• 제목/요약/키워드: polymethylmethacrylate (PMMA)

검색결과 140건 처리시간 0.023초

1-D Photonic Crystals Based on Bragg Structure for Sensing and Drug Delivery Applications

  • Koh, Youngdae
    • 통합자연과학논문집
    • /
    • 제4권1호
    • /
    • pp.11-14
    • /
    • 2011
  • Free-standing multilayer distributed Bragg reflectors (DBR) porous silicon dielectric mirrors, prepared by electrochemical etching of crystalline silicon using square wave currents are treated with polymethylmethacrylate (PMMA) to produce flexible, stable composite materials in which the porous silicon matrix is covered with caffeine-impregnated PMMA. Optically encoded free-standing DBR PSi dielectric mirrors retain the optical reflectivity. Optical characteristics of free-standing DBR PSi dielectric mirrors are stable and robust for 24 hrs in a pH 12 aqueous buffer solution. The appearance of caffeine and change of DBR peak were simultaneously measured by UV-vis spectrometer and Ocean optics 2000 spectrometer, respectively.

Pullout Strength after Expandable Polymethylmethacrylate Transpedicular Screw Augmentation for Pedicle Screw Loosening

  • Kang, Suk-Hyung;Cho, Yong Jun;Kim, Young-Baeg;Park, Seung Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권4호
    • /
    • pp.229-234
    • /
    • 2015
  • Objective : Pedicle screw fixation for spine arthrodesis is a useful procedure for the treatment of spinal disorders. However, instrument failure often occurs, and pedicle screw loosening is the initial step of a range of complications. The authors recently used a modified transpedicular polymethylmethacrylate (PMMA) screw augmentation technique to overcome pedicle screw loosening. Here, they report on the laboratory testing of pedicle screws inserted using this modified technique. Methods : To evaluate pullout strengths three cadaveric spinal columns were used. Three pedicle screw insertion methods were utilized to compare pullout strength; the three methods used were; control (C), traditional transpedicular PMMA augmentation technique (T), and the modified transpedicular augmentation technique (M). After control screws had been pulled out, loosening with instrument was made. Screw augmentations were executed and screw pullout strength was rechecked. Results : Pedicle screws augmented using the modified technique for pedicle screw loosening had higher pullout strengths than the control ($1106.2{\pm}458.0N$ vs. $741.2{\pm}269.5N$; p=0.001). Traditional transpedicular augmentation achieved a mean pullout strength similar to that of the control group ($657.5{\pm}172.3N$ vs. $724.5{\pm}234.4N$; p=0.537). The modified technique had higher strength than the traditional PMMA augmentation technique ($1070.8{\pm}358.6N$ vs. $652.2{\pm}185.5N$; p=0.023). Conclusion : The modified PMMA transpedicular screw augmentation technique is a straightforward, effective surgical procedure for treating pedicle screw loosening, and exhibits greater pullout strength than traditional PMMA transpedicular augmentation. However, long-term clinical evaluation is required.

LIGA 공정 중 PMMA 현상 과정의 모사 (Simulation of the PMMA development course in LIGA process)

  • 임종석;이선아;구양모
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.733-736
    • /
    • 2000
  • In the first step of the LIGA process a resist layer, typically PMMA(polymethylmethacrylate), is pattered by deep X-ray lithography. Then the exposed parts are dissolved by an organic developer. To describe the developer. To describe the development course the parameters influencing the development process was investigated. The developed depth is proportional to the square root of the development time which suggests that the development rate increases with increasing dose value and temperature. So the development course can be described by a phenomenological equation.

  • PDF

이관능성 에폭시/폴리메틸메타크릴레이트 블랜드의 열적 및 기계적 계면 특성 (A Study on Thermal and Mechanical Interfacial Properties of Difunctional Epoxy/PMMA Blends)

  • 박수진;김기석;이재락;민병각;김영근
    • Composites Research
    • /
    • 제17권1호
    • /
    • pp.10-17
    • /
    • 2004
  • 본 연구에서는 이관능성 에폭시(DGEBA)와 polymethylmethacrylate(PMMA)를 블랜딩하여 열적 특성과 기계적 계면특성을 측정하였다. 열적 특성은 DSC, DMA, 그리고 TGA를 이용하였으며, 블랜드의 기계적 계면특성을 측정하기 위해 contact angle로 표면자유에너지를 조사하였고, 파괴인성은 $K_{IC}$로 측정하고 $K_{IC}$ 실험 후 파괴단면을 SEM을 이용하여 관찰하였다. 실험 결과, 경화 온도와 유리전이 온도는 PMMA의 첨가에 의해 증가하는 것을 확인할 수 있었다. 또한 블랜드의 표면자유에너지는 PMMA의 저함량에서 높은 값을 나타내었고, 이는 비극성 요소의 증가와 극성 요소의 존재에 의한 것으로 판단된다. 블랜드의 파괴인성 측정 결과 5 phr에서 최대값을 나타내었다. 이는 DGEBA/PMMA 간의 상용성 또는 거대분자 사슬에서 물리적 결합의 증가에 기인하는 것으로 판단된다.

극미세 점 구조체 제작을 위한 나노압입 공정에서 PMMA의 시간의존적 변형거동에 관한 연구 (A Study on the Time-Dependent Deformation Behaviors of PMMA in Nanoindentation Process for Hyperfine Pit Structure Fabrication)

  • 김현일;강충길;윤성원
    • 한국정밀공학회지
    • /
    • 제22권7호
    • /
    • pp.62-70
    • /
    • 2005
  • The nanoindenter and AFM have been used for nanofabrication, such as nanolithography, nanowriting, and nanopatterning, as well as measurement of mechanical properties and surface topology. Nanoscale indents can be used as cells for molecular electronics and drug delivery, slots for integration into nanodevices, and defects for tailoring the structure and properties. Therefore, it is very important to make indents of desired morphology (shape, size and depth). Indents of different shapes can be obtained by using indenters of different geometries such as a cube comer and conical and spherical tips. The depth and size of indents can be controlled by making indentations at different indentation loads. However, in case of viscoplastic viscoelastic materials such as polymethylmethacrylate (PMMA) the time dependent deformation (TDD) should also be considered. In this study, the effect of process parameters such as loading rate and hold-time at peak load on the indent morphology (maximum penetration depth, elastic recovery, transient creep recovery, residual depth pile-up height) of PMMA were studied for hyperfine pattern fabrication.

A Case of Pedicle Screw Loosening Treated by Modified Transpedicular Screw Augmentation with Polymethylmethacrylate

  • Kang, Suk-Hyung;Kim, Kyoung-Tae;Park, Seung-Won;Kim, Young-Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권1호
    • /
    • pp.75-78
    • /
    • 2011
  • We report a case of pedicle screw loosening treated by modified transpedicular screw augmentation technique using polymethylmethacrylate(PMMA), which used the anchoring effect of hardened PMMA. A 56-year-old man who had an L3/4/5 fusion operation 3 years ago complained of continuous low back pain after this operation. The computerized tomography showed a radiolucent halo around the pedicle screw at L5. We augmented the L5 pedicle screw with modified pedicle screw augmentation technique using PMMA and performed an L3/4/5 pedicle screw fixation without hook or operation field extension. This modified technique is a kind of transpedicular stiffness augmentation using PMMA for the dead space around the loosed screw. After filling the dead space with 1-2 cc of PMMA, we inserted a small screw. Once the PMMA hardened, we removed the small screw and inserted a thicker screw along the existing screw threading to improve the pedicle screws' pullout strength. At 10 months' follow-up, x-ray showed strong fusion of L3/4/5. The visual analogue scale (VAS) of his back pain was improved from 9 to 5. This modified transpedicular screw augmentation with PMMA using anchoring effect is a Simple and effective surgical technique for pedicle screw loosening. However, clinical analyses of long-term follow-up and biomechanical studies are needed.

골다공증성 척추 압박골절 환자의 경피적 척추성형술에서 Polymethylmethacrylate의 경막 외 유출 (Epidural Leakage of Polymethylmethacrylate Following Percutaneous Vertebroplasty in the Patients with Osteoporotic Vertebral Compression Fractures)

  • 오윤규;류경식;박춘근;강준기
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권3호
    • /
    • pp.319-324
    • /
    • 2001
  • Objectives : The percutaneous vertebroplasty provides a good result in the treatment of osteoporotic vertebral compression fractures. But, the epidural leakage of polymethylmetacrylate(PMMA) after vertebroplasty may decrease the therapeutic effects because of the compression of thecal sac and/or nerve roots. The authors carried out a prospective study to evaluate the causative factors of epidural leakage of PMMA and to assess the influence on the outcome. Methods : This study involved 347 vertebral levels of compression fractures in 159 patients. Among these, the epidural leakages were identified in 92 vertebral levels(26.5%) in 64 patients(40.3%) on post-operative CT scan. Results : The incidence of epidural leakage of PMMA was significantly higher in the level above T7(p=0.001). The large amount of the injected PMMA and the use of an injector also increased the incidence(p=0.03 and p=0.045, respectively). The position of the needle tip in the vertebral body and the pattern of venous drainage did not influence. The immediate post-operative visual analogue scale(VAS) scores and facial scales(FS) were higher in the patients with epidural leakage(p=0.009). But there were no significant differences between the two groups after three months of operation(p=0.541). Conclusions : The incidence of epidural leakage of PMMA after percutaneous vertebroplasty appears to have relationship with the amount of PMMA and the levels injected. The epidural leakage of PMMA reduced the immediate therapeutic effects of vertebroplasty, but did not influence the late outcome. However, the epidural leakage should be avoided because of its potential neurological complications.

  • PDF

열장 흐름 분획법에서 중력효과에 의한 고분자의 머무름 거동에 관한 연구 (A Study on the Gravitational Effect Influencing Retention Behavior of Polymer in Thermal Field Flow Fractionation)

  • 류기석;송병수;박종원;민병열
    • 대한화학회지
    • /
    • 제39권11호
    • /
    • pp.848-855
    • /
    • 1995
  • 평판형 열장흐름분획법에서 중력효과에 의한 polystyrene(PS)와 polymethylmethacrylate(PMMA)의 머무름 거동에 관하여 연구하였다. 하향 이동상 흐름의 경우 이동상 흐름 방향과 같은 방향으로 작용하는 중력 효과는 수평면 으로부터 장치각도가 0.deg.에서 60.deg.까지 변화함에 따라 증가하였다. 이 효과는 PS와 PMMA의 머무름 시간을 작게 하였고, 무차원 변수 .lambda.의 값을 증가시켰다. 그리고 분자량이 다른 두개의 고분자 머무름 시간차를 감소시켜 분리기능 저하시켰다. 상향 이동상 흐름의 경우 이동상 흐름의 반재 방향으로 작용하는 중력 효과는 수평면으로부터 장치의 각도가 0.deg.에서 60.deg.까지 증가함에 따라 증가하였다. 이 효과는 PS와 PMMA의 머무름 시간을 크게 하였고, 무차원 변수.lambda.의 값을 감소 시켰다. 그리고 분자량이 다른 두 개의 고분자 머무름 시간 차를 증가시켜 분리능을 향상시켰다.

  • PDF

Berkovich 팁을 이용한 PMMA의 초미세 가공에서 가공속도가 변형거동에 미치는 영향

  • 윤성원;김현일;강충길
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 춘계학술대회 논문요약집
    • /
    • pp.147-147
    • /
    • 2004
  • 폴리메틸메타크릴레이트(polymethylmethacrylate, PMMA)는 아크릴레이트계 고분자이자 열가소성 플라스틱으로써 LCD용 도광판, 콘택트렌즈, 치과용 레진, DVD 디스크용 소재, 나노임프린트용 피가공재, 나노리소그래피 공정용 레지스트 등 많은 분야에서 활발히 사용되고 있다. PMMA 와 같은 점소성 점탄성 소재의 기계적 성질 측정 및 가공을 위해서는, 응력완화 (stress relaxation), 크립 (creep)등과 같은 시간의존적 변형거동에 대한 연구가 선행되어야 한다.(중략)

  • PDF

Fabrication of Resistive Switching Memory based on Solution Processed AlOx - PMMA Blended Thin Film

  • 신중원;백일진;조원주
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.181.1-181.1
    • /
    • 2015
  • 용액 공정을 이용한 Resistive random access memory (ReRAM)은 간단한 공정 과정, 대면적화, 저렴한 가격 등의 장점으로 인해 큰 관심을 받고 있으며, HfOx, TiOx, AlOx 등의 산화물이 ReRAM 절연 막으로 주로 연구되고 있다. 더 나아가 최근에는 organic 물질을 메모리 소자로 사용한 연구가 보고되고 있다. 이는 경제적이며, wearable 또는 flexible system에 적용이 용이하다. 그럼에도 불구하고, organic 물질을 갖는 메모리 소자는 기존의 산화물 소자에 비해 열에 취약하며 전기적인 특성과 신뢰성이 우수하지 못하다는 단점을 가지고 있다. 이를 위한 방안으로 본 연구에서는 AlOx - polymethylmethacrylate (PMMA) blended thin film ReRAM을 제안하였다. 이는 organic물질의 전기적 특성을 개선시킬 뿐 아니라, inorganic 물질을 wearable 소자에 적용했을 때 발생하는 crack과 같은 기계적 물리적 결함을 해결할 수 있는 새로운 방법이다. 먼저, P-type Si 위에 습식산화를 통하여 SiO2 300 nm 성장시킨 기판을 사용하여 electron beam evaporation으로 10 nm의 Ti, 100 nm의 Pt 층을 차례로 증착하였다. 그리고 PMMA 용액과 AlOx 용액을 초음파를 이용하여 혼합한 뒤, 이 용액을 Pt 하부 전극 상에서 spin coating방법으로 1000 rpm 10초, 5000 rpm 30초의 조건으로 증착하였다. Solvent 및 불순물 제거를 위하여 150, 180, $210^{\circ}C$의 온도로 30 분 동안 열처리를 진행하였고, shadow mask를 이용하여 상부 전극인 Ti를 sputtering 방식으로 100 nm 증착하였다. 150, 180, $210^{\circ}C$로 각각 열처리한 AlOx - PMMA blended ReRAM의 전기적 특성은 HP 4156B semiconductor parameter analyzer를 이용하여 측정하였다. 측정 결과 제작된 소자 전부에서 2 V이하의 낮은 동작전압, 안정된 DC endurance (>150cycles), 102 이상의 높은 on/off ratio를 확인하였고, 그 중 $180^{\circ}C$에서 열처리한 ReRAM은 더 높은 on/off ratio를 갖는 것을 확인하였다. 결론적으로 baking 온도를 최적화하였으며 AlOx - PMMA blended film ReRAM의 우수한 메모리 특성을 확인하였다. AlOx-PMMA blended film ReRAM은 organic과 inorganic의 장점을 갖는 wearable 및 system용 비휘발성 메모리소자에 적용이 가능한 경제적인 기술로 판단된다.

  • PDF