• 제목/요약/키워드: power breakdown

검색결과 918건 처리시간 0.028초

HVDC용 나노복합 절연재료의 DC절연파괴 분석 (Analysis of DC dielectric breakdown strength of Nano-composite insulation material for HVDC Cable)

  • 조성훈;정의환;이한주;임기조;정수현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.104-104
    • /
    • 2010
  • With the advent of nano-particle fillers in insulating materials, the insulating materials of superior quality have come to fore. In the recent past, nanocomposite LDPE/XLPE (Low Density Polyethylene/Cross Linked Polyethylene) power cable dielectrics have been synthesized. A preliminary evaluation of these new class of materials seem to show that, addition of small amounts of sub-micron inorganic fillers improved the dielectric properties of the composite, in particular, the volume resistivity, and the DC breakdown strength. The thermal behaviour, for example, the stability of composites against decomposition and ensuing electrical failure, do not seem to have been addressed. In a conventional XLPE insulated cable, the average thermal breakdown strength and maximum temperature at the onset of breakdown were seen to be markedly lower than the corresponding intrinsic breakdown strength and decomposition temperature. In this page, analysis of DC Breakdown of nano-composite insulating material for HVDC Cable is introduced.

  • PDF

도포된 오일의 변화에 따른 Epoxy/EPDM 계면의 교류 절연 파괴 특성에 관한 연구 (A Study on the AC Interfacial Breakdown Properities of the Interface between Epoxy/EPDM with the variation of spreaded oil)

  • 배덕권;이수길;정일형;이준웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.897-899
    • /
    • 1999
  • In this paper, the interfacial dielectric breakdown phenomenon of interface between Epoxy/EPDM (ethylene propylene diene terpolymer) was discussed, which affects stability of insulation system of power delivery devices. Specimen structure was designed by using MAGSOFT's FLUX2D based on the finite elements method. Design concepts is to reduce the effect of charge transport from electrode in the process of breakdown and to have the tangential electrical potential with the Epoxy/EPDM interface. AC interfacial breakdown phenomenon of was investigated by variation of interfacial conditions oil and temperature which are supposed to have influence on the interfacial breakdown strength. Interfacial breakdown strength was improved by spreading oil over interfacial surface. The decreasing ratio of the AC interfacial breakdown strength in non-oiled specimens was increased by the temperature rising and its of oiled specimens was not affected by temperature.

  • PDF

Effect of Laminated Polypropylene Paper on the Breakdown Strength of Multi-layer Insulation for HTS Cable

  • ;백승명;곽동순;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.87-93
    • /
    • 2004
  • Laminated Polypropylene Paper (LPP) and Kraft paper were used as ac power insulation for conventional cable as well as high temperature superconducting (HTS) cable because of its prominent insulating characteristics. However, researches on the use of LPP/Kraft paper in HTS cables are thinly scattered. In this paper, the effect of laminate polypropylene paper on the breakdown strength of LPP/Kraft multi-layer sample impregnated with liquid nitrogen (LN2)under ac and impulse applied voltage was studied. In addition, the breakdown strength characteristics of LPP and Kraft multi-layer sample were also investigated. It was found from the experimental data that the LPP has higher breakdown strength value than Kraft paper in ac and impulse. Especially in the ac case, the breakdown strength increases as the component ratio of LPP in the LPP/Kraftsample increases and slightly affected by the inserting position of LPP but in impulse case, the breakdown strength strongly depends on the number of LPP and the relative position of LPP.

  • PDF

초고출력 안테나 시스템 급전용 좁은 빔폭의 다중모드 혼 안테나 설계에 관한 연구 (A Study on Design of Narrow Beamwidth Multimode Feed Horn Antenna for High Power Microwave Antenna System)

  • 이상흔;안지환;윤영중;소준호
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.361-366
    • /
    • 2005
  • In this paper, a modified multimode hem antenna is designed to have 142 mm horn aperture radius and 921 mm length in order to be safe under 100 MW peak pulse power at 3 cm wave length through breakdown phenomenon study that threshold field strengths for the air breakdown phenomena is decided to be 3.78 MV/m. The proposed antenna is measured gain over 27 dBi and the -25 dB beam width of 29$^{\circ}$ in vertical plane.

  • PDF

Protection Circuit Module에 최적화된 60 V급 TDMOSFET 최적화 설계에 관한 연구 (Study on Design of 60 V TDMOSFET for Protection Circuit Module)

  • 이현웅;정은식;오름;성만영
    • 한국전기전자재료학회논문지
    • /
    • 제25권5호
    • /
    • pp.340-344
    • /
    • 2012
  • Protected Circuit Module protects battery from over-charge and over-discharge, also prevents accidental explosion. Therefore, power MOSFET is essential to operate as a switch within the module. To reduce power loss of MOSFET, the on state voltage drop should be lowered and the switching time should be shorted. However there is trade-off between the breakdown voltage and the on state voltage drop. The TDMOS can reduce the on state voltage drop. In this paper, effect of design parameter variation on electrical properties of TDMOS, were analyzed by computer simulation. According to the analyzed results, the optimization was performed to get 65% higher breakdown voltage and 17.4% on resistance enhancement.

22.9 kV CV 전력케이블의 14주기 고온 열화에 대한 Lightning-Impulse 특성 (Lightning Impulse Characteristics for 22.9 kV CV Power Cable Before and After Cyclic Aging for 14days)

  • 김위영;윤대혁;박태곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1549-1551
    • /
    • 2001
  • Cyclic aging for 14 days is performed to remove a large amount of the volatiles found in freshly manufactured cable. In this paper, we examined lightning impulse characteristics of 22.9 kV CV power cable before and after cyclic aging for 14days. As the result, the breakdown voltage after aging under normal temperature was lower than that before aging, and the breakdown voltage after aging under hot temperature was lower than that before aging. We found that the dispersion of lightning impulse breakdown voltage before 14 cyclic aging test were reduced rather than those after 14 cyclic aging test.

  • PDF

Fluorocarbon의 전기적 특성연구 (A study on the electrical characteristics of the fluorocarbon)

  • 허창수;조한구
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권2호
    • /
    • pp.217-223
    • /
    • 1995
  • In this paper, we investigated physical properties and electrical characteristics of the fluorocarbon that used as coolants for large power gas-insulated transformer. Volume resistivity of the fluorocarbon was .rho.=1.87*10$^{15}$ [.ohm.cm] at 1 atm, 27.deg. C. Dielectric constant was 1.86 and decreases as temperature increase. The breakdown voltage at 1 atm was higher than that of transformer oil. The breakdown voltage of fluorocarbon vapor was about 18kV when pressure in a test chamber increases over lkg/cm$^{2}$. When fluorocarbon was mixed with SF$_{6}$ gas, breakdown voltage of the mixed was higher than that of fluorocarbon. Then fluorocarbon leads to increase over 4kg/cm$^{2}$ in pressure as temperature increase. Therefore, when a gas-insulated transformer is manufactured, the design must be taken into consideration a high-pressure.

  • PDF

절연재료의 수명예측을 위한 프로그램개발에 관한 연구 (A study on development of program for estimation the Lifetime of insulating materials)

  • 박성민;배덕권;정인재;박우현;이기식;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.699-702
    • /
    • 2000
  • Today, electrical machine is being large capacitor and EHV(Extra High Voltage) of power equipment is a need of high reliability of insulating matetials. Therefore, it is a need of fixed appraisement of lifetime to used data of breakdown. This paper studied a development of the program for estimation the lifetime of insullating materials and the long-time breakdown voltage by experimentation. The estimation program is based on the "Inverse Power Law", defined V$\^$n/t is constant. After gaining the life exponent n, it is mapping the long-time breakdown voltages. On the base of life exponent, the estimation of lifetime and usefulness of the insulation systems are possible, furthermore easy calculation is possible.

  • PDF

내압특성개선을 위한 트렌치 필드링 설계 및 전기적특성에 관한 연구 (A Study on Electrical Characteristics of Trench Field Ring for Breakdown Characteristics)

  • 강이구;김범준;이용훈
    • 한국전기전자재료학회논문지
    • /
    • 제23권1호
    • /
    • pp.1-5
    • /
    • 2010
  • In this paper, we proposed trench field ring for breakdown voltage of power devices. The proposed trench field ring was improved 10% efficiency comparing with conventional field ring. we analyzed five parameters of trench field ring for design of trench field ring and carried out 2-D devices simulation and process simulations. That is, we analyzed number of field ring, juction depth, distance of field rings, trench width, doping profield. The proposed trench field ring was better to more 1000 V.

Analysis of Gate-Oxide Breakdown in CMOS Combinational Logics

  • Kim, Kyung Ki
    • 센서학회지
    • /
    • 제28권1호
    • /
    • pp.17-22
    • /
    • 2019
  • As CMOS technology scales down, reliability is becoming an important concern for VLSI designers. This paper analyzes gate-oxide breakdowns (i.e., the time-dependent dielectric-breakdown (TDDB) aging effect) as a reliability issue for combinational circuits with 45-nm technology. This paper shows simulation results for the noise margin, delay, and power using a single inverter-chain circuit, as well as the International Symposium on Circuits and Systems (ISCAS)'85 benchmark circuits. The delay and power variations in the presence of TDDB are also discussed in the paper. Finally, we propose a novel method to compensate for the logic failure due to dielectric breakdowns: We used a higher supply voltage and a negative ground voltage for the circuit. The proposed method was verified using the ISCAS'85 benchmark circuits.