• Title/Summary/Keyword: point of coincidence

Search Result 120, Processing Time 0.027 seconds

Macroscopic Analysis on Supercritical Transition of Liquid Hydrocarbon Fuel (액체탄화수소의 초임계 천이과정에 대한 거시적 특성 분석)

  • Shin, Bongchul;Kim, Dohun;Son, Min;Lee, Keunwoong;Song, Wooseok;Koo, Jaye;Kwon, Oh Chae
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.4
    • /
    • pp.26-33
    • /
    • 2016
  • In order to analyze supercritical transition of liquid hydrocarbon fuel which used propulsion engine, visualization of phase changing using Methylcyclohexane (MCH) was performed. Also, measurements of temperature and pressure were conducted to obtain saturation lines of MCH and Decane. delayed increase of the pressure existed near the critical point due to dramatical increase of specific heats and the critical opalescence was only observed from the end point of delaying to the critical point. Beyond the critical point, the boundary between phases disappeared and the strong density gradient was observed. As the comparison between experimental and numerical saturation lines, the numerical estimation for mixture had relatively little difference while the results of pure components had almost coincidence.

Effects of Centric Relation Splint Therapy on the Occlusal Contact State in Craniomandibular Disorders (교합안정장치 치료가 교합접촉상태에 끼치는 효과)

  • Whan-Cheol Kim;Kyung-Soo Han;Seok-Man Kang
    • Journal of Oral Medicine and Pain
    • /
    • v.18 no.2
    • /
    • pp.71-79
    • /
    • 1993
  • Many types of occlusal splints are used for treatment of craniomandibular disorders. Most widely used splint among them is flat-type centric relation splint. Insertion of splint into the mouth may cause increasing of vertical dimension, masticatory muscle realignment and rearrangement of maxillo-mandibular relationship, so as a result of splint treatment, occlusal relation may vary whether you like it or not. From this point of view, occlusal state of patient shold be frequently monitored to prevent undesired or harmful effect during occlusal splint therapy. The purpose of this study was to investigate the effect of occlusal splint, especially centric relation splint, on the occlusal contact state after 3 months treatment. 32 patients with craniomandibular disorders who had unilateral symptoms participated in this study. To observe and record occlusal contact state, the author used T-Scan system (Tekscan Co. U.S.A.) at both pretreatment and posttreatment. The recorded date were analyzed with regard to contact number, contact force and contact time, change of anterior tooth contact and coincidence of first contact point with affected side were observed, too. Aan last, the subjects were divided into 2 groups and compared, according to average value of VAS index, with respect to joint pain, sound and limitation of movement, respectively. The collected date were statistically processed with SPSS and the result as follows : 1. Total occlusal contact number and force were not changed by occlusal splint therapy but total occlusal contact time decreased slightly. 2. There was a tendency of increasing number of subjects with anterior tooth contact after treatment and change of first contact point side were observed in as many as 40.6% of subjects. 3. There were no difference between higher and lower group of VAS index, and between pretreatment and posttreatment in each group, either.

  • PDF

A Study on Present Conditions and Characteristics of Cadastral Surveying Accuracy in Korea (우리나라 지적측량 정확도의 현황과 특성)

  • Yoon, Ha-Su;Choi, Yun-Soo;Son, Jong-Young;Kim, Jae-Myeong
    • Spatial Information Research
    • /
    • v.19 no.5
    • /
    • pp.27-35
    • /
    • 2011
  • The current cadastral surveying is used digital cadastral map. This map is no local confirmation. Besides, Base cadastral map drawn up 100 years ago. And Graphical cadastral characteristic is difficult to ground boundary points restoration. Due to the lack of ground boundary points can cause land dispute and Cadastral Non-Coincidence. In this Study, Understand the concept of accuracy and error, Analyzing the current regulations. Also Comparative analysis of current cadastral regulations and other surveying regulations to suggest improvements to the cadastral surveying. The results indicated a clear definition of accuracy and error and The installation of permanent ground boundary points are needed. Uniform and consistent reference point system is needed. In addition, the accuracy provided by the landowner should understand. Cadastral Surveying Regulations require specific and detailed procedures.

Studies on the Crystal Structure of Benzidine Perchlorate by X-ray Diffraction Method (I) Relation between the Space Group and the Composition of the Diamine Salt Crystal (X-線 廻折法을 利用한 벤지딘過鹽素酸鹽의 結晶構造에 關한 硏究 (I) 空間群과 Diamine 鹽 結晶의 組成과 關係)

  • Koo, Chung-Hoe;Sa Kong, Yul;Kang, Man-Hyong;Shin, Hyun-So
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.119-122
    • /
    • 1970
  • In those six kinds of diamine salt crystal of which their structures had already been determined up to date, commonly one molecule of diamine and two molecules of acid were combined; although the crystal of benzidine perchlorate, only one molecule each of benzidine and perchloric acid were combined. At the case of benzidine perchlorate, one molecule acts as the role of two molecules by coincidence of the center of symmetry point of both the lattice and molecule, and perchlorate ion is locating symmetrically between two -$NH_2$ groups of different benzidine molecule, therefore benzidine and acid could be combined together with 1:1 by mole ratio. When forming the salt with diamine and acid, the combining mole ratio would be determined in accordance with the relationship between the symmetry element that presented by the space group and the symmetry element of diamine salt melecule.

  • PDF

Evaluation of Physical Characteristics of Discovery ST scanner Using NEMA NU2-2001 Standard (NEMA NU2-2001을 이용한 PET-CT 스캐너의 물리적 특성평가)

  • Lee, Byeong-Il
    • Journal of Integrative Natural Science
    • /
    • v.1 no.2
    • /
    • pp.79-83
    • /
    • 2008
  • As a new standard for performance measurement, NEMA NU2-2001 was presented recently. In this study, I investigated the spatial resolution, sensitivity, scatter fraction, and noise equivalent count ratio (NECR) in order to know the information of physical characteristics and system performance of GE discovery ST using this new standard. Bismuth germinate crystals ($6{\times}6$ array, $6.3mm{\times}6.3mm{\times}30mm$) were used in discovery ST (energy window:375-650 keV, coincidence window:11.7 nsec). To measure the sensitivity, five aluminum sleeves (Data Spectrum Corp., Chapel Hill, NC., USA, thickness:1.25 mm)-NEMA sensitivity phantom- filled with F-18 solution were used. Successive measurements in 2D and 3D acquisition mode were made with a line source at the center of transaxial field of view and 10 cm off from the center until the count was over 500,000. Spatial resolution was estimated using a point source (F-18, 0.1 mCi) at different locations in the FOV. Scatter fraction and NECR was tested using a NEMA scatter phantom. Dynamic data were acquired for 7 half-lives using F-18 solution. And true to background ratio was averaged at last three frames when the random rate was as small as ignorable for the calculation of scatter fraction. We anticipate this overall evaluated results could be used for the quality assurance and optimized image acquisition for clinical research.

  • PDF

A Study on the Interpolation Characteristics of the Scattered Geographic Data according to the Gridding methods (격자화 기법에 따른 이산지형정보의 보간특성 연구)

  • Lee, Yong-Chang
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.4 no.2 s.8
    • /
    • pp.173-180
    • /
    • 1996
  • In a grid based data transformation, the different gridding methods provide different interpretations of scattered data because each method calculate grid node values using a different weighted mathematical algorithms. Therefore, it is necessary to review the interpolated characteristics of some gridding methods according to search distance, search area and search options before determing the best method with a data set. For this, in this paper, six different gridding methods with the same search conditions are applied to a scattered data obtained from sterro-plotter. The interpolated characteristics of the scattered geographic data considered through comparison of coincidence between the data point and the grid node being interpolated. And also, shows the real application of gridding methods through calculating volumes and creating cross sections.

  • PDF

Approximate System Reliability Analysis Under Multiple Time Varying Loads (복합 하중하에서의 구조물 체계 신뢰도 해석)

  • 김상효
    • Computational Structural Engineering
    • /
    • v.1 no.2
    • /
    • pp.101-109
    • /
    • 1988
  • The evaluation of the system reliability is generally quite difficult and costly as the structure becomes large and complex, especially when it is subjected to multiple time varying loads, and for redundant structures which have many possible modes of failur, e.g., system collapse through the formation of plastic hinge mechanisms. In reality most loadings acting on the structures are random in intensity as well as in occurrence time and duration. To include the load variability in time, the loads are described in terms of stochastic processes. Based on a tri-modal upper bound, a point estimate for the system reliability has been developed for more accuracy without extensive computational effort. This tri-modal point estimate also ensures the continuity of the system reliability function, which is a necessary condition in many nonlinear programming techniques. In addition, the Load Coincidence method, by which the combined effect of time varying loads are taken into account, has been modified to suitable for cases with an always-on load.

  • PDF

Stereotactic Target Point Verification in Actual Treatment Position of Radiosurgery (방사선수술시 두개내 표적의 정위적좌표의 치료위치에서의 확인)

  • Yun, Hyong-Geun;Lee, Hyun-Koo
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.403-409
    • /
    • 1995
  • Purpose : Authors tried to enhance the safety and accuracy of radiosurgery by verifying stereotacitc target point in actual treatment position prior to irradiation. Materials and Methods : Before the actual treatment, several sections of anthropomorphic head phantom were used to create a condition of unknown coordinates of the target point. A film was sandwitched between the phantom sections and punctured by sharp needle tip. The tip of the needle represented the target point. The head phantom was fixed to the stereotactic ring and CT scan was done with CT localizer attached to the ring. After the CT scanning, the stereotactic coordinates of the target point were determined. The head phantom was secured to accelerator's treatment couch and the movement of laser isocenter to the stereotactic coordinates determined by CT scanning was performed using target positioner. Accelerator's anteroposterior and lateral portal films were taken using angiographic localizers. The stereotactic coordinates determined by analysis of portal films were compared with the stereotactic coordinates previously determined by CT scanning. Following the correction of discrepancy the head phantom was irradiated using a stereotactic technique of several arcs. After the irradiation, the film which was sandwitched between the phantom sections was developed and the degree of coincidence between the center of the radiation distribution with the target point represented by the hole in the film was measured. In the treatment of the actual patients, the way of determining the stereotactic coordinates with CT localizers and angiograuhic localizers was the same as the phantom study. After the correction of the discrepancy between two sets of coordinates, we proceeded to the irradiation of the actual patient. Results : In the phantom study, the agreement between the center of the radiation distribution and the localized target point was very good. By measuring optical density profiles of the sandwitched film along axes that intersected the target point, authors could confirm the discrepancy was 0.3 mm. In the treatment of an actual patient, the discrepancy between the stereotactic coordinates with CT localizers and angiographic localizers was 0.6 mm. Conclusion : By verifying stereotactic target point in actual treatment position prior to irradiation, the accuracy and safety of streotactic radiosurgery procedure were established.

  • PDF

The Equality of Key Words of the Journal of Korean Dental Society of Anesthesiology with Medical Subject Headings (MeSH) (2001-2014) (대한치과마취과학회지 게재 논문들의 핵심용어와 MeSH 용어의 일치도)

  • Shim, Youn-Soo;Kim, Ah-Hyeon;You, Yong-Ouk;Kim, Il-Ho;Yu, Song-Yi;Lee, Kwang-Seok;Jeong, Chae-Yul;Kim, Eun-Hee;Maeng, Sun-Woo;An, So-Youn
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.14 no.3
    • /
    • pp.143-149
    • /
    • 2014
  • Background: The purpose of this study was to analyze the equality between key words used in the Journal of Korean Dental Society of Anesthesiology and Medical Subject Headings (MeSH). Methods: A total of 666 English key words in 187 papers (average 3.5 words in a paper) from 2001 to 2014 were eligible for this study. We classified them according to matched, and non-matched terms. After descriptive analysis, we assayed patterns of errors in using MeSH, and reviewed frequently used non-MeSH terms. Results: Fifty nine point six percent (59.6%) of total key words were completely coincident with MeSH terms, 40.39% were not MeSH terms. Conclusions: The results show that the coincidence rate of key words with MeSH terms was at a moderate level. However, there is a need for us to understand MeSH more specifically and accurately. Use of proper key words aligned with the international standards such as MeSH is important to be properly cited. The authors should pay attention and be educated on correct use of MeSH as key words.

Serial line multiplexing method based on bipolar pulse for PET

  • Kim, Yeonkyeong;Choi, Yong;Kim, Kyu Bom;Leem, Hyuntae;Jung, Jin Ho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3790-3797
    • /
    • 2021
  • Although the individual channel readout method can improve the performance of PET detectors with pixelated photo-sensors, such as silicon photomultiplier (SiPM), this method leads to a significant increase in the number of readout channels. In this study, we proposed a novel multiplexing method that could effectively reduce the number of readout channels to reduce system complexity and development cost. The proposed multiplexing circuit was designed to generate bipolar pulses with different zero-crossing points by adjusting the time constant of the high-pass filter connected to each channel of a pixelated photo-sensor. The channel position of the detected gamma-ray was identified by estimating the width between the rising edge and the zero-crossing point of the bipolar pulse. In order to evaluate the performance of the proposed multiplexing circuit, four detector blocks, each consisting of a 4 × 4 array of 3 mm × 3 mm × 20 mm LYSO and a 4 × 4 SiPM array, were constructed. The average energy resolution was 13.2 ± 1.1% for all 64 crystal pixels and each pixel position was accurately identified. A coincidence timing resolution was 580 ± 12 ps. The experimental results indicated that the novel multiplexing method proposed in this study is able to effectively reduce the number of readout channels while maintaining accurate position identification with good energy and timing performance. In addition, it could be useful for the development of PET systems consisting of a large number of pixelated detectors.