• 제목/요약/키워드: power and energy consumption

검색결과 2,014건 처리시간 0.026초

중앙 냉방시스템의 전력량 요금절감을 위한 디맨드제어 적용방안 연구 (Demand Control Application Strategies for Saving Electric Power Price of Central Cooling System)

  • 황진원;송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권4호
    • /
    • pp.1-7
    • /
    • 2012
  • In this study, computer simulation for demand control strategies to save the electric energy and power price in the building central cooling system is done. The demand control and outdoor reset control algorithms are applied by consideration the electric energy and power price according to the energy consumption characteristics. The suggested control methods show better responses in the power price and energy consumption in comparison with the conventional one.

반도체 공정장비 Gas Scrubber의 에너지 모니터링 시스템개발 (Development of an Energy MonItorIng System for Gas Scrubber)

  • 김선만;임익태;안강호
    • 반도체디스플레이기술학회지
    • /
    • 제10권2호
    • /
    • pp.13-17
    • /
    • 2011
  • We have developed a new energy-consuming monitoring system that has made it possible to measure the energy consumption of a gas scrubber, one of semiconductor processing equipments, and installed this system to the gas scrubber under operating at a manufacture site. Using this system, we have measured consumptions of electric power and processing gas consumed at standby to operating mode. In case of the gas scrubber, processing gas flows continuously into it at standby and operating mode. Therefore, if the electric power has been supplied, the processing gas can flows into the device for 24 hours. Moreover, at operating of gas scrubber, the amount of electricity consumption is 5 kWh. At Standby of gas scrubber, it spends 3kwh. It is certain that the energy consumption is greater at operating mode than at standby mode. The carbon emission rates from 24 hour gas scrubber operation are 236 $kgCO_2$/day of $N_2$, 57 $kgCO_2$/day of electric power and 0.001 $kgCO_2$/day of cooling water. Most of carbon is emitted from $N_2$ gas and electric power consumption.

화력발전소 보일러 연료소비량 계산 및 정확성 검증 (Fuel Consumption Rate Calculation Equation and its Application at fewer Boiler)

  • 장석원;김재훈
    • 에너지공학
    • /
    • 제14권2호
    • /
    • pp.147-152
    • /
    • 2005
  • 본 논문에서는 화력발전소 보일러 연료소비량을 측정에 의하지 않고 계산으로 구하는 방법을 세부 항목 별로 유도하고 그 결과를 검증하였다. 보일러 경계를 출입하는 Energy in Energy out의 정량적 관계를 분석하여 Energy in에 해당하는 투입열량과 Energy out에 해당하는 흡수열량 및 손실열량으로부터 에너지 출입의 유기적인 관계식을 수립하여 연료소비량 계산식을 유도, 정립하고 실제 운전중인 석탄 및 중 유연소 발전소에 적응하여 계산식의 정확성을 검증하였다.

Energy Efficiency of Distributed Massive MIMO Systems

  • He, Chunlong;Yin, Jiajia;He, Yejun;Huang, Min;Zhao, Bo
    • Journal of Communications and Networks
    • /
    • 제18권4호
    • /
    • pp.649-657
    • /
    • 2016
  • In this paper, we investigate energy efficiency (EE) of the traditional co-located and the distributed massive multiple-input multiple-output (MIMO) systems. First, we derive an approximate EE expression for both the idealistic and the realistic power consumption models. Then an optimal energy-efficient remote access unit (RAU) selection algorithm based on the distance between the mobile stations (MSs) and the RAUs are developed to maximize the EE for the downlink distributed massive MIMO systems under the realistic power consumption model. Numerical results show that the EE of the distributed massive MIMO systems is larger than the co-located massive MIMO systems under both the idealistic and realistic power consumption models, and the optimal EE can be obtained by the developed energy-efficient RAU selection algorithm.

Building Smart Microgrid Test-Bed를 이용한 전력사용량 패턴 최적화방안 연구 (A Study on the Optimization of Power Consumption Pattern using Building Smart Microgrid Test-Bed)

  • 이상우;강진규;이동하
    • 한국태양에너지학회 논문집
    • /
    • 제34권4호
    • /
    • pp.1-7
    • /
    • 2014
  • The microgrid system is the combination of photovoltaic(PV) array, load, and battery energy storage system. The control strategies were defined as multi-modes of operation, including rest operation without use of battery, power charging, and power discharging, which enables grid connected mode or islanded mode. Photovoltaic power is a problem of the uniformity of power quality because the power generated from solar light is very sensitive to variation of insolation and duration of sunshine. As a solution to the above problem, energy storage system(ESS) is considered generally. There fore, in this study, we did basic research activities about optimization method of the amount of energy used, using a smart microgrid test-bed constructed in building. First, we analyzed the daily, monthly and period energy pattern amount of power energy used, and analyzed PV power generation level which is built on the roof. Utilizing building energy pattern analysis data, we was studied an efficient method of employing the ESS about building power consumption pattern and PV generation.

회생에너지를 이용한 도시철도 전력관리시스템 구축에 관한 연구 (Study for Power Management System using Regenerative Energy in Electric Railway Systems)

  • 이한상;조윤성;김형철;정호성
    • 전기학회논문지
    • /
    • 제63권1호
    • /
    • pp.191-196
    • /
    • 2014
  • For the large scale of electricity consumer, since the price for the electricity consumption depends on the peak power, the issue for peak power reduction have been being studied widely. Electric railway systems, which is one of the most representative large scale of loads, also has assignment to reduce the peak power since they have high peak power and low energy consumption load characteristics. In the aspect of the economic operation through reduction of peak power, this paper proposes a novel algorithm for power management system in electric railway systems using energy storage.

마이크로터빈이 포함된 빌딩마이크로그리드시스템의 병원건물의 에너지성능평가 (Energy Performance Evaluation of Building Micro-grid System Including Micro-turbine in Hospital Buildings)

  • 김병수;홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.279-283
    • /
    • 2009
  • Distributed generation(DG) of combined cooling, heat. and power(CCHP)has been gaining momentum in recent year as efficient, secure alternative for meeting increasing energy demands. This paper presents the energy performance of microturbine CCHP system equipped with an absorption chiller by modelling it in hospital building. The orders of study were as following. 1)The list and schedule of energy consumption equipment in hospital were examined such as heating and cooling machine, light etc. 2) Annual report of energy usage and monitoring data were examined as heating, cooling, DHW, lighting, etc. 3) The weather data in 2007 was used for simulation and was arranged by meteorological office data in Daejeon. 4) Reference simulation model was built by comparison of real energy consumption and simulation result by TRNSYS and ESP-r. The energy consumption pattern of building were analyzed by simulation model and energy reduction rate were calculated over the cogeneration. As a result of this study, power generation efficiency of turbine was about 30% after installing micro gas turbine and lighting energy as well as total electricity consumption can be reduced by 40%. If electricity energy and waste heat in turbine are used, 56% of heating energy and 67% of cooling energy can be reduced respectively, and total system efficiency can be increased up to 70%.

  • PDF

고성능 저전력 하이브리드 L2 캐시 메모리를 위한 연관사상 집합 관리 (Way-set Associative Management for Low Power Hybrid L2 Cache Memory)

  • 정보성;이정훈
    • 대한임베디드공학회논문지
    • /
    • 제13권3호
    • /
    • pp.125-131
    • /
    • 2018
  • STT-RAM is attracting as a next generation Non-volatile memory for replacing cache memory with low leakage energy, high integration and memory access performance similar to SRAM. However, there is problem of write operations as the other Non_volatile memory. Hybrid cache memory using SRAM and STT-RAM is attracting attention as a cache memory structure with lowe power consumption. Despite this, reducing the leakage energy consumption by the STT-RAM is still lacking access to the Dynamic energy. In this paper, we proposed as energy management method such as a way-selection approach for hybrid L2 cache fo SRAM and STT-RAM and memory selection method of write/read operation. According to the simulation results, the proposed hybrid cache memory reduced the average energy consumption by 40% on SPEC CPU 2006, compared with SRAM cache memory.

전송전력 최적화를 통한 센서네트워크의 효율적인 에너지관리에 대한 연구 (Study of Efficient Energy Management for Ubiquitous Sensor Networks with Optimization of the RF power)

  • 엄흥식;김건욱
    • 전자공학회논문지CI
    • /
    • 제44권3호
    • /
    • pp.37-42
    • /
    • 2007
  • 본 논문에서는 무선채널의 신호감쇄특성으로 인하여 멀티홉을 통한 센서네트워크의 에너지소비를 최소화하려는 기존의 연구를 재해석하고 무선채널의 특성과 하드웨어의 전력소비를 동시에 고려하여 센서네트워크의 에너지소비를 모델링하였다. 또한 센서네트워크 하드웨어 플랫폼에 주로 사용되고 있는 RF모듈인 Chipcon사의 CC2420을 대상으로 최대 전송전력과 최소의 홉을 통한 데이터 전송이 네트워크의 에너지효율에 미치는 영향을 다양한 상황의 시뮬레이션을 통해 검증한다. 최대 전송전력으로 최소의 홉을 통하여 전송했을 경우, 낮은 전송전력으로 여러 홉을 거쳐 데이터를 전송하는 것보다 네트워크의 에너지소비가 적게 발생하는 것으로 관찰된다. 높은 전송전력에 따라 증가하는 재전송을 고려한 결과 또한 최대 전송전력으로 전송했을 경우 최대 33.1%의 에너지효율을 얻을 수 있다.

공동주택 에너지 사용량 평가 개선을 위한 에너지 사용량 영향 요인 도출 (Deriving Factors Affecting Energy Usage for Improving Apartment Energy Consumption Evaluation)

  • 음미령;홍원화;이지애
    • 대한건축학회논문집:구조계
    • /
    • 제34권7호
    • /
    • pp.27-34
    • /
    • 2018
  • The energy consumption of apartment houses is affected by various factors. The criteria for assessing current energy usage are area, region and purpose. The purpose of this study is to obtain the reliability of the method of evaluating the existing energy consumption certificate and to derive usable evaluation factors according to the correlation of factors affecting energy consumption. The research process collects energy usage data for apartment houses in Daegu and calculates statistical results through correlation analysis and multiple regression analysis. As a result, it was found that the power energy is influenced by the yearly factor of physical characteristics, and the heat energy and total energy usage are influenced by the energy source which is energy characteristic factor.