• Title/Summary/Keyword: polishing methods

Search Result 199, Processing Time 0.028 seconds

Specialty Fiber Coupler: Fabrications and Applications

  • Lee, Byeong-Ha;Eom, Joo-Beom;Park, Kwan-Seob;Park, Seong-Jun;Ju, Myeong-Jin
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.326-332
    • /
    • 2010
  • We review the research on specialty fiber couplers with emphasis placed on the characteristics that make them attractive for biomedical imaging, optical communications, and sensing applications. The fabrication of fiber couplers has been carried out with, in addition to conventional single mode fiber, various specialty fibers such as photonic crystal fiber, double clad fiber, and hole-assisted fiber with a Ge-doped core. For the fiber coupler fabrication, the side polishing and the fused biconical tapered methods have been developed. These specialty fiber couplers have been applied to optical coherence tomography, fluorescence spectroscopy, fiber sensors, and optical communication systems. This review aims to provide a detailed statement on the recent progress and novel applications of specialty fiber couplers.

A Study of the Effects of Pressure Velocity and Fluid Viscosity in Abrasive Machining Process (입자연마가공에서의 압력 속도 및 유체점도의 영향에 대한 고찰)

  • Yang, Woo-Yul;Yang, Ji-Chul;Sung, In-Ha
    • Tribology and Lubricants
    • /
    • v.27 no.1
    • /
    • pp.7-12
    • /
    • 2011
  • Interest in advanced machining process such as AJM(abrasive jet machining) and CMP(chemical-mechanical polishing) using micro/nano-sized abrasives has been on the increasing demand due to wide use of super alloys, composites, semiconductor and ceramics, which are difficult to or cannot be processed by traditional machining methods. In this paper, the effects of pressure, wafer moving velocity and fluid viscosity were investigated by 2-dimensional finite element analysis method considering slurry fluid flow. From the investigation, it could be found that the simulation results quite corresponded well to the Preston's equation that describes pressure/velocity dependency on material removal. The result also revealed that the stress and corresponding material removal induced by the collision of particle may decrease under relatively high wafer moving speed due to the slurry flow resistance. In addition, the increase in slurry fluid viscosity causes the reduction of material removal rate. It should be noted that the viscosity effect can vary with the shape of abrasive particle.

A Requirements Driven System Design Process for a Small System (소규모 시스템의 요건에 의한 설계)

  • Kim, Eui-Jung;Shin, Keun-Ha;Choi, Jae-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.10
    • /
    • pp.69-75
    • /
    • 2001
  • Systems engineering has been utilized in system development primarily for large-scale projects or commercial large-scale systems during the last several decades. We can understand why it would be useful to apply systems engineering to the development of a relatively small system. However, it is difficult to effectively carry out a project due to the complexity in applying the methods of systems engineering. To apply systems engineering to the development of a small system, the system engineering processes should be tailored. We established a requirements driven system design process(RDSDP) that can effectively carry out the system design far a small system. RDSDP is a system design process that treats all the requirements thoroughly and effectively. This is applied by the designer according to a standardized and systematized process during the first phase in design, in which system specifications are made. By using RDSDP, we can affect a reduction of the number of redesign phases in the process of the system design, shorten the period for to make specification, which will then cause the system to succeed in the actual application.

  • PDF

Development of the Processing System for Pre-washed Rice

  • Choi H. S.;Cho K. H.;Park H. M.;Kim Y. H.;Keum D. H.
    • Agricultural and Biosystems Engineering
    • /
    • v.5 no.2
    • /
    • pp.60-63
    • /
    • 2004
  • Demand for development of processing systems for pre-washed rice and propagation of the systems has recently been on the rise, because rice-cooking requires watering 15 times the rice quantity to cook, as in case of the regular rice currently being circulated in Korean market, in addition to paying the trouble of washing it for cooking, and besides the milky turbid water coming from the rice-washing contributes to water contamination. In this study, therefore, a processing system for pre-washed rice was designed and built with rice surface polishing devices that adopted abrading and airing methods, an electrostatic method and a method using a fine watering, to conduct its performance test. The result showed that turbidity of the wash water, which is the base to determine the pre-washed rice standard, turned out 47.33 ppm and 48.00 ppm respectively for 800 kg/hr and 1,000 kg/hr supplies, which meets the standard for the processing system free from rice-washing for cooking. The quantity of watering at this experiment was only 0.43 times the rice, thus resulting in curtailment of process-watering by approximately $69\%$ compared with the existing wet-type pre-washed rice processing system popular in Korean market.

  • PDF

The plaque-removing efficacy of a single-tufted brush on the lingual and buccal surfaces of the molars

  • Lee, Dong-Won;Moon, Ik-Sang
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.3
    • /
    • pp.131-134
    • /
    • 2011
  • Purpose: To test the plaque-removal efficacy of a single-tufted toothbrush on the posterior molars compared with a flat-trimmed toothbrush. Methods: Forty-nine subjects were selected. Professional instruction and written brushing instructions were given. After thorough supra-gingival scaling and polishing, all subjects were asked to abstain from oral hygiene procedures for 24 hours prior to the first experiment. The subjects were randomized to a treatment sequence. The modified Quigley and Hein plaque index was recorded pre- and post-tooth brushing, at 6 surfaces of the posterior molars. After a wash-out period, all the remaining plaque was removed professionally. Twenty-four hours of brushing abstinence was again performed. The plaque index was recorded pre- and post-tooth brushing after the subjects were given the second toothbrush in the cross-over sequence. Results: The percentage reductions in plaque scores achieved with the single-tufted brushes were significantly higher than those of the flat-trimmed brush at the maxillary buccal interproximal, marginal and mandibular lingual interproximal site. The other locations showed no significant difference. Conclusions: The results of the present study implied that the single-tufted brush could be an effective tool for the removal of plaque at some, but not all, sites of the posterior molars.

A study on the production environment of crown prosthesis for National Health Insurance benefit (건강보험 급여화 관련 크라운보철물 제작실태 연구)

  • Cho, Mi-Hyang;Lee, Hee-Kyung;Nam, Shin-Eun
    • Journal of Technologic Dentistry
    • /
    • v.40 no.2
    • /
    • pp.73-82
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the production environment of crown prosthesis for National Health Insurance(NHI) benefit. Methods: This study carried out self-administered questionnaire survey from September 1, 2016 to October 31 by having research subjects as 261 dental technician. Except 100 copies with incomplete response, 161 copies were used as the materials of final analysis. Results: Unlike gold crowns, the material cost of metal crowns was paid at the dental laboratory(86.3%). Total material consumption for making metal crown was more than gold crown(63.4%), especially for the finishing and polishing processes(78.3%). The subjects responded that a routine dental laboratory fee of crown prosthesis is unreasonable, and it is necessary to adjust and improve it(metal crown 96.2%, gold crown 96.9%). NHI coverage dental prosthesis was not marked on the order form(46.0%), and the dental laboratory fee of that was nor received(64.0%). Conclusion : It is necessary to estimate the NHI cost level of the crown prosthesis by reflecting the production environment and engineering process in dental laboratories. In addition, institutional arrangement should be backed up so that dental laboratories can receive appropriate dental laboratory fee.

COLOR STABILITY OF CEROMERS AFTER THERMOCYCLING AND BRUSHING (잇솔질과 열처리가 세로머의 색안정성에 미치는 영향)

  • Yi Yang-Jin;Cho Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.37-48
    • /
    • 2001
  • Ceromers, new indirect resin system, are now being adopted for esthetic restorations. Despite of its translucency and good color matching, color stability after long-term use was unknown till now. This in vitro study was designed to evaluate color stability of some ceromers when subjected to brushing after thermocycling. Three types of ceromers: Scupture, Targis, Artglass and a direct resin system, Z100 were prepared to disks 12 mm in diameter, 2.5 mm in thickness. All specimens were polished, and Sculpture and Targis specimens were divided two groups, respectively. Then, half of them were glazed according to manufacturer's instructions. All specimen were brushed 20,000 times after 10,000 cycle thermocycling. Color was measured with spectrophotometer after 1,000, 3,000, 10,000 times thermocycling and 20,000 time brushing, respectively. Color difference (${\Delta}E$) was calculated according to CIE LAB system. During thermocycling, Sculpture & Targis system with polished surface showed greater color change than any other groups. After brushing, color difference was reduced significantly. Mean values of ${\Delta}E$ ranged 0.98 to 2.98. All Ceromers were considered clinically acceptable after thermocycling and brushing, and color change mechanism was affected by the brands and finishing methods. It might be concluded that color change of ceromer is due to surface alteration.

  • PDF

Electro-Catalytic Oxidation of Amoxicillin by Carbon Ceramic Electrode Modified with Copper Iodide

  • Karim-Nezhad, Ghasem;Pashazadeh, Ali;Pashazadeh, Sara
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.3
    • /
    • pp.322-328
    • /
    • 2013
  • Copper iodide was employed as a modifier for preparation of a new carbon ceramic electrode. For the first time, the catalytic oxidation of amoxicillin (AMX) was demonstrated by cyclic voltammetry, chronoamperometry and amperometry methods at the surface of this modified carbon ceramic electrode. The copper iodide modified sol-gel derived carbon ceramic (CIM-SGD-CC) electrode has very high catalytic ability for electrooxidation of amoxicillin. The catalytic oxidation peak current was linearly dependent on the amoxicillin concentration and the linearity range obtained was 100 to 1000 ${\mu}mol\;L^{-1}$ with a detection limit of 0.53 ${\mu}mol\;L^{-1}$. The diffusion coefficient ($D=(1.67{\pm}0.102){\times}10^{-3}\;cm^2\;s^{-1}$), and the kinetic parameter such as the electron transfer coefficient (${\alpha}$) and exchange current density ($j_0$) for the modified electrode were calculated. The advantages of the modified CCE are its good stability and reproducibility of surface renewal by simple polishing, excellent catalytic activity and simplicity of preparation.

Influence of coloring liquids on the shear bond strength between zirconia and veneering ceramic (색소체용액 침투가 지르코니아 및 전장용 세라믹의 전단결합강도에 미치는 영향)

  • Jung, Jong-Hyun;Oh, Gye-Jeong
    • Journal of Technologic Dentistry
    • /
    • v.38 no.4
    • /
    • pp.291-298
    • /
    • 2016
  • Purpose: This study was to evaluate the effect of coloring liquids on the shear bond strength between zirconia and veneering ceramic. Methods: Zirconia(15 mm in diameter, 2.5 mm in thickness; n=40) used in the experiment were divided into 5 groups depending on the coloring liquid. Each specimen were polished using a polishing machine(LaboPol-2, Struers, UK). A cylinder of veneering porcelain(6 mm in diameter, 3 mm in thickness) was fabricated and fired on zirconia surfaces. The shear bond strength was measured using a universal testing machine(Model 4302, Instron, USA). All data were analyzed statistically using a one-way ANOVA and Tukey's multiple comparisons test. After the shear bond test, fracture surfaces were examined by SEM. Results: Colored zirconia showed a higher shear bonding strength than that of uncolored zirconia except for colored zirconia immersed in Zirkonzahn coloring liquid. In particular, colored zirconia immersed in Kuwotech coloring liquid showed the highest shear bond strength. After the shear bond test, mixed failure patterns were mainly observed in the failure between zirconia and veneering ceramic. Conclusion: Coloring liquid enhanced the shear bond strength zirconia and veneering ceramic than uncolored zirconia.

Observations of surface roughness of Co-Cr alloys according to grinding time of dental barrel finishing (치과용 바렐연마기의 연마시간에 따른 Co-Cr 합금의 표면거칠기 관찰)

  • Ko, Hyeon-Jeong;Park, Yu-Jin;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.43 no.3
    • /
    • pp.93-98
    • /
    • 2021
  • Purpose: The aim of this study was to observe the surface roughness and surface topography of cobalt-chrome (Co-Cr) alloys with grinding time in dental barrel finishing. Methods: This study involved two types of Co-Cr alloys. Specimens were manufactured with the dimensions 10×10×2 mm. Each specimen was cast according to the manufacturer's instructions. The cast alloys were polished for 35 minutes at intervals of five minutes in an automatic barrel finishing. Specimens were imaged with a three-dimensional optical microscope to measure surface roughness. Results: BC specimens and GM specimens had the highest roughness (Ra) values in the ungrained control group, and the lowest Ra values were measured 20 minutes after grinding. Conclusion: The best conditions for grinding Co-Cr alloy using a dental barrel finishing were a weight ratio of polishing media, water, and compound of 150 g:200 g:5 g, and a rotation speed of 450 rpm. Grinding time to obtain appropriate surface roughness should be limited to 15 to 30 minutes.