• Title/Summary/Keyword: power balance control

Search Result 325, Processing Time 0.024 seconds

DC-Link Voltage Balance Control in Three-phase Four-wire Active Power Filters

  • Wang, Yu;Guan, Yuanpeng;Xie, Yunxiang;Liu, Xiang
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1928-1938
    • /
    • 2016
  • The three-phase four-wire shunt active power filter (APF) is an effective method to solve the harmonic problem in three-phase four-wire power systems. In addition, it has two possible topologies, a four-leg inverter and a three-leg inverter with a split-capacitor. There are some studies investigating DC-link voltage control in three-phase four-wire APFs. However, when compared to the four-leg inverter topology, maintaining the balance between the DC-link upper and lower capacitor voltages becomes a unique problem in the three-leg inverter with a split-capacitor topology, and previous studies seldom pay attention to this fact. In this paper, the influence of the balance between the two DC-link voltages on the compensation performance, and the influence of the voltage balance controller on the compensation performance, are analyzed. To achieve the balance between the two DC-link capacitor voltages, and to avoid the adverse effect the voltage balance controller has on the APF compensation performance, a new DC-link voltage balance control strategy for the three-phase four-wire split-capacitor APF is proposed. Representative simulation and experimental results are presented to verify the analysis and the proposed DC-link voltage balance control strategy.

A Study on Power Balance Control for Hybrid Power System with Common DC Link (공통 DC단을 갖는 복합발전시스템을 위한 전력균형제어에 관한 연구)

  • Jeong B. H.;Cho J. S.;Gho J. S.;Choe G. H.;Kim E. S.;Lee C. S.
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.181-185
    • /
    • 2002
  • This paper discusses power balance control of photovoltaic/wind/diesel hybrid generation system for remote area power supplies. There are many control methods for hybrid power system. Among others, it must be adopted that the control method to guarantee a stable balance between supply and demand, regardless of the fluctuation of generator power by atmospheric changes. In this paper, it Is proposed that a hybrid generation system has a power-balanced controller to equilibrate generation power with a load demand, which is composed of DC bus-type power systems. To execute power balance control, it is assumed that all of power generators have a equivalent current-source characteristics. Through the results of simulation, the proposed scheme was verified.

  • PDF

Digital Control of an AC/DC Converter using the Power Balance Control Technique with Average Output Voltage Measurement

  • Wisutmetheekorn, Pisit;Chunkag, Viboon
    • Journal of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.88-97
    • /
    • 2012
  • This paper presents a method for the digital control of a high power factor AC/DC converter employing the power balance control technique to achieve a fast response of the output voltage control. To avoid the effects of an output voltage ripple in the voltage control loop, the average output voltage is sampled and used as a feedback signal for the output voltage controller. The proposed control technique was verified by simulations using MATLAB/Simulink and its implementation was realized by a dsPIC30F4011 digital signal processor to control a CUK topology AC/DC converter with a 48V output voltage and a 250 W output power. The experimental results agree with the simulation results. The proposed control technique achieves a fast transient response with a lower line current distortion than is achieved when using a conventional proportional-integral controller and the power balance control technique with the conventional sampling method.

Reactivity balance for a soluble boron-free small modular reactor

  • van der Merwe, Lezani;Hah, Chang Joo
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.648-653
    • /
    • 2018
  • Elimination of soluble boron from reactor design eliminates boron-induced reactivity accidents and leads to a more negative moderator temperature coefficient. However, a large negative moderator temperature coefficient can lead to large reactivity feedback that could allow the reactor to return to power when it cools down from hot full power to cold zero power. In soluble boron-free small modular reactor (SMR) design, only control rods are available to control such rapid core transient. The purpose of this study is to investigate whether an SMR would have enough control rod worth to compensate for large reactivity feedback. The investigation begins with classification of reactivity and completes an analysis of the reactivity balance in each reactor state for the SMR model. The control rod worth requirement obtained from the reactivity balance is a minimum control rod worth to maintain the reactor critical during the whole cycle. The minimum available rod worth must be larger than the control rod worth requirement to manipulate the reactor safely in each reactor state. It is found that the SMR does have enough control rod worth available during rapid transient to maintain the SMR at subcritical below k-effectives of 0.99 for both hot zero power and cold zero power.

Charge Balance Control Methods for a Class of Fundamental Frequency Modulated Asymmetric Cascaded Multilevel Inverters

  • Babaei, Ebrahim
    • Journal of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.811-818
    • /
    • 2011
  • Modulation strategies for multilevel inverters have typically focused on synthesizing a desired set of sinusoidal voltage waveforms using a fixed number of dc voltage sources. This makes the average power drawn from different dc voltage sources unequal and time varying. Therefore, the dc voltage sources are unregulated and require that corrective control action be incorporated. In this paper, first two new selections are proposed for determining the dc voltage sources values for asymmetric cascaded multilevel inverters. Then two modulation strategies are proposed for the dc power balancing of these types of multilevel inverters. Using the charge balance control methods, the power drawn from all of the dc sources are balanced except for the dc source used in the first H-bridge. The proposed control methods are validated by simulation and experimental results on a single-phase 21-level inverter.

A Development of 3 Phase Current Balance Control Algorithm (3상 전류평형 제어기술 알고리즘 개발)

  • Cheon, Y.S.;Seong, H.S.;Won, H.J.;Han, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1091-1093
    • /
    • 2001
  • The power semiconductor is widely used in the power plant or industrial field because of genealization and enlargement. It has been controlled and operated according to its own control method. Especially in case of Power plant, it plays a major role in AVR(Automatic Voltage Regulator) or electro chlorination control circuits. Generally, they used in Analog control system at above field. But each SCR current value is different because of load unbalance or switching characteristic variations, it may cause power plant unit trip or system disorder according to SCR element burn out or bad operating condition. Therefore, in this paper a development of 3 phase current balance control algorithm is described. it gets over the past analog control system limit, controls SCR gate firing angle for 3 phase current balance.

  • PDF

A Development of 3 Phase Current Balance Control Unit (3상 전류평형 제어기술 적용장치 개발)

  • Cheon, Y.S.;Seong, H.S.;Won, H.J.;Han, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1088-1090
    • /
    • 2001
  • In general, Power SCR(Silicon Controlled Rectifier) is most widely used in Power Plant as well as Industrial field. It has been controlled and operated according to its own control method. Especially, in case of Power plant, it plays a major role in AVR(Automatic Voltage Regulator) or electro chlorination control circuits. Generally, they used in Analog control system at above field. But each SCR current value is different because of load unbalance or switching characteristic variations, it may cause power plant unit trip or system disorder according to SCR element burn out or bad operating condition. Therefore, in this paper a development of 3 phase current balance control unit is described, it gets over the past analog control system limit, uses DSP(Digital signal processor) had high speed response, controls SCR gate firing angle for 3 phase current balance.

  • PDF

Effects of Short-Term Intensive Balance Training for the Performance Ability of Lower Extremities in the Elderly (노인의 단기집중 균형훈련이 하지수행능력에 미치는 영향)

  • Jung, Soon-Mi;An, Duk-Hyun
    • Physical Therapy Korea
    • /
    • v.14 no.1
    • /
    • pp.11-20
    • /
    • 2007
  • The objective of this study was to discern the effects of a balance training program on the performance of lower extremities in order to improve strength (muscle power, flexibility, walking power), balance control and walking ability in the elderly. The subjects selected were aged 65 years and over, with no known relevant medical history that may disturb their balance, and have also been visiting the Gimhae Senior Welfare Center. The variable group consisted of 30 subjects, of whom were people who had been participating in balance training programs (One Leg Standing; OLS, Functional Reach; FR, Timed Get Up and Go; TUG) as an intervention for 8 weeks 3 times per a week. They were examined in order to identify their balance control before and after. The control group consisted of thirty subjects who preferred to exercise without any intervention relating to balance training program. The subjects were measured before and after balance training in order to determine the effectiveness of exercise and the effectiveness of exercise combined with the aid of a Balance Performance Monitor. 1. Mean time on OLS test with left and right sided extremities in the experimental group was 35.44 sec, 42.10 sec longer than control group respectively. In FR tests applied to the left and right side, mean reaching distance was increased up to 5.56 cm, 6.73 cm in experimental group respectively. Mean time on TUG test from a chair in experimental group was decreased to 2.33 sec. 2. Mean value of decline in the level balance control, both left and right side, decreased to 2.24% as examined by the Balance Performance Monitor. Mean scores for sway level after balance training decrease to .98% and for balance control both anterior and posterior directions decreased to mean 1.07% and 1.44%, respectively.

  • PDF

A Study on Photovoltaic/Wind/Diesel Hybrid Power System

  • Jeong, Byung-Hwan;Cho, Jun-Seok;Gho, Jae-Seok;Choe, Gyu-Ha;Kim, Eung-Sang;Lee, Chang-Sung
    • Journal of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.40-48
    • /
    • 2003
  • In this paper, a hybrid power system with photovoltaic/wind/diesel generators is proposed to solve the defect of stand-alone type power system in a remote area. A hybrid power system has a power-balanced controller to equilibrate generation power with a given load demand and which is composed of common DC power system. To execute a power-balanced control, a hybrid power system is assumed that all of power generators have the characteristics of an equivalent current-source and load sharing control technique must be needed at the same time. So this paper discusses the structure of power-balance control for hybrid power system. And through the results of simulation, the proposed scheme was verified.

Modeling, Analysis, and Enhanced Control of Modular Multilevel Converters with Asymmetric Arm Impedance for HVDC Applications

  • Dong, Peng;Lyu, Jing;Cai, Xu
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1683-1696
    • /
    • 2018
  • Under the conventional control strategy, the asymmetry of arm impedances may result in the poor operating performance of modular multilevel converters (MMCs). For example, fundamental frequency oscillation and double frequency components may occur in the dc and ac sides, respectively; and submodule (SM) capacitor voltages among the arms may not be balanced. This study presents an enhanced control strategy to deal with these problems. A mathematical model of an MMC with asymmetric arm impedance is first established. The causes for the above phenomena are analyzed on the basis of the model. Subsequently, an enhanced current control with five integrated proportional integral resonant regulators is designed to protect the ac and dc terminal behavior of converters from asymmetric arm impedances. Furthermore, an enhanced capacitor voltage control is designed to balance the capacitor voltage among the arms with high efficiency and to decouple the ac side control, dc side control, and capacitor voltage balance control among the arms. The accuracy of the theoretical analysis and the effectiveness of the proposed enhanced control strategy are verified through simulation and experimental results.