• 제목/요약/키워드: post-tension

검색결과 288건 처리시간 0.029초

특별직교이방성 이론에 의한 포스트 텐션된 교량의 해석(I) - 철근 콘크리트 슬래브교 - (Analysis of Post-tensioned Bridge by Specially Orthotropic Laminate Theory (I) - Reinforced Concrete Slab Bridge)

  • 김덕현;원치문;이정호
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.135-140
    • /
    • 2001
  • A post-tensioned reinforced concrete slab bridge is analyzed by specially orthotropic laminate theory. Symmetrically reinforced slab with tension and compression steel is considered for convenience of analysis. Each longitudinal and transverse steel layer is regarded as a lamina, and material constants of each lamina is calculated by the use of the rule of mixture. This bridge is under uniformly distributed vertical loads, and axial loads and end moments due to post-tensioning. In this paper, finite difference method is used for numerical analysis of this bridge. Theory and analysis method of specially orthotropic laminate plates used in this paper can be used for design of new bridges, and maintenance and repair of old bridges.

  • PDF

특별직교이방성 이론에 의한 포스트 텐션된 교량의 해석(II) - 강 판형교 - (Analysis of Post-tensioned Bridge by Specially Orthotropic Laminate Theory (II) - Steel Plate Girder Bridge)

  • 김덕현;원치문;이정호
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2001년도 춘계학술발표대회 논문집
    • /
    • pp.141-146
    • /
    • 2001
  • A post-tensioned steel plate girder bridge with cross-beams is analyzed by specially orthotropic laminate theory. The cross-sections of both girders and cross-beams are WF types. The result is compared with that of the beam theory. This bridge with simple support is under uniformly distributed vertical load, and axial loads and moment due to post-tension. In this paper, finite difference method for numerical analysis of simple supported bridge is developed. Relatively exact solution is obtained even with small number of meshes. Theory and analysis method of specially orthotropic laminate plates used in this paper can be used in design of new bridges, and maintenance and repair of old bridges.

  • PDF

포스트텐션에 의한 격자 돔형 공간 구조의 거동 특성 (Behaviour Characteristic of Grid Dome Shaped Space Structures by Post-tensioning)

  • 김진우
    • 한국해양공학회지
    • /
    • 제16권1호
    • /
    • pp.41-45
    • /
    • 2002
  • This paper is concerned with the erection and ultimate load test of dome shaped space structures by post-tensioning. It is a fast and economical method for constructing such a dome by post-tensioning of the cable in bottom chords. This structure consists of uniform pyramids in a flat layouts on the ground, and then the structure is shaped and erected into its final curved space structure. Ultimate load test was performed for dome shaped space structures. The feasibility of the proposed erection method and the reliability of the established geometric model were confirmed with numerical analysis and experimental investigation on a small scale steel model. As a results we can find the most reasonable modeling technique for the prediction of shape formation in practices and we can know the characteristic of the behaviour in ultimate load test for practical design purposes.

포스트 텐션 플랫 플레이트 외부 접합부의 이력 거동 (Cycle Behavior of Exterior Joint of Flat Plate Slab and Column)

  • 조종;하상수;한상환;이리형
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.239-242
    • /
    • 2005
  • The purpose of this research was focused on substantiating an effects of tendon-layouts and compressed stress($=f_{pc}$) induced by post-tensioning on seismic performance of post-tensioned flat plate slab-column connection designed as non-participating system. To accomplish this purpose, an experimental research of flat plate exterior slab-column connections subjected to gravity load and reversed lateral displacement history are presented. As a result, tendon-layout is a main variable to influence failure mechanism, dissipated energy and lateral deformation capacity. Furthermore, compressed stress ($=f_{pc}$) induced by post-tensioning enhanced the seismic performance of flat plate slab.

  • PDF

비부착식 단일 강연선용 원형 정착구를 적용한 포스트텐션 정착 구역의 보강 (Anchorage Zone Reinforcement for Unbonded Post-Tensioned Circular Anchorage for Single Tendon)

  • 김민숙;노경민;이영학
    • 한국공간구조학회논문집
    • /
    • 제18권3호
    • /
    • pp.117-124
    • /
    • 2018
  • In the post-tensioned concrete member, additional reinforcement is required to prevent failure in the anchorage zone. In this study, the details of reinforcement suitable for the anchorage zone of the post-tensioned concrete member using circular anchorage was proposed based on the experimental results. The tests were conducted with the compressive strength of concrete and reinforcement types as variables. The experimental results indicated that the additional reinforcement for the anchorage zone is required when the compressive strength of concrete is less than 17.5 MPa. U-shaped reinforcement shows most effective performance in terms of maximum strength and cracks patterns.

향요법이 대학생의 긴장형 두통, 스트레스 및 면역반응에 미치는 효과 (Effects of Aromatherapy on Headache, Stress and Immune Response of Students with Tension-Type Headache)

  • 한선희
    • 한국간호교육학회지
    • /
    • 제14권2호
    • /
    • pp.273-281
    • /
    • 2008
  • Purpose: This study was performed to investigate the effects of aromatherapy on headache, stress and immune response of students with tension-type headache. Method: This study employed a two-group pre-post test study design. Data was collected from 44 subjects. Twenty-two subjects were assigned to the experimental group and received aromatherapy massage every other day for 3 weeks, but the other 22 subjects were in the control group and did not receive any intervention. Experiment had been conducted from Apr. 9 through Aug. 25, 2001 and intensity of headache, stress response (serum cortisol, life stress) and immune response(T-cell and natural killer cell ratio) were measured in the course of aromatherapy for both experimental group and control group. Data were analyzed by using $X^2$-test, t-test, Paired t-test and repeated measures ANOVA. Result: Headache scores, serum cortisol levels and life stress scores were significantly decreased in the experimental group after treatment compared to the control group. Conclusion: These findings is suggested that the aromatherapy could be an effective nursing intervention in relaxing and relieving the pain caused by tension-type headache for students.

ETFE 필름의 2축 인장특성 및 텐션방식 막구조물의 응력완화 거동에 관한 실험적 연구 (An Experimental Study on Biaxial Tensile Characteristics of ETFE Film and Stress Relaxation of Tension Typed Membrane Structures)

  • 김승덕;정을석;카와바타 마사야
    • 한국공간구조학회논문집
    • /
    • 제16권1호
    • /
    • pp.35-42
    • /
    • 2016
  • Until recently, almost all ETFE film structures that have been erected is the cushion type because there are problems at lower allowable strength under elastic range and viscosity behaviour such as creep and relaxation of ETFE films under long-term stresses. But the number of tension type structures is currently increasing. This paper proposes the stretch fabrication of ETFE film to verify the applicability of ETFE films to tensile membrane structures. First of all, to investigate the possibility of application on tensile membrane structures, the stretch fabrication test is carried out, and it is verified that it is possible to increase the yield strength of the film membrane structures. After simulating the experiment also carries out an analytical investigation, and the effectiveness of the elasto-plastic analysis considering the viscous behavior of the film is investigated. Finally, post-aging tension measurement is conducted at the experimental facilities, and the viscosity behavior resulting from relaxation is investigated with respect to tensile membrane structures.

하부 철근 유무에 따른 포스트 텐션 플랫 플레이트 골조의 내진성능 평가 (Seismic Performance of Post Tensioned Flat Plate Structures according to Slab Bottom Reinforcement)

  • 한상환;황보진;유종혁;박영미
    • 한국지진공학회논문집
    • /
    • 제12권4호
    • /
    • pp.11-17
    • /
    • 2008
  • 본 연구에서는 슬래브 하부철근이 포스트 텐션(PT) 플랫 플레이트 골조의 내진성능에 미치는 영향을 평가하였다. 이를 위하여 슬래브-기둥 접합부에 슬래브 하부철근이 있는 경우와 없는 경우의3층, 9층 골조를 중력하중만 고려하여 설계하였다. 본 연구에서는 대상 건물을 비선형 정적 푸쉬오버 해석하여 기둥을 관통하는 슬래브 하부철근 유무에 따른 전체 구조시스템 거동을 평가하였다. 본 연구에서 사용한 접합부 모델은 뚫림 전단과 파괴메커니즘을 예측할 수 있도록 본 연구자들에 의하여 기존 연구에서 제안된 것이다. 본 연구 결과에 따르면 슬래브 하부철근은 PT 플랫 플레이트 골조의 내진성능에 큰 영향을 미치는 것으로 나타났다. 특히 슬래브 하부 철근이 있는 PT 플랫 플레이트 골조는 슬래브 하부철근이 없는 골조에 비하여 최대 강도와 변형 능력이 크게 향상되었다.

우정공무원의 스트레스와 웰빙에 대한 마음챙김-긍정심리 EAP 프로그램의 효과 (The Effects of Mindfulness-Positive Psychology EAP Program on Stress and Well-Being of Postal Workers)

  • 박예나;이지은;김세종;채정호
    • 대한불안의학회지
    • /
    • 제19권2호
    • /
    • pp.83-93
    • /
    • 2023
  • Objective : This study aimed to develop a customized EAP program for post office workder, incorporating mindfulness and positive psychology, and to test the effectiveness of the intervention on job burnout and well-being of the postal workers. Methods : Participants were currently working postal employees and were recruited voluntarily through the website of the Korea post human resources development institute. A total of 42 workers participated in the program until the end and completed preprogram and post program questionnaires. Results : The results showed that the mindfulness-positive psychology EAP program significantly improved the participants' mindfulness (t=-5.021, p<0.001), job burnout (t=5.824, p<0.001), self-esteem (t=-4.852, p<0.001), positive affect (t=-4.534, p<0.001), negative affect (t=5.635, p<0.001), and body tension (t=6.355, p<0.001), with statistically significant effects on all measures. Conclusion : The results indicated that the mindfulness-positive psychology EAP class had a significantly positive effect on increasing mindfulness, self-esteem, and positive affect and decreasing job burnout, negative affect, and body tension among postal workers, demonstrating the usefulness of an integrated approach.

고온을 받은 포스트텐션 콘크리트 보와 슬래브의 구조성능 연구 (A Study on the Structural Performance of Post Tensioned Concrete Beam and Slab Subjected to High Temperature)

  • 최광호;이중원
    • 콘크리트학회논문집
    • /
    • 제29권2호
    • /
    • pp.217-223
    • /
    • 2017
  • 이 연구는 포스트텐션 콘크리트 부재의 화재에 대한 구조성능 평가기술을 개발하기 위하여, 고온에 노출된 포스트텐션 보와 슬래브 부재의 구조특성과 평가기법을 내화 실험을 통하여 연구하였다. 내화 실험 시 가열은 전기로를 사용하였으며 수열온도를 $400^{\circ}C$, $600^{\circ}C$, $800^{\circ}C$로 하였다. 이 연구로부터 고온을 받는 강연선은 응력 이완이 발생되고, 냉각되면서 긴장력의 일부 복원이 나타나는 것을 알 수 있었다. 포스트텐션 보와 슬래브 실험체가 각각 목표온도 도달 후 4시간 경과 시 포스트텐션 부재의 강연선의 잔존 긴장력을 살펴보면, 포스트텐션 보는 $400^{\circ}C$에서는 70%, $600^{\circ}C$에서는 10%, $800^{\circ}C$에서는 2%정도로 볼 수 있으며, 포스트텐션 슬래브는 $400^{\circ}C$에서는 94%, $600^{\circ}C$에서는 84.5%, $800^{\circ}C$에서는 62%정도로 나타났다. 상대적으로 포스트텐션 슬래브의 잔존 긴장력 손실이 작았던 이유는 슬래브가 고온에 일면 노출되었고, 강연선의 강도복원이 일어났기 때문으로 여겨졌다. 이 연구로부터 화재가 발생하는 경우 포스트텐션 부재는 강도 및 긴장력의 손실이 발생하고, 보강 시 손실된 내력만큼의 복원설계가 필요함을 확인하였다.