• Title/Summary/Keyword: power level

Search Result 7,398, Processing Time 0.042 seconds

Analysis. Design and Control of Two-Level Voltage Source Converters for HVDC Systems

  • Mohan, D. Madhan;Singh, Bhim;Panigrahi, B.K.
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.248-258
    • /
    • 2008
  • The Voltage Source Converter (VSC) is replacing the conventional line commutated current source converters in High Voltage DC (HVDC) transmission systems. The control of a two-level voltage source converter and its design dealt with HVDC systems and various factors such as reactive power, power factor, and harmonics distortion are discussed in detail. Simulation results are given for the two-level converter and designed control is used for bidirectional power flow. The harmonics minimization is taken by extending the 6-pulse VSC to multipulse voltage source converters. The control is also tested and simulated for a 12-pulse voltage source converter to minimize the harmonic distortion in AC currents.

Sound Power Evaluation of Various Domestic Railroad Vehicles (국내 철도 차량의 음향발생 특성에 대한 비교 연구)

  • Kim, Jeung-Tae;Cho, Sung-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.2 no.1
    • /
    • pp.28-37
    • /
    • 1999
  • Many residential areas are situated near to railroad tracks so that a railroad noise has been one of the major environmental issues. In this paper two important aspects have been investigated in order to properly evaluate the railroad vehicle noise : sound power levels for different types and sound propagation characteristics of the railroad vehicles. For noise source characteristics of railroad vehicles, sound power values for various types of trains that are in active service have been measured. In this paper, domestic railroad vehicles are measured and compared with high speed train(TGV). Based on sound power information of railway vehicles, prediction on the sound pressure level and equivalent noise level near to railway areas have been evaluated.

  • PDF

Determination of Optimum Pressurizer Level for Kori Unit 1

  • Song, Dong-Soo;Lee, Chang-Sup;Lee, Jae-Yong;Kim, Yo-Han;Lee, Dong-Hyuk
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.437-442
    • /
    • 1997
  • To determine the optimum pressurizer water level during normal operation for Kori unit 1, performance and safety analysis are peformed. The methodology is developed by evaluating "decrease in secondary heat removal" events such as Loss of Normal Feedwater accident. To demonstrate optimum pressurizer level setpoint, RETRAN-03 code is used for performance analysis. Analysis results of RETRAN following reactor trip are compared with the actual plant data to justify RETRAN code modelling, The results of performance and safety analyses show that the newly established level setpoints not only improve the performance of pressurizer during transient including reactor trip but also meet the design bases of the pressurizer volume and pressure. pressure.

  • PDF

Cascaded Multi-Level Inverter Based IPT Systems for High Power Applications

  • Li, Yong;Mai, Ruikun;Yang, Mingkai;He, Zhengyou
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1508-1516
    • /
    • 2015
  • A single phase H-bridge inverter is employed in conventional Inductive Power Transfer (IPT) systems as the primary side power supply. These systems may not be suitable for some high power applications, due to the constraints of the power electronic devices and the cost. A high-frequency cascaded multi-level inverter employed in IPT systems, which is suitable for high power applications, is presented in this paper. The Phase Shift Pulse Width Modulation (PS-PWM) method is proposed to realize power regulation and selective harmonic elimination. Explicit solutions against phase shift angle and pulse width are given according to the constraints of the selective harmonic elimination equation and the required voltage to avoid solving non-linear transcendental equations. The validity of the proposed control approach is verified by the experimental results obtained with a 2kW prototype system. This approach is expected to be useful for high power IPT applications, and the output power of each H-bridge unit is identical by the proposed approach.

Module Multilevel-Clamped Composited Multilevel Converter (M-MC2) with Dual T-Type Modules and One Diode Module

  • Luo, Haoze;Dong, Yufei;Li, Wuhua;He, Xiangning
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1189-1196
    • /
    • 2014
  • A modular multilevel-clamped composited multilevel converter ($M-MC^2$) is proposed. $M-MC^2$ enables topology reconfiguration, power device reuse, and composited clamping. An advanced five-level converter ($5L-M-MC^2$) is derived from the concept of $M-MC^2$. $5L-M-MC^2$ integrates dual three-level T-type modules and one three-level neutral point clamped module. This converter can also integrate dual three-level T-type modules and one passive diode module by utilizing the device reuse scheme. The operation principle and SPWM modulation are discussed to highlight converter performance. The proposed $M-MC^2$ is comprehensively compared with state-of-the-art five-level converters. Finally, simulations and experimental results are presented to validate the effectiveness of the main contributions of this study.

Multi-Level Operation with Two-Level Converters through a Double-Delta Source Connected Transformer

  • Park, Yongsoon;Ohn, Sungjae;Sul, Seung-Ki
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1093-1099
    • /
    • 2014
  • This paper proposes a power conversion topology involving a multi-winding transformer and converters. The fundamental idea is described with circuit diagrams, and the voltage output of the proposed topology is analyzed mathematically. The effectiveness of the topology is discussed with test results from a small-scale power conversion system. When conventional hardware consisting of two-level converters and a transformer is employed, multi-level voltage outputs can be applied to the transformer windings by the proposed method.

A Study on Turbine Auxiliary Devices in a Thermal Power Plant (화력발전소 터빈 보조기기 제어 관한 고찰)

  • Jeong, Chang-Ki;Choi, In-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1667-1668
    • /
    • 2008
  • There are three main devices such as boiler producing steam, turbine driving generator and generator producing electricity. An electrical generator in power plant is driven and maintained its speed at rated by steam turbine which is coupled into generator directly. Turbine auxiliary devices such as condenser, deaerator, feed water heater, gland steam condenser, pump recirculation equipment, feed water pump, and so on should be operated well so that the steam turbine exert its maximum efficiency. There are many control loop such as hot well level and condenser recirculation, deaerator level, pegging steam pressure, feed water heater level, feed water pump recirculation. In this paper condenser level control and deaerator level control are going to be described.

  • PDF

A winding design of Tap Level Converter (Tap Level 제어 전력 변환기의 권선설계)

  • Chun J.H.;Lee H.W.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.53-55
    • /
    • 2006
  • In this paper discusses winding methode of single phase AC-DC reversible power converter The reversible power converter driven by multi Tap winding at both side switching control. It has a advantage that simple drive of main switching device. and obtain load current of good quality without filter circuit and free from noise or isolation for lower switching frequency. In this research, study on current type converter and inverter circuit that consist for possibility of AC-DC/DC-AC multi-level reversible converter.

  • PDF

Development of a Method for Reliability Evaluation of Transmission System under the Deregulated Electricity Market (규제완화된 전력시장 하에서의 송전계통 신뢰도 평가방법의 개발)

  • Cha, Jun-Min;Kim, Hong-Sik;Choi, Jae-Seok;Oh, Kwang-Hae
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.397-399
    • /
    • 2000
  • This paper presents a method for assessing reliability indices of transmission system. Because successful operation of electric power under the deregulated electricity market depends on transmission system reliability management, quantity evaluation of transmission system reliability is very important. The key point idea is based on that the reliability level of transmission system is equal to reliability level difference of between composite power system(HLII) and generation system(HLI). It is sure that risk indices of reliability of composite power system are larger than those of generation system. It is the reason that composite power system includes uncertainties and capacity limit of transmission lines. The characteristics and effectiveness of this methodology are illustrated by the case study using MRBTS.

  • PDF

A Configuration of Superconducting Power System Considering the Current Level & Electric Insulation Coordination of Superconducting Apparatus (초전도기기 전류레벨협조와 절연협조를 고려한 초전도전력시스템구성을 위한 기초연구)

  • Hong, W.P.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1208-1210
    • /
    • 1999
  • Design & operation power systems for meeting increase of electric power demand is becoming more difficult and complex. Some of limitations of conventional technology can be broken through by the application of superconductivity technology. This paper presents a new concept & image for the configuration of superconducting power system which has introduced superconducting(SC) generator, cable, transformer, fault current limiter(SFCL), SMES, etc. Engineering evaluation of each power apparatus and its assessment of application to power system were conducted. Futhermore, it is pointed that superconducting power system require a new operating condition. This is, SFCL should play a important part of quenching current level coordination to prevent the other superconducting devices from quenching. Its designing & operating condition including SFCL was discussed in viewpoint of quenching current level and insulation coordination of SC coil.

  • PDF