Characterization of Anodized Al 1050 with Electrochemically Deposited Cu, Ni and Cu/Ni and Their Behavior in a Model Corrosive Medium

  • Girginov, Christian;Kozhukharov, Stephan;Tsanev, Alexander;Dishliev, Angel
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.188-203
    • /
    • 2021
  • The specific benefits of the modified films formed on preliminary anodized aluminum, including the versatility of their potential applications impose the need for evaluation of the exploitation reliability of these films. In this aspect, the durability of Cu and Ni modified anodized aluminum oxide (AAO) films on the low-doped AA1050 alloy was assessed through extended exposure to a 3.5% NaCl model corrosive medium. The electrochemical measurements by means of electrochemical impedance spectroscopy (EIS) and potentiodynamic scanning (PDS) after 24 and 720 hours of exposure have revealed that the obtained films do not change their obvious barrier properties. In addition, supplemental analyses of the coatings were performed, in order to elucidate the impact of the AC-deposition of Cu and Ni inside the pores. The scanning electron microscopy (SEM) images have shown that the surface topology is not affected and resembles the typical surface of an etched metal. The subsequent energy dispersive X-ray spectroscopy (EDX) tests have revealed a predominance of Cu in the combined AAO-Cu/Ni layers, whereas additional X-ray photoelectron (XPS) analyses showed that both metals form oxides with different oxidation states due to alterations in the deposition conditions, promoted by the application of AC-polarization of the samples.

Corrosion Inhibition of Carbon Steel in Sulfuric Acid Using Cymbopogon citratus as a Green Corrosion Inhibitor

  • Gadang, Priyotomo;Tamara Emylia Suci, Nurarista;Yanyan, Dwiyanti;Bening Nurul Hidayah, Kambuna;Arini, Nikitasari;Siska, Prifiharni;Sundjono, Sundjono
    • Corrosion Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.423-433
    • /
    • 2022
  • The objective of this study was to determine whether Cymbopogon citratus extract as a corrosion inhibitor from natural tropical resources could prevent corrosion of carbon steel in sulfuric acid solution. Inhibitory action of this extract was investigated using electrochemical methods such as potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). Those methods revealed corrosion rate, efficiency of inhibition, and adsorptions isotherm values when the extract was added to the sulfuric acid solution at concentration up to 500 ppm with various immersion time at ambient temperature. Results revealed that higher concentration of the extract and longer immersion time decreased the corrosion rate of carbon steel whereas the inhibition efficiency of the extract was increased up to 97.25%. The value of charge transfer resistance was increased significantly by adding the extract at concentration up to 500 ppm with an immersion time of 60 minutes. The type of the extract was a mixed inhibitor. It could inhibit the corrosion process in both anodic and cathodic sides electrochemically. Results of this study suggest that the mechanism of adsorption on the surface of carbon steel is related to Langmuir adsorption isotherm.

Effects of pH and Chloride Concentration on Corrosion Behavior of Duplex Stainless Steel and Titanium Alloys Ti 6Al 2Nb 1Ta 1Mo at Elevated Temperature for Pump Impeller Applications

  • Aymen A., Ahmed;Ammar Yaseen, Burjes;Ammar Yaseen, Burjes
    • Corrosion Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.454-465
    • /
    • 2022
  • The objective of this study was to determine effects of temperatures and pH of sodium chloride solution with MgCl2 ions on corrosion resistance of duplex stainless-steel X2CrNiMoN22-5-3 (DSS) and Ti 6Al 2Nb1Ta1Mo (Ti). Effects of sodium chloride concentration on corrosion resistance were also studied. Corrosion behavior and pitting morphology of duplex stainless steel (DSS) and Ti alloys were evaluated through potentiodynamic polarization, electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM). It was found that a decrease in pH significantly reduced the corrosion resistance of both alloys. Changes in chloride concentration and temperature had more substantial impact on corrosion behavior of DSS than on Ti alloys. Pitting corrosion was formed on DSS samples under all conditions, whereas crevice corrosion was developed on Ti samples with the presence of magnesium chloride at 90 ℃. In conclusion, magnesium chloride ions in an exceedingly strong acidity solution appear to interact with re-passivation process at the surface of these alloys and influence the resulting surface topography.

The Synergistic Effect of 2-Chloromethylbenzimidazole and Potassium Iodide on the Corrosion behavior of Mild Steel in Hydrochloric Acid Solution

  • Zhou, Liben;Cheng, Weizhong;Wang, Deng;Li, Zhaolei;Zhou, Haijun;Guo, Weijie
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.138-147
    • /
    • 2022
  • The synergistic effect of 2-chloromethylbenzimidazole (2-CBI) and potassium iodide (KI) for mild steel in 1 M hydrochloric acid solution was investigated by potentiodynamic polarization curves and electrochemical impedance spectroscopy (EIS). The results showed that, with the addition of 100 ppm potassium iodide, the inhibition efficiecy (IE) of 100 ppm 2-CBI in 1 M hydrochloric acid had been improved from 91.14% to 96.15%. And synergistic parameter of 100 ppm 2-CBI with different amounts of potassium iodide is always greater than 1. The adsorption of potassium iodide combining with 100 ppm 2-CBI obeys to the Langmuir adsorption isotherm. Thermodynamic adsorption parameters, including ∆G0ads, ∆Ha and ∆Sa of the adsorption of the combinned inhibitor, as well as the Ea of the mild steel corrosion in 1 M HCl with the combinned inhibitor, were calculated.

Influence of Inhibitors on the Corrosion of Al and Al-composites in Chloride-containing Solutions - A Review

  • Kumar, Neeraj;Srivastava, Ashok K.;Gautam, Prabhat;Manoj, M.K.
    • Korean Journal of Materials Research
    • /
    • v.32 no.5
    • /
    • pp.280-286
    • /
    • 2022
  • Corrosion is a natural, inevitable process, and is one of the world's most serious problems. Losses incurred due to corrosion are extremely expensive for society. Several technological strategies have been explored and implemented to address these losses. The use of inhibitors to prevent corrosion is a common and efficient method to reduce corrosion losses. This review covers Al and Al-composite corrosion inhibitors in chloride-containing solutions, because of their popularity in a broad array of industrial applications. A vast number of studies in the literature detail the common tendency of Al and Al-composites with reinforcements to deteriorate. Accordingly, it is worthwhile to employ inhibitors to protect them, as discussed in the present work. The emphasis is on selecting the smartest corrosion inhibitor and evaluating its performance. According to the study, the most commonly used corrosion inhibitors are 1,4-naphthoquinone (NQ), 1,5-naphthalene diol, 3-amino-1,2,4-triazole-5-thiol (ATAT), ammonium tetrathiotungstate, clotrimazole, amoxicillin, antimicrobial and antifungal drugs. Electrochemical impedance spectroscopy (EIS), potentiodynamic (PDP), and weight loss were among the most commonly used modern electrochemical technologies to test inhibitors' efficacy under environmental conditions.

Tribological and Corrosion Behavior of Multilayered $WC-Ti_{1-x}Al_xN$ Coatings Deposited by Cathodic Arc Deposition Process on High Speed Steel

  • S.H. Ahn;J.H. Yoo;Park, Y.S.;Kim, J.G.;Lee, H.Y.;J.G. Han
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.31-32
    • /
    • 2001
  • Recently, many of the current development in surface modification engineering are focused on multilayered coatings. Multilayered coatings have the potential to improve the tribological and corrosion properties of tools and components. By using cathodic arc deposition, $WC-Ti_{1-x}Al_xN$ multilayers were deposited on steel substrates. Wear tests of four multiplayer coatings were performed using a ball-on-disc configuration with a linear sliding speed of 0.1m/s, 5N load. The tests were carried out at room temperature in airby employing AISI 52100 steel ball ($H_v=848N$) of 11mm in diameter. Electrochemical tests were performed using the potentiodynamic and electrochemical impedance spectroscopy (EIS) measurements. The surface morphology and topography of the wear scars of tribo-element and the corroded specimen have been determined by using scanning electron spectroscopy (SEM). Also, wear mechanism was determined by using SEM coupled with EDS. Results have showed an improved wear resistance and corrosion resistance of the $WC-Ti_{1-x}Al_xN$ coatings.

  • PDF

Insights into the corrosion inhibition of steel rebar in chloride-contaminated synthetic concrete pore solutions by a new hydrazone (새로운 히드라존에 의한 염화물 오염 합성 콘크리트 공극 솔루션에서 철근의 부식 억제에 대한 통찰력)

  • Lgaz, Hassane;Lee, Han-seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.101-102
    • /
    • 2022
  • A new hydrazone derivatives namely (E)-N'-(4-(dimethylamino)benzylidene)-2-(5-methoxy-2-methyl-1H-indol-3-yl)acetohydrazide (HIND) has been confirmed for mitigating the corrosion of the steel rebar exposed to chloride contaminated synthetic concrete pore solution (ClSCPS). The mitigation of corrosion properties has been characterized by weight loss and electrochemical methods (Electrochemical impedance, Potentiodynamic polarization studies) as well as surface observations. The presence of HIND in the ClSCPS decreased the corrosion of steel rebar by adsorption of HIND molecules on the surface of the steel rebar. The optimal HIND concentration was 0.5 mmol/L, corresponding to an inhibition efficiency of 88.4%. The use of HIND enables the corrosion process to have a higher energy barrier. X-ray photo electron spectroscopy (XPS), atomic force microscopy (AFM), scanning electron microscopy-energy-dispersive spectroscopy (SEM-EDS), and X-ray diffraction (XRD) spectroscopy interpretations confirmed that HIND mitigates the corrosion attack on the surface steel rebar.

  • PDF

Investigation of the Electrochemical Characteristics of Electropolished Super Austenite Stainless Steel with Seawater Temperature (전해연마한 슈퍼오스테나이트 스테인리스강의 해수온도에 따른 전기화학적 특성 연구)

  • Hyun-Kyu Hwang;Seong-Jong Kim
    • Corrosion Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.164-174
    • /
    • 2023
  • Electropolishing technology uses an electrochemical reaction and improves surface roughness, glossiness, and corrosion resistance. In this investigation, electropolishing was performed to improve the corrosion resistance of super austenitic stainless steel. As a result of electropolishing, surface roughness (0.16 ㎛) was improved by about 76.5% compared to mechanical polishing (0.68 ㎛). In addition, the electropolished surface was smooth because the average and variance values of the depth histogram were small. Tafel analysis was performed after a potentiodynamic polarization experiment with seawater temperature, and the microstructure was compared and analyzed. The corrosion current density at 30 ℃, 60 ℃, and 90 ℃ was reduced by 0.083 ㎂/cm2, 0.296 ㎂/cm2, and 0.341 ㎂/cm2, respectively. Pitting occurred in the mechanical polished specimen at 30 ℃, but partial intergranular corrosion was observed in the electropolished specimen, and pitting occurred predominantly at both 60 ℃ and 90 ℃. In addition, the damage depths of the electropolished specimen were shallower than those of mechanical polishing at 30 ℃ and 60 ℃, but the opposite result was seen at 90 ℃.

Corrosion Inhibition Properties of New Thiazolidinedione Derivatives for Copper in 3.5 wt.% NaCl Medium (3.5 중량% NaCl 매질에서 구리에 대한 새로운 티아졸리딘디온 유도체의 부식 억제 특성)

  • Lgaz, Hassane;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.27-28
    • /
    • 2021
  • The search for new corrosion inhibitors for different corrosive mediums is a never-ending task. In the present work, the corrosion inhibition behavior and adsorption mechanism of two novel synthetic thiazolidinedione derivatives noted MTZD and ATZD in 3.5 wt.% NaCl solution on copper were investigated. Electrochemical, scanning electron microscope (SEM), atomic force microscopy (AFM) techniques were used along with first-principles DFT calculations. At maximum inhibitor concentration i.e., 300 ppm corrosion inhibition efficiency reached maximum up to 90% and 96% for MTZD and ATZD, respectively, and thereby followed the order of ATZD > MTZD. The inhibition efficiency increased up to 24 h of immersion, and then decreased after 48h immersion. The potentiodynamic curves suggested that the inhibition action of tested compounds is a mixed type of inhibitor. The first-principles DFT calculations suggested that compounds under investigation formed covalent bonds with Cu(111) surface via reactive sites. SEM and AFM results confirmed the formation of protective barrier that prevent corrosion attack.

  • PDF

Surface Hardness and Corrosion Behavior of AISI 420 Martensitic Stainless Steels Treated by Plasma Oxy-Nitriding Processing (플라즈마 산질화처리된 AISI 420 마르텐사이트 스테인레스 강재의 표면 경도 및 부식 거동)

  • Jinhan Kim;Kwangmin Lee
    • Korean Journal of Materials Research
    • /
    • v.33 no.7
    • /
    • pp.309-314
    • /
    • 2023
  • This study aimed to address the limitations of traditional plasma nitriding methods by implementing a short-term plasma oxy-nitriding treatment on the surface of AISI 420 martensitic stainless steel. This treatment involved the sequential formation of nitride and oxide layers, to enhance surface hardness and corrosion resistance, respectively. The process resulted in the formation of a 20 ㎛-thick nitride layer and a 3 ㎛-thick oxide layer on the steel surface. Initially, the hardness increased by 2.2 times after nitriding, followed by a subsequent decrease of approximately 31 % after oxidation. While the nitriding process reduced corrosion resistance, the subsequent oxidation process led to the formation of a passive oxide film, effectively resolving this issue. The pitting corrosion of the oxide passive film started at 82.6 mVssc, providing better corrosion resistance characteristics than the nitride layer. Consequently, the trade-off between surface hardness and corrosion resistance in plasma oxy-nitrided AISI 420 martensitic stainless steel is anticipated to be recognized as an innovative and comprehensive surface treatment process for biomedical components.