• Title/Summary/Keyword: power coupler

Search Result 326, Processing Time 0.028 seconds

A Study on the phase angle detection of power source for PWM converter based on PLL method (PLL기법에 기반한 PWM 컨버터 전원 위상각 검출에 관한 연구)

  • Choi Cheol;Lee Sang-Hun;Kim Cheol-U
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.284-288
    • /
    • 2005
  • This paper proposes the direct detection method of phase angle for the power source, which is based on the PLL method. The proposed method using a bidirectional photo-coupler is used to directly detect the zero crossing of phase voltage and calculate the angular frequency in the controller based on a M/T algorithm. Through the method, the additional installation space in the traditional method using a potential transformer can be minimized and it can be easy to design. The paper presents straightforward schematic circuits, design and experimental results.

  • PDF

Design and Test of Communication Between Data Concentrator Units for Efficient AMI(Advanced Metering Infrastructure) System (효율적 원격검침시스템 구축을 위한 집중장치간 연계통신 방법 설계 및 성능 테스트)

  • Im, Eun-Hye;Park, Byung-Seok;Kim, Young-Hyun;Choi, In-Ji;Myoung, No-Gil
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2337-2343
    • /
    • 2010
  • AMR(Automatic Meter Reading)/AMI(Advanced Metering Infrastructure) is actively deployed all over the world. efficient, economical, stable and reliable system need to push forward the AMR/AMI business, so various researchs are in progress. In electric power system of domestic, a transformer is connected average twenty to thirty households and PLC is possible to communication within household connected same transformer. So if server and data concentrator unit(DCU) share circuit line through communication between transformers, communication network is able to efficient. Therefore we design new communication method between DCUs and test it and demonstrate the performance.

Characteristics of Insulation Aging in 4.16kV Motor Stator Windings (4.16kV 전동기 고정자 권선의 절연열화 특성)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1381_1382
    • /
    • 2009
  • Nondestructive tests were performed on two 4.16kV motors. Epoxy-mica coupler(80pF) was connected to 4.16 kV motor stator windings. The voltage applied to the stator windings was 2.4 kV, 3.0kV, 3.5kV and 4.16kV, respectively. Digital partial discharge detector(PDD) and turbine generator analyzer(TGA) were used to measure partial discharge(PD) activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of stator windings were indicated the internal discharge. PD patterns are consistent with the result of measurement using PDD and TGA.

  • PDF

A Design of Attaching the Antenna to USPCS Band FEM (USPCS 대역 FEM 부착 안테나 설계)

  • Gang, Sung-Won;Cheon, Chang-Yul;Kim, Jun-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.768-772
    • /
    • 2007
  • Integration of RF front end module(FEM) into the antenna has been investigated in USPCS band (1.88GHz-1.99GHz). The FEM consists of input filter, power amplifier, coupler, power detector, bias switch and duplexer. The antenna was designed in planar inverted F antenna(PIFA) structure to implement it inside the handset. In order to avoid strong coupling between the antenna and FEM, a shielding ground layer was placed between them. The antenna size is 19mm by 10mm by 6mm under which FEM whose size is 8mm by 5mm by 1.5m locates. The antenna impedance was selected to match to FEM having better efficiency rather than gain since FEM has enough gain whose system spec is minimum of 20dB. The antenna patterns are shown with and without FEM.

Wavelength-Swept Cascaded Raman Fiber Laser around 1300 nm for OCT Imaging

  • Lee, Hyung-Seok;Lee, Hwi Don;Jeong, Myung-Yung;Kim, Chang-Seok
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.154-158
    • /
    • 2015
  • We experimentally demonstrated a novel wavelength-swept laser using a cascaded Raman gain around 1310 nm. A 1064/1310 wavelength division multiplexing (WDM) coupler and coupled fiber Bragg gratings mirrors at 1064, 1117, 1175, 1240 nm are effectively used to increase the power efficiency in a laser ring cavity with highly non-linear fiber (HNLF) of 2 km. Linear wavelength sweeping is demonstrated with the 100 Hz triangular driving signal to fiber Fabry-Perot tunable filter (FFP-TF) around the 1310 nm region. The measured sweeping range and output power were 27 nm and 2.1 mW, respectively, which are suitable for optical coherence tomography (OCT) imaging.

Development of a New Active Phase Shifter

  • Kim, S.J.;N.H. Myung
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.1063-1066
    • /
    • 2000
  • ln this paper, a new active phase shifter is proposed using a vector sum method, and it is shown that the proposed phase shifter is more efficient than the others in size, power, number of circuits, and gain. Also a unique digital phase control method of the circuit is suggested. The proposed scheme was designed and implemented using a Wilkinson power combiner/divider, a branch line 3dB quadrature hybrid coupler and variable gain amplifiers (VGAs) using dual gate FETs (DGFETs). Furthermore, it is also shown that the proposed scheme is more efficient and works properly with the digital phase control method.

  • PDF

Fuzzy Controlled ZVS Asymmetrical PWM Full-bridge DC-DC Converter for Constant load High Power Applications

  • Marikkannan., A;Manikandan., B.V
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1235-1244
    • /
    • 2017
  • This paper proposes a fuzzy logic controlled new topology of high voltage gain zero voltage switching (ZVS) asymmetrical PWM full-bridge DC-DC boost converter for constant load and high power applications. The APWM full-bridge stage provides high voltage gain and soft-switching characteristics increase the efficiency and reduce the switching losses. Fuzzy logic controller (FLC) improves the performance and dynamic characteristics of the proposed converter. A comparison with a classical proportional-integral (PI) controller demonstrates the high performances of the proposed technique in terms of effective output voltage regulation under different operating conditions. Simulation is done by integrating two different simulation platforms $PSIM^{(R)}$ and $Matlab^{(R)}/Simulink^{(R)}$ by using SimCoupler tool of $PSIM^{(R)}$. Experimental results using 120W load have been provided to validate the results.

Analysis of Partial Discharge in High Voltage Motor Model Coils (고압전동기 모델 코일의 부분방전 분석)

  • Kim, Hee-Dong;Kong, Tae-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2091-2093
    • /
    • 2005
  • Five model coils of 6.6kV motor were manufactured with several defects. These stator coils have artificial defects such as void of groundwall insulation, removal of semi-conductive coating and damage of strand insulation. Epoxy-mica coupler(80 pF) was connected to five model coil terminals, respectively The voltage applied to the coils was 3.81kV, 4.76kV, 6.0kV and 6.6kV. Partial discharge(PD) tests performed in the laboratory and shield room. Digital PD detector (PDD) and turbine generator analyzer(TGA) were used to measure PD activity. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). The PD levels in pC were measured with PDD. PD patterns of model coils were indicated the internal and slot discharges. PD patterns coincide with both PDD and TGA.

  • PDF

Gate Drive Circuit of a Classic Converter for a Switched Reluctance Motor (Switched Reluctance Motor용 Classic Converter의 Gate 구동회로)

  • Lim, J.Y.;Cho, K.Y;Shin, D.J.;Kim, C.H.;Kim, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.325-327
    • /
    • 1995
  • A new gate drive circuit of classic converter for a switched reluctance motor is presented. Conventional gate drive circuit usually consists of the isolated power supplies and signal transferring devices for isolation, such as photo coupler, pulse transformer, and gate drive chips. The proposed gate drive circuit consists of resistors, capacitors, and zenor diodes without isolated power supplies, that make the drive circuit simple and reduce the material cost. The operational modes are classified and analyzed. The characteristics of the phase current and the gate signal of upper switches is investigated with the variation of duty ratio through the experiments.

  • PDF

Establishment of the Electromagnetic Shielding Effectiveness Measurement System (전자파차폐효과 측정시스템의 구현)

  • 정연춘;강태원;정낙삼
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.4 no.3
    • /
    • pp.45-53
    • /
    • 1993
  • The shielding effectiveness of materials is determined by measuring the ratio of the incident electromagnetic power to that which passes through the material under test. The measurement system is constructed using several test fixtures, tracking generator, spectrum analyzer, step attenuator, RF switches, and amplifiers, etc.. The automation of measurements is completed using a personal computer. Especially, incident power, reflected power, and transmitted power are measured with only one spectrum analyzer using a dual directional coupler and RF switches. Therefore the system is to be used in design of shielding materials, as well as shielding effectiveness measurements. This system has dynamic range of more than 120 dB in the frequency range of 10 MHz to 1 GHz, and it can be used to measure shielding effectiveness of composite materials.

  • PDF