• Title/Summary/Keyword: polyamide

Search Result 407, Processing Time 0.028 seconds

Surface roughness and $Candida$ $albicans$ adhesion to flexible denture base according to various polishing methods (연마방법에 따른 탄성의치의 표면거칠기와 $Candida$ $albicans$의 부착율 변화)

  • Oh, Ju-Won;Seo, Jae-Min;Ahn, Seung-Keun;Park, Ju-Mi;Kang, Cheol-Kyun;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.106-111
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the effect of 3 chairside polishing methods and laboratory polishing methods on surface roughness and $C.$ $albicans$ adhesion of polyamide denture base. Materials and methods: Using contact profilometer, the surface of polyamide specimens ($25{\times}15{\times}2mm$) was studied after conventional polishing without finishing and after chiarside polishing with 2 chiarside polishing kits and chairside-pumice polishing following finishing with tungsten carbide bur. To evaluate the adhesion of $C.$ $albicans$, $C.$ $albicans$ suspension was overlayed on the test specimen. And the specimens were incubated for 2 hours. Imprint culture method was achieved and counted the colony on the agar plate. Polished polyamide were evaluated using a scanning electron microscope. The statistics were conducted using one-way ANOVA and in case of difference, Scheffe test and Tamhane's T2 test were used. Results: Surface roughness (Ra) of surfaces polished with 2 chairside polishing kits had higher than conventional polishing and pumice polishing. The highest roughness value was $0.32{\pm}0.10{\mu}m$, and the lowest was $0.02{\pm}0.00{\mu}m$. The adhesion of $C.$ $albicans$ on the specimens polished with chairside polishing group and pumice polishing group were increased than conventional polishing group ($P$<.01). Conclusion: Conventional laboratory polishing was found to produce the smoothest surface and the lowest adhesion of $C.$ $albicans$. Two groups polished with Chairside polishing kits were similar with respect to surface roughness. Surface of the specimen polished with pumice is significantly smoother than 2 chairside polishing groups, but the result of $C.$ $albicans$ adhesion is that group polished with pumice was similar with 2 chairside polishing groups ($P$>.01).

Peel strength of denture liner to PMMA and polyamide: laser versus air-abrasion

  • Korkmaz, Fatih Mehmet;Bagis, Bora;Ozcan, Mutlu;Durkan, Rukiye;Turgut, Sedanur;Ates, Sabit Melih
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.287-295
    • /
    • 2013
  • PURPOSE. This study investigated the effect of laser parameters and air-abrasion on the peel strength of silicon-based soft denture liner to different denture resins. MATERIALS AND METHODS. Specimens (N=180) were prepared out of three different denture base resins (Rodex, cross-linked denture base acrylic resin; Paladent, heat-cured acrylic resin; Deflex, Polyamide resin) ($75mm{\times}25mm{\times}3mm$). A silicon-based soft denture liner (Molloplast B) was applied to the denture resins after the following conditioning methods: a) Air-abrasion ($50{\mu}m$), b) Er,Cr:YSGG laser (Waterlase MD Turbo, Biolase Technology) at 2 W-20 Hz, c) Er,Cr:YSGG laser at 2 W-30 Hz, d) Er,Cr:YSGG laser at 3 W-20 Hz, e) Er,Cr:YSGG laser at 3 W-30 Hz. Non-conditioned group acted as the control group. Peel test was performed in a universal testing machine. Failure modes were evaluated visually. Data were analyzed using two-way ANOVA and Tukey's test (${\alpha}$=.05). RESULTS. Denture liner tested showed increased peel strength after laser treatment with different parameters ($3.9{\pm}0.4-5.58{\pm}0.6$ MPa) compared to the control ($3.64{\pm}0.5-4.58{\pm}0.5$ MPa) and air-abraded groups ($3.1{\pm}0.6-4.46{\pm}0.3$ MPa), but the results were not statistically significant except for Paladent, with the pretreatment of Er,Cr:YSGG laser at 3 W-20 Hz. Polyamide resin after air-abrasion showed significantly lower peel strength than those of other groups ($3.1{\pm}0.6$ MPa). CONCLUSION. Heat-cured acrylic resin, PMMA, may benefit from Er,Cr:YSGG laser treatment at 3 W-20 Hz irradiation. Air-abrasion of polyamide resins should be avoided not to impair their peel bond strengths to silicon-based soft denture liners.

Synthesis and Characterization of Polymer and Polymer Complex with Some Transition Metal Ions (몇 개의 전이금속 이온과 고분자와 고분자 Complex의 합성과 특성연구)

  • Badr, S.K.;Mohamed, T.Y.
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.1
    • /
    • pp.43-48
    • /
    • 2010
  • Polyamide derived from azo compound of o-amino phenol coupled with acetyl acetone, maleic anhydride acid and p-phenylene diamine were prepared. The prepared polyamide (PA) was refluxed with metal salts of transition metal ions include, $Co^{+2},\;Cr^{+2},\;Ni^{+2},\;Cu^{+2},\;Zn^{+2},\;Cd^{+2}$ and $Fe^{+3}$ in dimethyl formamide (DMF) in different molar ratios. These complexes were characterized and identified by elemental and thermal analysis, IR, 1H NMR spectra. The data showed that PA ligand coordinates with metal ions in abidentate manner through donating N=N and O-H groups. The metal ions are surrounded by coordinated water molecules and anions to establish the geometrical structure of the complexes. The thermal analysis degradation at different temperatures explained the weight loss of hydrated water and the decompositions of complexes until a constant weight loss of metal oxides is obtained.

A Study on the Polyamide Based Thermoplastic Composites for Fuel Cell Separators (연료전지 분리판용 폴리아미드계 복합체의 특성 연구)

  • Lee, Kwang-Yong;Kim, Jeong-Heon;Ryu, Sung-Hun
    • Elastomers and Composites
    • /
    • v.43 no.4
    • /
    • pp.253-258
    • /
    • 2008
  • In this study polyamide 6,6 based thermoplastic composite with graphite and carbon black had been examined feasibility for separators of fuel cell which requires good mechanical and electrical properties with gas impermeability. The effects of molding pressure and filler content on the properties of the composite were investigated. Maximum flexural modulus was obtained about 80 wt% graphite, while electrical conductivity increased with graphite content. Flexural strength increased with molding pressure and tended to level-off from $400\;kgf/cm^2$. Molding pressure did not affect the electrical conductivity. The addition of carbon black enhanced the electrical conductivity of the composite. Mechanical properties were decreased under acidic condition.

Fabrication of unidirectional commingled-yarn-based carbon fiber/polyamide 6 composite plates and their bend fracture performances (일방향 혼합방사형 탄소섬유/폴리아미드 6 복합재료판의 제작조건과 굽힘파괴거동)

  • Choi, Nak-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.2
    • /
    • pp.416-427
    • /
    • 1998
  • Unidirectional commingled-yarn-based carbon fiber(CF)/polyamide(PA) 6 composite was fabricated under molding pressures of 0.4, 0.6 and 1.0 MPa to study its flexural deformation and fracture behavior. Fiber/matrix interfacial bonding area became larger with an increase of molding pressure from 0.4 to 0.6 MPa. For molding pressures .geq. 0.6 MPa, good flexural performance of similar magnitudes was attained. For the fracture test, four kinds of notch direction were adopted : edgewise notches parallel (L) and transverse (T) to the major direction of fiber bundles, and flatwise notches parallel(ZL) and perpendicular(ZT) to this direction. Nominal bend strength for L and ZL specimens exhibited high sensitivity to notching. ZL specimens revealed the lowest values of the critical stress intensity factor $K_c$ which was slightly superior to those of unfilled PA6 matrix. Enlargement of the compression area for T specimens was analyzed by means of the rigidity reduction resulting from the fracture occurrence.

Enhancement of Dielectric Properties of Polyamide Enamel Insulation in High Voltage Apparatuses Used in Medical Electronics by Adding Nano Composites of SiO2 and Al2O3 Fillers

  • Biju, A.C.;Victoire, T. Aruldoss Albert;Selvaraj, D. Edison
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1712-1719
    • /
    • 2015
  • In recent days, there was a significant development on the electrical, thermal, mechanical, physical, chemical, magnetic and optical properties of the polyamide enamel, varnish and other insulating materials by the addition of nano fillers to it. Enamel was used in High Voltage Apparatuses used in Medical Electronics as insulation. Insulating materials determine the life time of the electrical apparatuses. The life time of the insulating materials was improved by the addition of nano fillers to it. Hence the life time of the electrical apparatuses was improved by the mixing of nano fillers to the enamel. In this research, the basic dielectric properties of the enamel and enamel mixed with nano composites of silica and alumina were analyzed and compared with each other. The addition of nano fillers has improved the quality factor and capacitance of the enamel. It was also observed that the addition of nano fillers has reduced the dissipation factor and dielectric losses of the enamel. Heat produced by the dielectric losses was also reduced by adding nano fillers to it.

Workability and Strength Properties of Hybrid Fiber Reinforced Concrete Using Amorphous Steel Fiber and Organic Fiber (비정질 강섬유와 유기섬유를 이용한 하이브리드 섬유보강 콘크리트의 작업성 및 강도 특성)

  • Kwon, Soon-Oh;Bae, Su-Ho;Lee, Hyun-Jin;Kim, Jin-Oo;Lee, Jun-Cheol
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.4
    • /
    • pp.58-63
    • /
    • 2015
  • The purpose of this experimental research is to evaluate the workability and strength properties of hybrid fiber reinforced concrete containing amorphous steel fiber and organic fiber. For this purpose, the hybrid fiber reinforced concrete containing amorphous steel fiber(ASF) with polyamide(PA) and polyvinyl alcohol(PVA) fiber, respectively were made according to their total volume fraction of 0.5% for water-binder ratio of 33%, and then the characteristics such as the workability, compressive strength, and flexural strength of those were investigated. It was observed from the test results that the workability and compressive strength at 7 and 28 days were decreased and the flexural strength at 7 and 28 days was increased with increasing ASF and decreasing organic fiber.

Reactive Compatibilization of Amorphous Poly-${\alpha}$-olefins/Amorphous Polyamide Blends (무정형 알파-올레핀 고분자/무정형 폴리아미드 블렌드의 반응 상용화)

  • Yun, Deok-Woo;Choi, Mi-Ju;Hwang, Kyu-Hee;Kim, Geon-Seok;Lee, Kwang-Hee
    • Polymer(Korea)
    • /
    • v.33 no.5
    • /
    • pp.490-495
    • /
    • 2009
  • The reactive compatibilization of amorphous poly-${\alpha}$-olefins (APAO)/amorphous polyamide (aPA) blends was carried out using two kinds of reactive compatibilizers such as maleated polypropylene and ethylene-glycidyl methacrylate-methyl acrylate copolymer. The grafting reaction rates between aPA and the compatibilizers were examined using FT-IR, SEM and rheometer. The effect of the reactive compatibilization on the mechanical property of the blends was investigated with a universal testing machine. The adhesion strength of the blends including a hydrocarbon tackifier resin, C9 was also measured.