• 제목/요약/키워드: porosity

검색결과 3,545건 처리시간 0.024초

Free vibrational behavior of perfect and imperfect multi-directional FG plates and curved structures

  • Pankaj S. Ghatage;P. Edwin Sudhagar;Vishesh R. Kar
    • Geomechanics and Engineering
    • /
    • 제35권4호
    • /
    • pp.367-383
    • /
    • 2023
  • The present paper examines the natural frequency responses of the bi-directional (nx-ny, ny-nz and nz-nx) and multidirectional (nx-ny-nz) functionally graded (FG) plate and curved structures with and without porosity. The even and uneven kind of porosity pattern are considered to observe the influence of porosity type and porosity index. The numerical findings have been obtained using a higher order shear deformation theory (HSDT) based isometric finite element (FE) approach generated in a MATLAB platform. According to the convergence and validation investigation, the proposed HSDT based FE model is adequate to predict free vibrational responses of multidirectional porous FG plates and curved structures. Further a parametric analysis is carried out by taking various design parameters into account. The free vibrational behavior of bidirectional (2D) and multidirectional (3D) perfect-imperfect FGM structure is examined against various power law index, support conditions, aspect, and thickness ratio, and for the curvature of curved structures. The results indicate that the maximum non-dimensional fundamental frequency (NFF) value is observed in perfect FGM plates and curved structures compared to porous FGM plates and curved structures and it is maximum for FGM plates and curved structures with uneven kind of porosity than even porosity.

다공성 제올라이트의 특성을 이용한 기공율 추정 연구 (Porosity Estimation Using the Characteristics of Porous Zeolite)

  • 김혜지;이연숙;차진선
    • 청정기술
    • /
    • 제29권4호
    • /
    • pp.249-254
    • /
    • 2023
  • 본 연구에서는 제올라이트의 물리적 특성으로부터 기공율을 추정하는 연구를 수행하였다. 입자상 물질의 기공율 직접 측정의 어려움으로 본 연구에서는 여러 문헌에서 제시된 계산식에 제올라이트의 물리적 특성 측정값을 적용하여 기공율을 계산하였다. 이를 위해 제올라이트 3종-zeolite beta, zeolite Y, ZSM-5-에 대해 각각의 평균입자 크기 및 particle size distribution, 비표면적 및 기공특성을 측정하였으며, 가스와 액상을 이용한 진밀도, tap과 untapped를 적용한 겉보기 밀도를 측정하였다. 측정결과로부터 기공율을 계산하여 결과를 비교하고 기공율을 결정하는 주요 인자에 대해 평가하였다.

동애등에분변토와 코코피트가 혼합된 토양개량제가 모래의 이화학성에 미치는 영향 (Effects of Soil Amendment Blended with Soldier Fly Casts and Coco Peat on Physicochemical Properties of Sand Soil)

  • 김영선;이상범;함선규;임혜정;최영철;박관호
    • Weed & Turfgrass Science
    • /
    • 제3권2호
    • /
    • pp.143-149
    • /
    • 2014
  • 본 연구는 아메리카동애등에분변토(soldier fly casts; SFC)의 단점을 개량하기 위해 코코피트(cocopeat; Coco)와 혼합된 토양개량제의 골프장 토양개량제로서의 사용가능성을 평가하기 위해 모래와 혼합비율 별 물리화학성을 조사하였다. 토양개량제는 SFC, Coco, 25% SFC+75% Coco(Mix1), 50% SFC+50% Coco (Mix2) 및 75% SFC+25% Coco (Mix3)이었고, 각각 3%, 5%, 7% 및 10% 씩 혼합되어 모래상토를 조성하였다. SFC, Mix1, Mix2 및 Mix3는 토양 pH와 EC에서 고도의 상관성(P<0.01)을 나타내어 토양개량제의 혼합에 의해 모래상토의 토양화학성에 영향을 주었다. SFC, Coco, Mix1, Mix2 및 Mix3은 모세관공극, 비모세관공극 및 공극이 USGA기준에 적합하였고, 혼합비율이 증가할수록 모세관공극과 총공극이 증가하였으며(P<0.05), Mix1과 Mix3의 비모세관공극은 모세관공극과 수리전도도에서 부의 상관성을 보였다(P<0.01). Mix1, Mix2 및 Mix3에서 SFC는 상토의 모세관공극의 변화에 영향을 주었고, Coco는 모세관공극과 총공극의 변화에 영향을 주었다. 이들 결과를 종합할 때, SFC와 Coco가 혼합된 토양개량제(Mix1~3)는 SFC보다 모래상토의 모세관 공극과 수리전도도를 개선하여 SFC의 단점을 보완한 것으로 평가되었다.

Measurement of Porosity by EPMA-EDS Image Processing

  • Hung, Minhui;Li, Xiangting;Xia, Jiyu;Ding, Chuanxian
    • 한국진공학회지
    • /
    • 제6권S1호
    • /
    • pp.66-69
    • /
    • 1997
  • Porosity is one important characteristic feature and structural index of sprayed coatings. A method of measurement of porosity, EPMA-EDS image processing is developed in the paper. The characteristics of pores can be determined by processing of the image obtained from an electron microscope via VISTA, Not only the porosity can be presented but also the statistical result of pore size distribution. Finally it can be drawn from this paper that EPMA-EDS is a quite effective method to completely characterize the pores in plasma sprayed coatings.

  • PDF

고온하의 시멘트 경화체의 공극구조 (Pore Structure of Cement Matrix Exposed to High Temperatures)

  • 송훈;도정윤;소승영;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.509-512
    • /
    • 2003
  • Dehydration and micro crack thermal expansion occur in cement hydrates of concrete structure heated by fire for a long time. The characteristic of concrete exposed to high temperature can be analyzed from distribution of porosity and pore size. Porosity showed a tendency to increase irrespective of specimen types. This is due to both the outbreak of collapse of gel comprising the cement and a micro crack by heating. Porosity did not affect the variety of specimen and increased with the same tendency throughout every specimen. In addition, the deteriorate of compressive strength resulted from increase in porosity

  • PDF

Nonlinear static analysis of functionally graded porous beams under thermal effect

  • Akbas, Seref D.
    • Coupled systems mechanics
    • /
    • 제6권4호
    • /
    • pp.399-415
    • /
    • 2017
  • This paper deals with the nonlinear static deflections of functionally graded (FG) porous under thermal effect. Material properties vary in both position-dependent and temperature-dependent. The considered nonlinear problem is solved by using Total Lagrangian finite element method within two-dimensional (2-D) continuum model in the Newton-Raphson iteration method. In numerical examples, the effects of material distribution, porosity parameters, temperature rising on the nonlinear large deflections of FG beams are presented and discussed with porosity effects. Also, the effects of the different porosity models on the FG beams are investigated in temperature rising.

마이크로웨이브 오븐을 이용한 사암의 공극률 산출 방법 (A Method for Determining the Sandstone Porosity by Using a Microwave Oven)

  • 우슬기;김진후
    • 한국지구과학회지
    • /
    • 제38권2호
    • /
    • pp.150-160
    • /
    • 2017
  • 암석의 공극률을 산출하기 위해서는 일반적으로 한국암반공학회에서 정하고 있는 '암석의 공극률 및 밀도 측정 표준시험법'이 사용된다. 그러나 건조로를 이용하여 공극률을 구하는 이 같은 표준시험법은 8-24시간이 소요될 뿐만 아니라, 실험 도중 4시간 간격마다 시료를 꺼내어 무게를 측정해야 하는 번거로움이 있다. 이와 같은 단점을 보완하기 위해 본 연구에서는 마이크로웨이브 오븐을 이용하여 암석의 공극률을 측정하는 방법을 제안하였다. 마이크로웨이브 오븐에 무게 모니터링 시스템을 구축하여 무게 측정의 오차 발생 요인과 실험 과정의 번거로움을 줄였다. 건조과정에서 시료의 온도를 $105{\pm}3^{\circ}C$ 이내로 유지하기 위해 적절한 가열/휴지시간을 설정하였으며, 시료의 무게 변화량이 최초 무게의 0.1% 이내에 들면 모니터링을 중단할 수 있도록 알람 시스템도 구현하였다. 무게 모니터링 데이터에 곡선접합을 실시하여 시료의 건조무게를 구하고, 이를 이용하여 공극률을 산출하였으며, 이렇게 구한 공극률을 표준시험법으로 구한 공극률과 비교하였다. 사암을 이용해 실험한 결과, 마이크로웨이브 오븐으로 구한 공극률은 표준시험법으로 구한 공극률과 최대 0.4%의 오차를 보여 표준시험법의 결과와 유사하였다. 또한 동일 시료를 이용하여 공극률을 반복 측정한 결과, 표준편차가 최대 0.23% 정도로 정밀도 또한 양호하였다. 따라서 마이크로웨이브 오븐을 사용할 경우 높은 신뢰도로 공극률 산출이 가능할 것으로 판단된다.

The Critical Pigment Volume Concentration Concept for Paper Coatings: I. Model Coating Systems Using Plastic Pigments and Latex Binders for Paper Coating Applications

  • Lee, Do-Ik
    • 펄프종이기술
    • /
    • 제34권5호
    • /
    • pp.1-17
    • /
    • 2002
  • The immobilization and consolidation of the model coatings based on the plastic pigment and latex binder of known particle sizes were theoretically Studied in terms of the dense random packing of binary spheres and varying extent of latex film shrinkage. The porosity of the model coatings was calculated based on three proposed latex shrinkage models: Maximum, Minimum, and Linearly Decreasing Latex Shrinkage. The increasing extent of latex shrinkage was calculated up to the critical pigment volume concentration(CPVC) as a function of plastic pigment volume fractions, and the maximum latex shrinkage was estimated from the CPVC. Also, the number of pores and the average equivalent spherical pore diameters were calculated based on those proposed models. The opacity and gloss of the model coatings on polyester films were measured and their porosity was also determined by a simple coat weight-thickness method. As expected, various coating structure-property-composition relationships, such as opacity, gloss, porosity, etc., were shown to exhibit sharp transitions near the CPVC. The CPVC values determined by the opacity, gloss, and porosity vs. PVC relationships, respectively, agreed very well with each other. Especially, the CPVC's determined by the opacity and porosity vs. PVC curves were identical. The comparison between the theoretically calculated and experimental porosity values showed that the intermediate value between the maximum and minimum latex shrinkage would best fit the experimental porosity data. The effect of plastic pigment particle size on the optical properties and porosity of model coatings was also studied and it was observed that the coating opacity and porosity increased with increasing plastic pigment particle size, but the gloss decreased. The ink gloss of the uncalendered model coatings applied onto commercial sheet offset coated papers was shown to be affected by both the coating gloss and porosity: the higher the coating gloss, the higher the ink gloss, but the higher the coating porosity, the lower the ink gloss. Their printability was also studied in terms of the number of passes-to-fail and the rate of ink setting as a function of both plastic pigment volume fractions and plastic pigment particle sizes. A minimum crack-free temperature(MCR) of latex-bound coatings was proposed to better predict the behaviors of latexes as coating binders. The wet state of model coating dispersions, the surfaces of consolidated model coatings, and their internal structure were examined by both electron and atomic force microscopy, and their micrographs were found to be consistent with our immobilization and consolidation models.

파랑 중 제주 "테우" 틈에 의한 파 흡수효과 (Efficiency of wave absorption by the porous of "Taewoo" of Jeju in regular seaway)

  • 이창헌;최찬문;안장영;조일형
    • 수산해양기술연구
    • /
    • 제49권2호
    • /
    • pp.144-152
    • /
    • 2013
  • In an effort to find the optimum porous of Taewoo through the mathematical model 2 - dimensional tank water experiment among the approached to a problem related to ocean engineering, this study analyzed the porosity by dividing it into 9 cases. As the wave penetrates through the longitudinal porous of the Taewoo model, it was found that there is a wave energy loss because of the phenomenon of the separation of the porous due to the eddy. Looking into the general tendency based on the wave-height meter (probe) data, it was found that the shorter wavelength and higher frequency area, the more reflection coefficients increased, but in contrast, the longer wavelength and lower frequency area, the transmission coefficients showed the increasing trend and energy dissipation was in a similar way with reflection coefficients. In addition, it was found that the bigger the porosity was, the narrower distribution range of reflection coefficients was, and the more its average value decreased. On the other hand the transmission coefficients in direct opposition to reflection was found to show the wider range and the more gradual increase in the average value as porosity was the bigger around the average value. In contrast, energy dissipation rate was found to increase linearly as porosity increased the more around the porosity of 0.2518 but it decreased gradually around the peak point. Through the above results, it is judged that the porous of optimum in the longitudinal direction of the Taewoo model perforated plate was about 2.6cm because it was found that the porosity which produced the lowest reflection and transmission coefficient and the highest energy dissipation. As a result of comparing this to the case where there was no porosity at all, it showed the function of wave absorbing about 31.60%.

일축가압법으로 벌크흑연 제조 시 성형압력에 따른 열린기공률 변화가 함침 후 밀도 향상에 미치는 영향 (Effect of Change in Open Porosity as a Function of Uniaxial Molding Pressure on Density Improvement After Impregnation)

  • 이상민;이상혜;노재승
    • 한국분말재료학회지
    • /
    • 제28권1호
    • /
    • pp.7-12
    • /
    • 2021
  • The change in the open porosity of bulk graphite as a function of the uniaxial molding pressure during manufacturing is studied using artificial graphite powder. Subsequently, the graphite is impregnated to determine the effect of the open porosity on the impregnation efficiency and to improve the density of the final bulk graphite. Bulk graphite is manufactured with different uniaxial molding pressures after mixing graphite powder, which is the by-product of processing the final graphite products and phenolic resin. The bulk density and open porosity are measured using the Archimedes method. The bulk density and open porosity of bulk graphite increase as the molding pressure increases. The open porosity of molded bulk graphite is 25.35% at 30 MPa and 29.84% at 300 MPa. It is confirmed that the impregnation efficiency increases when the impregnation process is performed on a specimen with large open porosity. In this study, the bulk density of bulk graphite molded at 300 MPa is 11.06% higher than that before impregnation, which is the highest reported increase. Therefore, it is expected that the higher the uniaxial pressure, the higher the density of bulk graphite.