• 제목/요약/키워드: power line signal

검색결과 641건 처리시간 0.027초

전기 철도의 전력선 통신을 위한 전차선과 조가선의 통신 특성 분석 (Analysis of Communication Characteristics on Contact wire and Messenger wire of Electric Railroad for Power Line Communication)

  • 이희준;안승호;강승욱;이종구
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.157-162
    • /
    • 2010
  • Power line communication, using 25[kV] high voltage of railway catenary, is to provide information which is real-time safety information for train operations and train workers in driving. Lots of noise were occupied in the contact wire by electrical and communication equipments. A signal attenuation was caused characteristics of the contact wire and messenger wire. For relaying communications to transmit information using the contact wire, catenary the noise and signal attenuation were investigated. And the final goal of the study was realized to transmit video information by power line communication on electric railway.

Hybrid coupler와 delay line을 사용한 PSK 변조 신호발생 회로해석 (Analysis of PSK modulation signal generation circuit using hybrid coupler and delay line)

  • 반경식;김영완
    • 한국정보통신학회논문지
    • /
    • 제13권2호
    • /
    • pp.227-232
    • /
    • 2009
  • 본 논문에서는 quadrature hybrid coupler를 사용하여 위상 변조 신호를 발생 할 수 있는 간단한 회로를 해석한다. 90o 위상차를 갖는 coupler 출력 단자의 반사 계수를 이용하여 일정한 위상 출력 값을 갖는 위상 변조 신호를 발생시키며, quadrature hybrid coupler와 지연 소자 그리고 전력 결합기 등 제안 구조를 사용하여 고차 PSK 신호를 발생할 수 있다. 하나의 90o hybrid coupler와 반사 소자에 의해 180o 위상차를 갖는 간단한 BPSK 신호 발생회로와 부가적인 지연 소자 및 전력 결합기에 의해 90o 위상차를 갖는 QPSK 신호를 발생한다. 모의 성능 실험 결과 3o 이내의 위상차를 갖는 양호한 PSK 신호 특성을 나타내었다.

전력선 통신기술을 이용한 조명제어 스위치의 개발 (Development of a Lighting Control Switch Using Power Line Communication Technology)

  • 송재용;서황동;문승보;길경석
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.299-303
    • /
    • 2005
  • A lighting control switch, extended to incorporate a power line communication technology, is developed. The system uses not an exclusive microprocessor but a general one, and developed PPM protocol. The coupling circuit is a type of an isolation LC filter, and the impedance of the circuit was designed as low as possible to extend signal transmission distance. The frequency of the carrier, considering the data length and signal attenuation as the length of power lines, was set at 250 kHz. Tests on a prototype in an indoor power lines have shown that the switch has a stable operation with the distance of power lines

  • PDF

전력선 통신 채널의 시물레이터 개발 (DEVELOPMENT OF SIMULATOR FOR POWER LINE COMMUNICATION CHANNEL)

  • 박종연;정동열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3114-3116
    • /
    • 1999
  • We have developed the power line simulator which is one of the basic tools for the research of the power line communication and the control system. In the developed simulators, we have considered the transfer characteristics of the power line, various noise characteristics, and signal attenuation characteristics.

  • PDF

전력선 반송통신을 이용한 전기기기 전원 제어 시스템에 관한 연구 (A Study on the Power Line Control System for Electric Machinery using Power Line Communication)

  • 김경엽;문복산;김영일;서인호;천행춘;강대기;유영호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2000년도 추계학술대회 논문집(Proceeding of the KOSME 2000 Autumn Annual Meeting)
    • /
    • pp.115-122
    • /
    • 2000
  • Recently, a study on the Power Line Communication has been done by many companies and institutes due to its own merits that we can use the power line as a communication channel. But, there are serious problems about the harsh and unpredictable characteristics - noise, signal distortion and attenuation to be overcome in order that we commercialize the Power Line Communication. In this paper, we analyse the power line characteristics and apply the technology of PLC to control power of electric machinery by using ASK modulation.

  • PDF

A Method for Fault detecting on Power Transmission Network by use of M-sequence Correlation

  • Nishiyama, Eiji;Kuwanami, Kenshi;Owaki, Kosuke
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2570-2575
    • /
    • 2003
  • Monitoring a power transmission line is significant for power electric companies. In this paper, we propose a new method for detecting an fault point of power transmission line by use of M-sequence correlation technique. In this method, detecting signal is used as one or plural M-sequences ( same characteristic polynomial, including normal and reverse mark, synchronized ). In receiving point, we make same sequence with the input one and take crosscorrelation function between M-sequence and the received signal. We can see transfer fanctions of plural paths between inputs and a output taps separated from different of delay times on the crosscorrelation function, and from these transfer fanctions, so we compare them when fault occurred with in usual.

  • PDF

무정전전원장치의 병렬운전 제어기법에 관한 연구 (A Study on the Parallel Operation Control Technique of On-line UPS System)

  • 곽철훈;최규하
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.585-592
    • /
    • 2003
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between Inverters on synchronous d-q reference frame.

등가 전력선을 가진 Chua 회로에서의 카오스 비밀통신 (Chaos Secure Communication using Chua Circuit with Equivalent Power Lines)

  • 배영철
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.263-266
    • /
    • 2000
  • In this paper, we formed a transmitter and receiver by using two identical Chua's circuits and then formed wireless transmission line from the channel which was between those two circuits. We proposed a secure communication method in which the desired information signal was synthesized with the chaos signal created in a Chua's circuit and sent to the transmitter through channel. Then the signal was demodulated receiver of Chua's circuit. The method we used to accomplish the sun communication was synthesizing the desired information with the chaos circuit by parallel connection in a wireless transmission line. After transmitting the synthesized signal to the wireless transmission line, we confirmed the actuality of the secure communication by separating the information signal and the chaos signal in the receiver. In order to confirm the security, we compared the wiretapped signal and the recovery signal under the assumption that the wiretapping had taken place. In order to separate the two signals, we transformed the information signal to a current source in the transmitter and detected the current in the receiver.

  • PDF

통신 채널로써 전력선 시뮬레이터 개발 (Power Line Simulator Development for Communication Channel)

  • 박종연;정동열
    • 산업기술연구
    • /
    • 제19권
    • /
    • pp.81-89
    • /
    • 1999
  • We have developed a power line simulator which is one of the basic tools for the research of the power line communication and its control system. In the developed simulators, we have considered the transfer function of the power line, noises and signal attenuation characteristics. Simulator was made using the matlab tool program. We made the power line modern using the FSK chip(ST7537) and experimentalized to show the efficiency grade of simulator. We have expected that the developed simulators are very useful in the area for the power line communication research and the control system design.

  • PDF

전력선 통신채널의 시뮬레이터 개발 (Simulator Development for Power Line Communication Channel)

  • 박종연;정동열
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제49권9호
    • /
    • pp.546-553
    • /
    • 2000
  • W e have developed a power line simulator which is one of the basic tools for the research of the power line communication and its control system. In the developed simulators, we have considered the transfer function of the power line, noises and signal attenuation characteristics. Simulator was made using the matlab tool program. We made the power line modem using the FSK chip(ST7537) and experimentalized to show the efficiency grade of simulator. We have expected that the developed simulators are very useful in the area for the power line communication research and the control system design.

  • PDF