• Title/Summary/Keyword: power loss measurement system

검색결과 101건 처리시간 0.025초

원자력발전소 전력케이블 부분방전 진단 사례 (Partial Discharge Measurement of Power Cables for Nuclear Power Plant)

  • 하체웅;주광호;임우상
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1632-1638
    • /
    • 2011
  • Electric cables are one of the most important components in a nuclear power plant since they provide the power needed to operate electrical equipment. Despite their importance, cables typically receive little attention since they are considered passive, long-lived components that have been very reliable over the years when subjected to the environmental conditions for which they were designed. The operating experience reveals that a defect of the insulator or poor construction causes the initial failure of cable. However, the number of cable failures increase with plant aging, and these cable failures are occurring within the plants' 40-year licensed period. These cable failures have resulted in plant transients, shutdown, loss of safety functions or redundancy, entries into limiting conditions for operation, and challenges for plant operators. Therefore, diagnosis of MV cable installed in NPPs has become one of the most urgent issues in recent years. In accordance with PSR, condition maintenance for cables is also continuously required. Recently, HFPD tests have been widely performed to diagnose cable in the transmission and distribution cable system. However, on-line HFPD wasn't used in the NPPs because of the danger of plant shutdown, measurement sensitivity and application problems, etc. In this paper, HFPD measurement with portable device was performed to evaluate the integrity of the 4.16kV & 13.8kV cable lines. The test results show that HFPD is highly attractive to the diagnosis of MV cables in NPP by high detection sensitivity on-site.

GSM 모듈을 탑재한 HPC(Handheld PC)에서의 오디오 노이즈 개선에 관한 연구 (The Study on Improvement of Audio Noise When 900MHz GSM Cellular Phone Built in HPC(Handheld PC))

  • 박희봉;장복현;황금찬;박용서
    • 한국통신학회논문지
    • /
    • 제24권8A호
    • /
    • pp.1169-1178
    • /
    • 1999
  • 본 논문에서는 현재 유럽에서 데이터와 음성 서비스를 하고 있는 GSM(Global System for Mobile Communication)용 디지털 단말기를 Handheld PC에 빌트인 할 경우 나타나는 오디오 노이즈의 개선 방법을 제시하고 있다. 서비스 가운데 가장 큰 문제인 음성 품질을 GSM규격 항목에 만족하기 위해서는, HPC 메인보드에서 전원 그리운드와 가장 가깝고 면적이 가장 넓은 부분을 중심으로 선택하여 GSM모듈과 와이어를 직접 연결하여 임피던스 차이를 최소로 하고, 전치 증폭기와 Earpiece에 있어서는 본 논문에서 제시한 Low Noise 설계를 통하여, 오디오 노이즈를 개선하였다. 측정 결과는 GSM 음성(Acoustic)규격을 만족한다. 측정결과는 B&K Type 6712(GSM 전용장비)를 이용하여 GSM 11.10 ETS 300 607-1의 음성(Acoustic)규격 항복을 측정하였다. 본 연구에서 측정한 항목으로는 다음의 Sending Sensitivity Frequency Response and SLR, Sending Loudness Rating(SLR level), Receiving Sensitivity Loudness Rating(RLR level), Talker Sidetone(STMR), Stability Margin, Echo Return Loss(ERL)으로 6가지 항목이다.

  • PDF

HPA MMIC to W/G Antenna Transition Loss Analysis and Development Results of W-band Transmitter Module

  • Kim, Wansik;Jung, Juyong;Lee, Juyoung;Kim, Jongpil
    • International Journal of Advanced Culture Technology
    • /
    • 제7권4호
    • /
    • pp.236-241
    • /
    • 2019
  • This paper will read about a multichannel frequency-modulated continuous wave (FMCW) radar sensor with switching transmit (TX) antennas is developed at W-band. To achieve a high angular resolution, a uniform linear array consisting of 5 switching-TX and 12 receive (RX) antennas is employed with the digital beamforming technique. The overall radar front-end module comprises a W-band transceiver and TX/RX antennas. A multichannel transceiver module consists of 5 up-conversion and 12 down-conversion channels, where one of the TX channels is sequentially switched ON. For developing transmitter, we developed an HPA (high power amplified) MMIC chip for W-band radar system and fabricated a transmitter module using this chip. In order to develop the W-band transmitter, we analyzed the important antenna transition structure from HPA MMIC line to W/G (Waveguide)antenna via M/S(microstrip) and fabricated it with 5 transmission channels. As a result, the output power of the transmitter was within 1 dB of the error range after analysis and measurement under normal temperature and environmental conditions.

RLSM을 이용한 안구운동의 저속도 측정방법에 대한 연구 (A Method for Slow Component Velocity Measurement of Nystagmus Eye Movements using RLSM)

  • 김규겸;고종선;박병림
    • 전력전자학회논문지
    • /
    • 제7권6호
    • /
    • pp.546-553
    • /
    • 2002
  • 일상 생활에서 인간의 자세와 운동은 전정기관, 시각, 고유수용체에 의해 조절되어진다. 특히 전정기관은 정전안구반사를 통한 안구 운동과 전정척수반사를 통한 골격근의 수축 운동을 제어하는 매우 중요한 기능을 갖고 있다. 그러나 자세 조절기능의 손실로 인한 자세 부조화는 오심, 구토, 현기증을 초래하여 삶의 의욕을 상실케 만들고 안진이라 불리는 비정상적인 안구반사운동을 초래한다. 현기증 진단에 EOG를 이용한 안진의 분석이 필요하다. 본 연구의 목적은 데이터 처리를 위한 컴퓨터 시스템과 OKN 시뮬레이션 시스템에 의해 유발된 안진 서상속도의 자동평가 알고리즘을 개발하는데 있다. 본 논문에서는 RLSM을 이용하여 안진의 서상속도를 검출하는 새로운 알고리즘을 제안하였다. 이 방법은 눈 깜빡임과 같은 artifact에 둔감하여 안진의 빠르고 정확한 평가가 가능하다.

Complete and Incomplete Observability Analysis by Optimal PMU Placement Techniques of a Network

  • Krishna, K. Bala;Rosalina, K. Mercy;Ramaraj, N.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1814-1820
    • /
    • 2018
  • State estimation of power systems has become vital in recent days of power operation and control. SCADA and EMS are intended for the state estimation and to communicate and monitor the systems which are operated at specified time. Although various methods are used we can achieve the better results by using PMU technique. On placing the PMU, operating time is reduced and making the performance reliable. In this paper, PMU placement is done in two ways. Those are 'optimal technique with pruning operation' and 'depth of unobservability' considering incomplete and complete observability of a network. By Depth of Unobservability Number of PMUs are reduced to attain Observability of the network. Proposed methods are tested on IEEE 14, 30, 57, SR-system and Sub systems (1, 2) with bus size of 270 and 444 buses. Along with achieving complete observability analysis, single PMU loss condition is also achieved.

Concept Development of a Simplified FPGA based CPCS for Optimizing the Operating Margin for I-SMRs

  • Randiki, Francis;Jung, Jae Cheon
    • 시스템엔지니어링학술지
    • /
    • 제17권2호
    • /
    • pp.49-60
    • /
    • 2021
  • The Core Protection Calculator System (CPCS) is vital for plant safety as it ensures the required Specified Acceptance Fuel Design Limit (SAFDL) are not exceeded. The CPCS generates trip signals when Departure from Nucleate Boiling Ratio (DNBR) and Local Power Density (LPD) exceeds their predetermined setpoints. These setpoints are established based on the operating margin from the analysis that produces the SAFDL values. The goal of this research is to create a simplified CPCS that optimizes operating margin for I-SMRs. Because the I-SMR is compact in design, instrumentation placement is a challenge, as it is with Ex-core detectors and RCP instrumentation. The proposed CPCS addresses the issue of power flux measurement with In-Core Instrumentation (ICI), while flow measurement is handled with differential pressure transmitters between Steam Generators (SG). Simplification of CPCS is based on a Look-Up-Table (LUT) for determining the CEA groups' position. However, simplification brings approximations that result in a loss of operational margin, which necessitates compensation. Appropriate compensation is performed based on the result of analysis. FPGAs (Field Programmable Gate Arrays) are presented as a way to compensate for the inadequacies of current systems by providing faster execution speeds and a lower Common Cause Failure rate (CCF).

The Fabrication of Micro-Heaters with Low-Power Consumption Using SOI and Trench Structures

  • 정귀상;홍석우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계합동학술대회 논문집
    • /
    • pp.197-201
    • /
    • 2002
  • This paper presents optimized design, fabrication and thermal characteristics of micro-heaters for thermal MEMS (micro electro mechanical system) applications using SOI and trench structures. The micro-heaters are based on a thermal measurement principle and contains thermal isolation regions of 10 ${\mu}m$-thick Si membranes consisting of oxide-filled trenches in the SOI membrane rim. The micro-heaters were fabricated with Pt-RTD on the same substrate via MgO buff layer between Pt thin-film and $SiO_2$ layer. The thermal characteristics of micro-heater with trench-free SOI membrane structure was $280^{\circ}C$ at input power 0.9 W; in the presence of 10 trenches, it was $580^{\circ}C$ due to reduction of the external thermal loss. Therefore, a micro-heater with trenches in SOI membrane rim structure provides a powerful and versatile alternative technology for enhancing the performance of micro-thermal sensors and actuators.

  • PDF

주거용 건물 태양광발전시스템의 설치유형에 따른 발전성능 평가 (Evaluation of Electricity Generation According to Installation Type of Photovoltaic System in Residential Buildings)

  • 김덕성;김법전;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제37권2호
    • /
    • pp.35-45
    • /
    • 2017
  • The types of installation of the photovoltaic system applied to domestic residential buildings are classified as follows: Mounted modules with air circulation, semi-integrated modules with air duct behind, integrated modules with fully insulated back. In order to study generation characteristics of PV system, we verified the validity of interpretation program based on long-term measurement data of demonstration house installed in BAPV form and also analyzed the generation characteristics and performance of each installation type. The results are as follows. First, the RMSE of amount of generation and simulation according to annual daily insolation of demonstration system located in Daejeon was 0.98kWh and the range of relative error of monthly power generation was -5.8 to 3.1. Second, the average annual PR of mounted modules was 82%, semi-integrated modules 76.1% and integrated modules 71.9%. This differences were attributed to temperature loss. Third, the range of operating temperature of annual hourly photovoltaic modules was -6.5 to $61.0^{\circ}C$ for mounted modules, $-6.0{\sim}73.9^{\circ}C$ for semi-integrated modules and -5.5 to $88.9^{\circ}C$ for integrated modules. The temperature loss of each installation type was -14.0 to 16.1%, -13.8 to 21.9%, and -13.6 to 28.5%, respectively.

석탄-바이오매스 혼소에 따른 슈퍼히터 튜브 고온 부식 특성 연구 (High-Temperature Corrosion Characterization for Super-Heater Tube under Coal and Biomass Co-firing Conditions)

  • 박석균;목진성;정진무;오종현;최석천
    • 동력기계공학회지
    • /
    • 제22권1호
    • /
    • pp.79-86
    • /
    • 2018
  • Many countries have conducted extensive studies for biomass co-firing to enhance the durability of reactor on high-temperature corrosion. However, due to the complicated mechanisms of biomass co-firing, there have been limitations in accurately determining the current state of corrosion and predicting the potential risk of corrosion of power plant. In order to solve this issue, this study introduced Lab-scale corrosion system to analyze the corrosion characteristics of the A213 T91 material under the biomass co-firing conditions. The corrosion status of the samples was characterized using SEM/EDS analysis and mass loss measurement according to various biomass co-firing conditions such as corrosion temperature, $SO_2$ concentration, and corrosion time. As a result, the corrosion severity of A213 T91 material was gradually increased with the increase of $SO_2$ concentration in the reactor. When $SO_2$ concentration was changed from 0 ppm to 500 ppm, both corrosion severity and oxide layer thickness were proportionally increased by 15% and 130%, respectively. The minimum corrosion was observed when the corrosion temperature was $450^{\circ}C$. As the temperature was increased up to $650^{\circ}C$, the faster corrosion behavior of A213 T91 was observed. A213 T91 was observed to be more severely corroded by the effect of chlorine, resulting in faster corrosion rate and thicker oxide layer. Interestingly, corrosion resistance of A213 T91 tended to gradually decrease rather than increases as the oxide layer was formed. The results of this study is expected to provide necessary research data on boiler corrosion in biomass co-firing power plants.

초전도체 자화특성 측정을 위한 실험장치의 구축 및 그 동작 특성 (Setup and Operating Characteristics of the Experimental Apparatus for Magnetization Measurements of Sperconductor)

  • 최세용;나완수;주진호
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제1권2호
    • /
    • pp.30-36
    • /
    • 1999
  • Superconductors are dissipative when exposed to time-varying magnetic fields. To analyze the AC characteristics of a superconductor, one usually needs to know magnetization curves of it. Good magnetization curves can be obtained only in homogeneous magnetic filed. In This paper, we report the setup and test results of a magnetization measurement system, which consists mainly of frequency-variable power supply and homeogenous magnet with 7-cm long air gap. Special emphasis are foused on the design and fabrication of the magnet, which aims to give background magnetic fields, and on the overall characteristics of the system.

  • PDF