• Title/Summary/Keyword: power of test

Search Result 10,051, Processing Time 0.044 seconds

The Effect of Geometric Factors When Measuring Standard Count for Radioactive Iodine Thyroid Uptake Rate (표준계수 측정 시 기하학적 요인이 방사성 요오드 갑상선 섭취율에 미치는 영향)

  • Oh, Joo Young;Kim, Jung Yul;Oh, Ki Baek;Oh, Shin Hyun;Kim, Jae Sam;Lee, Chang Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.53-61
    • /
    • 2013
  • Objectives: It is certain that Radioactive iodine thyroid uptake(RAIU) rate should be measured with the standard counts considering the thyroid gland depth in enlarged thyroid patients for the variation from geometric factors. The purpose of this paper is to consider the effects of geometric factors according to detector to source distance and the effective thyroid depth on RAIU rate with experiment test. Materials and Methods: I-131 370 kBq ($10{\mu}Ci$) point source was measured by Captus-3000 thyroid uptake system (Capintec, NJ, USA) with a change Detector-Source Distance from 20 cm to 30 cm at an interval of 1 cm. And we changed the Neck phantom surface-Source Depth in the phantom with 1 cm, 2 cm, 5 cm using the neck phantom in order to reproduce the effective thyroid depth. Results: Every experimental group follows power curve as inverse square curve ($$R2{\geq_-}0.915$$). The average count rates in the case not using a phantom and the every case applied the effective thyroid depth using a phantom was not identical each other. There was significant fluctuations upon the effective thyroid depths applied the effective thyroid depth above 1 cm in $364.4 keV{\pm}10%$ energy ROI (p<0.01). There was not significant difference between the count rates of 1 cm and 2 cm in $364.4keV{\pm}20%$ and $637.1keV{\pm}6.2%$ (p=0.354, p=0.397). In assumed RAIU rate from regression equation, $364.4keV{\pm}20%$ was lower difference than $364.4keV{\pm}10%$ as 6.42% and 5.09% per 1 cm. Every change of count rate upon depth appears decreased line on Linear Regression, but the case of $284.3keV{\pm}10%$ increased only. And also, The graphs of coefficient of variation upon depth increased as straight line on every experimental group. Conclusion: The result appears that application of $364.4keV{\pm}20%$ energy ROI is more suitable for reducing error from the effective thyroid depth. And also, we can estimate the error of 20 cm should be highly reduced than 30 cm for Inverse Square Law. Therefore, If there is not information of the thyroid depth, it is considered that the error from thyroid depth can reduce through set up energy ROIs for $364.4keV{\pm}20%$, and increase Detector-Source Distances.

  • PDF

A Study on Hospital Infection Management of Radiological Technologist (방사선사의 병원감염관리에 대한 연구)

  • Jeong, Bong-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.727-735
    • /
    • 2018
  • Targeting the radiological technologists working in Gyoungsangnam province, this study was performed to obtain the fundamental data to improve the competency and right awareness of the hospital infection management, and to educate infection management of radiological technologists by analyzing the status, awareness, and performance of the hospital infection management. During April 1, 2018 to April 31, 2015, after we sent out a total of 400 questionnaires for the survey to radiological technologists working at the clinic located in Gyoungsangnam province, 320 questionnaires suitable for research were analysis by using SPSS 18.0 statistical analysis software. As the hospital infection management factors, 5 items for hospital infection and 60 items of the awareness and performance for the hospital infection management were used. 60 items of the awareness and performance for the hospital infection management were consisted hand hygiene, personal hygiene and clothing, medical equipment and supplies, cleaning and waste, examination and environment. And as the sociodemographic characteristics, the gender, marriage, age, level of education, working organization, working period, and working department were used. Consequentially, the awareness for the hospital infection management($4.19{\pm}.60$) and the performance($4.22{\pm}.52$) were confirmed as high level. Using these results, the hospital infection management level of the radiological technologists working in Gyoungsangnam province was found to be high in arareness and performance of hospital infection management. There was a significant correlation between the degree of awareness and performance of radiological technologists for hospital infection management. Furthermore, in the multiple regression analysis of cognitive factors on performance, it was found that 66.1% explanatory power had a significant positive influence. In order to improve the awareness of hospital infection management of radiological technologist working in various departments, the infection management education and improvement of hospital work environment are necessary. And also, It is important to participate actively in hospital infection management and preventive education and to play a pivotal role in securing expertise in hospital infection management.

A Longitudinal Validation Study of the Korean Version of PCL-5(Post-traumatic Stress Disorder Checklist for DSM-5) (PCL-5(DSM-5 기준 외상 후 스트레스 장애 체크리스트) 한국판 종단 타당화 연구)

  • Lee, DongHun;Lee, DeokHee;Kim, SungHyun;Jung, DaSong
    • Korean Journal of Culture and Social Issue
    • /
    • v.28 no.2
    • /
    • pp.187-217
    • /
    • 2022
  • The aim of this study is to examine the psychometric properties of the Korean version of the Post-traumatic Stress Disorder Checklist for DSM-5(PCL-5). For this purpose, online surveys were conducted for two times with a one year interval using the data from 1,077 Korean adults at time 1, and 563 Korean adults at time 2. First, from the result of the confirmatory factor analysis, comparing the model fit of the 1, 4, 6, and 7-factor model, the 4, 6, and 7-factor model showed a acceptable fit, and the best fit was seen in the order of the 7, 6, 4-factor model. Second, the internal consistency, omega coefficient, construct validity, average variance extracted, and test-retest reliability results were all satisfactory.. Third, a correlation analysis with the K-PC-PTSD-5 and the sub-factors of BSI-18 was conducted to check the validity of the Korean Version of PCL-5. As a result, a positive correlation was seen with both K-PC-PTSD-5 and BSI-18. Fourth, a hierarchical multiple regression was performed to examine whether the Korean Version of PCL-5 predicts future PTSD, depression, anxiety, and somatization. As a result, the Korean Version of PCL-5 measured at time 1 significantly predicted PTSD, depression, anxiety, and somatization symptoms at time 2. Fifth, by analyzing the ROC curve, the discriminant power of PCL-5 for screening PTSD symptom groups was confirmed, and the best cut-off score was suggested. As a result of the longitudinal validation of Korean version of PCL-5, it was found that this scale is a reliable and valid measure for Korean adults. By looking into the predictive validity of the scale, it was found that the Korean version of PCL-5 can predict not only PTSD symptoms but also PTSD-related symptoms such as depression, anxiety, and somatization. Also, this study differs from previous validation studies measuring PTSD symptoms in that it suggested a cut-off score to help differentiate PTSD symptom groups.

Development of High-performance Microwave Water Surface Current Meter for General Use to Extend the Applicable Velocity Range of Microwave Water Surface Current Meter on River Discharge Measurements (전자파표면유속계를 이용한 하천유량측정의 적용범위 확장을 위한 고성능 범용 전자파표면유속계의 개발)

  • Kim, Youngsung;Won, Nam-Il;Noh, Joonwoo;Park, Won-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.8
    • /
    • pp.613-623
    • /
    • 2015
  • To overcome the difficulties of discharge measurements during flood season, MWSCM(micowave water surface current meter) which measures river surface velocities without contacting water has been applied in field work since its development. The existing version of MWSCM is for floods so that its applicability is low due to the short periods of floods. Therefore the renovative redesign of MWSCM to increase the applicability was conducted so that it can be applied to the discharge measurements during normal flows as well as flood ones by extending the measurable range of velocity. A newly developed high-performance MWSCM for general use can measure the velocity range of 0.03-20.0 m/s from flood flows to normal flows, whereas MWSCM for floods can measure the velocity range of 0.5-10.0 m/s. The improvement of antenna isolation between transmitter and receiver to block the inflow of transmitted singals to receiver and the improvement of phase noise of oscillator are necessary for detecting low velocity with MWSCM technology. Separate type antenna of transmitting and receiving signals is developed for isolation enhancement and phase locked loop synthesizer as an oscillator is applied to high-performance MWSCM for general use. Microwave frequency of 24 GHz is applied to the new MWSCM rather than 10 GHz to make the new MWSCM small and light for convenient use of it at fields. Improvement requests on MWSCM for floods-stable velocity measurement, self test, low power consumtion, and waterproof and dampproof-from the users of it has been reflected on the development of the new version of MWSCM.

Improvement of Heat Pump Heating Performance by Selective Heat Storage Using Air Heat of Inside and Outside Greenhouse (온실 내외부 공기열의 선택적 축열에 의한 히트펌프 난방성능 개선)

  • Kwon, Jin Kyung;Kim, Seung Hee;Jeon, Jong Gil;Kang, Youn Koo;Jang, Kab Yeol
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.353-360
    • /
    • 2017
  • In this study, the design and performance test of the air to water heat pump capable of producing hot water for greenhouse heating by using the surplus solar heat inside the greenhouse and the air heat outside greenhouse as the selective heat source were conducted. The heat storage operations using the surplus solar heat and the outside air heat were designed to be switched according to the setting temperature of the greenhouse in consideration of the optimum temperature range of the crop. In the developed system, it was possible to automatically control the switching of heat storage operation, heating and ventilation by setting 12 reference temperatures on the control panel. In the selective heat storage operation with the surplus solar heat and outside air heat, the temperature of thermal storage tank was controlled variably from $35^{\circ}C$ to $52^{\circ}C$ according to the heat storage rate and heating load. The heat storage operation times using the surplus solar heat and outside air heat were 23.1% and 30.7% of the experimental time respectively and the heat pump pause time was 46.2%. COP(coefficient of performance) of the heat pump of the heat storage operation using the surplus solar heat and outside air heat were 3.83 and 2.77 respectively and was 3.24 for whole selective heat storage operation. For the comparative experiment, the heat storage operation using the outside air heat only was performed under the condition that the temperature of the thermal storage tank was controlled constantly from 50 to $52^{\circ}C$, and COP was analyzed to be 2.33. As a result, it was confirmed that the COP of the heat storage operation using the surplus solar heat and outside air heat as selective heat source and the variable temperature control of the thermal storage tank was 39% higher than that of the general heat storage operation using the outside air heat only and the constant temperature control of the thermal storage tank.

Effect of the Nematode Sterilization of Nursery Medium using QRD Microwave in the Plant Factory (QRD 마이크로파를 이용한 식물공장용 배지의 멸균 효과)

  • Kim, Jin Hyun;Kim, Tae Wook;Lee, Keun Woo;Ha, Yu Shin;Lee, Jae Hyun;Kim, Kyung Min
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.100-107
    • /
    • 2013
  • Unlike general microwave, QRD (Quadratic Residue Diffusor) Microwave used in this study is known as a new technology that enhances the sterilization effect with low power because it is possible to induce the average sterilization by changing wavelength phase difference. Therefore, basic research was conducted on the function that could sterilize culture media for plant factory by using environmentally friendly and low energy consuming QRD Microwave. The results are as follows: It was confirmed that there was no external deformation in the polyurethane foam and rock wool medium when changing the microwave level between 2 and 8 kW in different water content of culture media. However, PDA solid media at 2 kW were not dissolved in 60 and 180 seconds. All of the media were dissolved in other processing. There was little difference in the microwave irradiation level and surface temperature of the strain according to the processing time between Bacillus sp. and Burkholderia sp. In the sterility test according to the microwave irradiation level and processing time, it was confirmed that both Bacillus sp. and Burkholderia sp. grew in the microwave level 2 kW regardless of time. In the microwave level 6 kW, all experimental groups except the processing of Burkholderia sp. for 60 seconds were sterilized, and all of Bacillus sp. was killed in the all experimental groups. In the microwave level 8 kW, it was confirmed that both Bacillus sp. and Burkholderia sp. were sterilized regardless of time. The temperature in microwave-processed media after contaminating strains to each medium was maintained at more than 100 in polyurethane foam and rock wool medium after 60 seconds. In general, it was shown that it was possible to sterilize after 60 seconds. Therefore, it is considered that Bacillus sp. and Burkholderia sp. which are the biggest problems in the plant factory can be adequately sterilized by QRD Microwave used in this study.

Effect of Terephthalaldehyde to Facilitate Electron Transfer in Heme-mimic Catalyst and Its Use in Membraneless Hydrogen Peroxide Fuel Cell (테레프탈알데하이드의 전자전달 강화효과에 따른 헴 단백질 모방 촉매의 성능 향상 및 이를 이용한 비분리막형 과산화수소 연료전지)

  • Jeon, Sieun;An, Heeyeon;Chung, Yongjin
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.588-593
    • /
    • 2022
  • Terephthalaldehyde (TPA) is introduced as a cross liker to enhance electron transfer of hemin-based cathodic catalyst consisting of polyethyleneimine (PEI), carbon nanotube (CNT) for hydrogen peroxide reduction reaction (HPRR). In the cyclic voltammetry (CV) test with 10 mM H2O2 in phosphate buffer solution (pH 7.4), the current density for HPRR of the suggested catalyst (CNT/PEI/hemin/PEI/TPA) shows 0.2813 mA cm-2 (at 0.2 V vs. Ag/AgCl), which is 2.43 and 1.87 times of non-cross-linked (CNT/PEI/hemin/PEI) and conventional cross liker (glutaraldehyde, GA) used catalyst (CNT/PEI/hemin/PEI/GA), respectively. In the case of onset potential for HPRR, that of CNT/PEI/hemin/PEI/TPA is observed at 0.544 V, while those of CNT/PEI/hemin/PEI and CNT/PEI/hemin/PEI/GA are 0.511 and 0.471 V, respectively. These results indicate that TPA plays a role in facilitating electron transfer between the electrodes and substrates due to the π-conjugated cross-linking bonds, whereas conventional GA cross-linker increases the overpotential by interrupting electron and mass transfer. Electrochemical impedance spectroscopy (EIS) results also display the same tendency. The charge transfer resistance (Rct) of CNT/PEI/hemin/PEI/TPA decreases about 6.2% from that of CNT/PEI/hemin/PEI, while CNT/PEI/hemin/PEI/GA shows the highest Rct. The polarization curve using each catalyst also supports the superiority of TPA cross liker. The maximum power density of CNT/PEI/hemin/PEI/TPA (36.34±1.41 μWcm-2) is significantly higher than those of CNT/PEI/hemin/PEI (27.87±0.95 μWcm-2) and CNT/PEI/hemin/PEI/GA (25.57±1.32 μWcm-2), demonstrating again that the cathode using TPA has the best performance in HPRR.

Development and Validation of the Korean Wellness Scale (한국형 웰니스 척도(KWS) 개발 및 타당화)

  • Choi, Kyunghwa;Tak, Jinkook
    • The Korean Journal of Coaching Psychology
    • /
    • v.5 no.2
    • /
    • pp.127-170
    • /
    • 2021
  • This study developed a measure to measure wellness-seeking behavior in important areas of life for general adults in Korea and verified its validity. For the development of the wellness scale, 31 factors derived through literature review, expert interviews, in-depth interviews, open questionnaires 1 and 2, and 182 questions were selected as the final 10 factors and 99 questions. Through exploratory factor analysis of the results of the preliminary survey of 351 adults in Korea, 58 questions of 10 factors were derived, and some of the questions reflecting important concepts in each factor were revised, and this survey was conducted with 63 questions of 10 factors. In this survey conducted on 667 people, to verify the validity of the composition concept of this test, the entire sampling was divided into two groups, one group was subjected to exploratory factor analysis, and the other group was subjected to confirmatory factor analysis. As a result of exploratory factor analysis, 63 questions of 10 factors (work, community, family, others, economic power, self-esteem, leisure, physical health, spirituality, and self-growth) were finally derived, and confirmatory factor analysis using the structural equation model verified that the model fit criteria were met. Convergence validity was verified using the K-MHC-SF and Wellness Index for Workers to verify whether the derived wellness scale and its sub-factors actually measure wellness. As a result of analyzing the relationship between the variables and factors of the Subjective Happiness Scale and Life Scale to verify the validity related to the criteria, it was found to be a significant correlation. As a result of confirming the significance of each path through multiple regression analysis, the 'self-esteem' on the wellness scale was identified as the most important factor influencing subjective happiness and life satisfaction. Finally, discussions on this research process and results, academic significance and practical significance, limitations, and future research directions were presented.

  • PDF

Correlation between Corneal Ablation Amount and Intraocular Pressure after Corneal Refractive Surgery (각막굴절교정수술 후 각막절삭량과 안압변화의 상관관계)

  • Jung, Mi-A;Lee, Eun-Hee
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.543-551
    • /
    • 2018
  • Purpose : The purposes of this study were to evaluate the changes of intraocular pressure according to corneal ablation amount after corneal refractive surgery and the changes of intraocular pressure according to refractive errors before corneal refractive surgery. Methods : The mean age of adults who underwent LASIK corneal refractive surgery were $37.34{\pm}7.42years$, and 108 adults(48 males, 60 females) were participated in this study. Refractive errors, intraocular pressure, and corneal ablation amount were measured using an autorefractor, a noncontact tonometer, and an excimer laser. All test values were considered statistically significant when p<0.05. Results : The mean intraocular pressure before corneal refractive surgery was $15.08{\pm}2.60mmHg$ in males and $14.16{\pm}2.67mmHg$ in females. The decrease of intraocular pressure after corneal refractive surgery were 4.22mmHg in males and 3.61mmHg in females. Spherical equivalent power were $-3.89{\pm}2.17D$ in males and $-4.45{\pm}2.92D$ in females before corneal refractive surgery, and $-0.10{\pm}0.46D$ in males and $-0.04{\pm}0.46D$ in females after corneal refractive surgery. The corneal ablation amount after corneal refractive surgery were statistically significant, with $53.95{\mu}m$ in males and $61.26{\mu}m$ in females. There was significant correlation between corneal ablation amount and decrease of intaocluar pressure(r=0.2299, p<0.001). As the growth of corneal ablation amount in males, the decrease of intraocular pressure was significantly increased. As the growth of refractive error, the amount of decrease in intraocular pressure was also significant. The decrease of intraocualr pressure were $3.04{\pm}2.18mmHg$ in low refractive error, $4.10{\pm}2.16mmHg$ in middle refractive error, and $4.65{\pm}3.29mmHg$ in high refractive error. Conclusion : We found that intraocular pressure decreased after corneal refractive surgery by noncontact tonometer and the change of intraocular pressure which is an important index for glaucoma diagnosis, may affect the judgment of eye disease. We think that a preliminary questionnaire whether corneal refractive surgery is necessary for the measurement of intraocular pressure.

The Effects of the Change of Operating Income Disclosure Policy under K-IFRS - Evidence from KOSDAQ Market - (K-IFRS 이후 영업이익 공시정책의 변화에 대한 연구 - 코스닥 시장을 중심으로 -)

  • Baek, Jeong-Han;Choi, Jong-Seo
    • Management & Information Systems Review
    • /
    • v.33 no.3
    • /
    • pp.167-187
    • /
    • 2014
  • While Korean GAAP had detailed regulations for the measurement and disclosure of operating income in the past, K-IFRS did not provide specific rules for operating income until 2011. Some firms that adopted K-IFRS before 2011 did not disclose or calculated operating income in an inconsistent manner although operating income is usually considered as one of the core information items to assess firm valuation. Inconsistency in firms' treatment of operating income invoked much criticism from diverse users of financial statement. The Korean Accounting Institute (KAI hereafter) revised the K-IFRS rules relevant to operating income in September 2010 in response to the voices raised by the business community, whereby the operating income number is allowed to be calculated in conformity with the previous K-GAAP. This study was motivated by the revision of K-IFRS and aims to provide a clue on the validity of such policy decision. To achieve the research objective, we test the relative value relevance of the alternative operating income numbers under K-IFRS versus K-GAAP. Our main findings are as follows. The value relevance of operating income reported before K-IFRS is proved to be higher than after K-IFRS. K-IFRS operating income adjusted to the previous K-GAAP has greater explanatory power for market values relative to one calculated under the K-IFRS regime. In an additional analysis, the sample was decomposed according to whether the operating income under K-IFRS is greater than under K-GAAP. The difference in the value relevance of K-IFRS versus K-GAAP operating income is significant only in the subsample consisting of firms which reports higher operating income under K-IFRS compared to K-GAAP. Also, the firms which would have reported negative operating income on a consecutive basis are more likely to have chosen K-IFRS, resulting in higher numbers than otherwise. It is likely that firms facing the threat of delisting due to consecutive operating loss reporting are more likely to have adopted K-IFRS disclosure rules by which they could report higher operating income numbers. To sum up, these results corroborate the limitation inherent in the K-IFRS regarding operating income disclosures. This paper suggests that the recent revision of K-IFRS implemented by KAI is likely to mitigate some of afore-mentioned limitations effectively.

  • PDF