• 제목/요약/키워드: power oscillation

검색결과 542건 처리시간 0.032초

퍼지이론을 적용한 전력계통안정화 장치 설계 (Design of Power System Stabilizer applying fuzzy theory)

  • 이호준;박지호;백영식;신정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.245-247
    • /
    • 1999
  • The problem of small-signal stability is usually one of insufficient damping of system oscillations. The use of power system stabilizers to control generator excitation system os the most cost effective method of enhancing the small-signal stability of power system. This paper presents the fuzzy type stabilizing controller to damp out the sustained oscillation, which is observed in normal operation. through the comparative simulation with PI type power stabilizer under various system operating condition, the efficiency of fuzzy stabilizing controller with respect to nonlinear power system is verified.

  • PDF

이동구간 최적 제어에 의한 전력계통 안정화의 분산제어 접근 방법 (A Decentralized Approach to Power System Stabilization by Artificial Neural Network Based Receding Horizon Optimal Control)

  • 최면송
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권7호
    • /
    • pp.815-823
    • /
    • 1999
  • This study considers an implementation of artificial neural networks to the receding horizon optimal control and is applications to power systems. The Generalized Backpropagation-Through-Time (GBTT) algorithm is presented to deal with a quadratic cost function defined in a finite-time horizon. A decentralized approach is used to control the complex global system with simpler local controllers that need only local information. A Neural network based Receding horizon Optimal Control (NROC) 1aw is derived for the local nonlinear systems. The proposed NROC scheme is implemented with two artificial neural networks, Identification Neural Network (IDNN) and Optimal Control Neural Network (OCNN). The proposed NROC is applied to a power system to improve the damping of the low-frequency oscillation. The simulation results show that the NROC based power system stabilizer performs well with good damping for different loading conditions and fault types.

  • PDF

퍼지형 전력계통안정화제어기의 실계통 적용 및 안정도 향상 (Application of Fuzzy-PSS to KEPCO power system and stability enhancement)

  • 최경선;이동인;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.1052-1055
    • /
    • 1997
  • The importance of dynamic stability of power system is increasing as the excitation system using static type are greatly enlarged. There are several types of PSS at Present, Elements of PSS consist of Notch filter, lead-lag filter, washout limiter which are variable. The existing power system has a difficulty in determining the optimal PSS parameters whenever PSS is installed. And it is recommended to retune PSS parameters periodically because system characteristics change due to aging. In this paper, intelligent PSS using fuzzy concept is introduced to get over difficulties mentioned above. The usefulness of fuzzy-type PSS was verified by applying FPSS to KEPCO power system. Generally, the voltage regulation deteriorates if conventional PSS is applied because supplementary signal is added into AVR summing point to damp Power oscillation. In this paper this problem is solved by AVR limiter and fuzzy members tuning.

  • PDF

6펄스 콘버어터로 제어되는 초전도 에너지 저장장치에 의한 전력계통 안정화

  • 차귀수;한송엽;원종수
    • 대한전기학회논문지
    • /
    • 제35권8호
    • /
    • pp.353-362
    • /
    • 1986
  • This paper shows that 6 pulse converter instead of 12 pulse converter can be used for the control of Superconducting Magnet Energy Storage(SMES) to improve the stability and to suppress the voltage fluctuation of power system. In order to prevent the commutation failure, when 6 pulse converter used for simultaneous control of real power and reactive power is asymmetrically controlled, stable control region has been presented by analyzing the commutation phenomena at critical points which distinguish the stable control region from the unstrol control region. Harmonic components of line current and output voltage have been calculated. Finally, computer simulation of power system stabilization has been presented to show the effectiveness of the proposed method. According to the computation results, SMES controlled by the 6 pulse converter is an effective measure in reducing the oscillation and the transient instability of the power system.

  • PDF

Fabry-Perot 공진기형 AlGaAs 반도체 레이저 증폭기의 이득특성 (Gain Characteristics of Fabry-Perot Type AlGaAs Semiconductor Laser Amplifier)

  • 김도훈;권진혁
    • 한국광학회지
    • /
    • 제2권2호
    • /
    • pp.67-73
    • /
    • 1991
  • 단일 종모드로 동작하며, 10mW의 출력을 가지는 AlGaAs 반도체 레이저를 이용하여 Fabry-Perot 공진기형 레이저 증폭기 시스템을 구성하고 비포화 신호이득(unsaturated signal gain), 신호이득 대역폭(signal gain bandwidth), 포화출력(saturation power)을 측정하였다. 증폭기 레이저의 펌핑전류에 따른 비포화 신호 이득은 발진 문턱 전류 근처에서 $0.7\mu\textrmW$의 레이저 출력을 증폭기 레이저에 입사시켰을 때 최대 25dB을 얻었으며 이때 신호이득의 대역폭이 3 GHz 정도임을 확인하였다. 또한 입력 세기(input power)에 따른 비포화 신호이득의 변화를 측정하고 이때의 포화출력을 측정하였다.

  • PDF

Minimization of Torque Ripple for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Unbalanced Grid Condition

  • Park, Yonggyun;Suh, Yongsug;Go, Yuran
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.273-274
    • /
    • 2012
  • This paper investigates control algorithms for a doubly fed induction generator(DFIG) with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Two different control algorithms to compensate for unbalanced conditions are proposed. Evaluation factors of control algorithm are fault ride-through(FRT) capability, efficiency, harmonic distortions and torque pulsation. Zero regulated negative sequence stator current control algorithm has the most effective performance concerning FRT capability and efficiency. Ripple-free control algorithm nullifies oscillation component of active power and reactive power. Ripple-free control algorithm shows the least harmonic distortions and torque pulsation. Combination of zero regulated negative sequence stator current and ripple-free control algorithm control algorithm depending on the operating requirements and depth of grid unbalance presents the most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system.

  • PDF

복소전력의 변화율을 이용한 동기탈조 검출 알고리즘에 관한 연구-Part I: 복소평면에서의 복소전력의 궤적변화 (A Study on the Out-of-Step Detection Algorithm using Time Variation of Complex Power-Part I : The Variation of Complex Power Trajectory in Complex Plane)

  • 권오상;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권7호
    • /
    • pp.345-351
    • /
    • 2005
  • An out-of-step condition results from the loss of the synchronism of the generators. A disturbance in a power system causes the generator angle to oscillate. When there is a severe disturbance such as a heavy current fault loss of major generation or loss of a large block of load, the oscillation can be severe and even increase largely and finally the out-of-step condition may un. During the power swing and out-of-step conditions, the apparent impedance at a relay location changes, and the power flow also changes as the angle difference is varied. This paper presents a method to analyze the trajectory of complex power during a power swing and out-of-step condition. The trajectory of the complex power is analyzed when a power swings and a fault occurs. Moreover, the complex power is analyzed when the ratios between the voltages at both sides and the line impedances are changed. These methods are verified through simulation using the ATP/EMTP MODELS.

1기 무한모선 전력계통의 적응 전압 제어와 거버너를 이용한 주파수 진동의 억제 (Adaptive Voltage Control of a Single Machine Infinite Bus(SMIB) Power System with Governor Control for Reduced Oscillation of the Frequency)

  • 김석균;윤태웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.51-52
    • /
    • 2008
  • In this paper, we propose two control schemes. The first control scheme is an adaptive passivity-based excitation control which regulates the terminal voltage to its reference. This controller is obtained through two steps: firstly, a simple direct adaptive passivation controller is designed for the power system with parametric uncertainties; then a linear PI controller is applied to converge the terminal voltage to its reference. The second control scheme is a linear governor control which consists of the frequency and the mechanical power. It is shown that the internal dynamics are locally stable with controllable damping. In the end, the boundness of all electrical variables, the frequency, the mechanical power, and the convergence of the terminal voltage to its reference can be achieved by these control schemes.

  • PDF

공진형 인버터에 있어서 RF Noise 저감을 위한 Snubber 최적 회로 설계에 관한 연구 (Optimal Snubber Design Strategy for the Resonant Inverter to Reduce RF Noise)

  • 김은수;유동욱;오성철;이종무
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.380-383
    • /
    • 1990
  • When the MOSPET is applied as a switching device for the resonant inverter, a damped oscillating noise is appeared at specific frequency band. This damped Oscillation is caused by the series and parallel resonance due to distributed circuit parameter of snubber and main circuit. This paper describes the frequency-impedance characteristic of the resonant inverter and optimal snubber design strategy to reduce the RF noise.

  • PDF

영구자석형 동기발전기를 갖는 풍력발전시스템을 위한 EDLC의 새로운 응용 방법 (A novel EDLC application scheme for PMSG type wind power generation system)

  • 김경훈;박민원;유인근;전진홍;안종보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1292-1293
    • /
    • 2011
  • Electric double layer capacitor (EDLC) is used to overcome power quality problem caused by output power oscillation of wind turbines. A novel EDLC application for permanent magnet synchronous generator type wind power generation system is proposed in this paper. The structure of the proposed system is cost-effective and efficient. The proposed system including an EDLC is modeled and analyzed by PSCAD/EMTDC. The simulation results show the effectiveness and major features of the proposed system.

  • PDF