DOI QR코드

DOI QR Code

Anchorage Zone Reinforcement for Unbonded Post-Tensioned Circular Anchorage for Single Tendon

비부착식 단일 강연선용 원형 정착구를 적용한 포스트텐션 정착 구역의 보강

  • Received : 2018.08.02
  • Accepted : 2018.08.17
  • Published : 2018.09.15

Abstract

In the post-tensioned concrete member, additional reinforcement is required to prevent failure in the anchorage zone. In this study, the details of reinforcement suitable for the anchorage zone of the post-tensioned concrete member using circular anchorage was proposed based on the experimental results. The tests were conducted with the compressive strength of concrete and reinforcement types as variables. The experimental results indicated that the additional reinforcement for the anchorage zone is required when the compressive strength of concrete is less than 17.5 MPa. U-shaped reinforcement shows most effective performance in terms of maximum strength and cracks patterns.

Keywords

References

  1. Hou, D. W., Zhao, J. L., Shen, J. S. L., & Chen, J., "Investigation and improvement of strut-and-tie model for design of end anchorage zone in post-tensioned concrete structure", Construction and Building Materials, Vol.136, pp.482-494, 2017 https://doi.org/10.1016/j.conbuildmat.2017.01.033
  2. KBC, Korean building code-structural, Architectural Institute of Korea, 2016.
  3. Haroon, S., Yazdani, N., & Tawfiq, K., "Posttensioned Anchorage Zone Enhancement with Fiber-Reinforced Concrete", Journal of Bridge Engineering, Vol.11, No.5, pp.566-572, 2006 https://doi.org/10.1061/(ASCE)1084-0702(2006)11:5(566)
  4. Axson, D. P. (2008). Ultimate Bearing Strength of Post-tensioned Local Anchorage Zone in Lightweight Concrete (Doctoral dissertation). Virginia Tech
  5. Cho, A. S., & Kang, T. H. K., "Load Transfer Test of Spirally Reinforced Anchorage Zone for Banded Tendon Group", Journal of Korean Association for Spatial Structures, Vol.17, No.1, pp.59-67, 2017 https://doi.org/10.9712/KASS.2017.17.1.059
  6. AASHTO, Standard specifications for highway bridges, Transportation Officials, 2002.
  7. Kim, M. S., Yoon, C. H., & Lee, Y. H., "Comparative Study of Bursting Force Equations for Post-Tensioned Anchorage Zones", Journal of Korean Association for Spatial Structures, Vol.17, No.4, pp.69-76, 2017 https://doi.org/10.9712/KASS.2017.17.4.069
  8. Lee, Y. H., Cho, Y. W., & Kim, M. S., "Development and Analysis of Unbonded Post-tensioned Anchorage for Single Tendon", Journal of the Computational Structural Engineering Institute of Korea, Vol.31, No.1, pp.39-46, 2018 https://doi.org/10.7734/COSEIK.2018.31.1.39