a low-cost remote power-quality-failure monitoring system (RPMS) using Android App and TI MCU (micro-controller unit), which is appliable to a micro-grid. The designed RPMS testbed consists of smart nodes, a server, and Android APPs. Especially, the C2000-series MCU-based RPMS smart node that is low-cost compared to existing monitoring systems has both a signal processing function for power signal processing and a data transmission function for power-quality monitoring data transmission. The signal processing function implements both a wavelet-based power failure detection algorithm including sag, swell, and interruption, and a FFT-based power failure detection algorithm including harmonics such that reliable and real-time power quality monitoring is guaranteed. The data transmission function implements a low-complexity RPMS transmission protocol and defines a simple data format (msg_Diag) for power monitoring message transmission. We may watch the monitoring data in real time both at a server and Android phone Apps connected to the WiFi network (or WAN). We use RS-232 (or Bluetooth) as the wired (or wireless) communication media between a server and nodes. We program the RPMS power-quality-failure monitoring algorithm using C language in the CCS (Code Composer Studio) 3.3 environment.

Enhancement of Power System Transient Stability and Power Quality Using a Novel Solid-state Fault Current Limiter

  • Fereidouni, A.R.;Vahidi, B.;Mehr, T. Hoseini;Doiran, M. Garmroodi
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.474-483
    • /
    • 2011
  • Solid-state fault current limiters (SSFCL) in power systems are alternative devices to limit prospective short circuit currents from reaching lower levels. Fault current limiters (FCL) can be classified into two categories: R-type (resistive) FCLs and L-type (inductive) FCLs. L-type FCL uses an inductor to limit fault level and is more efficient in suppressing voltage drop during a fault. In contrast, R-type FCL is constructed with a resistance and is more effective in consuming the acceleration energy of generators during a fault. Both functions enhance the transient stability of the power system. In the present paper, a novel SSFCL is proposed to enhance power system transient stability and power quality. The proposed SSFCL uses both functions of an L-type and R-type FCL. SSFCL consists of four diodes, one self-turn-off IGCT, a current-limiting by-pass inductor (L), and a variable resistance parallel with an inductor for improvement of power system stability and prevention of over-voltage across SSFCL. The main advantages of the proposed SSFCL are the simplicity of its structure and control, low steady-state impedance, fast response, and the existence of R-type and Ltype impedances during the fault, all of which improve power system stability and power quality. Simulations are accomplished in PSCAD/EMTDC.

Power Quality of Wind/Diesel Hybrid Operation at an Micro Grid (마이크로 그리드에서의 풍력/디젤 복합발전 전력품질)

  • Kim, Seok-Woo;Ko, Seok-Whan;Jand, Moon-Seok
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.4
    • /
    • pp.41-47
    • /
    • 2009
  • Wind/diesel hybrid operation can be one of the most effective option for electrical power production at a remote area such as Antarctica. The king Sejong station at Antarctica relies its power production on diesel engines and diesel oil is supplied every other year by ships. However, the oil transportation processes are liable to potential oil spillage caused by the floating ice around the King George island. The long-term storage of the oil at the station can also contaminate the surrounding soils. A l0kW wind turbine has been installed to save oil consumption and operated in connection with the diesel generators since 2006. The diesel engine that operated poorly during the first year of installation was replaced in 2008 to enhance power production an recent measurements indicate that both diesel power quality and the wind turbine availability have been dramatically improved by the replacement. This report discusses electrical power qualities of wind/diesel hybrid system operating at an isolated micro gird located in the king Sejong station. Our experience reveals that the similar technologies can be applied to domestic islands, for example, in the south sea.