Load Frequency Control of Multiarea Power System Based on Fuzzy Inference Technique (퍼지 추론을 이용한 다지역 계통의 부하주파수제어)

  • Chung, D.I.;Joo, S.M.;Lee, J.T.;Lee, K.S.;Chung, H.H.;Kim, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.118-121
    • /
    • 1992
  • This paper presents an optimal Fuzzy Control Technique to control the load frequency control of multiarea power system with a given stepwise load disturbance. The related simulation results show that the optimized fuzzy control technique are more effective than the conventional control technique (TBC, Optimal Control and etc) for reduction of load frequency deviation in transient and stedy-state, and for minimization of settling time.

  • PDF

Load Frequency Control of Power System using Self Organizing Fuzzy Controller (자기조직화적 퍼지제어기를 이용한 전력계통의 부하주파수제어)

  • Lee, J.T.;Chung, D.I.;An, B.C.;Joo, S.M.;Chung, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.23-25
    • /
    • 1993
  • This paper presents a design technique of self-organizing fuzzy controller using a learning method of fuzzy inference rule by a gradient method for load frequency control of power system. The membership functions in antecedent part and in consequent part of fuzzy inference rules are tuned by the gradient method. The related simulation results show that the proposed fuzzy controller are more powerful than the conventional ones for reduction of undershoot and deviation of load frequency in steady-state, and for minimization of settling time.

  • PDF

CMOS High Speed Input Offset Canceling Comparator Design with Minimization of Charges Transfer (유동 전하량 최소화를 통한 입력 오프셋 제거 CMOS 고속 비교기의 설계)

  • 이수형;신경민;이재형;정강민
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.963-966
    • /
    • 1999
  • This Paper describes the design of high speed and low power comparator based on the feed forward bias control. Major building blocks of this comparator are composed of input offset canceling circuit and feed forward bias control circuit. The usual offset canceling circuit cancels the offset voltages by storing them in capacitors using MOS switches, The comparator of this paper employs the bias control circuit which generates bias signal from the input signal. The bias signal is applied to the capacitors and keeps the transfer of chares in the capacitors in the minimal amount, therefore making the comparator operate in stable condition and reduce decision time. The comparator in this form has very samll area and power dissipation. Maximum sampling rate is 200 Ms/sec. The comparator is designed in 0.65${\mu}{\textrm}{m}$ technology and the offset is less than 0.5㎷.

  • PDF

Fuzzy-GA Application for Allocation and Operation of Dispersed Generation Systems in Composite Distribution Systems (복합배전계통에서 분산형전원의 설치 및 운영을 위한 Fuzzy-GA 응용)

  • 김규호;이유정;이상봉;유석구
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.10
    • /
    • pp.584-592
    • /
    • 2003
  • This paper presents a fuzzy-GA method for the allocation and operation of dispersed generator systems(DGs) based on load model in composite distribution systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load. The problem formulation considers an objective to reduce power loss of distribution systems and the constraints such as the number or total capacity of DGs and the deviation of the bus voltage. The main idea of solving fuzzy goal programming is to transform the original objective function and constraints into the equivalent multi-objectives functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm. The method proposed is applied to IEEE 12 bus and 33 bus test systems to demonstrate its effectiveness. .

Optimal Power Flow Considering Price Elasticity of Customer (소비자의 가격탄력성을 고려한 최적조류계산)

  • Joung, Sang-Houn;Shin, Young-Gyun;Kim, Bal-Ho H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.372-374
    • /
    • 2002
  • The Optimal Power Flow(OPF) is the optimization model that has different constraints and the specified objective function, which is very useful tool for efficient system and market operation in the competitive electricity market. The existed OPF models focus on the minimization of generation fuel cost under informed demand values at each bus Recently, the studies of OPF model with demand function considering the response behavior of customers in the deregulated electricity market have been executed. This paper implements the OPF model using demand function with specified price elasticity, and provides the analysis of related results.

  • PDF

Design of PWM Inverter-Mounted Induction Motor System (PWM 인버터 탑재형 유도전동기 시스템 설계)

  • Shin, Woo-Seok;Yang, Soon-Bae;Lee, Don-Si;Choe, Gyu-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.325-329
    • /
    • 1994
  • This paper describes a compact design and control method of PWM inverter-mounted induction motor especially designed for reducing the size and weight considerably, which may be applied to the speed control system such as air conditionr,conveyor and textile mill, etc. To obtain higher power density without derating performance, a new mechanical configuration unifying the inverter circuit and motor is proposed. Also, through the use of current minimization control method during V/f operation it is possible to reduce the size of heat-sink related to the losses of power circuit. By the proposed design method, a compact inverter-mounted induction motor system of 1Hp is built and its validity can be verified through the experimental results.

  • PDF

Condition Monitoring System: High Performance Wireless Measurement System (기계 상태 감시: 임베디드형의 고성능 무선 측정시스템)

  • Shim, M.C.;Yang, B.S.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.28-32
    • /
    • 2007
  • This research proposed that development of wireless condition monitoring system using WLAN network. It offers the prospect of improved performance that removed a current a coaxial cable and reduced overall cost of condition monitoring. Recently, there is an interesting concern for wireless system as an infrastructure technology construct ubiquitous computing environment in the future. High performance computing board makes minimization with integrate of a various functions which support wireless LAN network. Instead of wired coaxial cable using measurement system in industry, wireless LAN network assists industry automation and engineer's convenience. Developed system adapted wireless LAN network on shipboard with engine room and deck house, it also executes wireless measurement test on 8500TEU containership.

  • PDF

Optimization of PI Controller Gain for Simplified Vector Control on PMSM Using Genetic Algorithm

  • Jeong, Seok-Kwon;Wibowo, Wahyu Kunto
    • Journal of Power System Engineering
    • /
    • v.17 no.5
    • /
    • pp.86-93
    • /
    • 2013
  • This paper proposes the used of genetic algorithm for optimizing PI controller and describes the dynamic modeling simulation for the permanent magnet synchronous motor driven by simplified vector control with the aid of MATLAB-Simulink environment. Furthermore, three kinds of error criterion minimization, integral absolute error, integral square error, and integral time absolute error, are used as objective function in the genetic algorithm. The modeling procedures and simulation results are described and presented in this paper. Computer simulation results indicate that the genetic algorithm was able to optimize the PI controller and gives good control performance of the system. Moreover, simplified vector control on permanent magnet synchronous motor does not need to regulate the direct axis component current. This makes simplified vector control of the permanent magnet synchronous motor very useful for some special applications that need simple control structure and low cost performance.

Investigating Buck DC-DC Converter Operation in Different Operational Modes and Obtaining the Minimum Output Voltage Ripple Considering Filter Size

  • Babaei, Ebrahim;Mahmoodieh, Mir Esmaeel Seyed;Sabah, Mehran
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.793-800
    • /
    • 2011
  • This paper investigates the operational modes of buck dc-dc converters and their energy transmission methods. The operational modes of such converters are classified in two types, discontinuous conduction mode (DCM) and continuous conduction mode (CCM). In this paper, the critical inductance relation of DCM and CCM is determined. The equations of the output voltage ripple (OVR) for each mode are obtained for a specific input voltage and load resistance range. The maximum output voltage ripple (MOVR) is also obtained for each mode. The filter size is decreased and the minimum required inductance value is calculated to guarantee the minimization of the MOVR. The experimental and simulation results in PSCAD/EMTDC prove the correctness of the presented theoretical concepts.

Evaluation of the Performance Characteristics of Propane/isobutene Refrigerant Mixtures in a Small multi-refrigeration System (프로판/이소부탄 혼합냉매를 적용한 가정용 소형 멀티 냉동시스템의 성능특성에 관한 연구)

  • Lee, Moo-Yeon;Choi, Seok-Jae;Kim, Sang-Ok
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1945-1950
    • /
    • 2004
  • In this paper, The performance of Kim-Chi refrigerator with three evaporator and one compressor was investigated in employing 55% propane and 45% isobutane (R290/R600a) refrigerant mixture as an alternative refrigerant of R134a. The drop in test was performed by varying both refrigerant charge amount and capillary tube length in order to find both the performance and reliability of a small multi-refrigeration system. As a result, Both the power consumption and COP is increased by about 15% and 10%, respectively as compared to the baseline R134a system. In addition, the propane/isobutene refrigerant mixture system took advantage of the minimization of modification and redesigning of system components because of similar thermodynamic properties with R134a such as saturation pressure, temperature, normal boiling point(NBP) characteristics